' PORTLAND GENERAL ELECTRIC COMPANY Level 1 C_.,._, n,,g gg,;'3,gn pts,t:J,ned by C3 :'"C ^i C; '!
g TROJAN NUCLEAR PLANT r.rj.ra b a, 'G-m n,. r 4.
May 29, 1992 Revision 7
- QUAllTY-RELATED EMERGENCY CONTINGENCY ACTION - ECA-3.2 STEAM GENERATOR TUBE RUPTURE WITH LOSS OF REACTOR COOLANT -
SATURATED RECOVERY DESIRED RESPONSIBLE DEPARTMENT:
OPERATIONS APPROVED BY:
A d
hba DATE:
$MM PRGthBCiDRE MANAGER EFFECTIVE DATE:
This procedure contains the following attachments:
1.
RCS SUBC00 LING CURVE.
2.
NATURAL CIRCULATION VERIFICATION.
3.
RCP NUMBER ONE SEAL LEAKOFF FLOW OPERATING RANGE.
4.
RCS C00LDOWN DATA.
A.
PURPOS.E 1.
This procedure provides actions to cool down and depressurize the RCS to cold shutdown conditions while minimizing loss of RCS inventory.
B.
ENTRY CONDITIONS This procedure is entered from:
1.
ECA-3.1, (SGTR WITH LOSS OF REACTOR COOLANT - SUBC00 LED RECOVERY DESIRED), Step 20,'when RWST level is low without a cor?:esponding increase in Containment sump level.
2.
ECA-3.1.-(SGTR WITH LOSS OF REACTOR COOLANT - SUBCOOLED RECOVERY DESIRED), Step 20, when.the ruptured S/G 1evel is high and Plant staff c.
selects saturated recovery method.
- This procedure has been extensively revised.
ZNDM.707 ECA-3.2 _ Page 1 of 30 Revision 7 9212220182 921217 PDR ADOCK 05000344 i
G PDR
/
REFERENCE PAGE FOR ECA-3.2 l
1.
AR1DilSIRAIIVE FUNCTlWfS i
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
AINTASE CGEADEIEt(I_C2(IIII12(S ACCisdefinedasContainmentPresgure>3.5psigDEContainment Radiation has been at any time 110 R/HR.
3.
EI_REll(IIIAII2( G ITER.IA
+
MANUALLY cperate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING I
4.
SECGGERY INTEGRITY MITERIA 00 TO EI-2, (FAULTED STEAM CENERATOR ISOIATI(Ef) Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is con.pletely depressur', zed and has HD.I been isolated 5.
COLD LEG RECIRCUIATIG( SWITMOVER CRITERIG(
lE RWST level decreases to <48%, IE N CO TO ES-1.3, (TRANSFER TO COLD
)
LEG RECIRCUIATIM), Step 1.
6.
AFW SUPPLY SWIT G OVER GITERIA H CST level decreases to <9%. IEH supply AFV f rom Service Water by l
opening MO-3045A and M0-3045B.
7.
MULTIPLE TUBE RUFTURE G ITERIA RETURN TO EI-3, (STEAM CENERATOR TURE RUPTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G level increases in an uncontrolled manner
- Any INTACT S/G has abnomal radiation 8.
CGtTINDOUS ACTI M STEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower Energize Source Ranges When Flux <10-amps 26.
29.
RUPTURED S/Gs NR Level.>141 30.
RCP Trip Criteria - Single Pump 32.
Containment H Concentration l
2 ECA-3.2 Revision 7
l.
SGTR WITH LOSS OF REACT 0n COOLANT - CATURAT2.D RECOVERY DESIRED l
Action / Expected Response Response Not Obtained I
4
)
1 CAUTION
- If RWST level reaches the low level setpoint of 48%, align the ECCS for cold leg recirculation per ES-1.3, (TRANSFER TO COLD LLG RECIRCULATION).
- The first 20 steps of ECA-3.1, (SGTR WITH LOSS OF REACTOR C001 ANT - SUBCOOLED RECOVERY DESIRED), thould be performed before continuing with this procedure.
4
- ** ** ** ** ** ** ** ** ** ** ** ** *= ** ** ** ** ** ** ** **
i 1.
Add Makeun To RMST As Contact TSC for consideration of Recessary other makeup sources, including unborated sources.
Blend from CVCS blender, REFER 10 01 3-7, (BLENDER OPERATION)
DE i
Pump available HUTS to RWST, i
REFEK TO OI 3-9, (BOR(M RECYCLE) i ECA-3.2 Page 2 of 30 Revision 7
.i REFERENCE PAGE FOR ECA-3.2 1.
AIMINISTRATIVE..FWCTIWS
)
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) s 2.
ADfERSE_CG(IADREt[I_CG(DITIWS ACCisdefinedasContsinmentPresgure>3.5psigQEContainment Radiation has been at any time 110 R/HR.
3.
SI REINITIATIM GITEE!a MANUALLY operate ECCS pumps as necessary if Ah(Y condition listed below occurs:
- Core exit TCs - INCREASING
SECGGERY INTF11TI MITERIA 00 TV EI-2, (FAULTED STEAM GENERATOR IS01ATIW) Step 1, if 21THER i
condition listed below occurs!
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has li2I been !solated 5.
COIR LEG RECIRCUIATIM SWITCHOVER GITERIM
)
II RWST level decreases to <481, IHDi 00 TO ES-1.3 (TRANSFER TO COLD IAG RECIRCULATIM ). Step 1.
6.
AFW SUPPLT SWITGOVER GITERIA 1E CST level decreases to (9%. IliEN supply AW from Service Water by opening MO-3045A and MO-3045B.
7.
MULTIPLE TUBE RUFTURE G 11ERIA REIVRN TO EI-3, (STEAM CENERATDR TUBE RUFTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/J 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGrTINDOUS ACTIM BTEFS 2.
Restart RBR Pumps When RCS Pressure (200 psig (<480 psig ACC) l 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify _ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
32.
Containment H 2 Concentration i
l ECA-3.2 Revision 7 l
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained CAUTION
- If RCS Pressure decreases to <200 psig (<480 psig ACC),
then the RHR Pumps must be manually restarted.
- Manually restarted RER Pumps will NOT trip on RWST low 1evel of 48%.
2.
Check If run P.-e should_Be Stopped:
a.
RCS Pressure - >200 psig a.
1E RCS pressure is between
(>480 psig ACC) 200 psig and 480 psig. Dif.N establish CCW flow to RER HXs.
Open CCW to RER Valves:
- MO-3210A
- MO-3210B GO TO Step 3.
b.
CO TO Step 3.
INCREASING c.
Stop RHR Pumps and place in standby i
l l
l ECA-3.2 Page 3 of 30 Revision 7
REFERENCE PAGE FOR ECA-3.2 1.
AIMINISTEATIYE FWCI1WIS l
- Monitor CSF Status Trees i
- Monitor Emergency Action Levels (EALs) 2.
ADFERSE CMTADElIlfT CWEDITlWiS ACCisdefinedasContainnentPresgure>3.5psigDaContainment Radiation has been at any time 110 R/HR.
3.
El REINITIATIM MITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs I
- Core exit TCs - INCREASING
SECGG&RY INTEGRITY MITERIA GO TV EI-2, (FAULTED STEAM CENERATOR ISOIATIM), Step 1, if EITHER condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and I
has NOT been isolated j
- Any S/G is completely depressurized and has NQI been isolated 5.
Colb LEG RECIRdIIATIG( SWITMOVER MITERIM
)
H RWST level decreases to (48%, IHEN GO TD IS-1.3, (TRANSFER TO COIR LEG RECIRCUIATIM), Step 1.
6.
AFW SUFFLY BWITGOVER GITERIA H CST level decreases to <9%, IllEN supply AIV f rom Service Water by opening MO-3045A and MO-3045B.
d 7.
MULTIPLE TURE RUPTURE SITERIA RETURN TO EI-3, (STEAM GENERATOR TUBE RUFTURJt), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled m.anner
- Any INTACT S/G has abnormal radiation 8.
OGITINDOUS ACTIM ETIFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Tntal Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source. Ranges When Flux _<10-amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump l
32.
Containment H Concentration 2
ECA-3.2 Revision 7 t
~--e.,
=
^~* '
d SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained CAUTION
- Feedflow should NOT be established to any RUPTURED S/G that
- is also FAULTED unless needed for RCS cooldown.
3.
Check RUPTtarn 3/Cs Isvelt a.
Verify narrow range level a.
Maintain feedflow to RUPTURED
- >7% (>14% ACC)
S/Gs until narrow range level
>7% (>14% ACC). Continue with Step 4.
M RUPTURED S/Gs level >7% (>14% ACC), M stop feedflow to RUPTURED S/Gs.
b.
Stop feedflow to RUPTURED S/Gs 4
Check For FAULTED S/Cs:
a.
Check Pressure in ALL a.
CO TO EI-2, (FAULTED STEAM S/Gs -
GENERATOR ISOIATIG(), Step 1, unless EI-2, (FAULTED STEAM
- S/G PRESSURE STABLE OR GENERATOR ISOLATION), already i
DECREASING IN A performed for the FAULTED _S/Gs.
CONTROLLED MANNER
- NO S/G COMPLETELY DEPRESSURIZED ECA-3.2 Page 4 of 30 Revision 7 i
e _
-=.
4-REFERENCE PAGE FOR ECA-3.2 1.
Alt 1INISTRATIVE FGICTIWS
)
i
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADVMSE CG(TAI]WEENT OCEEDITIGIS ACCisdefinedascontainmentPresgure>3.5psigQEContainment Radiation has been at any time 210 R/HR.
3.
