Text

r

m

,4

.f.

g, m

x i

S

./

. r) J

. b

,#;/,ht.

'" a

,1 gg);

J i

i 1

i j

i t

l l

i NUCLEAR REACTOR L ABO R ATORY i

l 1

i TECHNICAL REPORT l

90013005 THE UNIVERSITY OF TEXAS l

COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING L

i i

1978 Annual Report Of The University of Texas at Austin Nuclear Reactor Laboratory 90013006 January 1, 1978 - December 31, 1978 E. L. Draper, Jr., Director D. E. Klein, Director J. A. Durack, Supervisor Taylor Hall 104 512-471-5136 March 1978

f l

F TABLE.0F CONTENTS j

Page 1.

Listsof Figures 111 11.

List of Tables iv-I.

Introduction.........................

1 II..

Laboratory Administration.

4 A.

Organization B.

Personnel C.

Reactor Committee D.

Radiation Safety Committee III.

Laboratory Development..

10 A.

Organization

.B.

Nuclear Reactor Laboratory C.

Nuclear Radiation Laboratory D.

Neutron Generator Facility E.

Subcritical Facility F.

Neutron Activation Analysis Facilities IV.

Laboratory Operation and Utilization............

13 A.

Reactor Facility V.

Laboratory Inspections..

18 A.

Inspection by the Nuclear Regulatory Commission on Facility Licensed operations and procedures VI.

Public Service Activities.......

19 A.

Sunmer High School Science Teachers Symposium B.

Lectures and Presentations C.

Tours VII.

Research Activities.........

20 A.

Funded Research Activities B.

Unsponsored Research C.

Assistance to other Educational Institutions D.

Assistance to University Teaching and Research Programs E.

Graduate Research F.

Other Analyses VIII.

Publications from the Nuclear Reactor Laboratory...... 29 h

90013007 1,

~n.- - - -

List of Figures Figure No.

1.

Floor Plan of the Nuclear Reactor Laboratory 2.

Organization Chart of the Nuclear Reactor Laboratory 90013008 e

iii

l 1

List of Tables 1

Table No.

1.

Comparison of Previous Utilization Data Nuclear Reactor Laboratory Performance Data 1975.

2.

Courses Utilizing the Reactor and Associated Facilities 3.

4.

Reactor Scrams -- Inadvertant 5.

Comparison of Yearly inadvertant Scrams 6.

Research Funding 1

90013009

~

l iv

1.

I.

INTRODUCTION This re' port has been prepared by the staff of the Nuclear Reactor

~

Laboratory (N~L). The University of Texas at Austin, to satisfy the reporting requirements of U.S.E.R.D. A. Contract Number At-(40-1)-3919 -

and 10 CFR 50.59. This report covers the period from January 1,1978 to December 31, 1978.

The NRL is presently equipped with a 250 kW TRIGA Mark III nuclear reactor, a 2200 curie Cobalt-60 irradiator, a 15 kV Cockcroft-Walton 14 MeV neutron generator, four Californium-252 neutron sources, a subcritical assembly, and a computer coupled neutron activation analysis laboratory.

The major changes made to the laboratory during this period were:

l.

Dr. E. Linn Draper, Jr., resigned as Director of this facility on September 1,1978.

Dr. Dale E. Klein assumed the position.

2.

The Automatic power control system for the TRIGA Reactor was decomissioned due to its subnormal mode of operation.

The modification to the pool pumping / purification system which 3.

was started last year was completed and the reactor pool was cleaned for the first time since installation.

4.

Replacement of a Shim Rod magnet was necessitated by an open circuit occuring in the original. Design changes by General f

)

Atomic since production of the original magnet resulted in a loss of 3/8 inch of travel in the Shim Rod.

The original Hazards Summary Report and its amndment of 1963 5.

900l3010

2 were combined and rewritten to reflect all the changes and modifications to this facility since its inception.

6.

Purchase of a new power level detector to replace the spare one being used presently.

90013011 4

e

3 12 7 SHOP AREA l

NEUTRON ACTIVATION AN ALY SIS NUCLEAR L ABORATORY TEACHING

[ 12 5

~

LABORATORY I

CH E M IS TRY

~~

~~

LABORATORY j

F OFFICE RADIOCHEHISTRY ARK LA00RATORY RM-AIR

{

CONDITIONING ROOM

~'

63tB REACTOR g

C O NSOLE VESTIBULE ROOM

-- 131 9

SHOP 13lA T

1

_. 104 i

0FFICE 13 3 DRIVEWAY s'

bd b

NORTH

~~

/\\

OFFICE O F F I C E ""

1358 135 A 90013012 FIGURE l-FLOOR PL AN OF REACTOR L A B O Ft AT O R Y C O M P L E X ~.

_y_,. _

-a,e

4 11.

LABORATORY ADMINISTRATION A.

Organization The present organizational chart of the Nuclear Reactor Laboratory is presented in ~igure 4.

B.

Personnel The following is a list of personnel of the Nuclear Reactor Labora-tory for the pern d January '1,1977 to December 31, 1977.

Laboratory Administration ar.d Staff Bauer, T. L.

+Burack, J.

A., Supervisor Campbell, B.

Cornwell, J. B.

Dao, Tuan Davidson, J. W.

+ Draper, E. L., Jr., Director (terminated)

Ebrahimi, M.

Ganthner, S.

Garvel, L. M.

Hamann, J.

Haynes, M. (terminated)

Hertel, N. E.

Hodge, S.

Hsu, D.

Klein, D. E. (Director:

Koen, B. V.

Krause, M.

Kunimoto, Y.

  • Meredith, F. A. (terminated)

Murphie, B.

Murphy, R.

Parish, T. A. (terminated)

Pradzynski, A. H.

90013013 Razzaque, M.

Rosello, C Sanders, T.

Sharif-Homayoun, A.

Simov, Rangel

  • Smith, R. D.

Taylor, G.

