Text
.
.
JUN 1 1 1985
Docket No. 50-155
Consumers Power Company
ATTN:
Mr. R. 8. DeWitt
Vice President
Nuclear Operations
212 West Michigan Avenue
Jackson, MI 49201
Gentlemen:
This refers to the routine safety inspection conducted by Mr. G. A. Brown and
others of this office on May 20-23, 1985, of activities at Big Rock Point
Nuclear Plant authorized by NRC Operating License No. OPR-6 and to the
discussion of our findings with Mr. D. P. Hoffman and others of your staff
at the conclusion of the inspection.
,
The enclosed copy of our inspection report identifies areas examined during
the inspection.
Within these areas, the inspection consisted of a selective
. examination of procedures and representative records, observations, and
interviews with personnel.
No items of noncompliance with NRC requirements were identified during the
course of this inspection.
However, one weakness was identified which will
need corrective action by your staff.
This weakness is summarized in the
Appendix to this letter.
As required by 10 CFR 50, Appendix E (IV.F.) any
weaknesses that are identified must be corrected.
Accordingly, please advise
us within 45 days of the date of this letter of the corrective actions you
have taken, or plan to take, regarding this weakness, including the estimated
date of completion.
The responses directed by this letter are not subject to the clearance
procedures of the Office of Management and Budget as required by the Paperwork
Reduction Act, PL 96-115.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
this letter and the enclosures will be placed in the NRC Public Document Room.
i
/
b
E
(\\
kIS$ci!g,
.
..
Consumers Power Company
2
gg y y g
We will gladly discuss any questions you have concerning this inspection.
Sincerely,
C. J. Paperiello, Chief
Radiological Protection Branch
Enclosures:
1.
Appendix, Exercise
Weakness
2.
Inspection Report
No. 50-155/85004(DRSS)
cc w/ enclosures:
D. J. VandeWalle, Director
' Nuclear Licensing
D. P. Hoffman, Plant
Superintendent
DMB/ Document Control Desk (RIDS)
Resident Inspector, RIII
Ronald Callen, Michigan
Public Service Commission
Nuclear Facilities and
Environmental Monitoring
Section
D. Matthews, EPB, OIE
W. Weaver, FEMA, Region V
l
04
hk
I
h
RI
own/1d
Snell
With
DeFayette
P
1 ips
Boyd
Pa
fe110
06/10/85
.--
,
Appendix
EXERCISE WEAKNESS
,
As_ indicated in Volume 9 Section 9.2.4.3.C of the licensee's emergency plan,
one of the objectives is to assess offsite radiological conditions during and
following ar, emergency.
The licensee failed to demonstrate the capability to
meet this objective during this exercise.
The EOF was unable to effectively
' coordinate the offsite monitoring teams to locate the plume centerline and
edges.
(155/85004-01)
.