SI REINITIATIGt MITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING 4
SECGtIERY INTEMITY MITERIA 00 TV EI-2, (FAULTED STEAM CENERATOR ISOIATIGt). Step 1, if EITHER l
condition listed below occurs:
i
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
C01215G RECIRCUIATIGI SWITMOFER MITERIM
)
H RWST level decreases to <48%, IEN GO TO ES-1.3, (TRANSFER TO COIE 12G RECIRCUIATIM). Step 1.
I 6.
AFW SUPPLT SWITMOVER MITERIA H CST level decreases to <91, IEN supply AFW f roni Eervice Water by opening MO-3045A and MO-3045B.
7.
IIIILTIPLE TURE RUPTURE MITERIA RETURN TV EI-3,- (STEAM GNERATOR TURE RUFTURE), Step 1, if EITHER i
condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGITINDOUS ACTIGl BTEFS
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflov 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
30.
RCP Trip Criteria - Single Pump l
32.
Containment.H2 Concentration ECA-3.2 Revision 7
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained CAUTION
- AW Pumps will trip at a CST level of 35% unless blocked.
5.
Check DfTACT E/C Invgls:
9 a.
Verify NR Level in at a.
Maintain feedflow >720 gpm least one INTACT S/G - >7%
until NR level is >7% (>l4% ACC)
(>14% ACC) in at least one INTACT S/G.
b.
Control feedflow to b.
IE NR Level in any INTACT S/G maintain NR level in all continues to increase in an INTACT S/Gs - BEWEEN 7%
uncontrolled manner. IKEN GO TD AND 50% (BETWEEN 14% AND EI-3, (STEAM CINERATOR TUdE 50% ACC)
RUPTURE), Step 1.
6.
Verify Adeaunte ShuldetD 0
Barsin:
a.
Notify Chemistry to sample RUPTURED S/Gs for boron concentration b.
Notify Chemistry to sample RCS for boron concentration ECA-3.2 Page 5 of 30 Revision 7
l REFERENCE PAGE FOR ECA-3.2 l
1.
AMINISTRATIVE FUNCTIWS
)
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADfERSE CGrIADetENT CCREDITIWS ACCisdefinedasContainmentPresgure>3.)psigDEContainment Radiation has been at any time 110 R/HR.
1 3.
SI.REINITIATIM MITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
SECGGERY... INTEGRITY. MITERIA GO TO EI-2, (FAULTED STEAM GF'fERATOR ISOIATIN), Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COLD LEG RECIRCUIATIM SWIT307ER MITERIM
)
If RWST level decreases to <48%, IREN Go To ES-1.3, (TRANSFER 70 COLD LEC RECIRCUIATIM), Step 1.
6.
AFW SUPPLY SWITG OVER M ITERIA If CST level decreases to (9%. IHEN supply AFV f rom Service Water by opening MO-3045A and M0-3045B.
i 7.
MULTIFLE TURE RUPTURE MITERIA RETURN TO EI-3, (STEAM CINERATOR TURE RUFIURE), Step 1, if 21IHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGrTINDOUS ACTIM STEPS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig 400) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energite Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
30.
RCP Trip Criteria - Single Pump h
32.
Containment H Concentration 2
ECA-3.2 Revision 7
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED 4
Action / Expected Response Response Not Obtained Step 6 continued c.
Shutdown Margin - ADEQUATE c.
Borate RCS as necessary to FOR COLD SHUTDOWN obtain desired RCS boron concentration.
- 2) REFER 10 OI 11-4 (SEUTDOWN MARCIN), for aid in detennination of desired RCS boron concentration d.
Continuously sample RCS for boron concentration e.
Borate RCS as necessary to maintain desired RCS boron concentration 7.
Initiate tcs cooldown To cold Shutdown:
a.
During RCS cooldown perform, RCS C00LDOWN DATA b.
Maintain RCS cooldown rate
- <100*F/hr 1
Step 7 continued en next page ECA-3.2 Page 6 of 30 Revision 7 I
4 4
REFERENCE PAGE FOR ECA-3.2 1.
AMINISIIATIYE_ZIRfCI1913
)
- Monitor CSP Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADfERSE CG(TAIMEENT CGGITIW(S ACCisdefinedasContainmentPresgure>3.5psigQRContainment Radiation has been at any time 110 R/HR.
3.
ELERINITIATIGt CRITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs
- Core exit TCs - INCREASING
SECGIIERT INTEGRITr MITERIA GO TV EI-2, (FAULTED STEAM GENERATOR ISOIATIW), Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressuria:
and has EQI been isolated 5.
COLD u;q RReitcHIATImt WITGOVER CRImip
)
H RWST level decreases to (40%, IEEN 00 TO ES-1.3, (TBANSFER TO COLD 12G RECIRCUIATIG(), Step 1.
6.
AFW EUPPLY WITMOVER CRfTERIA H CST level decreases to <91, 'DIEN supply ATV f rom Service Water by opening MO-3045A and MO-3045B.
7.
MULTIFI2 TURE RUFTURE CRITERIA RETURN TO II-3, (STEAM GENERA 1DR TUBE RUFTUt2), Step 1, if EITHil condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has ebnormal radiation 8.
CG(TINDOUS ACTIGI STIFS 2.
Restart RHR Pumps When 11CS Pressure (200 psig (<480 psig ACC) i 3.
RUPTURED S/Gs NK Level > 7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energite Source Ranges When Flux <10-amps l
29.
EUPTURED S/Gs NR Level >14%
l 30.
RCP Trip Criteria - Single Pump
)
32.
Containment H Concentration 2
ECA-3.2 Revision 7 l
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DE51 RED Action / Expected Response Response Not Obtained Step 7 continued c.
Use RHR System if in service in cooldown mode d.
Dump steam to condenser d.
Dump steam using INTACT S/Gs from INTACT S/Gs PORVs.
- 1) CONDENSER AVAILABLE C9 DB light on Permissive Status Panel - LIT Dunp steam using INTACT S/Gs steam supply valve to Turbine
- 2) Verify INTACT S/Gs MSIV AFP.
- 3) Place Steam Dump Mode Selector in Steam Dump steam using INTACT S/Gs l
Pressure Mode steamline low point drain to condenser:
- 4) Place RDIH LOLO TAVE l
INTERLOCK Switches in
- 1) LOCALLY elose MANUAL BYPASS isolation for RUPTURED S/Gs l
steamline low point drain to
- 5) Operate Condenser condenser:
Steam Dumps S/G MANUAL ISO l
A MS-012 B
MS-009 C
MS-010 D
MS-011 l
l L
- 2) OPEN steamline HP Drain to l
condensei:
l 1
Step 7 continued on next page l
ECA-3.2 Paee 7 of 30 Revision 7
REFERENCE PAGE FOR ECA 3.2 i
1.
AMINISTRATIVE FUNCTIWS l
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADMSE CGfTAINGNT CG(DITIES ACC is defined as Containment Presgure 3.5 psig Q1 containment Radiation has been at any time 110 R/HR.
3.
SI REINITIATIGt MITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
]
RVLIS Dynamic Head Range - <25% WITH ONE RCP RUNNING 2
4.
SECGm&RY INTEGRITY MITERIA 00 TO EI-2, (FAULTED STEAM CENERAIDR ISOLATIGI), Step 1, if EITHf,C condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled kanner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COLD LEG RECIRCUIATIGt SWJTGOVER GITERIG(
)
IE RWST level decreases to <48% IHIH GO TD ES-1.3, (TR;1MSFER TO COLD
- l LEG RECIRCUIATIGI), Step 1.
6.
AFW SUPPLT SWITCROVER GITERIA i
Il CST level decreases to <91. IHIH supply AFV from Service Water by openint MO-3045A and MO-3045B.
7.
MULTIPLE TURE RUPTURE MITERIA RETURN TV II-3, (STEAM GENERAM TUBE RUFTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CONTINUQUS.ACTIG( BTEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level > 7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Panges When Flux <10-amps 29.
RUPTURED S/Gs NR Lt.el >14%
i I
- 30. RCP Trip Criteria - Single Pump f
32.
Containment H2 Concentration l
ECA-3.2 Revision 7 1
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained Step 7 continued
- 3) LOCALLY OPEN steamline low point drain trap bypass from INTACT S/G to condensert (Located on the 45' elevation between the Steam Dumps and the "B" Condenser)
I S/G BYPASS VALVE -
A C0-390 B
CO-395 C-C0-400 D
CO-405 1E no INTACT S/G available AND RHR System HQI in service, IEEN perform the following -
- Use FAULTED S/G QR
- Use RUPTURED S/G.
9.
r%=ck RCS Subcoo14== Ramed on
.C0 TO Step 21.
Core hit TCs - >25'F
(>75'F ACC)
ECA-3.2 Page 8.of 30 Revision 7
i REFERENCE PAGE FOR ECA-3.2 1
1.
AIR 1IKISTRATIVE FGtCTI(RLS I
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADELS1_C(IfIADRGNT.CMDITIWS ACCisdefinedasContainmentPresgure>3.5psigQBContainment Radiation has been at any time 210 R/HR.
3.
El REINITIATJ W GITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
SECGtD&RT. INTEGRITT MITERIA 00 TO EI-2, (FAULTED STEAM GENERATOR ISOLATIM ), Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressarized and has HQI been isolated 5.
COIE LEC RECIRCUIATIM SWITGOVER WITERIM I
II RWST level decreases to <48%, H EN CO 10 E8-1,3, (TRANSFER TD COLD 1.EG RECIRCUIATIM), Step 1.
6.
AFW SUPPLT SWITGOVER GITERIA IE CST level decreases to (9%, H EN supply AFY from Service Water by 7
opening MO-3045A and MO-3045B.