Tomlin, B. B., Chief Technician Yang, Sam

+ -- Licensed Senior Operator

  • -- Licensed Operator

5 i

Dean of Engineering Chairman E E. Department t

Director agg gion

~~~~~~ flue.htar Reactor Laboratory Reactor commit [ec s%

f < Co:mittee

/

\\

/

\\

/

N

/

%s

/

Reactor Supervisor

/

Iteactor

'Inntructorc Tecimicians Experimenters LINE OF RESPONSIB!UTY CONSULTATION AND VETO POWER ORGANIZATIONAL CHART nm2 90013014 1

i k

f 6

' C.'

Reactor Committee 1.

Committee Composition Regular Members:

Dr. Joe Ledbetter.

Dr. E' Linn Draper, Jr.

Dr. Harris Marcus- (Chairman)

Mr. Jack Marvin Dr. Dale Klein

- Ex-Officio Members:

Dr. H. G. Rylan' der, Chairman, Department of Mechenical Engineering Dr. E. L. Draper, Jr., Director, Nuclear Reactor Lab Mr. H. W. Bryant, University Radiation Safety Officer Mr. J. A. Burack, Supervisor, Nuclear Reactor Lab Dr. D. E. Klein 2.

Meeting Frequency The Reactor Committee met four times during the calendar year of 1978..

3.

The Nuclear Reactor Committee Annual Report for September 1977 to August 1978 is included on the following pages.

D.

Radiation Safety Committee 1.

Committee Composition Dr. E. L. Powers, Chairman Dr. L. O. Morgan Dr. Joanne Ravel Mr. H. W. Bryant, Ex-Officio l

.2.

Meeting Frequency The Radiation Safety Committee met twice during the calender year of 1978.

~

90013015

7 NUCl, EAR REACTOR COMMITTEP ANNUAh REPORT September 1977 to August 1978 function, Activities, and Membership The Nuclear Reactor Laboratory staff and facility are administered through the Department of Mechanical Engineering of the College of Engineering at the University of Texas ai-Austin.

The Nuclear Reactor Committee is a requirement of the Nuclear Regulatory Commission and its function is to insure that the nuclear reactor and its associated facilities are operated in a professional and safe manner.

This objective is met primarily by regularly scheduled quarterly meetings of the Nuclear Reactor Committee.

These meetings include a revie of the activities of the reactor staff, faculty, and asnoe;ated graduate students; a tour of the laboratory facilitic-by a member or members of the committec; and a reporting of the minutes which includes any unusual occurrences.

The committee also reviews and accepts or rejcets any special experiments or requested changes in the reactor technical specif ications and/or operating procedures.

Minutes of the commitico meetings are recorded and reviewed.

The committee does not involve itself with the day-to-day activities of the react or f acility, as these responsibilities lie with the associated faculty and professional staff of the Nuclear Reactor Laboratory.

j Membership on the corar.itree consints of two categories:

90013016

8 membern and.ex-officio members.

The committec members are I

appointed by the Dean of the Col]cgg of Engineering, usually after conferring with the Director of the Nuclear Reactor i

Laboratory and the Chairman of the Department of Mechanical Engineering.

The membern are normally faculty members 1

having some knowledge of nuclear engineering and reactor operation, but have no direct involvement in the operation of the reactor f acilit y.

In recent years one or two students have been added to the c orcn it t e e.

The members of the committee as of August 1978 are:

Professors H.L. Marcus (Committec Chairm\\an and on the Mechanical Engineering f aculty),. Joseph Ledbe t t e: (Civil Engineering), Dale Klein (Mechanical Engineering), ono Jack Marvin (student in

)

Chemical Engineering).

The, s--officio members are:

the Chairman of the Mechanical Engineering Department (H.G. Rylander), the Director of the Nuclear Reactor Laboratory (E. Linn Draper), the Reactor Supervisor (J. Burack),

and the University Rad ut; n 1.ifety Officer Bryant).

1 Activities a nd Com'acr: t

  • J The recorded activit; < at the Nuclear Reactor Cct.unittee and thouc items of businet - pertinent to the committee are included in the minute' of the quarterly meetings, copics of f

which are attached.

Thece include minutr>c for the meetings of October 33, 1977; January 30, 1978; May 1, 1978, and

~

90013017

\\

9 July 27, 1978.

Specific items of interest include:

(1) Review of the March 9-10, 1978, on-site visit of the Nuclear Regulatory Commisnion and of the April 15, 1978, response ]ctter clarifiying their comments, and (2) review and approval for unresolved safety questions a modification In addition, to one of the automatic shut-down functions.

other repairs were approved, as itemized in the minutes of the meetings.

The full-time permanent faculty associated with the nuclear area is now four, with the addition of Dalc Klein and Nolan Hertel (January 1979).

This group plus the temporary members of the faculty brings the area beyond the minimal 1cvel for a reasonable research effort.

The most significant problem in the nuclear reactor area in supporting the faculty is associated with the non-safety related equipment for both the teaching and research activitics of the laboratory.

These include (1) The Gc-Li drifted detectors', and (2) the minicomputer interfacing for activation analysis.

In the not too distant futur.e the reactor console electronics will have to be upgraded for the sustained efficient operation of the reactor.

Beyond the upgrading of the equipment, the committee secs no signifjcant problems associated with the operation of the reactor.

Harris L. Marcus Chairman Nuclear Reactor Committee 90013018

a

-l 10 111. LABORATORY DEVELOPMENT j

A.

Organization l.

Dr. Dale E. Klein assumed the position of Director when Dr.

Draper resigned on September 1,. _1978.

B.

Nuclear Reactor Laboratorv The Nuclear Reactor Laboratory is an important part of the Nuclear Engineering program at the University of Texas.

]

The Nuclear Reactor Laboratory's central feature is a Mark I TRIGA thernal fission reactor. Originally licensed by the Atomic Energy Conunission to operate at 10 KW in 1963, the Nuclear Reactor and the Reactor Laboratory have been updated over the past few years and the research capabilities of the Laboratory at e 'now quite diverse.

In 1968, the facility license was amended to allow the TRIGA reactor to operate at a steady state power icvel of 250 KW and pulsed power of 250 MW which increased experimental capabilities tremendously.

The acquisition of Lithium drifted Silicon and Germanium solid state radiation detectors along l

with dual Nuclear Data 1024 Channel multichannel analyzers coupled to a Data General Nova 800 minicomputer, into whica the outputs of the solid state

'I detectors are sent, has made possible raaid, accurate analyses of large quantities of data.

Other experimental devices available at the Laboratory are a Subcritical Assembly, a 2200 Curie Cobalt-60 irradiator, a Nuclear Chicago Sodium Iodide coincidence counting system, a neutron beam irradiation facility and numerous proportional and Geiger-Mueller detection and counting systems.

^

The Nuclear Reactor and the Reactor Laboratory are also used to teach the fundamentals of reactor operation.

Students from all over the state as 90013019

I 11 well as other organizations and groups have toured the Nuclear Reactor Laboratory. Approximately 1000 pcrsons tour the Laboratory each year.

The use, operation, regukition, security, and monitoring of the Nuclear Reactor Laboratory is controlled by the United States Nuclear Regulatory Commission, the Nuclear Reactor Committee of the University of Texas, the Director of the Nuclear Reactor Laboratory and the Radiation Control Board of the State of Texas.

The'use, operation, security and radiation monitoring of the Nuclear Radiation Laboratory is controlled by the Director of the Nuclear Reactor Laboratory and the Radiation Safety Officer of the University of Texas at Austin.

C.

Nuclear Radiation Laborgy.

The Nuclear Radiation Laboratory at Balcones Research Center has been heavily utilized by the students and staff of the Nuclear Engineering Program at the University of Texas at Austin for the past several years.

~

The initial use of the building was to house and operate a 14 MeV Texas Nuclear, neutron generator.

To facilitate experiments utilizing the neutron generator, a large quantity of graphite was obtained, machined and fomed into a 8 f t. cube into which was inserted the drif t tube of the neutron generator. This device is a very flexible one for investigating neutron migration in matter.

When the Nuclear Reactor Laboratory acquired three (3)

Californium-252 sources from Louisiana State University in 1973, the Nuclear Radiation Laboratory became the logical place for their storage and use due to the space and availability of the already installed neutron shielding 252 around the neutron generator.

Thus, with the acquisition of Cf

, students and staff can perform experiments utilizing not only the high energy neutrons 90013020

12 252 from the neutron generator but fission spectrum neutrons from Cf In' addition to the neutron generator and the Californium sources, other smaller

, radioactive sources are also used within the confines of the Nuclear Radiation I

Laboratory.

Large amounts of neutron shieloing traterial have been installed in and around the neutron generator cavity and at selected spots on the exterior of i

the building to protect other experimentalists and the environment from abnormal radiation levels. Because of the posibility of high' radiation doses within the confines of the neutron generator cavity, the Nuclear Radiation Laboratory is

~

a limited access building and a11 external doors are wired into the controls of the generator so that any unwarranted entry automatically shuts down the machine.

D.

Suberitical Facility i

In association with t'E 3Mr, the undergraduate "utlear Engineering Laboratory, the subcritical assembly nos continued to provide a facility with which the student can perform measurements that are related to fundamental reactor parameters.

Such concepts n age, diffusion, and buckling are demon-strated in individual experiment! performed by each studcrt E.

Neutron Activation Analysis Facilities The Nuclear Analytical Laboratcry has provided support for more than twenty separate projects ranging f ro r ane. lyses for criminal investigation to student laboratory support for advanced classes in chemistry, zoology, physics, and engineering.

Scientific articies based upon the results of unsponsored research by this laboratory have beer ;3ublished or accepted for publication in several journals and proceedings, and have been presented at conferences of the state, national and international level.

90013021

P 13 IV.

Laboratory Operation and Utilization A.. Reactor 1.

Operation l

During this reporting period the reactor operated for a total of j

171.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> while supporting numerous nuclear engineering and operation courses, research, and other related activities.

2.

Utilization Tables 1 and 2 show the utilization of the reactor for the year and comparisons of this data with that of previous years.

3.

Courses Offered Using the Reactor Table 3 lists the courses offered at The University of Texas at Austin which utilized the reactor and associated facilities.

4.

Maintenance During 1978 most maintenance was limited to routine and adjustments; however, in March of 1978 a loss of magnet power to the Shim Rod occurred.

It was determined that there was an open circuit in the magnet.

A replacement magnet was purchased from General Atomic.

This magnet was 3/8 inch longer than the original so that 3/8 inch of travel on the Shim Rod was lost.

The reactivity of the Shim Rod thus decreased by $.08.

5.

Inadvertant Reactor Scrams Duri'ng 1978 there were 14 inadvertant shutdowns as compared with 9 in 1977, Table 4 itemized these " SCRAMS" and compares this year's data to previous years'.

90013022 1

t l

14 i

7 i

~

TABLE 1 COMPARISON OF PREVIOUS UTILIZATION DATA Total Hours Total Number of Reactor In Burn-up Samples Operation *

(kW-hrs)

Irradiated Year 1967-66**

104.5 251 63 1966-67 150.0 595 202 i

1967-68***

342.6 28,168 2449 1968-69 260.8 49.985 1452

'1969-70 222.0 36,477 1640 1970-71 262.5 53,912 2990 1971-72 222,8 38.624 1946 1973 318.6 45,794 1347 1974 226.1 27,641 778 1

l

~

1975 206.095 20,450 363 1976 135.74 11.312 468 1977 139.29 7,509 164 1978 171,9 26,870 178

  • Includes experimental setup time, maintenance, etc.
    • 1965 was the first year the utilization data were maintained.
      • Reactor upgraded from 10 to 250 kW during this academic year.

l 90013023 9

a

....,m_..

w w-,,_

, -.,,, _...,__m_.,.---,-,.,,.,,,,-.m,,y_.,

+

15 TABLE 2 NUCLEAR REACTOR LABORATORY PERFORMANCE DATA,1978 Total Hours Total Number of Samples Burn-up)

Reactor In (kW-hrs Irradiated Operation

  • First Quarter 24.65 55 3

1978 Second 39.7 1,126 24 Quarter 1978 Third Quarter 23.67 3,908 31 1978 Fourth Quarter 83.8 11,781 120 1978 TOTAL 171.82 26,870 178

  • Includes experimental setup time, maintenance, etc.

90013024 l

16 TABLE 3 COURSES UTILIZING THE REACTOR AND ASSOCIATED FACILITIES Course Number Course Description _,

This course was a project course in -

ME. 397 wnich the experiments for ME. 397M were documented for use as an aid to the students.

ME. 361F Introductory Nuclear Laboratory Designed as an introduction to radio-active decay, activation, and radiation measure-ment.

CH. 376X A senior level course in instrumental analytical r.ethods which utilizes the Nuclear Reactor Laboratory Facilities to study Neutron Activ-ation Analysis.

CE. 390L Environmental Analysis - This is a graduate course in environmental analysis for environ-mental health engineers. Students use neutron ac-tivation analysis and energy dispersive X-ray emission spectrometry to analyze samples for toxic contaminants.

ME. 389R A special projects laboratory course for foreign nuclear engineers.

ME. 379M A reactor operations course, open to all students.

Designed to allow students with an interest in 4

nuclear power to learn basic reactor theory and participate in actually operating a nuclear reactor.

90013025

17 i

TABLE 4 REACTOR SCRAMS -- INADVERTANT 3

Intentional Operator Error 11 Instrument Error --

0 Power Outege 0

Safety

_0_

Total 14 1 ABLE 5 COMPARISON OF YEARLY INADVERTANT SCRAMS

'63 '64

'65

'66

'67

'68

'69

'70

'71

'72

'73

'74

'75 '76

'77

'78 i

10 9

3 4

3 31 15 11 13 6

10 4

7 5

9 14 j

90013026

\\

l g

18' V.

l.ABORATORY INSPECT 10t4S A.

An inspection by members of tne Nuclear Regulatory Commission p

Region IV office regarding operations occurred during March,1978, in which four items of non-compliance tere found.

90013027 e

O

19

'VI.

PUBLIC SERVICE' ACTIVITIES These activities include those other than research projects or assistance provided in the pursuit of research which are covered in Section VII of this report.

In this section the subjects are symposiums, lectures, presentations, and tours.

A.

Summer High School _ Science Teachers Symposium

+

Funded by the Electric Utility Companies of Texas, this program was designed to familiarize high chool science teachers with the theory and technology of enrrgy resources. Luring the suniner of 1978, 32 teachers participated in the program.

B.

Lectures and Presentations On numerous occasions during 1978 the NRL staff gave talks on

~

subjects including:

" Nuclear Reactor Safety,"

" Nuclear Engineering and Society," and "Re'.,earch and Development of Energy Resources."

C.

Tours and Radiation Monitoring During the calendar year of 1979, 952 persons visited the lab.

1 Most of these persons represented educational, civic, or industrial organizations, while others were part of formal engineering laboratory groups. All perrons working in or around the laboratory are provided with personal radiation monitoring devices wr.ile tour group members are randomly monitored.

Heasurable exposure to each of the above persons was less than.1 Rem in all cases.

The highest exposure to any one person this year was.05 Rem.

90013028

20 VII.

Research Projects A.

Funded Research Activities The Nuclear Reactor Laboratory is pursuing research in numerous P

areas '.m;ch are sponsored by the organizations listed below.

1.

Tho 7xas Atomic Energy Research Foundation is funding engineering stu nes pertinent to the design and construction of electric power plants based of; controlled thermonuclear fusion. These studies treat the interaction of radiation in a blanket region which acts as a heat generator for use with conventional steam turbine equipment.

Environmental effects of larger power gener-ating stations are being evaluated.

Fuel resources for fusion reactors are being examined and measurements of neutron inter-actions with typical materials are being made.

The U.S. Energy Research and Development Administration has pro-2.

vided research support by providing reactor fuel for the operation of the University of Texas at Austin TRIGA reactor.

3 The Electric Utility Companies of Texas have sponsored Summer High School Science Teachers Symposium, a program designed to

\\

familiarize these teachers with the theory and technology of energy resources.

4 The Electric Power Research Institute sponscrs research on the feasibility r

  • reducing the hazard of long-lived radioactive waste from fission reactors.

The investigations involve the evaluation of a variety of conceptual fusion reactor blankets

~

and a combination of fission products.

~

90013029

~

21

~

B.

Assistance to University Teaching and Research Progress 1.

Advanced Analytical Chemistry - Ch 376K Personnel:

J. Holcomb, Chemistry, U.T. Austin A. H. Pradzynski, Nuclear Reactor Laboratory Undergraduate students in chemistry performed quantitative determinations'of several trace elements in samples by in-

~

strumental neutron activation analysis. This was part of a course designed to acquaint senior level students with i

m various instrumental methods of chemical analysis, j

2.

Short Course on " Nuclear Radiation Application" was offered i

in April 1978.

Director:

E. L. Draper, Jr.

Personnel :

A. H. Pradzynski T. L. Bauer j

The short course w n offered to scientists and engineers interested in using nuclear radiation in their research.

Enrollment was 19 persons from chemistry, archaeology, pharmacy, geology, geophysics, health science and radiation safety. They come from UT campus in Austin, Balcones Research Center, Geophysics Laboratories in Galveston, UT Health Science School in Dallas and IS0 TEX-private company in Houston.

3.

Activation Analysis of Marine Sediments and Manganese Nodules for Rare Earths Elements Personnel:

S. K. Addy s

A. H. Pradzynski l

Activation analysis was used in a researcn project performed at the Geophysics Laboratoy of the UT Marine Science Institute in Galveston.

Sixty samples and standards were irradiated and counted after different decay times. Results were reported in a paper f

presented at a scientific meeting in Port Aransas.

90013030

22 4.

Activation _ Analysis of Ferro-Allon o

Personnel:

A. H. Pradzynski 7..

In cooperation with University of Monterey, Mexico samples of Ferro-alloys were analyzed.

C.

Other Analyses _

l.

Analyses of Bronze Artifacts for Major and Minor Elements Personnel:

A. H. Pradzynski

)

D. Hamilton, TARL, UT Austin i

Bronze and other artifacts were analyzed by x-ray fluorescence i

spectrometry.

l D.

Unsponsored Research 1.

Analysis of Uranium and Thorium in Water by X-ray Fluorescence Spectrometry Personnel:

A. H. Pradzynski Previous work on U and Th determin tion by APDC precipitation and X-RF spectrometry was extended in order to use the method for control of contamination of the environment around uranium mining' sites in Texas.

Results were presented at the Annual Meeting of Texas Asso:;iation for Radiation Research in Houston, Texas, flovember 4-5, 1977 E.

Graduate Research 1.

Neutron Interaction Studies a) Fission Devices E. Linn Draper, Jr. - P.I.

Y. Kuniinato - Research Assistant (MS Candidate) 90013031

23 Toxicities of fuel Cycle Wast. Streams An evaluction is ur.derway of the toxicity of potential waste streams at each.t ep of.ix nuclear fuel cycle'. The objective is to identify fuel cycles for which long term hazard can be made x-acceptably small and to emphasize the importance to toxicity of potential waste strea.4 which nave received little attention to date.

i b)

Fusion Devices 1

i) Systems Analysis of Nuclide Transmutation j

E. Linn Draper, Jr. - P.I.

J. W. Davidson - Research Assistant (PhD Candidate)

A system including light water react ors, reprocessing. parti-1 tioning, and tranmutat. ion Jo. ices is being evaluated to ascertain required neutron fluences and chemical separation capabliities to i

reduce ef fluent toxicity + o a few times uranium ore toxicity.

ii) Radiation llazards fro.: Structural Activation of Fusion Reactors E. Linn Drapcr, Jr. - P.I.

R. D. Smith tesearch Assistant (PhD Candidate)

Comparisons are bcire wde of the potential hazard from structural

)

activation of a variety of proposed materials in fusion devices.

Several first wall replacement strategies are being evaluated on the basis of their risk to both a rkers and the public, iii) Fusion-Fission Hybrid Safety Analysis Dale Klein - P.I.

Yueh-Sam Yang - Research Assistant (PhD Candidate)

An examination is being made of thc heat generation and removal characteristics of a fusion hybrid blanket. Consideration will be

~

given to transient as well as steady state operation.

90013032

24 c) Accelerator Devices 1)

Fissile Fuel Production E. Linn Draper, Jr. - P.I.

StephenGanthner-ResearchAssistant(MSCandidate)

For many years high current accelerators have been proposed as neutron sources to breed fissile material from either uranium-238 or thorium-232.

Recent policy decisions on the deployment of breeder reactors and the possible advent of inexpensive. accelerators have renevred interest in this concept.

This v/ork is aimed at establishing the technical requirements for success.

ii) Heat Removal Considerations E. Linn Draper, Jr. - P.I.

M. Razzaque - Research Assistant (PhD Candidate)

The remcval of heat fro the target /Slanket region of a 300 mA, 1 GeV accelerator while retaining an apocopriate neutron population is being evaluated.

2, Radioactive Waste Regository Sitira a) Public Acceptance S. Lopreato, E. Linn Draper, Jr. - P.I.

W. Murphie - Research Assistant (MS Candidate)

An exanination viill be rade of the ways in vehich people acquire technical informatico and M. that information can most effectively be conveyed.

b) Design and Economics 1)

Temperature Considerations in Waste Repositeries Dal e Kl e i n - P. I.

~

James Hamann - Research Assistant (MS Candidate)

An evaluation is being made of the temperature distribution in geologic repositories for spent fuel and reprocessed viastes in a 90013033

25 variety of formations as a function of canister spacing and time after emplacement.

ii) Spent Fuel Disposal Charges a

E. Linn Draper, Jr - P.I.

T. Sanders - Research Assistant (MS Candidate)

The Department of Energy has proposed to accept, store, transport, and dispose of spent nuclear fuel assemblies for a fixed fee.

The assumptions of quantities, delivery schedules, cost of facilities and pricing methodology are being evaluated critically, iii) Environmental Impacts of Repository Ef fluents E. Linn Draper, Jr. - P.I.

Sharif-Homayoun - Research Assistant (MS Candidate)

The pathways by which radionuclides might be transported from the repository to man through the geosphere and biosphere are l' ping evaluated and calculations will be.made for representative sites.

3.

Gas Cooled Fast Reactor Studies a) Temperature Profile and Pressure Drop Around CCFR Spacer Grids Dale Klein - P. I.

G. Taylor - Research Assistant (MS Candidate)

Recent experinental data indicate an increased pressure drop around grid spacers for rouph rods as compared to smooth rods.

Since the fuel rod surface for the GCFR will be roughened, an accurate analysis of these grid spacers is needed.

A theral hydraulic computer code (SAGAP0) has recently been developed at Karlsruhe, Germany.

This code will be modified to consider the recently observed pressure drop characteristics.

The results of this study will be used in the Core Flow Test Loop (CFTL) being built at OR"L.

90013034

26 b) Temperature and Pressure Drop Studies at the ORNL CFTL Dale Klein - P.I.

S. Hodge - Research Assistant (PhD Candidate)

The recently developed code (SAGAPO) described above has some severe restrictions thet prevent its application to analysis of the Core Flow Test Loop (Cfil).

One of these restrictions involves the fuel rod diameter. The CFTL will have larger diameter bundle support rods and this prevents the thermal-hydraulic analysis using SAGAPO. This project involves the modification of SAGAP0 to include a new method of channel rmdeling.

Prelin,inary results on a new modeling method for obtaining the parcmeters look extremely premising and have important implications on present transformation methods.

After SAGAPO has been modified, the results will be applied to the CFTL and checked with the U.S. computer version COBRA 4.

c) Experimental Measurement of Local Heat Transfer Values Dale Klein - P.I.

J. Percy - Research Assistant ("S Car.didate) 1 A method is being deviseti for the interpretation of data for l

a single roughened surface placed inside a rect 3ngular wind tunnel.

An aluminum test base with removable roughness elements has been designed and fabri<.ated.

Local heat trcnsfer ceasurenents will be obtained using Rdf heat flux sensors.

Heat vill be generated by i

electrical resistance underneath the aluminum test base. Af ter the

,?

determination of these local heat transfer values sutrounding the roughness elements the result will be applied to the roughness design for the GCFR.

90013035

27 4.

Nuclear Analytical Techniqun Dale Klein P.I.

M. Aliy - i'escarch A<.s istant (M'; Can:iida t e)

A preconcentralian method for field sampling of trace elements p

in water is being developed.

Specifically this technique will be applied to uranium concentrations in water This method can be used as an indication for patcntial uranium deposits as well as environmental monitoring at a mining site.

1 90013036 O

23

p..

TABLE 6 RESEARCH FUttDING Texas Atomic Energy Research Foundation

$ 40,000 ERDA -- Californium-252 Loan Program Center for Energy Studies 32,71 3 1

Southwest Research Institute 23,736 i

TOTAL

$ 96,449 1

O 90013037 O

29 Vill.' Publications From Nuclear Reactor Laboratory, K.L. Gilbert, " Neutron Flux Mapping of a Subcritical Reactor Core with 1.a Polyethyle'ne Reflector", Masters. Thesis, Physics Department, The University a

of Texas, 61 pp., June 1961.

T.T. Doss, " Neutron Density Distribution in and Unreflected Subcritical 2.Reactor Core", Masters Thesis, Physics Department, The University of Texas

.63 pp., June 1961.

J.M. Norwood, "The Point Source Transport Solution for the Position and 3.Velocity Dependent Neutron Distribution in a Spherical Body of Non-Multiplying Material", Masters Thesis, Physics Department, The University of Texas, 75 pp.

June, 1962.

4.

R.W. Reed, "Effect of a Cadmium Control Rod on the Neutron Density in a Subcritical Reactor", Masters Thesis, Physics Department, The University of Texas, 85 pp., August 1962.

P. Berananda, " Neutron Flux Distribution of a Subcritical Reactor Core 5.with a Graphite Refic-tor", Masters Thesis, Physics Department, The University of texas, 40 pp., dansary 1962.

T. A. Fredericks, " Thermal Neutron Flux Distribution Due to a Plane Wave 6.Source in and Unreflected Reactor Assembly", Masters Thesis, Physics Department, The University of Texas,107 pp., August 1963.

D.G. Martin, " Film Detector for a Neutron Spectrometer", Masters Thesis, 7.

Physics Department, The Univerisyt of Texas, June 1963.

8.

M.L. West II, " Flux Decay Rate in a Reflected Subcritical Reactor",

Masters Thesis, Physics Department, The University of Texas, 55 pp., August 1963.

l R.D. O' Dell, "The Angular Thermal Neutron Spectrum in the Vicinity of the 9.Interface Between Two Media", Ph.D. Dissertation, The University of Texas, 186 pp.,' January 1965.

10, 8.E. Thompson', Sr., " Cryogenic Neutron Spectra Measurements Across a Discontinuity in Temperature and Properties", Ph.D. Dissertation, The Univer-sity of-Texas, 149 pp., January 1965.

11. R.S. Kolflat, "An Experimental Approach to tne Study of Nucleonic Funda-mentals", Masters Thesis, Mechanical Engineering Department, The University of

. Texas,190 pp., May,1965.

12. D.G. Anderson, "A Technique for Recoil Fission Fragment Range Measurements",

Health Physics, Vol.1, No. 4, 558, April 1966.

2

13. J.B. Whitworth, "A Cryogenic Irradiation Device for the TRIGA Mark i Nuclear Reactor", Masters Thesis, Mechanical Engineering Department, The Uni-versity of Texas, 52.pp., January 1967.

90013038

30 l

14.

D. A. Pullen, " A Rod Oscillator Design and 7ero Power Transfer Function l

Measurement for a TRIGA Mark 1 Reactor," Masters Thesis, Mechanical Engineering (Nuclear Engineering), The Ur.iversity of Texas, JanJary,1967.

15.

G.F. Malan, " Transfer Function Analysis of Temperature and Xenon Feedback in Coupled-Core Nuclear Reactor Systems", Masters Thesis, Mechanical Engineering Department, The University of Texas, 69 pp., August 1967.

16.

M.G. Stevenson, " Investigations on the Macroscopic Nodal Approach to Space-dependent Nuclear Reactor Kinetics", Ph.D. Dissertation The University of Texas, 203 pp., August 1968.

17.

F.H. Antunez-Castillo, " Gamna Radiation Dosimetry Techniques and Appli-cation to Mapping of The University of Texas Cobalt-60 Irradiation Facility",

Masters Thesis, Physics Department, The University of Texas, 60 pp., September 1968.

18.

R. Valiente, " Neutron Radiography with the University of Texas TRIGA Nuclear Reactor", Masters Thesis, Physics (Nuclear Engineering), The University of Texas, August 1968.

19.

P.J. Rodriguez and D.H. Nolyen. 'line Decay Constents in Pulsed Multi-plying Media", Trans. Amer Nucl. Soc. 11:1, 289 (June 1968).

20.

P.J. Rodriguez and D.H. Nguyen, "The Maximum Eigenvalue in the Pulsed-Neutron Initial-Value Problem", Trans. Amer. Nucl. Soc.~ ~ ~ -11:2, 578 (November 1968).

~ '~

21.

P.J. Rodriguez and D.H. Nguyen, ' Contribution of the Cuntinuum to the Neutron Transient Behavior in a Puis<ft "ol tipl yine C vl i nder", Trans. Amer.

Nucl. Soc., lL 2 582 (Noventier N ;.

2 22.

G.D. Bouchey and S.J. Gage, A utron Radiography with a Small Suberitical Reactor", Trans. Am. Nucl Soc.

12, E -463, 1969.

23.

G.D. Atkinson, Jr., W. Coltharp, P Cramatges, E. Delkers, D.A. Roberts, K.R. Waid, S.H. Gage, end B.V. Foan " Project Atlantis: A Design of the Nuclear Power Supply f or an Undersea t it s", Proceedings of the Offshore Technology Conference, Dallas, Texas (1969).

~

24.

J. A. Villalobos, "A Study of Gm Radiation Dosimetry Techniques and Application to Radiation Field 'bpping", Masters Thesis, Physics Department (Nuclear Engineering), The UniversMy of Texas, January 1969.

25.

M. A. Zuniga, " Delayed f<eutron Counting Techr.ique for Uraniun Determination",

Masters Thesis, Physics Department (1uclear Engineering), The University of Texas, January 1959.

~

26.

V. Chanto, S.J. Gage, and D.F mrker, " Chlorine ano Bromine Concentrations in Some Haliburton-Bancroft Rocks nd Minerals by Neutron Activation Analysis,

1969.

90013039 l

1

31

27. M..Gallardo, S.J. Gage, and D.F. Barker, " Trace Elements in Quartz by Nondestructive Neutron Activation Analysis", 1969.

28.

G.D. Atkinson, Jr., "InvestirH tion of the Dynamic Behavior of a Two-Region Subcritical Reactor", Masters Thesis, Mechanical Engineering (Nuclear Engineer-ing), The University of Texas, January 1969.

29.

M. Gallardo, " Trace Ei.nents in Six Quartz Samples by Nondestructive Neutron Activation Analysis Technique," Masters Thesis, Physics Department (Nuclear Engineering), The University of Texas, January 1969.

30.

F. A. Rodriguez. 5.J. Guoe, and K.M. Ralls, " Nondestructive Neutron Activation Analysis for Trace impurities in Ni bium", Seventh Symposium on Nendestructive Evaluation of Lomponent' and Material 3 in Aerospace, Weapon Systems, and Nuclear Applications, San Artonio, Texas (1969).

31.

S.J. Gage and M. Zuniga, " Uran ium Trace Analys is by Pulsed Reactor Irra-diation", Radiation and Isotope Technology in Latin American Development, American Nuclear Society Topical Moet ing, San Juan, Puerto Rico, May 4-6, 32.

R.H. Richardson, " Migration, anJ Enzyme Polymorphisms in Natural Popula-tions of Drosophila", Jan. J. Gen.

(in press), 1969.

33.

R.H. Richardson, R.J. Wallsce. Jr, S.J. Gage, G.D. Bouchey, and Margaret Denell, " Neutron Activation Techn q m for Drosphila in Natural Populations",

Studies in Genetics, Marshall R. Wheeler Ed., The University of Texas Press, Austin, Texas 1969.

34.

G.D. Bouchey and S.J. Gag._, "h 'iopment and Patential Utilization of a Neutron Radiography Faciliti at ih" %iversity of Texas NuclearReactor Laboratory",

Seventh Symposium on Nondestcuttivc E aluation of Components and Materials in Aerospace, Weapons Systems, and Lc ir 2 Applications, San Antonio, Texas (1969).

35.

G.D. Bouchey and S.J. Gage, v il iation of t h c-University of Texas TRIGA Reactor for Neutron Activation Analv.'

Service",(th/CNA Transactions (11)

p. 287, 1968.

36.

G.D. Bouchey and G. Gie / i, ' C'..ical Stud ies of M w-Ve ra Juice --

Il inorganic Ingredients", M J q Lv J ur nal of Crude Druc Research, Vol 9,

No. 4 (1969).

37.

S.J. Gage, R.H. Ric hardson, Rd i.D. Bouchey, Neutnn Activation Tech-niques for Labelina of Insec ts with StaH e Elements, leans. Am. Nucl. Soc.,

12, 495-496, (1969).

~~~ ~

38.

F.G. Pasos, "thndissmrs ne X A v 'luorescence Analysit Using a Lithium-Drifted Germanium Detector", Master, Thesis, Physics Depa,tnent, The University of Texas, 54 pp., January 1969.

~

90013040

32 l

l 39.

P.J. Rodriguez, " Time and Energy Dependent Neutron Distribution in a i

Pulsed Multiplying Medium", Ph.D. Dissertation, The University of Texas, i

I 205 pp., January 1969.

y 40.

G.D. Bouchey, B.V. Koen C.S. Beightler, "The Optimal Allocation of 1

Energy in Industrial and Agro-Industrial Complexes Using Dynamic Programming",

l Nucl. Sci. and Engr., Vol. 41, 70-78 (1970).

l l

41.

G.F. Malan and B.V. F.oen, " A Nonlinear Progracming Approach to Optimal Control of Nuclear Reactors", Tr_ans. Am. Nucl. Soc., November 1970.

I 42.

M.G. Stevenson and S.J. Gage, " Application of a Coupled Fission Mode Approach to Modular Reactor Kinetics", Journal of Nucl. Energy, Vol. 24, pp. 1-10. Pergamon Press 1970.

Printed in Northern Ireland.

43.

G.D. Bouchey and S.J. Gage, " Neutron Radiography at The University of j

Texas Nuclear Reactor Labcratory", Isotopes and Radiation Technology 1, 294-296 (Spring 1970).

~

3 j

44.

D.G. Jopling, "The Politics of Nuclear Reactor Siting", Masters Th6,.s, Mechanical Engineering, The University of Texas, December 1970.

I 45.

A.H. Urdaneta, "A Prograrmed Am iative Analyzer", Masters Thesis, j

Mechanical Engineering (Nuclear Enqineering), The University of Texas, December

)

~

1960.

l 46.

G.D. Bouchey and S.J. Gage, "Deta tion and Location of Leaking TRIGA l

Reactor Fuel Elements", GA Publication T-il7, Paper and Abstracts, TRIGA Reactor Owners' Seminar, February 19-20,1970 (Denwr, Colcrado) p. 43.-

47.

G.D. Bouchey and S.J. Gage, Neutron Radiography with a Small Subcritical j

Assembly", International Journal of Nondestructive Testing, (1970).

I i

48.

G.D. Atkinson, Jr., J.B. Whitwarth, and S.J. Gege, "NAAC0L--A Spectrum Analysis Routine for the Small Laboratcry", 21st Mid-America Symposium on Spectroscopy, Chicago, illinoi, (1970).

I 49.

S.J. Gage, G.D. Atkinson, Jr., J0 Whitworth, and A.H. Pradzynski,

" Computer-Aided Multielement Gama hay Analysis with a Compton Suppressed Ge(Li) Radiation Source", Ninth National of the Society of Applied Spectros-copy, New Orleans, Louisiana, October 5-9, 1970.

i S0.

K.R. Waid, " Solid State Radiation Detection Devices:

Fabrication, Techniques I

and Application to Nuclear Engineering', Masters Thesis, Mechanical Engineering l

(Nuclear Engineering), The Univenity of Texas, January 1970.

j Sl.

V.H. Chanto, " Neutron Activation Analysis of Chlorine ae Bromine in Some Haliburton-Bancrof t Rocks and Minerals", Masters Thesis, Physics (Nuclear Engineering), The University of Tev.as, January 1970.

90013041 4

. ~.

33 52.

.J.J. Chromik and E.L'. Draper, Jr., " Energy Integral Tests of Differential Fission Cross Section Data"_, Trans. Am. Nucl. Soc., Vol.,1_3, No. 2, p, 755 (1970).

3..

53.

R.J. Gramatges-Figueras, '" Neutron Waves in Cylindrical Geometries for a Subcritical~ Reactor", Mosters Thesis, Mechanical Engineering Department, The i

University of Texas, 98 pp., May 1970.

54.

E. Delkers, Jr., "A Learning Methot for Identification of. Nuclear Reactor Point Dynamics", Masters Thesis, Mechanical Engineering Department, The Uni-versity of Texas, pp. 165, August 1970.

55.

F. A. Rodriguez-Gonzalez, " Application of Neutron A..tivation Analysis to the Study of Interstitial Solid Solution of Oxygen in Niobium and in

. Niobium-Titanium Alloys",. Ph.D. Dissertation. The University of Texas,131 pp.

' August 1970.

56.

J.R.- Deen, " Calculation of Resonance Integrals Using the Intermediate r

Resonance Approximation", Masters Thesis, Mechanical Engineering Department, The University of Texas,140 pp., January 1970.

57.

C.T. Rombough, " Application of Queueing Theory to Closed-Loop Computer-Reactor Control Systems", Masters Thesis, Mechanical Engineering Department, The University of Texas, 78 pp., December 1970.

58.

A.H.U. Bohorquez, "A Programmed Associative Analyzer", Masters Thesis, Mechanical Engineering Department, The University of Texas, 98 pp. December 1970.

59.

S.J. Gage and D.G. Jopling, The Nupl_ex Concept:

Potential for the SINB Region, Southern Interstate Nuclear Board, 250 pp., March 22, 1971.

~

60.

G.F. Malan and B.V. Koen, " Application of Nonlinear Programming to the Optimal Control of a Point Model Nuclear Reactor". Nucl. Sci. and Engr.,

(1971).

61.

G.D. Bouchey, B.V. Koen, and C.S. Beightler, " Optimization of Material Safeguards Sampling System", Tran_s. Am. Nucl. Soc., Winter Meeting, (1971).

1 62.

A.H. Pradzynski and S.J. Gage, " Nondestructive Identification of Material by Nondispersive X-Ray Fluorescence Spectroscopy using Si(Li) Detectors and Ractioisotopic Sources", Proc. Eighth Symposium on Nondestructive Evaluation in Aer> space, Weapons Systems, and Nuclear Applications, San Antonio, Texas (1971 ). _

63. ' G.D. Atkinson, Jr., and S.J. Gage," Uranium Assay by Delayed Gama Ray Analysis Following Cf-252 Neutron Interrogation", Proc. Twelf th Annual Meeting Institute of. Nuclear Materials Management, Plam Springs, Florida (July 1971).