7.
MULTIFLE TUBE RUFTURE MITERIA RETURK TO EI-3, (STEAM GENERATOR TURE RUFTURE), Step 1, if EITHER condition listed below occurs t
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has amormal radiation 8.
CM TINDOUS ACTIM BTEF1 2.
Restart RER Pumps Vhen RCS Pressure (200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Ievel >7% (>14% ACC) 5.
S/G Levels And Totti Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verifv Natural Circulation 20.
Verify Adequate Shutdown Margin-
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump g
32.
Containment H l
2 Concentration l
ECA-3.2 l
Revision 7 l
.. ~.
SGTR WITH LOSS OP REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not obtained 9.
Check If ECCS Is In Service:
00 TV Step 17.
- SI Pumps - ANY RUNNING QE
- BIT Outlet Valves - OPEN
- M0-8801A
- M0-8801B QB
Zlace All FZR Reater Switches in h Off Positigo CAUTION l
- During rapid RCS depressurization void formation may occur in *
- the reactor vessel head. This may result in rapid PZR level
- changes during depressurization, PZR spray, or pressurization.*
11.
Depressurize h Rcs To Refill The FZR:
a.
Use normal PZR spray a.
Use one PZR PORV.
IE no PORV available,'DiEN use auxiliary spray. REFER TO OI-3-3, (FRESSURIZER SYSTEM OPERATIGI).
b.
PZR level - >21% (>45% ACC) b.
Continue with Step 12. WHEN PZR level ~)21% (>45% ACC). IEEN.
stop RCS'depressurization.
c.
Stop RCS depressurization ECA-3.2 Page 9 of. 30 Revision 7
. ~.. -..
REFERENCE PAGE FOR ECA-3.2 1.
AIPtWISTRATIYE FGtCTIGIS
}
- Monitor CSF Status Trees 4
- Monitor Emergency Action Levels (Eats) 2.
ADFEASE CWTAllWEENT OGEDITIGIS i
ACCisdefinedasContainmentPresgure>3.5psisQEcontainment Radiation has been at any time 110 R/HR.
3.
SI_1E RITIATIGt MITERIA i
MANUALLY operate ECCS pumps as necessary if AIDC condition listed 4
below occurs:
- Core exit TCs - INCREASING
SECGED&RY INTEGRIT1 MITERIA 4
~
00 70 EI-2, (FAULT 3D STEAM GENERATOR 1801ATIM), Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and 1
has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COLD 12G RECIRCUIATIGt SWITG0FER CRITERIGt
)
II RWST level decreases to (48%, IHEN GO 10 RS-1.3, (TSAMSFlut 70 COLD 12G RECIRCUIATIM), Step 1.
6.
AFW SUZZLI.JKIIERQfEE_CRIIIRIA IE CST level decreases to <9%. IHEN supply AW f rom Service Water by opening MO-3045A and MO-3045B.
7.
PfULTIFLE TURE RUPTURE MITERIA RETURN TV EI-3. (STRAM GENERATOR TURE RUFTURE), Step 1, if E1IHER t
condition listed below occurs:
i
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGtTINDOUS ACTIGi STEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify.\\dequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps I
29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump I !
i 32.
Containment H2 Concentration j
l CCA-3.2 l
Revision 7
i.
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED 4
Action / Expected Response Response Not Obtained CAUTIQB
- If RCP seal cooling has been previously lost, then the affected RCP should NOT be started prior to a status evaluation.
- On natural circulation, RTD bypass temperatures and associated interlocks will NOT be accurate.
EQIE If possible RCP "B" should be run to provide normal PZR spray.
12.
Check If An RCP Rhauld Be Started:
a.
All RCPs - STOPPED a.
Stop all but one RCP. CO TO Step 13. OBSERVE NOTES prior to Step 13.
b.
RCS subcooling based on b.
00 10 Step 21.
core exit TCs - >25'F
(>75'F ACC) c.
PZR level - >21% (>45% ACC) c.
Rett!RN TO Step 11. OBSERVE CAUTION prior to Step 11.
d.
Establish conditions for starting an RCP, REFER 70 OI 3-4, (REACTDR COOIANT FIMP) (exception: proper VCT pressure is not required for RCP restart) e.
Start one RCP ECA-3.2 Page 10 of 30 Revision 7
I REFERENCE PAGE FOR ECA-3.2 1.
AIMINISTRATIVE FWICIIGIS
- Monitor CSF Status Trees
- Monitor Emergency Acilon Levels (EAls) 2.
i ACCisdefinedasContainmentPresgure>3.5psigQBContainment Radiation has been at any time 110 R/HR.
3.
El REIMITIATIGt CRITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
i 4.
SECWED&RY INTECLITT MITERIA i
GO 70 EI-2, (FAULTED STEAM GENERATOR ISOIATIGI), Step 1, if EITHER l
condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated-l
- Any S/G is completely depressurized and has HQI been isolated l
5.
COLD IJtc RECIRCUIATIWI EWITCEOVER_CRITERIGI
)
IE RWST level decreases to <48%. IHEN GO TO ES-1.3, (TRANSFER TO COLD l
LRC RECIRCUIATIGI), Step 1.
6.
6 ffERIA IE CST level decreases to (9%. IEEN supply AFW from Service Water by opening MO-3045A and MO-3045B.
7.
MULTIFLI TURE RUPTURE CRITERIA RETURN TO II-3, (STEAM CBIERATOR TURE RUFTURE), Step 1, if EITHER condition listed below occurs
}
- Any INTACT S/G 1evel increases in an uncontrolled manner-
- Any INTACT S/C has abnormal radiation 8.
OGETINDOUS ACTIGt BTEFS 2.
Restart RER Paps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown-Margin 18.
Start An RCP. Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin 21.
Verify k.CCS Flow Not Required-23.
Verify All AC Buses Energized By Off-gte Power 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >141 30.
RCP Trip Criteria - Single Pump I
32.
Containment E Concentration-2 ECA-3.2 Revision 7
[
SGTR WITH LOSS OF REACTOR COOLANT - CATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained R0JE
- After stopping any ECCS Pumps, RCS pressure should be allowed to stabilize before stopping another ECCS Pump.
- 13. Chggk If (kne CCP Shauld Be Stoppedt a.
Two CCPs - RUNNING a.
9010 Step 14.
b.
Determine required RCS subcooling using Table 1 TABLE 1 SI PUMP STATUS REQUIRED RCS SUBC00 LING NONE RUNNING 67'T (175'F ACC)'
ONE RUNNING 53'F-(166*F ACC)
TWO RUNNING 51'T (165'F ACC) c.
RCS subcooling based on c.
II RCS hot leg temperatures core exit TCs - GREATER
>395'F (>400*F ACC). IEEN 00 70 -
THAN REQUIRED SUBC00 LING Step 21.
<395'F (<400'F-ACC), IHEN start or. RER pump if none running.-
II at least one RHR Pump can EDI be started, IKEN 00 To Step 21.
d.
PZR level - >21% (>45% ACC). d.
Do NOT stop CCP. RETURN 10 Step 11. ' OBSERVE C&UTI(M prior to Step 11.
e.
Stop one CCP ECA-3.2 Page 11 of 30' Revision 7
\\
REFERENCE PAGE FOR ECA-3.2 1.
A M INISTRATIVE FtBtCTIES
)
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADVERSE CGffAINENT.CWDIIIMS ACCisdefinedascontainmentPresgure>3.5psigDEContainment Radiation has been at any t'ae 110 R/HR.
3.
SI REINITIATION S ITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed y
below occura:
1
- Core exit TCs - INCREASING
SECGm&RY INTEGRITY MITERIA 00 TV EI-2, (FAULTED STIAM GENERAIDR ISCIATIM). Step 1, if HIEE condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COLD LEG RECJ.RCUIATIM SWIT30 FIR GITERIM
)
H RWST level decreases to <48%, IEN 0010 ES-1.3, (TEANSFER TO COLD LEG RECIRCUIATIM) Step 1.
6.
AFV SUPPLY BWIICROVER MITERIA H CST level decreases to (9%, IEN supply AW from Service Water by opening MO-3045A and MO-3045B.
7.
MULTIFLE TURE RUPTURE M ITERIA l
RETURN 10 EI-3, (STEAM CENERATOR TUBE RUFTURE), Step 1, if EITHER condition listed below occurs
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGtTIND00S ACTIM STEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin 21.
Verify ECCS Flow 15t Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10~
amps l
29.
RUPTURED S/Gs NR Level >14%
f-30.
RCP Trip Criteria - Single Pump l
32.
Containment B2 Concentration l
1 ECA-3.2 Revision 7 i
i f
j.
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained j
1 J
i 14.
Check _ If the SI P-thaulLAs Stoponds a.
Any SI Pump - RUNNING a.
00 to Step 15.
b.
Determine required RCS
{
subcooling using Table 2 l
TABLE 2 1
l
$1 PUMP CEOUIRFh RCS SUB000LINC j
STATUS ONE,CP RUNNING NO CCP RUNNING l
j ONE RUNNING 83'T (196'F ACC) 500'F TWO RUNNING 49'F (163'F ACC) 53'T (166*F ACC) c.
RCS subcoolir.4 based on c.
II RCS hot les temptratures core exit TCs: - GREATER
>395'F (>400'T ACC). IEDi THAN REQUIRED SUBC00 LING GO TO Step 11.
If RCS hot leg temperatures
<395'F (<400*F ACC). Illf.N start one RHR Pump if none runnin3 II at ' east one RER Pump caa HOI be 6'.arted, IE E 00 10 Ste.' 11.
t d.
PIR level - >21% (>45% ACC) d.
Do NOT stop SI Pump. RETURN *:0 Step 11. OBSERVE CAUTI(St prior l
to Step 11.
Stop one additional St Pump e.
f.
RE1 VAN TO Step 14.a I
ECA-3.2 fage 12 of 30 Revision 7 f
,-,v..
, -,, ~.,,
-..-c o--.
-... - -,n.
-,,,c,.,
i l
REFERDiCE PAGE FOR ECA-3.2 1.
AIMINISIIAIIYE FIEtCII(I(S
)
- Monitor CST Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADDRSE_CGrIAINEENT.CSEDITIGfS ACCisdefinedasContainmentPresgure>3.5psig08 Containment Radiation has been at any time 210 R/HP.
3.
El_MINIIIAIllELCRIIEEIA MANUALLY operate ECCS pumps as necessary if AtfY condition listed below occurs:
- Core exit TCs - INCREASING
EECSGdRT.INTEGRITT CRITERIA 00 TV El-2, (FAULTED STEAM GENERATOR IS01ATI(M), Step 1, if E1DIER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated i
5.
CDIJLIAG_AEC11CUIAIIGLEKIICRQfER CkITERIGl
)
If RWST level decreases to (48%, IREN 00 TO ES-1.3, (TRANSFER TO COLD IRC RECIRC71ATI(M), Step 1.
6.
AFW EUFFLY BWITCEDVER CRITERIA II CST level decreases to (9%, IREN supply AIV from Se<vice Water by opening MO-3045A and MO-3045B.
7.
MULTIFI2 TURE RUFTUEE CRITERIA RF! URN 10 EI-3, (STEAM cENERATUR TURE RUFTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
OmrTINDOUS ACTI(El RTIFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VarifyAllACBusesEnergizedByOff-gtePower Energize Source Ranges When Flux <10' amps 26.
29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump l
32.
Containment H2 Concentration ECA-3.2 Revision 7
- - - - - -... _. =_- -
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DES! RED Action / Expected Response Response Not Obtained 15.
L'htsk If Marmal themi== Should As_Eatah11 sheds a.
Check the followingt a.
DO NOT ISOLATE BIT.
GO 10 Step 21.
- St Pumps - BOTH STOPPED
- CCPs - ALL BUT ONE STOPPED b.
RCS subcooling based on b.
H RCS hot leg temperatures core exit TCs - >59'T
>395'T (>400'F ACC). HM
(>170'F ACC) 00 TV 8tep 11.
H RCS hot les temperatures
<395'T (<400'T ACC). H M start one RHR Pump if none running.
H at least one RHR Pump can HDI be started, H Q 00 TD Step 21.
c.
PZR level - >21% (>45% ACC) c.
DO NOT ISOLATE BIT. REIVRN TO Step 11. OB8ERVE CAUTICM prior to Step 11.
16.
Establish Normal theslagt a.
Close RCP Seal Flow Control Valve (HFK-182) b.
Adjust CCP Flow Control Valve (FK-121) to minimum demand c.
Open Charging Line Isolation Valves:
- MO-8105
- M0-8106 Step 16 continued on next page ECA-3.2 Page 13 of 30 Revision 7 i
,-._..,,___m
l REFERENCE PAGE FOR ECA-3.2 1.
&[ti1RISTRATIYLFIElCIlWIS I
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADFERSLCW(IMIttINT OGIDlI1WIS ACCisdefinedasContainmentPresgure>3.5psigDEContainment Radiation has been at any time 110 R/BR.
3.
31 REIllIIIATIM MITE 11A MANUALLY operate ECCS pumps as necessary if ANY condition listed i
below occurs
- Core exit TCs - INCREASING
SECMD&EI_IltIE11Tr MITE 11A 00 70 EI-2, (FAULTED STIAN GENERATOR ISOLATIW), Step 1, if E1IHER condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurised and has HQI been isolated 5.
COLD _ LEG RECIRCUIATIM WITm0VER CRITERIM l
lI RWST level decreases to <48%, IELN 00 TU ES-1.3, (TRANSFIE 1U COLD IEC RECIRCUIATION), Step 1.
l 6.
AFW SUFFLY WI1MOTER CRITERIA II CST level decreases to (9%. IHf.N supply AfV f rom Service Water by opening MO-3045A and MO-30458.
7.
NULIIFIA TURE RUPTURE CRITERIA RETURN TO EI-3, (STEAM GENERA 1VR TURE RUFTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation F.
8.
OGtTINDOUS ACTIst ETEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin 21.
Verify ECCS Tiow Not Required 23.
VerifyAllACBusesEnergisedByOff-gtePower l
26.
Energise Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
g 30.
RCP Trip Criteria - Single Pump i
32.
Containment H Concentration 2
ECA-3.2 Revision 7 I
l SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained s
Step 16 continued i
d.
Close BIT Outlet Valves:
- MO-8801A
- MO-8801B e.
Establish 60 spm charging flow using CCP T1ow Control Valve (TK-121) while adjusting RCP Seal Flow Control Valve (HTK-132) to maintain 6.6-13 spm seal injection flow to each RCP (if seal injection established) f.
Ensure CCP RECIRC Valves
- OPEN
- MO-8111
- MO-8110
- 17. Check If 'h ref== Figy_ghould Be Controlled To Maintmin FZR Invals Check RER Pumps - NONE a.
00 10 Step 21.
a.
RUNNING IN SI MODE b.
Control charging flow to maintain RCS in"entory:
- RVLIS full range - >75%
IF NO RCP RUNNING l
- RVLIS dynamic head range
- >25% IT ONE RCP RUNNING ECA-3.2 Page 14 of 30 Revision 7 l
l
REFERENCE PAGE FOR ECA-3.2 r
a AIntDIISnAT1H_l13tCH(IIS
),
i
/
- Monitor CST Status Trees
- Monitor Emergency Action Levels (Eats) 2.
MERSE.CGfTADentT. OmtDITIG(S ACCisdefinedasContainmentPresgure>3.5psigDEContainment Radiation has been at any time 110 R/HR.
I 3.
BI. REDtITIATIME CRITERIA MANUALLY operate ECCS pumps as necessary if E condition listed below occurs
- Core exit TCs - INCREASING
SECGtI11Y DITERITY MITERIA 00 TV EI-2, (FAULTED SHAM GDERATOR 1801ATIGI), Step 1 if ElHER condition listed below occurst
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is coropletely depressurized and has RQI been isolated 5.
COLD 12G_AEC11CUMI1(ELBf12ERQtEL_C11TERIIII I
H RWST level decreases to <48%, IRM GO 70 E8-1.3, (TBANSFER 70 COLD LEG RECIRCUIATIGt), Step 1.
fa. AZW EUlfLLB(IIEROFER CRITE11A H CST level decreases to <9%, Hg supply AN f rom Service Water by opening MO-3045A and MO-3045B.
7.
MULTIFI2 TURE RUPTURE M ITERIA RETURN 10 EI-3, (STEAM CDIERAT0t TUSE RUFTURE), Step 1 if 11I111 condition listed below occurst
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGtTDID00S. ACTIMI. BTERS 2.
Restart RHR Pumps When RCS Pressure (200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedbyOff-gtePower 26.
Energize Source Ranges When Flux <10~
amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
}
32.
Containment H2 Concentration ECA-3.2 Revision 7
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DEblatD Action / Expected Response Response Not Obtained CAUTION
- If RCP seal cooling has been previously lost, then the affected RCP should NOT be started prior to a statts evaluation.
- On natural circulation, RTD bypass temperatures and associated interlocks will NOT be accurate.
HQII If possible RCP "B" should be run to provide normal PZR spray.
- 18. Check Rc7 Status a.
Verify RCPs - AT LEAST ONE a.
Start one RCP by performing the RUNNING following:
- 1) Establish conditions for starting an RCP. REFER TO 01 3-4, (REACTOR COOIANT PWIF ).
- 2) Start one RCP.
II an RCP can HQI be started, IEEN verify natural circulation.
Use Attachment-2, N A IRA 7 CIRCULATION VERITICATION.
II natural circulation can HQI be verified IRIN increase dumping steam from INTACT S/Gs.
b.
Stop all but one RCP ECA-3.2 Page 15 of 30 Revision 7
J i
REFER 9!CE PAGE FOR ECA-3.2 1.
AmINISTRATIYE F1EICTIGIS I
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADfEEEE QW[TADMINI_0GtDITIG($
J ACC is defined as Containment Presgure >3.5 pais 08 Containment Radiation has been at any time 210 R/HR.
t 3.
II REINITIATIGt MITERTA i
MANUALLY operate ECCS pumps as necessary if ANY condition listed I
below occurs:
- Core exit TCs - INCREASING
{
BEOG GkRT.INTEGEITT M ITERIA 00 TU EI-2, (FAULTED STRAM CENERATOR 180!ATIM), Step 1, if ElIEEE condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and tus MQI been isolated 5.
COLD LEC RECIRCUIATIGi EWITMOFER GITERIG(
)
II RWST level decreases to (48%, IHM 00 TO ES-1.3, (TRANSFER TO COLD IRC RECIRCUIATION), Step 1.
6.
AFW BUFFLY EWITM 0 FEE MITERIA If CST level decreases to <9% IEE supply AW from Service Water by opening MO-3045A and M0-3045B.
7.
MULTIF12 TURE RUPTURE CRITERIA RETURN TO RI-3, (8 TEAM CENERATOR TUBE RUFTURE), Step 1 if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnonnal radiation 8.
CG[IDtDQUILACIIPH_IIIts 2.
Restart RER Pumps When RCS Pressure (200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulst. ion
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergisedByOff-gtePower 26.