900l3042 I

i

l 34-E 6

1 I

64.

S.J. Gage, E. Linn Draper, Jr., G.D. Bouchey, and R.R. Day, " Design i

, and Construction.of a Versatile Cf-252 Source Shield and Experimental Facility",

Neutron Sources and Applications, CONF-710402, Vol. 2, Proc. of ANS Topical

+

Meeting, Augusta, Georgia,Tp iT 19-21, 1971.

J

65.. D.G. Jopling and S.J. Gage, "Pslic Resistance to Nuclear Reactor Siting",

Nuclear News,' 14:3, 32-35 (March 1971).

66.

J.B. Whitworth, G_.D. Atkinscn, and S.J. Gage, "Some Recent Applications of Nuclear Analysis Techniques to Typical Forensic Evidence" 23rd Annual Pro-gram American. Academy for Forensic 9:iences, Phoenix, Arizona (February 25, 1971).

67.

G.D. Bouchey, E. Linn Draper, Jr., B.V. Koen, and C.S. Beightler,

" Multiple Foil Activation Spectrum Determination Using a Numerical Direct Search Technique", Trans. Am. Nucl. Soc., Vol. 14 2, pp. 667-668, (October 1971).

68.

G.D. Bouchey, B.V. Koen, and C.S. Beightler, "The Optimization of Nuclear Systems by Geometric Progranming, Nucl. Sci. and Engr. 44, 267-272 (1971).

69.

G.D. Bouchey, B.V. Koen, and C.S. Beightler, " Optimization of Nuclear Materials Safeguards Sampling Systens by Dynamic Progranming", Nuclear Technology 12, 18-25 (1971).

70.

S.J. Gage, G.D. Atkinson, Jr. and G.D. Bouchey, " Cyclic Neutron Activation

. Analysis with a Cf-252 Neutron Source", Trans. Am. Nucl. Soc., (October 1971).

71.

E. Linn Draper, Jr., " Integral Reaction Rate'vetermination Part I:

Tailored Reactor Spectrum Preparation and Measurement", Nuclear Science and Engineering, 46., 22, (1971).

72.

E. Linn Draper, Jr., " Integral Reaction Rate Determinations Part II:

4_6.,31,(1971).

6 Fission Rate Measurements", Nuclear Science and Engineering, 73.

G.D. Bouchey and S.J. Gage, " Detection and Location of Leaking TRIGA Reactor fuel Elements", Nuclear Technology, 10, 211-214 (1971).

74.

G.D. Bouchey and S.J. Gage, " Neutron Radiography with a Small Subcritical Reactor", Int. J. of Nondestructive Testing, 2_,335-353,(1971).

75.

G.D. Bouchey and S.J. Gage, "The Economics of Subtritical Radiography",

Trans. Am. Nucl. Soc., 14, 123 (1971).

176.

G.D. Bouchey, E. Linn Dra per, Jr., and S.J. Gage, " Neutron Radiography with Cf-252: The Effect of Tailoring Neutron Energy Spectra on Photogrpeic Images", Neutron Sources and Applications, CONF-210402, Vol. 3, Proc. ANS Topical Meeting, Augusta, Georgia 3pril 19-21,1971.

90013043

1 j.

35 j

l 77.

G.D. Atkinson, Jr., J.B. Whitworth, and S.J. Gage, " Computer-Assisted

~

Analysis of Gama-Ray Spectra", Computer Physics Communicrations,-h 40-46 (1971).

78.

S.J. Gage, E. Linn Draper, Jr., and G.D. Bouchey, "Recent Developments -

in Radioisotopic Source Neutron Radiography", Proc. Eighth Symposium on Non-destructive Evaluation in Aerospace, Weapon Systems, and Nuclear Applica-tions, San Antonio, Texas (1971J T 79.

G.D. Atkinson, Jr., " Nondestructive Uranium Assay by Delayed Gama Ray Analysis Following Californium-252 Neutron Interroga$. ion", Ph.D. Dissertation, The University of Texas,183 pp., August 1971.

80.

G.D. Bouchey, "The Optimization of Nuclear Systems", Ph.D. Dissertation, m -

The University of Texas, E31 pp., August 1971.

81.

J.B. Whitworth, "The Development and Application of a Systematic Approach -

to Elemental Analysis in Forensic Investigations", Ph.D. Dissertation, The Unive'rsity of Texas,' 223 pp., December 1971.

82.

J.J. Chromik, " Experimental Datermination of the Neutron Flux in the University of Texas Californium-252 Irradiation Facility", Masters Thesis, Mechanical Engineering Department, The University of Texas, 85 pp. December 1971.

E. Linn Draper, Jr., Mary Elizabeth Foster and G.D. Bouchey, "X-Ray 83.

Fluroescence Analysis and Neutron Activation Analys's in an Analytical Chemistry Laboratory", presented at the Combined Meeting of the Texas Association for Ra'diation Research and South Central Photobiology Group. Houston, Texas, November 5-6, 1971.

84.

E. Linn Draper, Jr. and G.D. Bouchey, " Utilization of a Pnrtable Cali-fornium-252 Source for Neutron Activation Analysis and Neu;run Radiography".

j Presented at the Combined Meeting of the Texas Association for Radiation Research and South Central Photobiology Group, Houston, Texas, November 5-6, 1971.

j 85.

E. Linn Draper, Jr. and J.J. Chromik, " Production and Measurement of a Reference Spectrum in a Versatile F<perimental Facility" Trans. Am. Nucl.

Soc., Volume 15,:1, p.157,1972.

86.

E. Linn Draper, Jr. and Andrzej H. Pradzynski, " Identification of Alloys by Energy Dispersive X-Ray Spectroscopy", Ninth Symposium on Nondestructive Evaluation (1972).

87.

M.B. Owen, " Fuel Management Using Dynamic Programming", Masters Thesis Mechanical Engineering Department, The University of Texas, 59 pp. May 1972.

88.

C.E. Brauer, " Thermal Neutron Radiography with a Lithium-lead Collimator-Filter", Masters Thesis Mechanical Engineering Department, The University of Texas, 64 pp.., May 1972.

4 90013044

36 89i_

J.L. Macdonald, " Heuristic Learning Control for Nuclear Reactors", Masters

. Thesis, Mechanical Engineering Department, The University of Texas,131 pp.

August 1972.

'y 90.

J. Freim, " Theoretical and Experimental Evaluation of Nuclear Data and Calculation Techniques for Fusion Reactor Blanket Design", Ph.D. Dissertation, The University of Texas, 210 pp., December 1972.

91.

S.G. Barbee, "Neutronic Calculations in a Simulated Fusion Reactor Blanket", Masters Thesis, Mechanical Engineering Department, The University of Texas, 259 pp., November 1972.

92.

D.G. Anderson, " Fission Product Mass-Yield Measurements from Intermediate Energy Neutron Fission of Plutonium-239 and Plutonium-241", Ph.D. Dissertation, Th University of Texas,125 pp., December 1972.

93.

D.M. Williams, " Identification of Thermal Feedback Parameters for a TRIGA Mark I Reactor", Masters Thesis, Electrical Engineering Department, The University of Texas, 53 pp., December 1972.

94.

G.D. Atkinson, Jr. E. Linn Draper, Jr., and G.D. Bouchey, "Subcritical TRIGA Reactivity-Measurements Using the Source Jerk Technique", TRIGA Owner's Conference II, College Station, Texas (1972).

95.

G.D. Atkinson,- Jr., and E. Linn Draper, Jr., " Transient Rod Failure in a Pulsing TRIGA Mark I Reactor", TRIGA Dwner's Conference II, College Station, Texas (1972).

96.

G.D. Atkinson, Jr., "A Safeguards Minicourse",18th Annual Meeting of the_ American Nuclear Society, Las Vegas, Nevada (1972)

97.. G.D. Atkinson, Jr., E. Linn Draper, Jr., G.D. Bou ey, and S.J. Gage,

" Radioisotopic Source Amplification Using a Heterogene. s Subtritical Assembly",

Proc.18th Annual Meeting of the American Nuclear Society, Las Vegas, Nevada (1972).

98.

E. Linn Draper, Jr., and G.D. Atkinson, Jr., " Transient Rod Failure in a Pulsing TRIGA Mark I Reactor", published in proceedings of 2nd TRIGA Owner's Conference, February 1972.

99.

E. Linn Drapg, Jr..

John W. Davidson, S.J. Gage, G.D. Bouchey, "A System for Reduction of A Release from a Research Peactor Facility", Trans. Am.

Nucl. Soc., Vol. 15:1, p. 4-5, (1972).

100.

E. Linn Draper, Jr., et.al., "Staridard for the Development of Technical Specifications for Research Reactors", Trans. Am. Nucl. Soc., (1972).

101.

E. Linn Draper, Jr., G.D. Atkinson, Jr., and B.B. Tomlin, "A Radiography and Capture Gamma Ray Facility for Californium-252" Proceedings of the American Nuclear Society " Applications of Californium-252" National Topical Meeting, September 11-13, 1972.

90013045

37 102.

E. Linn Draper, Jr., G.D. Bouchey, G.D. Atkinson, Jr., and S.J. Gage, "A Versatile Subtritical Assembly for Undergraduate Nuclear Engineering Instruction", Proceedings of the Ameri un Nuclear Society " Applications of Californium-252" National Topical iket ing, September 11-13, 1972.

~

103.

E. Linn Draper, Jr., and S.J. Gage, "The Fusion-Fission Breeder:

Its Fotential in a Fuel Starved Therrml Reactor Economy", 93rd Annual Meeting of the ASME, New York, New York (197?).

104.

E. Linn Draper, Jr., "Technolof cal Innovation and Assessment: A Novel Course for Nuclear Engineering". Winter Mceting of the American Nuclear Society, November 12-16, 1972.

105.

D.T. Hall, E. Linn Draper, Jr., and P.S. Schmidt, " Management of the Transition to Nuclear Power Generation", Technical Report ESL-3, Er.ergy Systems Laboratories, College of Ensineering, Tim University of Texas at Aastin, December 1972.

106.

P.S. Schmidt and G.G. Park, " Heat Diss ipation in a Power y ant Cooling Bay", ASME, Paper No. 72-WA/HT-61, 'lovetter 1972.

107; P.S. Schmidt and G.P. D' Arch, " Entry Region Efferte on Fiow and Pressure Drep of Lithium in Fusion Reac tor Blanko ", Proceedin:;s of tie Texas Sympcsium on Technology of Controlled Thermonucleer Fusior, uperiments ?.nd Engineering Aspects of Fusion Reactors, Austin, Tea (November 2042,1972).

108.

E. Linn Draper, Jr., Charles Brauer, " Lithium-Ledd Collimator Fabrication for Radioisotopic Source Neutron Radioc,raphy," Trans. Am. Nucl. Soc., Vol. 15:1,

p. 142-143,(1972).

109.

E. Linn Draper, Jr Jves i?

'ec.

" Theoretical and Experimental Eval-uation of Nuclear Data and Calculatict: icnhniques for Fusion Reactor Blanket Design", Texas Synposium on the Technning) of Controlled Thermonuclear Fusion Experiments and the Engineerir.g Aspec t<

M Fusion Rex tars, November 20-22, 1972.

110.

E. Linn Draper, Jr., " Status of E W Helated Integral Experiments" pre-sented at the conference on "Nuci o Da % snd Neutronic, of CIP Blankets" held in Seattle, Washington, Septe+e ;;-o,.372.

111.

E. Linn Draper, Jr., "Fusico Srtar Engineerirg in thc Nuclear Engineering Curriculum at The University of Texas at Austin", Trars & Nucl Soc.

(1972).

112.

E. Linn Draper, Jr., R.J. Gage, T'r" Fu s i on-F i s s. or-Breeder:

Its Patential in a Fuel Starved Thermal Reactor Econr f, presented at the i'exas Symoosium on the Technology of Controlled Thmortuclear Fusion E> per im nts ar.d the Engineering Aspects of Fusion Peactors, Navember 20-2?, 1972.

113.

James 8. Freim, E. Linn Draper.

"Experimenal Detemination of the Fusion Spectrum in Graphite", Trans. Am. Nucl. Soc., (1972).

90013046

38 114.

G.D. Atkinson, Jr., S.J. Gaye, G.D. Bouchey, "Lyc l ic Ac t iva tion with a Californium-2b2 Source", Nuclear Jechnplogy (1972).

115.

G.D. Atkinson, Jr., "What You Always Wanted to Vmow About Californium j

Source Facilities", invited Ppaer, National Topical Meeting on the Applications of Californium-252, Austin, Texas (1972).

116.

T.L. Bauer, G.D. Atkinson, Jr., " Discrimination Petween Plutonium and Uranium by Ganma Ray Analysis Following Cf-252 Interrogation", Nationc1 Topical Meeting on the Applications of Californium-252, Austin, Texas (1972).

117.

E. Linn Draper, Jr., Editor, Proceedings of_ Texas Sy gosium on the Tech-nology.ft_ Controlled Thermonucippr Fusion _E,xperiments and the Engineering f

A,specf_s of Fusion Reactors, pub) r,hed by USAEC.

118.

E. L inn Dra per, Jr., Editor, Prog edings of the implications of Nucle _ar_

Power in Texas, published by the Texas Atonic Energy Research Foundation.

119.

E. Linn Draper, Jr., J.R. Dten, J.J. Chromik, " Measurement of the Integral Fission Cross Section of Th-232 in a Cf-?L2 Fission Neutron Spectrum,"

Trans. Am. Nucl. Soc. (1973).

120.

D.G. Anderson, E. Linn Dreper, Jr

" Fission Product Mass-Yield Measure-ments From Intermediate Ener gy Neut ror Fission of Plutonium-239 and Plutonium-241", Trans. Am. Nucl. Soc., 1973.

121.

E. Linn Draper, Jr., and Ja v, 9 Freim, "Exrerimental Determination of the fusion Spectrum in Graphit<

f ra n :, la. Nucl.

x i6, 9, '1973).

122.

E. Linn Draper, Jr.,

"Fu,ian Rmct:

Engi neer i'.o in the Nx lear Engineer-ing Curriculum at The Universi*s of

, a t Au st i n", Trans. %

.16, 16 (1973).

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~Nucl. Soc.,

123.

E. Linn Draper, Jr., Thea w : A N rish, and V ian 1 McArdle "A Neu-tronic-Photonic Comparison of Va md i:.

and Niobium Ccotair,ing Fusion Reactor Blankets", Trans. Am. Nucl. Soc (Novmber 1973).

124.

John H. Vanston, Jr..

"U<. cf N.itive Analytital forecasting (PAF)

Techniquer, for Fusion Developo nt A n e. y :, i s ", T ra n s. Am. Nucl. Soc., (November 1973).

125.