Energise Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
32.
Containment H2 Concentration ECA-3.2 Revision 7
SGTR WITH LOSS OF REACTOR C001 ANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained CAL!n0N
- During rapid RCS depressurization void formation may occur in the reactor vessel head. This may result in rapid PZR 1evel changes during depressurization, PZR spray, or pressurization.
- If SI has been teminated, the SI accumulators should be isolated prior to depressurizing the RCS to <775 psig
(<950 psig ACC).
19.
Destsaantian h n To Salutatlan At Core Emitt a.
Determine saturation pressure for core exit TCs, use Attachment 1, RCS SUBC00 LING CURVE b.
Use normal PZR spray b.
Use one PZR PORV.
H no PORV available, DIED use auxiliary spray. REFER TO 01 3-3, (PRESSURTIER SYSTEM OPERATI(M).
c.
Turn on PZR heaters as necessary d.
Depressurite RCS until EITHER of the following conditions is satisfied
- PZR level - >75%
(>60% ACC)
- RCS pressure - AT SATURATION PRESSURE DETERMINED IN Step 19.a ECA-3.2 Page 16 of 30 Revision 7
REFERD4CE PAGE TOR ECA-3.2 1.
AIMIMIE13AI1YLERICIIMS
)
- Monitor CS/ Status Trees
- Monitor Emergency Action Levels (EAls) 2.
&DEERSE_CWIIADMEl(I_QWED1I19(S ACCisdefinedasContainmentPresgure>3.5paisDEContainment Radiation has been at any time 210 R/BR.
3.
EI REINITIATICBt MITERIA MANUALLY operate ECCS pumps as necessary if AlfY condition listed below occurs:
- Core exit TCs - INCREASING
BBCGGERLINTEGRITY. MITERIA 00 TU EI-2, (FAULTED STEAM GEIGRATUR ISOLATI(M), Etep 1, if E1IHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is cornpletely depressurised and has liCJ been isolated 5.
C012 LEG EBcIRCU1AI19t_W12C30rER 21TERIW(
)
IE RWST level decreases to <48% IEEN 00 TV ES-1.3, (TBANSFER TD COLD LEG RECIRCUIATI(M), Step 1.
6.
AFW SUFFLLEWIIEEQtER_C11TERIA 1E CST level decreases to (9%. IEEE supply ATV f rom Service Water by opening MO-3045A and MO-3C45B.
7.
PIULTIF12 TURE RUFTURE MITERIA RETURN TV EI-3, (STIAN CINERATDE TURE RUPTUEZ), Etep 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/C has abnormal radiation 8.
QWtIII(DQUS ACTIGI BTEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Tiow Not Required 23.
VerifyAllACBusesEnergisedByOff-gtePower 26.
Energise Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump l
- 32. Containment H 2 Concentration ECA-3.2 Revision 7 i
_..~ _ _ - _._.
e j
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED f
Action / Expected Response Response Not obtained i
i
- 20. Parifv Adagnate_Ehutdors j
3 Nargint i
a.
Notify Chemistry to sample RUPTURED S/Gs for boron concentration b.
Notify Chemistry to sample j
c.
Shutdown Margin - ADEQUATE c.
Borate RCS as necessary to l
FOR COLD SHUTDOWN obtain desired RCS boron concentration.
concentration a
j
- 2) REFER 70 OI 11-4,
- i (55UTDOWN MARGIN), for 1
aid in determination of i
desired RCS boron concentration d.
Continuously sample RCS for boron concentration i
i e.
Borste RCS as necessary to i
concentration i
- 21. Verife ICCS Flow Mot Reautred:
a.
Core exit TCs - DECREASING a.
Increase dumping steam. lE core exit TCs do HQI decrease. IEEN l
MANUALLY' operate ECCS pumps as necessary.
b.
Check RVLIS indications b.
MANUALLY operate ECCS pumps as necessary.
- RVLIS full range - >75%
- RVLIS dynamic head range
- >25% IF ONE RCP RUNNING ECA-3.2.Page 17 of 30 Revision 7 r
.. ~
4 REFERENCE PAGE FOR ECA-3.2 1.
AIMINISTEATIVE FGtCTIWS
- Monitor CST Status Trees
- Monitor Emergency Action Levels (EALs) 2.
MERSE CGrIADREl(I_QGtJITICI(S ACCisdefinedasContainmentPresgure>3.5psigQBContainment Radiation has been at any time 110 R/HR.
3.
El REINITIATIM.CEITIKIA MANUALLY operate ECCS pumps as necessary if E condition listed below occurs
- Core exit TCs - INCREASING
EECGm&RY INTEGRITY MITERIA i
00 TV EI-2, (FAULTED STEAM GENERATOR IS01ATIGN), Step 1, if EITHER condition listed below occurci
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurir.ed and has HQI been isolated 5.
COLD _ LEG 35CIRCHIAI1Gl_B(IICEQtER_CRIIERIGI
)
II RWST level decreases to (48%, IEDI 00 70 ES-1.3, (TBANSFER TV COLD IAG RECIRCUIATIOM), Step 1.
6.
AFW_ SUPPLY BilTMOVIK.CEITERIA II CST level decreases to <9%. IEDI supply AFW f rom Service Water by opening MO-3045A and MO-3045B.
7.
HULTIF12 TURE RUPTURE CRITERIA RETURN TO II-3, (STEAM GENERATot TUBE RUPTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abno 1nal radiation 8.
CGtTINDOUS ACTIM STEPS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Cs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energise Source Ranges When Flux <10' amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump l
- 32. Containment H2 Concentration ECA-3.2 Revision 7
h SGTR WITH LOSS OF REACTOR C001 ANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained 22.
Check _1L_SI Accismulatora_Should 0
Se Isolatedt a.
RCS subcooling based on a.
If SI accumulators pressure core exit TCs - >25'T (140 pais. IRE 00 To step 22.c.
(>75'T ACC)
II NOT,-2XM 00 TO Step 23.
b.
PZR level - >5% (>30% ACC) b.
RETURN 10 Step 11. O'MitVE CAUTIM prior to 8tep 11.
c.
Close power supply breakers for all SI accumulator outlet valves VALVE BREAKER MO-8808A B-2510 MO-88088 B-2610 M0-88080 B-2511 MO-880SD B-2611 d.
Close all SI accumulator d.
Vent any unisolated SI outlet valves accumulator
- MO-8808A
- 1) Verify closed SI accumulator
- MO-8808B N2 SupP y (CV-8880) l I
- MO-88080
- MO-8808D
- 2) Open SI accumulator N2 IIII valve for accumulator to be vented:
ACCUMUIATOR VALVE A
CV-8875A B
CV-8875B C-
.CV-88750 l
D CV-8875D Step 22 continued on next page i
ECA-3.2 Page 18 of 30 Revision 7
3 G
REFERENCE PAGE FOR ECA-3.2 l
1.
AIMINISTRATIH_BElCIE3tS
)
1
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADFERSE CMTAIIEEENT OtMDITIWS ACC is defined as Containment tresgure >3.5 psig DE containment l
Radiation has been at any thne 110 R/HR.
i 3.
EI..RRIMITIATItal CRITERIA 3
MANUALLY operate ECCS pumps as necessary if AtG condition listed i
below occurs:
- Core exit TCs - INCREASING l
EROGED&RY INTEGRITY CRITERIA 0010 RI-2, (FAUL1ED STEAM CEMURATUR 1801ATIW), Step 1, if E1IHER condition listed below occurs:
i
- Any S/G pressure is decreasing in an uncontrolled manner-and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COID IAG RECIRCUIATIM WITCEOFER MITERIM
}
II RWST level decreases to (48%, IHIH 00 10 Es-1,3, (TRANSFER 70 COLD LEG RECIRCUIATIM), Step 1.
6.
AN BUFPLY EWITEEQtER_C112ERIA II CST level decreases to <9% IHEN supply AFV from Service Water by opening MO-3045A and M0-3045B.
i 7.
HDLTIFI2 TURE RUFTURE MITERIA RETURN TO RI-3, (STEAM GENERA 1DE TURE RUFTURE), Step 1, if ElIHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGITINDOUS ACTICEI STEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Cs NR Level >14%
30.
RCP Trip Criteria - Single Pump h
32.
Containment H Concentration 2
.ECA-3.2 Revision 7
SGTR WITH LOSS OF REACTOR C001 ANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained i
Step 22 continued i
- 3) Open SI accumulators N2 "" t (HPK-943).
f-
- 4) WM SI Accumulator is depressurised. IXfJf close SI Accumulator N2 fill valve opened in Step d.2).
- 5) Close SI Accumulators N 2 vent (HPK-943).
II HQI able to vent all unisolated SI accumulators, I M contact TSC for further assistance.
e.
Open power supply breakers for all SI accumulator outlet valves:
VALVE BREAKER MO-880BA B-2510 MO-8808B B-2610 MO-8808C B-2511 MO-8808D B-2611 l
ECA-3.2 Page 19 of 30 Revision 7 i
_,.. = _.
~ _ _.
REFERENCE PAGE FOR ECA-3.2 1.
AIIPIINISTRATIVE FIRfCTICBIS
)
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EAls) 2.
ADHRSE CGtTAIIEEENT CGtDITIGIS ACCasdefinedasContainmentPresgure>3.5psigDEContainment Radiation has been at any time 110 R/HR.
3.
El REIMITIATI2t CRITIKIA MANUALLY operate ECCS ptseps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
SECGmatf INTEMITY CKITERIA 001D EI-2, (FAITLTED STEAM GENERATOR ISOIATIGI), Step 1 if HIRE condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
C012 LEG RECIRCUIATIW( SWITCROHk CRITERIW(
H RWST level decreases to <48%, IEN Co 1U ES-1.3, (TEANSFER 70 COLD
)
12C RECIRCUIATIGI), Step I.
6.
AFW SUFFLT SWITCRO GR CRITERIA H CST level decreases to (9%, IEN supply ATV f rom Service Water by opening MO-3045A and MO-3045B.
7.
MULTIF12 TURE RUPTURI CUTERIA RE! URN TO El-3, (8 TEAM CENERAIDR TURE RUFTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal tadiation 8.
CGtTINDOUS ACTI(El RTEFS 2.
Restart RER Pumps When RCS Pressure (200 psit (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCF, Verify Natural Circulation 4
- 20. Verify Adequate Shutdown Margin
- 71. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energire Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >141
- 30. RCP Trip Criteria - Single Pump I
- 32. Containment H2 Concentration ECA-3.2 Revision 7
SGTR WITH LOSS OF REACTOR C001 ANT - SATURATED RECOVERY DESIRED Action / Expected Pesponse Response Not Obtained CAVILOR
- EDGs should NOT be run for >4 hours with (1100 KW load.
- ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** *a 23.
1erify All AC Sunas Energised 9
Ry_off-site FountI a.
V81 and V82 bus voltage -
a.
Coordinate with Load Dispatcher NORMAL to restore an incoming line.
REFER 70 MI-31, (230 KV SYSTM FAULTS).
b.
S/U transformer breakers to b.
If power is available in the H1 and H2 - CLOSED switchyard, IET.N restore power to El and H2.
REFER 10 MI-32,
- H-102 (12.47 KV AND 4.16 KV SYST1H
- H-202 FAULTS).
c.
Verify Al AND A2 -
c.
Try to restore off-site power to ENERGIZED BY OFF-SITE POWER Al AND A2.
REFEE 10 MI-32, (11.47 KV AND 4.16 KV SYST M FAULTS.
If of f-site power can HQI be restored to Al AND A2, IHT.N place additional equipment on any loaded EDO. EEFER TD MI.50, (?! ANT OFKtATIM AFTER A 1 DSS OF OFF-SITE POWER).
CONTINUE efforts to restore power while continuing with this procedure.
d.
Stop any unloaded EDG and place in Standby by performing the fo11owingi
- 1) Place unloaded EDG's IDLE AFTER AUTO START switch to IDLE
- 2) Place unloaded EDG's START /STOP CONTROL switch to STOP ECA-3.2-Page 20 of 30 Revision 7
REFERENCE PAGE FOR ECA-3.2 1.
A1EUM1EnATITE_I1MCutIfS
- Monitor CSF Status Trees
- Monitor Taergency Action Levels (EALs) 2.
ADYp1SE OMTAIRetT OGEDIT1WS ACCisdefinedasContainmentPresgure>3.5paisQEContainment Redistion has been at any time 210 R/HR.
3.
s111tMITIAT1(El CRITERIA MAh'UALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core axit TCs - INCRFASING
RECGEhLEY INTEMITT MITE 11A 00 70 E1-2, (FAULTED STEAM GWtERATOR ISOIATION), Step 1, if EITHER condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and has N0f been isolated
- Any S/G is completely depressurized and has h01 been isolated 5.
COLD IJC RECIRCtllATIGt EWITC50fER 151TERIGt g
If RWST level (ecreases to <48%, IEN 00 to E8-1.3, (11ANSPER 70 0012 180 RECIRCU1ATI(BI), Step 1.
6.
AN_SUFFLY 4[11MOFER MIIERIA If CST level decreases to (9% IEN supply APW f rom Service Water by opening MO-3045A and MO-3045B.
7.
IsrLTIPLE TURE turfekt cnITEnla RE'tVEN TO RI-3, (STRAM GREERAtt1R TURE RUP1 TEX), Step 1, -if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner e Any INTACT S/C has abnormal radiation 8.
CIEffIND005 ACTIGl_ BIER $
2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Atequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Snutdowr. Margin
- 21. Verify ECCS Flow Not Required
- 23. Verify All AC Buses Energized By Off-
.26.~EnergizeSourceRangesWhenFlux<10gtePower amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
- 32. Containment H2 Concentration ECA-3.2 Revision 7 A
GCTR WITH LOS$ OF REACTOR C001 ANT - SATURATED RECOVERY DESIRED
?
l Action / Expected Response R3sponse Not Obtained 3
I t
24.
liinimist 3acandary i
Contaminatice*
a.
Close Condenser Reject Valves I
- CV-2954B
- CV-2956B l
b.
Open Condensate Demin Bypass Valvest
- MO-7100A
- MO-7100B c.
Isolate other unnecessary flowpaths that could spread l
contamination, contact TSC for assistance I
25.-
b ck.BCF Bupper.t Status.1 a.
Support conditions for the running RCPs - AVA11ABLE l
- 1) Seal injection flow -
- 1) II normal charging 6.6-13 spm PER pump established, IHEN adjust RCP Seal Flow Control Valve (HFK-182) as necessary.
- 2) RCP tempers.tures as
- 2) Verify the following valves indicated by coroputer opent display 4RC6 - NORMAL
- 3) Provide Seal Water HX cooling:
-4)
Open RCP Seal Water Return Valves:
- MO-8100
- M0-8112 i
ECA-3.2 Page 21 of 30 Revisien 7
l RETERD4CE PAGE FOR ECA-3.2 1.
AM(IEISTRA11YE FIEtCTICR(S l
- Monitor CST Status Trees
- Monitor Emergency /.etion Levels (EALs) 2.
AINERM.CGtTAIIEEENT_(X3EDITIGIS ACCisdefinedasContainmentPresgure>3.5psisDBcontainment Radiation has been at any time 110 R/HR.
3.
BI.REUtITIATI M CRITERIA MANUALLY operate ECCS pumps as necessary if &HY condition listed below Occurst
- Core exit TCe, - INCREASING
43CWIIERY UfMG11TT CRIM 00 TO El-2 (FAULTED STIAM GENERATOR, ISO 1ATI(EI), Step 1, if EITHER condition listed below occurst
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT bcen isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
QQ12.12C RECIRCUIATIGI BWITCEOVER CRITERIGE
)
II RWST level decreases to <48%. IRCi CO 10 ES-1.3, (TBANSFER TO COLD 14G RECIRCUIAT!WI), Step 1.
6.
ADLEU2 PLT BMlICEQHL. CRITERIA IE CST level decreases to <9%. IEEN supply AFW f rom Service Water by opening MO-3045A and MO-3045B.
7.
HDLTIP12 TURE RUTTRE CRITERIA REW RN 10 El-3, (STEAM GENERA 1DR TURE RUPTURE), Step 1, if EITHER condition listed below occurst
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
OtEITDfD005 ACTICEI ETEPS 2.
Restart RER Pumps When RCS Pressure (200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >71 (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energite Source Ranges When Flux (10' amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
- 32. Containment H 2 Concentration ECA-3.2 Revision 7 I
1 SCTR WITH LOSS OT REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained
- 26. Check _lL Source Ranat_DKitctors 9
Sheuld me Instained:
Check Intergdiate Range WREflux<10~gep27.
a.
Continue with a.
flux - <10~
amps amps. IllEN perform Steps 26.b and 26.c.
b.
Verify Source Range b.
MANUALLY energize Source Range detectors - ENERGIZED detectors.
c.
Transfer NR-45 Recorder to indicate both Source Ranges EQIE Performance of E0Ps has priority over restoration of secondary Plant equipment.
- 27. ShuLDurn_Unnectasary Plaul Eauimment:
Refer To The Appropriate COI For Plant Conditions i
28.
Motify h iatry To Sample _RCS for...lodi.ne 2 to 6 Eggts After Erk9 ECA-3.2 Page 22 of 30 Revision ?
l l
. _ _. _. - _.. ~. _ _ _. _.. _
.~
F REFERENCE PAGE POR ECA-3.2 1.
AIMINISTRATITE F1BCTI(EIS
)
e Monitor CSP Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADVERSE OGrf4IIEEElff Q EDITIM S ACCisdefinedasContainmentPresgure>3.5psisORContainment Radiation has been at any time 110 R/HR.
3.
ELkEIn1TIAftet cEITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
MBOGEERY IETERITT C11TE11A 00 TO RI-2, (FAULTED STEAM GENERATUR ISOIATIGI), Step 1. if LII]iER condition listed below occurs
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is corepletely depressurized and has HQI been isolated 5.
A012 IAG.RECIRCUIATIMt.SWITMDFER CRITEElG(
)
II RWST level decreases to <481, IEN 0010 RS-1.3, (TRANSFER TV C012 LEC RECIRCUIATIW(), Step 1.
6.
AFW EUPPLY. 2f1TM0FER MITERIA 1E CST level decreases to <91. IEN supply AfW f rom Service Water by opening MO-3045A and MO-30455.
7.
IELTIFIA TURE RUFTURE CRITERIA RETUEN TO RI-3, (STEAM CENERATVE TURE RUPTURE), Step 1, if ElIRER -
condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGtTIlm00S ACTItEl STEFS 2.
Restart RER Pumps When RCS Pressure (200 psig (<480 pais ACC) 3.
RUPTURED S/Gs NR Level >7% (>14%'ACC) 5.
S/G Levels And Total Feedflow 6.-
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10' amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria -~ Single Punp l
- 32. Containment H2 Concentration
)
l ECA-3.2 RevisAon 7
_ _. _ _ _ _ _ _.. _.. _.. ~ _ -. _ _. _ _ _.. _ _. _. _. _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _...
i a
i-SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED i:.