Theodore A. Parish and L i. inn Draper, Jr., "fieutronic and Photonic Analyses of fusion Reactor Blankets Containing Thocium," Fiftn Symposiun on Engineerin9 Problems of Fusion Research, Pr:nceton, tai Jersey, November 5, 1973.

126.

C.E. tocke and D. R. Paui, "Graf* Copolymer Modification of Poly-ethylene-Polystyrene Blends.

I. Graft Preparation and Characterization" J_ournal of Ayylied Polp er Sciene, Vol 17, pp. 2597-2617 (1973.)

u.

900l3047

39 127.

C.E. Locke and D.R. Paul, "Gra f t Carolymer Mndification of Poly-et hylene-Polyst yrene Blends. II Pn pert ies of Modificd Rlonds", Journal of

!q/1!

App i ied Po lyy. i % s enc e, N 1.

1, pp

>i uh10 1 128.

J.R. Deen, " Measurement of Fin ion Product Yields from Thorium-232 in a Californium ~-252 Fission Neutron Spec trum", Ph.D. Dissertation. The Uni-versity of Texas at Austin,141 pn., (May 1973).

129.

L.D. Hansborough, "Overall Tritium Considercticos for Controlled Ther-monuclear Reactors", Masters Thesis, The University of Texas at Austin, 154 pp. (May 1973).

130.

"M.E. Senglaub, " Cross Section Studies Based on the Statistical Model",

Masters Thesis, The University of Texas a t Austin,109 pp., (August 1973).

131.

E. Linn Dra per, Jr., M.J. Voitin, Jr., J.L. Macdonald, C.T. Rombough, L.D. Honsborough, 5.G. Barbee, and J.H. Vanston, Jr., "A University's In-volvement in Municipal Decision-Making on Nuclear Power", Trans. Am. Nucl.

S_oc.., (19 73 ).

I 132.

E. Linn Draper, Jr., J.L. Macdondid, and M.J. Voltin, Jr., " Nuclear vs.

Coal: An Economic Comparison of Po.<er Piant Economics in Texas", Trans. Am.

Nucl. Soc., (1973).

133.

R.E. Henry, "Forer sic Applicat t: ns of Neutron Activation Analysis",

presented at the Combined Meetirq nf

  • x lexas Association for Radiation Research and South Central Photabiology Gcoup, San Marcos, Texas, November 9-10, 1973.

a tivation Analysis to the 134.

G.D. Atkinson, Jr.,

'ApNiot,:rc of Neutron c

life Sciences", presented at r*,

L' S:n d Meeting of tne Te m Association for Radiation Research W Wuth '

Mi Photobiolom Group. Mn Marcos, Texas,

November 9-10, 1973.

! uct> > indtion of Neutror f er mi Age f rom 135.

S.P. Nichols, "Experimenti Cali fornium-252 Fission Spcctrr tc ' ndrie Covered indic Resonance in a Graphite Medium" Masters Theri, Se Un.ersity of To as n Austin,101 pp.,

January 1974.

13fn T.A. Parish, "Neutornic v ? % teri-Analyses of Simulatcd Fusion Reactor Blankets Containing Thorit ' un %

  • s o '

aniuf, Ph D. Div,0-tation, The University of Texas at Austin, 329 ep January 1974.

137.

J.H. Vanston, Jr., "H e of the Part;tive Analytical forecasting (PAF)

Technique for Analysis of the Effects of Various Funding and Administrative Strategies on Nuclear Fusion Power -lant Development", Ph.D. Dissertation.

The University of Texas at Austin, 459 op., January 1974 138.

E.M. B. Sorensen, " Thermal Eftm ts on the Biolcgical M y nification of Arsenic in Green Sunfish, leponit Cyanellus", Ph.D. Dissertation, The Univer-sity of Texas at Austin, 233 pp,, hy 1974.

900l3048

40 139.

E. Linn Draper, Jr., and J.R. Deen, " Measurement of Fission Product Yields from Thorium-232 in a Califori.ium-252 Fission Neutron Spectrum", Trans. Am.

~~

Nucl. Soc., 17, 531 (1973).

140.

E. Linn Draper, Jr., M. Etz ion, S.P. Nichols and W.G. Davey, " Neutron Fermi Age in Graphite from Fission and Fusion Sources to Indium Resonance",

CONF-740402, USAEC, (April 1974).

141.

E. Linn Draper, Jr.. and I.A. Parish, "Neutronic and Photonic Analyses of Fusion Reactor Blanket s bnta ;ong Natural Uranium", CONF-740402, USAEC, (April 1974).

142.

G.D. Atkinson, Jr., B.D. Ad ms, and S.J. Gage, "A Programmable and j

Automated System for r,m a an ! F aay Analysis", PR0g. IEEE 1973 NUCLEAR SCIENCE SYMPOSIUM, San f ranc isc o, "a li fornia (19T3T.

143.

G.D. Atkinson, Jr., and R.E Henry, " Neutron Activation Analysis.

Environmental and Biologir.a1 Apriications", Sixth Annual Meeting of the Texas Association for Radiation Re,earcn. San Marcos, Texas (1973).

144.

M. Etzion, R.G. Spangler, E. Linn Draper, Jr., " Multiple Foil Activation Measurement of the Californium-252 Fission-Neutron Spectrum, Trans. Am. Nucl.

Soc., (October 1974).

A. H. Pradzynski, " Determination of Selenium in Water on the ppb Level" 145.

presented before the Texas Association for Radiation Research, Dallas, Texas, (November 22,1974).

146. Thomas L. Bauer, "Discriuination of Uranium-235 and Plutonium-239 by Cyclic Activation and Delayed G am3 Ray Analysis Using Californium-252 as a Neutron Interrogation Source", %sters Thesis, Mechanical Engineering De-partment, The University of Tm as at Austin,178 pp. (August 1974).

147. Olan D. Thompson, " Opt m in tion of Shipping Containers for Radioisotopic Neutron Sources", Masters Thesis, Mechanical Engineering Department, The Uni-versity of Texas at Austin, 33 a, (August 1974).

148.

J.R. Deen, E. Linn D u p:-

Jr., " Measurement of the Fission Product ion Cross S : tion of Thorium-232 in a Cali-Yields and the Energy Int w it fornium-252 Fission-Neutron Srictr m", Nuclear Technolony., 25, 416 (?975).

149.

E. Linn Draper, Jr., T.lt N rish, M. Etzion, " Utilization of a Small Accelerator for Fusion Reactor f.lantet Design", Proceedings of the Third Small

~

Accelerator Conference, USALC, CDNF--741021 (19 /4).

150.

R.G. Spangl er, E. L i nn Dra pe r, Jr., T.A. Parish, "14 MeV Cross Section Measurements of Threshold RNc tions for Seven Metals", Trans. Am. Nucl. Soc.,

22., 818 (November 1975).

90013049

41 1 51.

W.R. Smith, Jr., E, Linn Draper, Jr., " Measured and Calculated Fast Neutron Spectra in a Graphite Medium". Trans. Am. Nucl. Soc., 21, 800 (November.1975).

1 152.

J.W. Davidson, E. Linn Draper, Jr., " Costs for' Partitioning Strategies Involved in High-Level Nuclear Waste Management", Trans. Am. Nucl. Soc., 22, 348 (November 1975).

~~~

153.. M.J. Voltin, Jr., E. Linn Draper, Jr., " Sensitivity of Total Fuel Cycle Cost to Variations in Enrichment Tails Assay Strategies", Trans. Am. Nucl. Soc.,

l 22, 322 (November 1975).

154.

T.A. Parish, J.W. Davidson,.E. Linn Draper, Jr., " Transmutation of Fission Products in Fusion Reactor Blankets", Trans. Am. Nucl. Soc., ~22, (November 1975).

~~

x l

155.

T.A. Parish, J.W. Davidson, E. Linn Draper, Jr., "The Effects of the D-T Fusion Neutron Energy Spectrum on High Energy Reaction Rates", submitted

.to the Sixth Symposium on Engineering Problems of Fusion Research, San Diego, California (November 18-21, 1975).

156.

A.H. Pradzynski, R.E. Henry, J.L.S. Stewart, " Determination of Selenium in Water on the ppb Level by Coprecipitation and Energy Dispersive X-Ray Spectrometry", Radiochem. Radioanal. Letters, 21(5) 277-285 (1975).

157.

B.E. Bulla, E. Linn Draper, Jr., R.E. Henry, M.J. Voltin, Jr., et.al.,

Texas Nuclear Power Policies: A Study of Alternatives, Volume II: Methodology.

The University of Texas at Austin Center for Energy Studies, Policy Alternative Study No. 1 (1975).

I l

158.

A.H. Pradzynski, R.E. Henry, J.L.S. Stewart " Determination of Transition Metals by Radioisotope-Excited Energy Dispersive X-Ray Spectrometry",

Trans. Am. Nucl. Soc., 21, No. 3 34-35 (1975).

159.

A.H. Pradzynski, R.E. Henry, J.L.S. Stewart, " Nondestructive Oftermination of Toxic Elements in Toys", Proc. of 10th Symposium on Nondestructive Elements, San Antonio, Texas, 257-265 (April 23-25, 1975).

160.

R.E. Henry, " Determination of ppb Levels of Selected Elements in Natural Water Using Radiosiotope-Excited Energy Dispersive X-Ray Fluorescence Analysis",

presented at the Eighth Annual Meeting of the Texas Association for Radiation Research, Austin, Texas (October 31 -- November 1,1975).

161.

S.P. Nichols, " Application of the Partitive Analytical Forecasting (PAF)

Technique to the United States Controlled Thermonuclear Research Effort,"

Ph.D. Dissertation. The University of Texas at Austin (December 1975).

162. - C.T. Rombough, "The Total Energy Investment in Nuclear Power Plants",

Ph.D. Dissertation The University of Texas at Austin, (January 1975).

90013050 J

42 163.

J.L. Macdonald, "Investiga tion of Pattern Recognition Techniques for the Identification of Splitting Surfacn in Monte Car'o Particle Transport Cal-culations", Ph.D. Dissertation, The Ur.iversity of Texas at Austin ( August 1975).

164.

J.W. Davidson, "A Cost-Benefit Analysis for Partitioning Strategies In-volved in High-Level Nuclear Waste Management", Masters Thesis. The University of Texas at Austin, (Me 1975) 165.

T. A. Parish, J. W. Davidsort, and E. Linn Draper, Jr., "The Pintrazation of the Hazard Resulting from Transmutatico of Fission Products," Transaction, of the American Nuclear Soc iqty, 23, 59, J.me 1976.

166.

i. A. Parish, " fusion-Fission Hybrid Studies at The University of Texas,"

U.S.-U.S.S.R. Symposium on Fusion-F issien Reactors, Lawrence Livermore Labora-tory, July 1976.

T. A. Parish, J. W. Davidson and E. Linn Draper, Jr., "Negn 167.

ronic Perfor-90 and I 9,"

Second mance of Graphite Fusion Peactor Clard ets Containing Sr ANS Topical Meeting on the Tecnnology

.,F Controlled Thermonuclear Fusion, Richland, Washingtcn, September 1976.

168.

T. A. Parish, J. W. Davidson and J. B. Cornwell, "The Effectiveness of a Sr90 fusion Reactor Transrutation b ste Management Progran " Transactions of the American Nuclear society, M, hember 1976.

169.

A. H. Pradzynski and J. R. RnrA, " Development of Synt hetic Standard Samples for Trace Analysis of Air ic ri' ilates," ASTM scecial Technical Publication No. 598,1976, pp

%E 170.

A. H. Pradzynski, -

E Hm y a d J. S. Stmer, De terni r.a t ion of PPB Concentrations of Transition S tai-by Eadioisotopa-Escitea incrgy-Dispersive X-Ray Spectrometry, Journal of Wimnly tical Chemi c ry, g, 1976, p. 219-26.

171.

A. H. Pradzynski, P L. " e n r y a r, '

L, Dra wr, Jr., "Dr arnins lia o r PPB Concentrations of Uranium. Thre :e ind Malybderm in We t er using /M Preconcentration and Radioisotope & cited X-Pay Emission Srectromtry, Froceedings of ERDA Sy posiv m ma - Ra y M u rc ' < e r<d A p pl i e n i om..

Ann Arbor, Michigan, May h i, !bt, ;

175 177.

172.

A. H. Pradzynski, R. r N r. r.

L. Dr m ", Jr., ' Octemina tion of 4

Trace Elements of Hydrogeocher ical hospacting by AFDC-Copm :pitation and X-Ray Spectrometry," invited p ner at 'ho International fanference on World Nuclear Energy a Status Repcri.

7 re re. > : tions of Am. Nuclear society ~, 24, 1976, p.119.

~

173.

R. R. Gay, G. F. Broc.kett and P

1. Johnson, "Tric-Phase Flow Measurement Techniques for Nuclear Safety Researc h," Two-Phase Flew and Heat Transfer Symposium-Workshop, Miami Beach, Flr ica (1976).

174.

C. W. Savery and R. R, Goy, "Lffect of Entrained Droplet Phase upon Predicted Compartmental Pressures in Nuclear Containtrents," Two. Phase flow and Heat Transfer Symposiun-Workshop, Miami Beach, Florida (1976),

90013051

43 175.

R. R. Gay." Reactor Hydrodynamics During the Reflood Phase of LOCA,"

accepted for publication by Nuclear Technology.

(Also an EPRI special report).

176.

E. M. B. Sorensen, J. S. Johnston and R. H. Richardson, "An Autoradio-graphic Approach to the Heavy-Metal Labeling of Drosophilia Melanogaster for Capture-Recapture Studies."

(Publication in Preparation,1976) 177.. E. M. B. Sorensen, R. E. Henry and R. Ramirez-Mitchell, " Time Dependent Localization of Arsenic in Subcellular Liver Fractions."

(Publicationin Preparation,1976) 178.

E.'M. B. Sorensen and R. E. Henry, "Dist'ribution Pattern of Arsenic in Fish During Acute Experimental Exposures."

(Publication in Preparation,1976) 179.

T. L. Bauer and E. Linn Draper, Jr., " Linear Least-Squares Peak Search Algorithm", ANS Topical Conference on Computers in Activation Analysis and Gamma-Ray Spectroscopy. May 1-4, 1978.

180.

D. E. Klein, S. R. Bull, and J. B. Miles, " Flow Visualization Around GCFR Fuel Rod R'ughness Elements",Trans. Am. Nuclear Soc., 28,, June,1978.

181.

D. E. Klein, S. R. Bull, and J. B. Miles, " Pressure Drop for GCFR Fuel Rod Roughness Elements", Trans. Am. Nuclear Soc., 30, November 1978.

90013052 e

e

1 E, g 'j

,g-(;.

,.4e a

4

- -f.,t j

e

.. ]

[

.;bW j,.

>> t -

,, a 1

i

.I 4

3 4

1 NUCLEAR REACTOR i

LABORATORY 90013053 TECHNICAL REPORT 4

f THE UNIVERSITY OF TEX AS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING

.i TECHNICAL INFORMATION AND HAZARDS

SUMMARY

REPORT

~

FOR A TRAINING, RESEARCH, AND ISOTOPE-PRODUCTION 250 KW, PULSING NUCLEAR REACTOR AT 4

THE UNIVERSITY OF TEXAS

~

AUSTIN TEXAS 78712 L

90013054

!:l December 1978 he-

CONTENTS FOREWORD 1.

INTRODUCTION............................

I 2.

LOCATION AND GENERAL F.EATURES OF THE SITE 3

~

2.1.

General Location....................'...

3 Surrounding Activities and Population 3

2.2.

2.3.

Meteorology 10 2.4.

Geology and Hydrology Il 2.5.

Seismology...........................

18

~

3.

DESCRIPTION OF BUILDING AND REACTOR 20 3.1.

Reactor Laboratory...:...................

20

~

3.2.

Reactor Pit.......;.................

25 3.3.

Reactor Core.........................

26 3.4.

Reactor Reflector 28

~

3.5.

Irradiation Facilities....................

29 3.6.

Control Rods and Drives 30 3.7.

Instrumentation 35 3.8.

Cooling and Water-treatment System..............

42 3.8.1.

Secondary Cooling Systems 42 3.9.

Core Physics 42 l

3.9.1.

Critical Mass.....................

45 3.9.2.

Void Coefficient 45 3.9.3.

Moderating Properties of Zirconium Hydride 45 3.9.4.

Temperature Corfficient.................

46 3.9.5.

Reactivity Perturbations 46 4.

REACTOR OPERATIONS 48 820l1009 90013055

4 4.1.

Legal Requirements......................

48 4.2 Initial Loading and Start-up.................

48

,4.2.1.

Operational Limitations 48 4.2.2.

Operational Procedures................

49 4.3.

Routine Operational Procedures................

50 4.4.

Health-Safety Procedures...................

61 4.4.1.

Access to Laboratory.................

51 4.4.2. Materials Controls..................

51

~~

4.4.3.

Health Physics....................

52 4.5.

Organization.........................

53 4.5.1.

Reactor Committee 53 4.5.2.

Radiation Safety Committee..............

55 5.

POTENTIAL HAZARDS 57 5.1.

Hazards Associated with Operation of the Reactor.......

57 j

5.1.1.

Soil Activation 58 5.1.2.

Radioactive Contamination of Shielding Water.....

58 5.1.3.

Production of Radioactive Gases by the Reactor....

59 5.1. 4. Reactor Power Transients...............

60 5.1.5.

Loss of Shielding and Cooling Water 62 5.1.6.

Production and Handling of Radioactive Material 64 5.1.7.

Radiation Dose Rates Around Reactor 65 5.1.8.

Reactivity Hazards Associated with Experimental Failure 67 5.1. 9.

Fuel El ement Failure.................

67 5.1.10. Adequate Steady State Cooling 69 i

5.1.11. Calculated Maximum Fission-Product Release After a Fuel El ement Failure...............

69 5.1.12. Calculations for Loss of Reactor Pool Water 77 11 90013056 2 202fO(W s

l I

l

b la 1

5.1.13.

Argon Activation in Reactor Water........... 85 5.2.

Accident's.Not Associated with Operation of the Reactor..... 90-u.

i 5.2.1.

Mechanical Damage to the Reactor............

90 l

5.2.2.

Failure of Utilities.................

30

)

5.2.3.

Fire..........................

4 t-1 5.3.

Design Basis Accident 90 5.4.

Emergency Procedures......................

93 References................................

98

., W i

90013057 c.

w t

'w hise w

a M

4 4

6 4

e-N -

t e

< w 4,;

'l'.

l

  • s u,'

e

g FIGURES 1.

Map of Austin and Vi cini ty............'........

4 2.

Map of University of Texas Campus 5

3.

Population Density of Austin...................

6 4.

Population Density of Travis County 7

5.'

Plan of Taylor Hall 8

6.

Plan of Nuclear Reactor Laboratory................

9 7a. Me teo rologi cal Summa ry......................

12 7b. Meteorological Summary......................

13 7c. Me teorol ogi cal Summa ry......................

14

8. Surface Wind Roses........................

15 9.

Plan and Elevation of Pit 23

10. ReactorandSPit)b.!f)bk.....................

24 11.

Fuel-moderator Elenent......................

27 I.

12. Shim and Regulator Control Rods and Drives............

31

13. Transient-rod Drive Schematic 33 14.

Photograph of Transient-rod Drive 34

15. Block Diagram of Instrumentation.................

36 16.

Control Console 40

17. Water Systems 43

.......s

18. Water Systems 44
19. Organizational Chart.......................

54 20.

Maximum Fuel Temperature Versus Time After Complete Water Loss (250 kw Operating Power) 83 21.

Dissociation Pressure Isochores of Zirconium Hydride (Expressed as H/Zr Ratios)................

86 1

22. Two-dollar Reactivity Transient 92 t

iv 90013058 i

~

FOREWORD An analysis of the hazards that might arise while operating the TRIGA Mark I pulsing reactor is presented in this. report.

In order to assure : hat the analysis is conservative, it has been assumed that the reactor nas bean operating for a long time at a constant power level of 250 kw. Aiso, tha

~

design of the relatively inaccessible below-ground tank has been cased usan an assumed steady-state power of 250 kw.

The operational safety of the reactor results from an ' inherent self-regulating characteristic of the core. This self-regulation is obtained from the prompt negative temperature coefficient, which is a property of the homo-

~~

geneous uranium-zirconium-hydride fuel-moderator elements that fonm the reactor The inherent safety of the reactor is supplemented by careful procedures core.

adopted for the operation of the reactor.

On the basis of the hazards evaluation presented in this report, it can be assumed that operation of the reactor will not cause undue risk to the

~

health and safety of the staff or of the public.

l 90013059 I

~

v

%O

1.

INTRODUCTION This report is an update and modification of the Hazard Summary Report originally submitted in support of an application by The University of Texas

[.

at Austin for a Construction Permit and a Utilization Facility License to permit the installation and operation of a training, research, and isotope-

~

production reactor (TRIGA-I) that was purchased from the General Atomic Division of General Dynamics Corporation.

It includes the specifications for this reactor and an evaluation of possible hazards.

t The reactor. core, of a type developed by General Atomic *, uses zirconium hydride as the moderator. A large number of reactors of this type have been installed in both the U.S. and abroad in Universities and other research facilities. Many of these have been in continuous service for more than 15 years; the first was installed it. 1958.

The University of Texas at Austin

)

reactor went critical 1963.