{
Action / Expected Response Response Not Obtained 1
i l
i CAV110H l
l
- Feedflow should NOT be established to any RUPTURED S/G that
{
- is also FAULTED unless needed for RCS cooldown.
- e.**e.en***************.******....*..***
l i
29.
Chack RUrGRELAlSs_ ME 1mY.21 -
Slowly refill RUPTURED S/Gs to-64%
9
>14%
(50% ACC) NR level using feedflow.
i II either of the following conditions occurs. IEEN stop l
feedflow to RUPTURED S/Gst l
- RUFTURED S/G pressure-decreases in an uncontrolled manner.
t QR
- RUPTURED S/G pressure increases l
to 1100 psig.
l
- 30. Cbstk_1L.RCZa_.Should_.De 0
ELassad:
[
a.
Check the followingt n.
GO TO Step 31.
- RCP number one seal differential pressure -
[
<200 paid l
QA l
6 RCP number one semi leakoff. flow - LESS THAN l -
-THE LOWER LIMIT OF-THE OPERATING RANGE OF' l
. ATTACHMENT.3. RCP NUMBER ONE SEAL LEAK 0FF-TLOW.
1 OPERATING RANCE b.
Stop affected-RCPs g.
i t
ECA-3.2-Page 23'of 30 i
Revision 7 t
i e
'NW
-'-Ta'+"
e so w-ve" ot,e - -v i
e f*we-**F r
+
- w --es e=e-~ nu-w ee w www w w w*-wo
= w ev e-w-e r++wwww w w We + -+ = **--v"--Ww~tr**-**wvew*e*e=P*~h*'
- vt*m-'#1m--+'W-#
- =
t i
REFERENCE PAGE FOR ECA 3.2 1.
AIMIMISTRATIVE F WCTIW S
)
- Monitor CST Status Trees
- Monitor Emergency Action Levels (Eats) 2.
&INERSE QWQ&DEERIjX3EllIlWQ ACC is defined as containment Presgure >3.5 psis QB Contairament Radiation has been at any time 110 R/HR.
3.
81 REIN!TIAYim.mITERIA MANUALLY operate ECCS pumps as necessary if ANI condition listed below occurs
- Core exit TCs - INCREASING
$$CGG&RY INTEGRITT CRITERIA 00 TO RI-2, (FAULTED STEAM GENERATOR ISOLAT1W), Stsp 1 if EllER condition listed below occurs:
- Any S/C pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/0 is completely depressurized and has RQI been isolated 5.
COLILLEG_15CIRQUIAHWLa(12EE0f3k_CEXIER19$
)
II RWST level decree.ses to <4Bf., IEN 00 30 28-1.3, (TRANSFER 70 COLD LEC RECIRCMT!W), Step 1.
6.
AN_3UZZLI_BWIIESQfER..GRITEMIA if CST level decreases to <9%, IEN supply AW f rem Service Water by openirs MO-3045A and MO-30458.
7.
15II.Il!1L 193L EDZIDRE_CRIIt3JA RENRN 1V It-3, (87MAM GENERATOR TURE RUrWRE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G.1sval increases in' an uncontrolled manner
- Any INTACT S/G has abnormal radiation B.
DWGIMUQULACIlWLAIEtS 2.
Restart RER Pungs When RCS Pressure (200 psig (<400 paig ACC) 3.
RUPTURED S/Co NR Level >7% (>1fe% ACC) 5.
S/0 Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 19. Start An LCP, Verify Natural Circulation
- 20. Verify Adoquate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByO!!-gtePower 26.
Energise Source Ranges When Flux <10
amps 29.
RUPTURF.0 S/Cs NR Level >14%
- 30. RCP Trip Criteria - Single Pump I
- 32. Contaimeent Hg Concentration ECA-3.2 Revision 7 l
i 4
SCTR WITH LOSS OF REACTOR C001 ANT - SATURATED RECOVERY DESIRED Action / Expected hesponse Response Not Obtained
- 31. Check If m jisstem =a Be nacad_la_Asnic
- a.
Check the followings a.
00 TV Etep 32. OBSERVE CAUTIONS and MT!12 prior to step 32.
- RCS temperature - <350'F
- RCS pressure - <380 peig b.
Consult with TSC to determine if RER System should be placed its ser / ice CAHIIDH
- Containment Hydrogen Concentration indication will not be correct smtil the Hydrogen Analyser.is properly warned up.
- To prevent an H2 burn or explosion, the Hydrogen Recombiners should not be turned on if Contaltonent H 2
concentration is 24%.
l(QII This procedure should be continued while obtaining the hydrogen cample in Step 32.
32.
CharJLCantainmen.t_JJ4tasan 0
Cances.tration:
l a.
Current H2 concentration a.
Start Post-Accident Hydrogen measurement - AVAILABl.E Analyzers using 01 11-9, j
(POST-ACCIDENT NTDROGAN ANALYZER OPERATI(BI).
l
[
Step 32 continued on next page ECA-3.2 Page 24 of 30 Revision 7
~
1 RETERENCE PAGE FOR ECA-3.2 1.
AIMINISTRATIVE_F13tCI1GiS
- Monitor CSF Stetus Trees
- Monitor Emergency Action Levels (Eats) 2.
ADEERSK_C33(IM33GI(I_CGID1IlmfS ACCisdefinedascontainmentPresgure>3.5psigDacontainment Radiation has been at any time 210 R/HR.
3.
II.1EIMITIATIM CRITE11A MANUALLY operate ECCS pumps as necessary if ANY condi' ion listed below occurs:
- Core exit TCs - INCREASING
BBCWmMY. INTEGRITY CRITERIA 00 TD EI-2, (FAULTED STEAM GENERATDR ISOLATIW), Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has NDI been isolated 5.
CD1ZLLEG_RECIRCGIAIIGL3WITM0fE1 CRITERIM II RWST level decreases to (48%, IEEN 00 70 ES-1.3, (TRANSFER TD COLD g
IAG RECIRCUIATIM), Step 1.
6.
AFW S11ZZ1LB(IIC30fE1 CRITERI4 IE CST level decreases to <9%, IREN supply AFV f rom Service Water by opening MO-3045A and MO-30458.
7.
MULTIFLK.1UBE RINTURE CRITERIA l
RETURN TO EI-3, (8TIAN CENERATOR TURE RUFTURE), Step 1, if ElIEEE condition listed below occurs l
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGITINDOUS ACTI M BTEFS 2.
Restart RER Pumps When RCS Pressure (200 psig (<480 pois ACC) 3.
RUPTURED S/Cs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin i
18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-smps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
32.
Containment H2 Concentration l
ECA-3.2 Revision 7 i
SGTR WITH ?,0SS OF REACTOR C001R47 - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained Step J2 continued II NO Post-Accident Hydrogen Analyser is available, IliM direct Chemistry to obtain H2 concentration using OtF 40, (A CWmRAL CUIDE FOR POST-ACCIDetT SAMPLING FREFARATIGIS), and OtF 42, (SAMPLING OF CGITADEEENT A1M08FIEEE USING TEE POST-ACCIDETT SAMFLING SYSTEM).
WM hydrogen concentration measurement available, HM perform Steps 32.b and 32.c.
While waiting for H2 sample results, 0010 Step 33.
b.
Containment H2 b.
Notify TSC of Containment concentration - <4%
hydrogen concentration. GO TO Step 33.
c.
Containment H 2 c.
Start Hydrogen Recombiners using concentration - <0.5%
DI 10-3, (CONTADEENT NVAC).
IF Hydrogen Recombiners are liOI available, HM consult TSC concerning operation of Containment Hydrogen Vent System.
I 4
ECA-3.2 Page 25 of 30 Revision 7
REFERD4CE PAGE FOR ECA-3.2 1.
AIMIMig3&nYE_Z13tCI1(3($
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADMSE CWGADWEENT CGEDITIWIS ACCisdefinedasContainmentPresgure>3.5psigORContainment Radiation has been at any time 110 R/HR.
3.
BI.REIMITIATIWI MIZE11A MANUALLY operate ECCS pumps as necessary if ANY condition listed below occure
- Core exit TCs - INCREASING
EECG G&RY INTEGRITY MITERIA 0010 EI-2, (FAULTED STEAM GENERATOR IS01ATIWI), Step 1, if E1HER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HOI been isolated 5.
Colm IAC REC 11CUIATIGt WITm07Et GITERIGI
)
H RWST level decreases to <48%. HEN C0 TO ES-1.3, (TEANSFER TO COLD LEC RECIRCUIATIGt), Step 1.
6.
AFW.EUFFLT WITG0FER MITERIA H CST level decreases to <9%, H EN supply AFV from Service Water by opening MO-3045A and MO-3045B.
7.
HULTIFIA_TURE RUFTURE MITERIA RETURN TU EI-3, (STEAM CINERATOR TUBE RUFTURE), Step 1, if ElHEE condition listed below occurs
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CWITINU008 ACTION STEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Aderluate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin
- 21. Verify ECCS Flow Not Required
- 23. VerifyAllACBusesEnergisedByOff-gtePower Energire Source Ranges When Flux <10-amps 26.
29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
- 32. Containment H Concentration 2
ECA-3.2 Revision 7
1 i
SGTR WITH LOSS OF REACTOR COOLANT - SATURATED RECOVERY DESIRED Action / Expected Response Response Not Obtained
- 33. Chask acS Tessperatures - <200*F RETURN 'tV Step 2.
OBSERVE CAUTI(BIS p; or to Step 2.
34 Evaluate 1-=-Tem F1=nt Status a.
Maintain cold shutdown conditions b.
Consult TSC P
l 5
r END OF ECA-3.2 ECA-3.2 Page 26 of 30 Revision 7
i i
REFERENCE PAGE FOR ECA-3.2 i
1.
AMIM1S1EATIVE FWCTJWS y
- Monitor CSF Status Trees i-
- Monitor Emergency Action Levels (EALa) 2.
ADFERSE CGtTAIISENT CGEDITIGES
}
ACCisdefinedasContainmentPresgure>3.5psigQBContainment i
Radiation has been at any time 110 R/HR.
2 3.
EI REINITIATIM CRITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING l
58CGEI11Y INTEGRITT CRITERIA 00 TO EI-2, (FAULTED STEAM GENERATOR IS01ATIM), Step 1, if EITHER condition listed below occurs:
l
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COIE LEC NfMIATIGE SWITCENER cETmfm l
II RWST level decreases to <48%, IEEN 00 TO ES-1.3, (TRANSFER 70 COLD g
12C RECIRCUIATIM), Step 1.
6.
AFW EDFFLT SWITCEOFIR CRITERIA II CST level decr6ases to <9%,-IRDi supply AFV f rom Service Water by i
opening MO-3045A and MO-3045B.
7.
MULTIF12 TURE RUPTURE CRITERIA RETURN TO EI-3, (STEAM CINERATOR TURE RUPTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGITINDOUS ACTIM ETEFS 2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP,' Verify Natural Circulation 20.
Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump
)
32.
Containment H2 Concentration ECA-3.2 Revision 7
RCS SUBCOOLING CURVE 1
n 4
2500 i
r t
i t
1
-}
i 1
i.
l i
/
i
/
g l
2000 -
^e M
i i
i s
i 4
4 i
4 i
/
4 i
i
~
1 e
i s 1500-I W
i j
~
~
SUBCOOLED k
i f
REGION b
i i
e i
m 1000 -
i c
,/
f m
f.
c i
6 I I i
f T
i
/
3 4
I i
i to i
n:
500 -
O SUPERHEATED i
i REGION l
0 4bo 5bo 6bo 7bo
~300 200 l
RCS Temperature
(?F) a d
J t
i-Page 1 of'l i
i ECA-3.2 Page 27 of 30 Revision 7 m
--v n
,,.r w
-s.v-
M i
REFERENCE PAGE FOR ECA-3.2 1.
AMINISEATIVE FIEfCTIWIS
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 2.
ADFERSE.CGITAIIEEENT CGEDITIGIS ACCisdefinedasContainmentPresgure>3.5psigQRContainment Radiation has been at any time 110 R/HR.
3.
EI REINITIATIGt CRITERIA MANUALLY operate ECCS pumps as necessary if ANI condition listed below occurs:
- Core exit TCs - INCREASING
RECGGERY INTEGRITT CRITERIA 00 'It) EI-2, (FAULTED STEAM GENERATOR ISOIATIGI) Step 1, if EITHER condition listed below occurs:
?
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HOI been isolated 5.
COLD _MG_RElIRC11&Tm
)
H RWST level decreases to <48%, IE!2{ GO TO ES-1.3, (MANSFER TD COLD IJtG RECIRCUIATIGI), Step 1 6.
ADLAUFFLY.Blf1T30FER CRITERIA H CST level decreases to <9%, IHEN supply AW f rom Service Water by opening MO-3045A and MO-3045B.
7.
MULTIFI2 TURE RUPTURE CRITERIA I
RETURN TO EI-3, (STEAM GENERATOR TURE RUFTURE), Step 1, if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INIACT S/G has abnormal radiation 8.
OGtTINDOUS ACTTGI STEFS 2.
Restart bfR Pumps When RCS Pressure (200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin j
21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10-amps 29.
RUPTURED S/Gs NR Level >14%
30.
RCP Trip Criteria - Single Pump
)
32.
Containment H Concentration 2
i ECA-3.2 Revision 7 l
NATURAL CIRCULATION VERIFICATION The following are indications of subcooled natural circulation
- RCS subcooling - >25'F (>75'F ACC)
- S/G pressures - STABLE OR DECREASING
- RCS-cold leg temperatures - AT SATURATION TDtPERATURE FOR S/G PRESSURE
- RCS Delta-T - <66*F AND STABLE E
l 1
Page 1 of 1 ECA-3.2 _ Page 28 of 30
~
Revision 7
REFERENCE PAGE FOR ECA-3.2 1.
AIMINISTIATIVE FIMCTIG(S I
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EALs) 4 2.
AufERSKA3(IGest[IEMDITIG(S ACCisdefinedasContainmentPresgure>3.5psigDEContainment Radiation has been at any time 110 R/HR.
3.
SI REINITIATIG( MITERIA MANUALLY operate ECCS pumps as necessary if ANY condition listed below occurs:
- Core exit TCs - INCREASING
4.
SECGGARY INTEGEITY MITERIA 00 TO EI-2, (FAULTED STEAM GENERATDR ISOLATIG(), Step 1, if EITHER condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and has NOT been isolated
- Any S/G is completely depressurized and has HQI been isolated 5.
COIR LEG.1ECIRCUIATIG( SWITMOVER MITERIG(
l H RWST level decreases to <48%, IREN GO TD ES-1.3, (TIANSTER TO COLD LEG RECIRCUIATIGI), Step 1.
6.
AFW SUPPLT SWITCEOVER G ITERIA H CST level decreases to <9% IllEN supply AFV f rom Service Water by opening MO-3045A and MO-30458.
7.
MULTIFLE TURE RUPTURE S ITERIA RETURN TO EI-3, (STIAN GENERATOR TURE RUFTURE), Step 1 if EITHER condition listed below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnomal radiation 8.
CGrTINDOUS ACTIGi STEPS 2.
Restart RER Pumps When RCS Pressure (200 psig (<480 psig ACC) 4 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin
- 18. Start An RCP, Verify Natural Circulation
- 20. Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10~
amps 29.
RUPTURED S/Gs NR Level >14%
- 30. RCP Trip Criteria - Single Pump g
- 32. Containment H2 Concentration ECA-3.2 Revision 7
1 y
l.
E RCP SEAL NUMBER ONE LEAKOFF FLOW OPERATING RANGE
\\
'/A/////////////) \\
l bbW//?/?/?/h
?
,osea m v /,
~ /
./
,//
$$$YYbb
%M&%f%\\
~s ts&&&Wgg
~'E VMi&8
~1 h,h, /
/77 oor t u.;
v 77 7/-
b cog
//-
k oog NBBBBA _i
/ /
'/'
-002 l
l e
e v
n n
-m o
w d 6 - 3.tyg >{yri 0;;T:h' EA 2
Page 29 of 30
REFERENCE PAGE FOR ECA-3.2 1.
AIMINISTRATIYE FtBfCTIQtS
}
1
- Monitor CSF Status Trees
- Monitor Emergency Action Levels (EAls) 2.
MERSLC2tTADEsttIEEEDlIIGfS 4
ACCisdefinedasContainmentPresgure>3.5psigQBContainment Radiation has been at any time 110 R/HR.
3.
SI.REIMITIATIM CRITE11A MANUALLY operate ECCS pumps as necessary if E condition listed below occurs:
- Core exit TCs - INCREASING
SECG(D&RY INTEGRITY CRITIKIA GO TO EI-2, (FAULIED STEAM GENERATOR 1801ATIW), Step 1, if EITHEE condition listed below occurs:
- Any S/G pressure is decreasing in an uncontrolled manner and i
has NOT been isolated
^
- Any S/G is completely depressurized and has EDI been isolated 5.
COLD LRc minemATION EWI1MOFER t5tIMRf0K
)
H RWST level decreases to <48%, IHEN GO TO ES-1.3, (TBANSFER TO COLD IRC RECIRCUIATIW), Step 1.
6.
AFW EUFFLY mf1T30VER CRTTERIA IE CST level decreases to <9%, IEEN supply AW f rom Service Water by opening MO-3045A and MO-3045B.
7.
MULTJFI2.TURE RUPTURE CRITERIA RETURN TO EI-3, (STRAM GENERATOR TURE RUFTURE), Step 1, if EITHER i
condition listed.below occurs:
- Any INTACT S/G 1evel increases in an uncontrolled manner
- Any INTACT S/G has abnormal radiation 8.
CGITINDOUS ACTIGt STEFS i
2.
Restart RER Pumps When RCS Pressure <200 psig (<480 psig ACC) 3.
RUPTURED S/Gs NR Level >7% (>14% ACC) 5.
S/G Levels And Total Feedflow 6.
Verify Adequate Shutdown Margin 18.
Start An RCP, Verify Natural Circulation 20.
Verify Adequate Shutdown Margin 21.
Verify ECCS Flow Not Required 23.
VerifyAllACBusesEnergizedByOff-gtePower 26.
Energize Source Ranges When Flux <10~
amps 29.
RUPTURED S/Gs NR Level >14%
30.
RCP Trip Criteria - Single Pump
)
32.
Containment H2 Concentration ECA-3.2 l
Revision 7
_ ~ -
~
RC:
_Q_ _$_
l.
00R: Anat t ent
- QA RECORD WHEN COMPLETED ***
CrP:
POW sf OP 2 2-2 letter No.
N/A System ho.
N/A No. of Pages:
1 RCS C00LDOWN DATA Document Date:
Reference:
Record the following data, every fifteen minutes, during the RCS cooldown:
i RCS WR COLD LEG TEMP RCS RCS PRESS C00LDOWN TIME TE-TE-TE-TE-RATE PIR-PI-413B 423B 433B 443B
(*F/hr) 405 403 i
i l
L Approved:
Date:
Shift Manager Page 1 of 1 ECA-3.2 Page 30 of 30 Revision 7