A comprehensive test program and long experience have conclusively demonstrated this reactor's inherent safety, which is due to its prompt negative temperature coefficient of reactivity. The reactor installed at The University of Texas is equipped with conventional safety rods and electronic scram equipment.

Initial loading and start-up of The University of Texas reactor was

~

performed by General Atomic personnel. University of Texas personnel were trained at General Atomic in the operation and mairtenane.e of the reactor.

During the past years a continuous training program ivr new personnel at the IdO(IUOk University of Texas at Austin has been in existence.

  • General Atomic is now a joint venture of Gulf 011 Co. and a subsidiary of Royal Dutch Shell.

90013060 t

2

.The TRIGA family of reactors was developed by General Atomic Division of J J General Dynamics Corporation for use by universities and research institutions

'~

~

as a general-purpose research and training facility.

!.-~

The TRIGA-1 pulsing reactor utilizes the TRIGA core with pulsing fuel-moderator elements. The reactor is licensed for steady-state operation at a power level of 250 kw and for routine pulsed operation. The total loading of the TRIGA-I reactor system is 1.8% 6 k/k ($2.41) excess reactivity above a cold, clean, critical, compact condition.

Pulsed operation will be limited to rapid insertions of reactivity of up to $2.00. For this discussion, a pulse is defined as the step insertion of an amount of excess reactivity t

between 0.75% and 1.5% 6 k/k.

From past experience, it is concluded that the TRIGA reactor can be i

L operated at 250 kw steady-state power and can be pulsed up to a 1.5% 6 k/k

[,

transient without hazard to persons using the reactor or to the general public, provided normal precautions for handling radioactive materials are observed.

l' In addition, General Atomic has demonstrated by direct experiment on

-its prototype reactor that the TRIGA-type reactor is so stable that even rapid insertion of 3.1% 6 k/k reactivity causes no hazard to individuals near the reactor and in the surrounding area. After a power transient, the prompt negative temperature coefficient of the reactor limits the total energy release to a safe level.

90013061 u

M i_

080t100?

l 3

e 2.

LOCATION AND GENERAL FEATURES OF THE SITE 2.1.

General Location The reactor is situated near the center of the main campus of The University ofTexas,CityofAustin,TravisCounty, Texas (seeFigures1and2).

  • h reactor is located in a laboratory room in the mechanical engineering building, i

~

Taylor Hall (see Figures 5 and 6).

{

The campus is located on the high point of a gentle knoll.

The reactor is located on the east slope and about fifty feet below the crest of the knoll and about forty feet above Waller Creek, two blocks away. The reactor site is approximately 1.5 miles east, north, and west of branches of the Missouri Pacific Missouri Kansas Texas, and Texas New Orleans (Southern Pacific) rail-roads, 0.8 miles north of the Texas State Capitol building, 2.0 miles southwest.

of the Austin Municipal Airport, eight miles northwest of Bergstrom Air Force Base,1.7 miles north of the (Texas) Coloredo rdver, and 0.6 mile west of l

Interstate Highway 35.

2.2.

Surrounding Activities and Population L.

The 1978 population of Austin is 308,000, and the surrounding Travis County rural population is approximately 30,000. A total of approximately 330,000 people live within a 20-mile radius of the site.

It is estimated that there will usually be,approximately 40,000 people within a radius of one mile of the reactor site during normal working hours. Population den-sities are shown in Figures 3 and 4.

Austin is composed primarily of governmental, business, and professional I

persons and their families, with substantial light induc+ey and practically s

no heavy industry. The population has roughly doubled since 1960, and it is E

90013062 J

lh0Ll009

m l -l 4,'k?3h %

E f

i,

'. 4 ) (a m.....f..

  • / '

)

f' h

1:si.+.,

,n,.;

5. Q.f' [* ^..',f(, l,,,t q!

~

W I

p-

'A r.

t f.

. c.' /.

''"'Y*

N ht.ir.

dO Y tr

'a a-

/

N

(

6

% *..g j' ' Q:u, ff

," h {,

~. ' '

'(

,yl t,pt('s's.

e 4 f /'l' f s

  • 'f e 'i

' g,

'f

' y.k t ik, C'f,K.f[ ^.*%'.%..(;y'qhqh.

'y (f s.u, & )

f,

' ' ',, j s

l,

),'.C J

y s

g)j, y

'.r r

d Id//

' 01 [d

[

. [.

. ;..'.l./

V. w +, }d:)[.ri r,

7 s,

s. n ; W.L....,,
  • /7 '

/,'. A.,

..2

/

s

,,,,j y*

f,,

g

',+

i v

il,..

. f "q

.y, :.:

n u *i 'p.y,p'

.7, w') Q(.e

)y '

~

yr-lp

'.nyj

/.'

h*?:~~

.'. lh Q' s '? a $ & - { %;!n.y.f.,

&-...y')&h?s&Wjsh.l$,k,E'y.-(*

i,

't o

d., $h i

j s y j,

/

f*.

i

.Nr',;m ' [;/rs:'9., l' *;;

. G

&*,I[g' AI ' k f ,"4,* n[

'E-

,., gg[h /,

/

4g.

g,, y./.)(p/ )~s c!.ww y

1. w W e/r ig

-'4 W f f k ily ;rh.j" p-/,/,f{f9:ff? k'N0 ^ W,Ytkj g

eff A k(h. t" j!.

f*'

.g if N $ g. j p M M g 'V hl. $ $ $ s s g W #-

!d S

'I j,' r*.tf :

s) y s

'4 '

Q

'q YD.

.r*

. (} ',;,

.'V '

. Y l* ?

.n :..'h.;*>$ h ~ m t M

Y.'

d.

e-

.. ~. s,j ln?. a.'. r.,,,.?t

5. +:. *. !.

A,l.$:.:h.

'g'h,,.fM" i /t'g.a --

' gL ef T" 9

,f..

i

' U.$

J 4

g.

.&'*f,l 3,. k '/,.Yld. ' vOf Qf,,g,yj)

.d

'N

,e..- P \\'

'a

/ W ~k

. ;J M'"9 lC *.1

.,;:.. >Q~.",,, *h,f ' g

,.e ';*

.p-~

%l i

' f{'

O h,f *

.;.', i.,.

t,'

I j,,,",.

ia a.

  • a8 g.;,M
  • (, ;

g

'^'

'O?*4*f. ~ ) ('E ' ')

(

sb

%~5

, ' ') R '

,. { N'?. '. l.*

h

)'i.* '

l f,4

..t s,,.

f' d ; :lal.., [*j' f ;, 'c, f,? ? >i n :,,,';~ c - Q, ^ ~ <!)..

~, '

j '4 f.

.r f'h ):p'

)

,,.*'l [

1 l

.',s,: % % ,

j, '.,

j

q r ;.,

h g

f ll}.:.;, 4 M,W'..,*?,,$.im 'g,,4.f,k'% f' n.

e

*",.;-:lF'N,,f Q,." " ?

%,'~,,,1

"~',,/-

9; l*, /

t

' ! A'f,'o.; *.'h.'".t f*'

7'fr.ll/ [P D,p'.(!

  • a t

.t

' '$'[-

f*'*

. 3

e' i'

/,'p r,..

t.'

<[* '

' c.

i'8*',h,,f[,,,D.hNI';

[5'MQ[ y(,

-S,N[1I,h @@

d

.,h(./hY,b

,/

Q

,).N'.E N,~s 0

'l

,.h.

Y ~,." s {l. 'k ' hg r'

!,o y,.! $Yjl.hh o'

{ { 5 '

5 pll.*

,/

I f

I o

f,,I.

, A j o,' ll

,r.

' f' ;

i e t /, '.,'..

,\\

o

  • n:,.c ;

,'.n.,.. ;

am.. i's ll

~

,' l

.!.~ 'l,

.,. }

t.

,,.,,e y....

Msti. (p A'f,flN ANf' W,1NIIy 90013063

-~*"**-*m'

[

y I$

I.

IlQK I.I LIIl

'C 1

.s h

//

F

\\

f f

I Q Q !

ip I ]

%l r

, J', C,%

l 9fMm[i Nrv a

/7 f

I =j u

3 if l g7)3l i

!7 a M i

i Ig 9

i

,)4 I

j j

y=

= ; ;-

l*

I k 0 E D3bh,{g]..i&ldNi' BI

-..,rpo _

kAB IM,,,lg)5 __,l45/s/

L f

?

I, 1;

a

/~

l5 palPld!Kjl3 18 -lf

~

e l

r.M.~ll

.Omab,f;Mli^I'

/

G

{ {!

7 g

t!!I A U h,]l'3(fp}, _

l @ ]l I

/

s yg

__v x

/

2 0

/~

y

/

f L-

~&

~~

i n

g l,

F dd0lI00e Figure 2 g

POPUL ATION DENSlT Y 6

PERSONS PER ACRE

[

l 0-2 a.s.

0 I

AUSTIN. TEX AS

. ~

v'

&W h

,*<h

~> :::: u.

........6

-u f ::

s c

-v,p,#x ;;

8

/)

E

% llc::::::::n.::::

& l4

/;?' fx. ft r-e

..:.:. ::;:::x M

-Y a-J r

.s q -

q'.

,v

..:"j. T

.u

,Tn u

(

3+.&> W' 's J;.;n;.;;.

,s.

M, J '!!!!!!.!w!!.3 M :;::

i r

g AsSe fj. J f

1l/

pnu,,g.-...... 0..:.::.::.::.:.:.:::::::::=

e<:.!:.:.:.

. e.... ::'*,

s

\\

s.

a 9..:;4;?:;;;;;:......:.

g..::............ * '

4 ;'.:.:...:.:.::..,3.:.:.:.y.

ei

pm..

r".

.
.:i.n.i.:.:.7.:Y.:e.'Nw

-A p ::::::.t

,s

){q o

s S

.1

, y.

'n' 1

5k \\ ' ~ g,,.,.:.:.:.:.::..:.:.:.:.: C...'NF#. w

';v4 nk....x...

r-tu.:.....:.2.&>fpa..

i

,tyst :.:.::".:...~.7..'..:

^?.lg~ )kf. m:!;l.. ::::s,,

':1*g j,7 -

I'} -

..'. a

  • .:..-&,,. !$;'li!li.

.. e t

ll:!!:

I,, %

4.M e q.

d:]l:Y:'Q:t.. _j.

. &.s u.n!'.l.l.$., ff s,j s

.p

.t!

'%i%~,$',M.,.

s _a.!

,.1*:....,

f e'.

.:::::t.",

II.i!...u. :!!i!!!$@$lllillll

%.l.l.$.

,c l?!?!lll....., !llllln!!n.llF. '!::

s h;.

'Q)"

%,e !'i.:li...r..n..n. i.mll:lill:.:!!2

.. :i

':n!.!!l$...!rl!!n. l.V

~.

1 C:..:=

i....n.

  • :' s :

~~}:.'.

1

4 M

~

~

i t

i Figure 3 b60U 00(>

90013065

.I f

I I

l I

I l

i i

-t

?>

c W

C

(%1 a.

. O

~

/

N Austin, Texas SMSA Census Tracts: 1970 f

(Travis County)

G.

/

Trees Nordmed o

e s

v',,

7 c

'Q, E

l -

'*. l,,

-vy as. -

\\(

3 1&O1 -

1802 s

r'

}

2 l'.

."'.t.'

Tram Nonhece c

e

/

c

/s co 1702 4fl.o 7

,/

Trem Soud=.s

. J. !

.r s-f jg

>,, 1,,f 22

,-j

~ ~ -

~

, d,-

  • 2303, t 's.

y i

s 24 m

O BOUNDARY SYMBOLS

.O Census Tract P,vndaries-Trave Souheest TD-g cou ty s

c*$

~-

y J',/

corconste (=

c s

g Om=* Tracts g

Boundsrees Wegh Are Not Tracts.

Comorete tm e'

I

%J

i 1

I I

I

'I i

i i

1 i

.F 24 th STREET S!DE Pr:: s n n

107 L 10 3 101 Viocd Vicekmg -

}

'e. m o.

Furnst.

Sct:r 03 1 "u Shop 142 Room '

13 4 Ener;y o*

J 164 15 6

/

Lctorc cry Ce ill

.Vete'

.yetoi 32e-187-c;

!!7 00 1006

OOA
48A hS4A 640 Costings Therrno!/ Fluids F

C Stock

- [ l 158, Laborencry Laborofory 13 2 k

,3 l$',

Rm c-i g

19 Electronics lg I40 EII C

U Repair i

126 1000

oo
2 127 E

Manufacturing 130 Processes 185 TM 'C2 Nuclear M

143E.

Laboratory 125 IOOF 140 Ol Q.

i4g Laborotyy }

$O 148 G.'

h 183 A } ~

m i

L t

M_ E.

3 Classroom 102 M E.

2S Classroom 8

124 1.d Nuc*ect 131B 102 A

M.E.

133 t- -

126C '

131

, (68 Ccpocity)

Purchasing 13 0 (130 Cepccity )

36 183 Reactor to 4A 4

-e et

!O4 ISOA 1508 ISOC l1500150E 15 0 I 150J I

150F 15CG 150H

\\

Ce-fer Rr k

133 ui s

Jiuclear Pi Sqmo Fi tu to 135All35

8 Area Offc.e 2

181 na o

S o' g;is o

-Men COURTYARD

[

E Shop

. E. 10 5g. "E Energy /Ruids Undergraduate Print R Toa Sigma Areo Office Office Shop O

l37 o

W; /

Classroom (50Copccity)

E

\\

)

181 179 181 179 l

A A

B B

p

  1. 14 8 11 4 186 0 Men 122 l

P.S.I. Testing Laboratory 8

139 I

I12 7

f22C Center For 7

l-28

(

eI,y)

I Q,

1:4A 11 6 Elec!ro honics 22 [ d O-O.R. Areo Office CORRIDOR M.E. Mail L-Xerog o

-J.

Classroom g4,

-- g 7 a

g-m-

1 g

laboratory 14 3 :45 147 49 151 153155 e l61 163 165 157 169 i71 i

u (49Ccpooty)a l

fi-Dect. y f.tE Conf N _-

g~173 17 5 177

^

ll 1

O A

G (Ghar l Off I Room l \\s,[

i m

3 y

Graducre Office TAYLOR HALL - FIRST FLOOR o.,

e cm ~

g,,,

3 R

m 125 gi x g.

89 x 23:

m Film

'O R adioisotopes l

Laboratory Floor Walt D

A--

T, &

I o

M i

Doo r *5 O

Air Cosa.

O Taylo - Hass s

Room 131 g

Sto r<tge Wells heating Room irigo Re actor n

U e

c, E

C t

l 5

S C

r o

1 A

=

I Console JE a.

~

ra Pa ssage Deer *t E

'd2 f cc Reactor c -

33 Control Stora g e

?

,9 Room

~

a Door #+

Door #3 i

,J.

Y,

.e o

i w

m __

i I

c 33 I

t-I S-. Jice_ 3 ri. _ i '

l' i

1 I-IRc s tL 3

3

't 10 expected that the rate of growth and type of activities in the future will be about the same.

2.3.

Meteorology

]

Austin, capital of Texas, is located on the Colorado River where the stream crosses the Balcones Escarpment separating the Texas Hill Country from the Blackland Prtiries to the east.

Elevations within the City vary from 400 feet to 900 feet above sea level.

Native trees include cedar, oak, walnut, mesquite, and pecan.

The climate of Austin is humid subtropical with hot summers. Winters are mild, with below freezing temperatures occurring on an average of less than 25 I

~

days each year.

Rather strong northerly winds, accompanied by sharp drops in temperature,. occasionally occur during the winter months in connection with cold fronts, but cold spells are usually of short duration, rarely lasting more than two days.

Daytime temperatures in summer are hot, but summer nights are usually pleasant with average daily minima in the low seventies.

Precipitation is fairly evenly distributed throughout the year, with heaviest amounts occurring in late spring. A secondary rainfall peak occurs in September.

Precipitation from April through September usually results from thundershowers, with fairly large amounts falling within short periods of time.

While thunderstorms and heavy rains have occurred in all months of the year, most of the winter precipitation occurs as light rain.

Snow is insignificant as a source of moisture, and usually melts as rapidly as it falls. The City may experience several seasons in succession with no measurable snowfall.

Prevailing winds are southerly throughout the year. Northerly winds accompanying the colder airmasses in winter soon shift to southerly as these

~

airmasses move out over the Gulf of Mexico.

90013db9

~

86uuu02

11 The average length of the warm season (freeze-free period) is 270 days.

Based on data from 1943-1961, the average date of the last occurrence of 32 F in spring is March 3; the average'date of the first fall occurrence of 32'F is November 28.

Previous records show that 32*F or below has occurred as late as April 13 (1940), and as early as October 26 (1924).

~

Destructive winds and damaging hailstorms are infrequent.

On rare occasions, dissipat'ing tropical storms affect the City with strong winds and heavy rains.

Figures 7a, 7b, and 7c are a summary of meterological data for Austin for a typical. year, 1977.

Figure 8 shows monthly surface wind roses prepared from a summary of data for five recent years.

2.4.

Geology and Hydrology The northwestern half of Travis county is part of the physiographic province of Texas known as the Edwards Plateau.

In Travis County this is a highly dissected plateau with wooded hills rising in some places more than

~

500 feet above the drainageways.

In marked contrast, the southeastern half of hhe county is gently rolling prairie land which is part of the phy province k'nown as the Gulf Coastal Plain. These provinces are separated by the scarp of the Balcones fault zone, which rises 100 to 300 feet above the Coastal Plain.

The scarp, however, is not a vertical cliff; it is an indented

~

line of sloping hills leading up from the lower plain to the plateau summit.

Almost the entire county is drained by the Colorado River and its tributaries.

Lake Austin and Lake Travis, which are formed by the Tom Miller and Mansfield Dams, respectively, on the Colorado River, are part of the power, flood-control, water-conservation, and recreation project of the Lower colorado

~

Authority.

\\

'Y'l.(i{jf'

\\~

H Clf000 90013070

i <

12

          • 8 I4 g g.4

.>...... ****a.'.'

{,

it M

rstrrs tars : :

g#

.g O.y e.,".t**.'!*.*.....

'.!.'.' 11. *: " ",:

4 -

g::n :nsu :

~ ~*Q

"...........5~5 3-~.'saW6b~5EW.66 l

wp MD

'I f~f?-*"~" N ~ Y e

....u m

.cc ru'.88

-..is, i'

g _wfc "....

L.

c ga g M es

.==-

J e

.'cEv%r.s ;vc Tr.

g 3

j 3

=

w.as A..m

% A g un.ars-ee.si..- a.

.T.r.

a

.[

4.'tuaI8'a % ** M t.

g

.,4,. i,, a ya,. wg _,

. _.... e el g

.*(*6.

  • ap..

l one.i

)

)

8

-.m L,,c.,,.To-T

<<.r.rc.vrsu

.c

.h-

)

.,,,,,,,,76w sss a s1r.....

n..

was ai.ws 1

2".**."* * * " : ".

~

.R *T *~W*~~a= *

  • V*

g

- ggsca.-

n,v.

_._-...,o.. _.

.g,.,._

y j

mo g

,I m.~

., e6 s. m. ;y.--

w i -..n ". * * * ". *. *.?~'K. *T. '.f*.M.

ai.4 e

~

an

. us n-Tss.e. -

= +a.a.=8 F av a

  • ~a*
    • a=a g,.:, 3.;,,,

-~

- ~~

.n.n.m-n.. w.n.

a a

t:....

6 w.'.".,** " Z 4/J.~44 4ti/JJ J i

g )e

...ga..,... -,

l

,,,,,,,,, g s..ga; g;y;;;-r

).

3

,a.,y

  • " *. * *. ~.

w.

E

  • ~T*'

l

'.p- 'n' '

      • $1 0 L%t ** *$

'0"#

    • 888mp gy c

m

.. ~

l Y '" ~ ~d sju ~:g e rg G

w,,

g 9.u n MM..

G

  • 6 g

~~a 3

E a * '-'a

  • ' ** ~~****
  • a',,

.t '

o.

v, 6

....1.-.

G m

k

~

. r. a s..

.. r... <

n s

~......

m 6

1 5-O m.. ! v:.w. s

.s.e.r.. s

. ":.....t * :_*:* M. *. t_ _.

,6.,

g h

- -.3. c w, s, ar-- e-y

8 )-

a-- a s...

. 3 4.,,.

m

:C: n ittti 4

u.- w..e.+.66.

"O gj:

.3 gea

~

u F,

3 m....a ~s.a. m. -. -

3-m

  • " ~ " "

~ ~ ~ "

,,,^

c n.,io

~. -.

E tL tt 41

-*ja g

~

~

(

e..e O

w.

2M""

  • MY",

9 1 ""

~

  • ano an-W o

J c

m a

g -,,

g"g j

-..m r. o.-. v.., e.,.

C

=A s

f5.,

Ig _u

[

.~

C m

,.s w

8-

. _t _ H N_?* ::*

g

- -. -.- } -

,:Jadid 4444A*

I?S f9 a

      • ~

t I ':

O 3

  1. n..c..., e :.,,,,

E t

3
34 1
2. E

>S 2..

N

,^

_x. i g

_m

- - - ~

~ - g*

II.

.s

. 2.

f5 w.

ya.; E u.

O A.

..m,t ?.?.?*.0. a.? *.

.f

      • '**n AEAdEd A5.'055 0.~

t, L,"1 {

Q p

p

3*

g.,

=

aa o

. 4.t.y.

g g

6 8

9. " M 9 9 ""

O f

nti: :: n r st n W f

)8 O

A

~ ~ ~ ~ ~ ~ ' '

, "iI+#

    • '*4 6

g

^

~, 8.h na~,,,R 2 8.:. 2.:.

S.E.:.

3

,. 2.F 3-O s.

a

~~

... ;,- g.., e....

&'~

.8 l

g,.I t. i: h'

.e w

n

."__.4 4 4 ".4.A

"._"_A

'. 4 O

4 y.

F

.a A

Y-W

...eC*

3...

N-hg c

.n..............,.

s.

.t

?y

  • n.

.n t

g g

uge 3,g...Mrh{

- - ~ ~ ~~--

3 s

e um d4.*444 4J4444 4 43,,

g ggg;;; ;;;;;; ;

f. F, Nt g.d r

j

. w.,. ;. s c..

.:44442. 4:44:

i

""2 44444; 4444 4 f,

s:::1 :::::=

U*

sr s

'dadid Addaad a 38 1;E

  • i

. 28.......

5 J. -

=p

=

(P

%3

    • a g

3 3 y *> y

-w

-2.

e,,,,.,3 g ~*...

a ew B =..E:

f j

S

.a

.F. :#,.

a E. w

e.,

.,.a g-

3..,.

2

? [-

e.....

mA

~ 2 p

.=n

~.... -

g

.f l

[

1......~....

~.

.s r

.,m

s#2

. I p

"A

      • t**

.~.

t.H"

33. ".
  • tt Lt Ettt *.* ga

==an g1

,t g.

.iisc

.m.ad.as3 E.~..

8.. E -.

3. - g

}3e r a,

.a.-**

  • ....... ~....

===* a 8.

I..

u..

.E 6

4

~..........,

4.a=.

.c

.. ~*.r 62 g{}

e

~

r wo "aa a

....u..

1 I i"

~. '. ~ -W.. i. i.. a., Y.;.;;;.a..

s,*0 s.ad..ad.*a Aad..a d. a s

.I. E.,

Rg u

u a.:

e

.o.

.*. 2 wo y.

c. *-

.a e.

.... R amo

..n.

n o. g p.

n, 8

1

.u..

g

u..nn

n - 7a 0\\0U00V 900B07i s

i t

l

\\

l

6 13 Ocrage Temperature Heating Dsgres Days

.n s W i.Gi. iqs,T6qMifhu,n.l Jue,1 Ausls(Koci I No. I o0c IAnnu.i

s. en!avivlae:p.piloctINovlD.c I J nir nlMarl AprIM.,aun.;t0i.

i.o.

n 4

0..

a.. o.....i.... i.i.

n... !!...,....... n..n.........n.........,....o. i..... n..

n..,.. 0...,n......

0 n..

im.n 0

n.,

n......

in n

i.

e.n., m., oi o

...i i n, O'

0 im n 0

.i..-

n.,

. no i

ul

.i..

....n.. n.

im.0 0

O' n

... n..i....t...., n J.i n.. o..t

.. a,,...n.5 o.s....

n.,

...i i. n.i.i 01.

in, n.,...

n. 0 n 0

O n

in

.n. n.

n.. u...o... n......

i.. i.o o.

n..

n..,

no 0

0 n

n. u....

0 o.....,.n....,..

o..

n.

....n............n...

.n.i i o.

.n..o, n

.i o..

0 e

m

u..n i n e.o.,

0 a.,m.

o.i 'l a.

n...... n... n..

..$..5.n...n..io....n..

n...

.n...,

n.

.i.n.

.n n,. n.

r i.o...

0

....n...

...3...$ n.3 o.., o.3...

..3,.ai,J, i,d, e

0 O

n,0 i...

i n

...)...N.,

... ',..,s...........,........t i...

0 0

o....,,.......

n..........r...

i...

n i..

.n n.

n,

e. no

.. n.....

n..

n.

n.

n..

.,. i i......

O,

.. o.....

.n.1...'..,

n.,

i n.. o... n...n.,....o.i n. i...

n,

. n.

in n n 0

n..

o..

n.e...........,o.....n..

s....n..n.,. u....

n..

il 0

ini n.e...-

30, e no i.....

0 0

n.

o..

n.

o.. n..

n.t o

...,i en u.

- o.

o..

i....a 0

0 3

.a n.l I

. l e.!

.... ' 91..'....I

...,t l

]

l 2.

.0 i.,4 0

..l'; s.0, e,s t.S t

,.00 g, n, C

62

.49

, I se.........

l.,0.,,3 0

pi d,

.l.,

.9..

..d.

M..,

9....

e

..'i.,

1,9 i,

"3 8..,

5.,F n. T.

i'.,. 9 0...

1 i.ei, <..s..,. j n.L r

4

,10. 9 i,* I.,4 6

...I 1..

.9 9...

.i.i..

.v.. i

,3

.l.,

0 3

1..

Li e ss.

A

.I 0

O'

.! n.,.

n..

.. 1

...I i.9 l.i..

)

l...

. I,t n.

no

).i 0-3

..e..

S...

30...

i v.3.n 0

0 3..

3,9....3,.9,.

g...

9....

3 3..iq

,0..

4..

),

n.l 30 ' 33 0;

'i1 21 SI

$4..

1

.,S 0

Il

......}

.1

.4..

11.

3..

39 li.

8..

n.l i

.i..I... Il s. 9

)

i

..I 89 ;

3.,..I 3;

O 1...

i. f 1,W
3..S.,.,

.i

,0.

8 0

e I,

26.

.0

.9.9

.5.

9..

9...

4 3.,

0 Of din lj i..l 20 t'

.3 4.,..,

i >0 So.

5.

..S' 9..,

.3

..9

..0

,1..

)

n......,3..

.0..,

l.3 g., g

...,!.a...n., n.

e.,n.,....

'l i.l in n.l im.n n...o.. e n..o..... e...

n...n.....

o.

n......n,..

i im o.

..i,.i im.0 e

u.....:

3 n.

n.s a.,

u....l....! o..$. o., n...,) n) n..

o Cooling Degree Days

... n.. e' u..,s!....'

p..
o...I n..,,,

n u.a.

i

n... n.........o.in...

n..

o..

7w pani r blM ri AprIM.ylJun.!Juivl Aus:s ptioct lN0dD. iT0t.i c

n.

.n. i n..i.....u..i.,.

...,.n..

. n....

n n

.i..

ii.

...e 1.

. n.,.

0

..;.qs nn

.-. n,

n.

.o

...,i...

i.,

..i o.:

in.

no n.

s n.

n.

su os n

v..

n.. i... r.... n)... n.,i n. r,' n..,

i.n n,

.n

.n n.

...,, n, i

...i,,.

e i

n.....n.......

a.

n.

i...

...o....

n. c n..i....n..

,.i n....,.....o. o..,

n....

ai,no,

..i, n,

n.

ini

n..

n..

n o.

1

. i i.n.,.,,n.. u.

an io o.

im n.i

.n.

n.

.s n.,...., o. u.....,

i.

n.. n. i o..,.. i n.:

n.

un i

o.. n... o.,

.i n.

m

.n..n..

im 0

n n.,

n n.

n.......o..

n..

in.

.nt,

n, 3

mi

.., o. i i.n

n. no m

n..

on s

a su v, n.

n. m o. su n>

n an i

um n

... I l

n.,u

.nl.. -

o.., n., n.. n.. o.

n....o...

n.

n.:

n..

o.i o.:

n.

en o,il n,

.. I on e

,.i.

u.

n.

o..

im 0

n..

o.a n.....

n.

i

.o

n...... n..in.. n.

.n.. e... i n. n........,...o,.n..,

on n

, n.i n.,

c.

an 0

n n.

.n o..u... n.. o,..

0, n..

n..

n., n.,j o. i n.,n.i; n.

o..O on o.

n.

n.,

o..n..

n.., n.0, on n.g u..

on o.2 n...,n e i u.,d u.i

... n.e n ii.., u... n.. o..

n.

o......u.,

n..

i on a.

p.v u..' o e n.> n.a. o.s

.v n 1

n.,.n...... 1 o.i

)... i n...,n.. n..

.n. 0 n,j o.i n..o..o n

n.. o..i n., o.io.. n..

a..

n.

n....., n....w n.t n.

n..

o.. n..

0 o.

n..., n..

n.

u o..

m n.

. ~.

Precipitation Snowfall Yo.h.n[f eb [Mee j Apr l M.yhunel July [Aug}$ept[0ct l N0v l Dec lAnnu.i !

Se. son [Julyl Augypt[Oct lNovlDecl J.nIF.blMarl AprI M yiJune]T0t.1 S'. t.

3 11 ten 0..l 3..$

0.34 0 91 0...

1.,

3,.08 in0,1

6. 0' p

0.nl 0.nl 0.0 0,. 0 0,.0l e,..'l O.0

6. o'L c.0! e.oi l. 5,8 1

41

. 91 f.,A

..e 4 33.43 Sul n 0.08

.e 0. 08 f.9t 0.0 6. 01 e.0 0.A 0.06 1

1.0 3 91 9.00 6 91

1.. $

l..

4..$

g.3d 3.

1. 1 83 l' lf

.B. 01 493 9.81

..]

65 1.11 3.3

..i 30'

$.84 2.99 lI n 0.0 0.0 9.$ 6.ni0.el.e..

0,. 0 0,..

4. 0! e.,

0.0 00 0..

0..

00 0.el 0.0 8.,is.Os...i 8.S d.

1 19 0

]

im n 0.

0.0 0.

0..

..m...

.0 0.el 0..n.tj 4 a..a.

stu n 0.e 0.0 e.0 0.0 9.

0..:

0..

o.0 i

i.e.

3.

0...

7;.0....:

i., nn s.:

e n.i i.si e.0 0.0 6

e,el..e a..f

.0 2.14

.it 9.6 40 4n

0. 0. I 0...

.. n.

3 71

9. 9 9.

Gat 8 1

8..

..,1

3. 3 3...n s tu.,.

0.0 0.0 0.0 0.0

0. 9# 3. n.
0. 01 9.

. d. S.

2..

9.3 3 31 3 98 e,.0 e,. 0 g

0 49 9 3.u....). H.0a, 8'

$.91 8.9, 19 n,1 0.0

0. o1 0.0 6.n

.8

... 6 l..,.

.S.. t 4.. a

.0. 9 9 9,39 2.00 0 98 09 00 00 0.0 9.0 0.0' 1

8. 1 a o.n omn 0..

0..

0.0

.0 n.

..i

..$,.ig i.n 4,.i 3., 11

.ta

.*.11 l.34 4..

8. Id. 0d 4..i v.gi 3.,4

.,.3.

.It.0 0

9.,a 3.2
19..,
n. #

ese

.0 0.9 6.9 f

09 0..

03 0.0 0.0

.0 4.0 a ll te.46 lt 3 64 0.01 0.03 3, 91 1..

p..g

0..,1 3...

3,94 31,...

3.Je 3.A 0.21 1.3.

4.v.

g.8

3. 1 19 9.ta
8. E I.35 4..

3 0 let

l. 0
8. 9,4 7..,8 45

.J.P...$

,.9 39 5.,....,

.0).,.0%u.n 3.9 1.31 5.

6 0d 0.n

.3.,1 0 44 9 94

0.,1 n.9 4

8.

n.n 0

i 0,.91 36

.)

1994 0.91 2. 9,3

.S'. 5 8.1E 3.0.

. 19. 14 8.0 3.,. 9,.

.N 3 19

,0 1..I 9..t 0.0

8. #.

49S8

. 81

1. 4 8.fE

.S.08 3,)

3.

91

08. S 34 39...

0.46

...)

.o.1. 9..$.q

.s'.o.,

0 9).11 8.81 1.85

3. 4
e.. 9 9..e
0.. i a.

. 91 86 199 e.1 i.g 0.03

..n 0..g o.a a

.9 e.

4 14 0.se u..

on

..i

) 3.ve..,

on 1..i

0. 9.

S', n s.

0..,.

31 0.0 ts..l B.,

L,. a l Lee.

.I.. i

. 7.

9.98

.ld

8. 8 8 99 4.86 31.80
l. 0 3.79 3.10

..8 v.8, 895.,

.1 4.1.

9 l.

..H 9.

a..I

..o S.4 8 0..]

8.19 3.l.08 399 3.94

.n 7.9

.45 g..

. 1.fs f.B) 1310..)

0. J.4.0. n...c.0).3 30.a).a..... 4J

..). 9)..'). 9j 3.th 4999 c..I 4.33 e.3

. 01 89..

B.0. 0...

8. 4 18.8 4

)

3. 4

.I 49.

1.01 0.

B,B o.

9

... l i.,1

. 8,1 0 93, 5

88 8..-

sui 9.64 0..E te n.

.0

.2b s.08

0. 8

.l. 8 39

9. 8
4. l t
2. 5 0.8F 3.9 l' pl 3 10 9 58 G. 8 l..

A.50 3..d ',

4 l.o.

4.s.

d e

.la. e,t 19 9 04 9.0

1. 8 49 9,.9 a
0. 9 lu 3.Si 4..t 4.n 4..
1. d e.5 8. 0 91 4.3.

41

. 80 0 41 4.8 0.9

)

8..W 3

8 3

6 11

...I 38.19 8,93. 3q

,J,.81a

8. 2,4 0.1 f.) t,$.3 e..e

.,sd 19..,

.l.14 4 95 40

..a

9. $5 l..e, 4,11 5 b. 99

)..A 33.9 3.g g,p.v 1..

,.it

.g 0.91 9.,2 se.,s $.

3.llr 4.14 8..I

.li.in f 11 8..d.4 I.n.9.

9.94l..td

.8..e 3.0

$. 0.I a '0 14 ' S.48 1.

S,. n

.44 88.99 8.38 l a,18 B.,

3 9.8 0.4 n...

4.)#

14 02...

8.00 Het I

40.,8,t *,31 l

1 16 1.B3 S. 9 2.6 8.0 3 01

.3

3. 9.,

19,1 9.9..

0,. Ml 9..

3.9 4.n 4.986 8...

e. 9.E

1. E 9.34l 5 2 38 3 99 n. 0.3 19,7
3. 0 4..

4,. 3

..,3 2.0 2.9F 3.0,#

0 s..

14.111 8..$

,. 810.8j 0.v

.0...

6,8 9.., I 9. 8.%

0.95

)

5..e 3

3 Dd

3. 9
8. 9 4.9e 9.fe 3 04 1.9 0 21 90 19,.

S. 4 8.8l 6.94 3..31 9.

l.

1.

(

.nu v01 4 81 89.

1 1979 l.41

...J

..J. 9 t.,J

..! u.n.,

....i..:.,J.. n.

r,.

. n.. i.

..n

.9 0

..n

. 0.

.u

..n

..< uo on o.L O.G n.n 3..a 3..a 3.30 8.91

..it 8..I a.nt 8.21

3. 1 3.11 4 81
4..e 83.33
  1. ladle.te. e *t.tlun saw or relac.a tsei of instriswat.. See 5 st ren Lee. alan table.

.aeord e.n velve o e.c.e.1.re.wantfor pr.cipleetion, and 3%3 f or.for Lt e pa rtout beginning in a

thre Itt the f urlen. was late for seeperature.1 neist. n l.

> \\. t 'e

  • 1 Figure 7b g;g l

I

.i.

I 14 i

e.

STATION LOCATION mwe-. m seasarmaren - -

- e n=r-- '

~~ - is:aur.rsu:suus,:r w-arsenne w.ams mween --mestam - marurwammasemannym L

l'levasses shee, I

s "G enmed les '

w.ee.

mf.'

j e

.t

}

1~i l

gl

  • j i,

-~

t-e-o j

3 l

.[. i. 1 ; !,i,e t

oc t, e.

'm t i l

l l

c e

sm taistneveing Svilding 1906 6/08/23 30* 14' 9 7* 6& '

390 60 80 Ceeperellee stet ten.

Unleersity of leses anstneesing avlidsat 4/Ul/23 a/01/24 1/2 ail. W 10* 17' 9 f

  • 44 '

$60 6

3 Cooperative eletten.

mlvesente et 1 eses faalneerina Dwi8 dias 4/01/24 l0/IS/36 t /2 el. Inf 30* 87' 9 P* 44' 379 6

3 Cooperative stettemi.

thelversley of fenee taas 906. lit tlefield 10/16/76 l0/08/l4 1 1/2 et. B 30* It' 9F* 64' 495 664 133 135 128 lie Weather Dureev offlee.

Bids., 61sth 6 resigrees anon 400, tehral tenet 10/08/)6 2/12/42 t /4 si. Ind 30e 17' 9 f

  • 44'

$40 79 46 66 60 60 Weather tureau Cifice.

Detidin,, 290 W. Oth St.

e Amene #01 40) 2/12/4J 6/l6/42 1/4 sit. &L 30* 17' 97* 64' 49)

I fit 135 lil 128 128 toestlwr tureau Of flee.

littlefielil Sulldleig

& lath 6 tenstsee c

gy Adminionat i,n e sid'as 4/16/48 6/30/64 3

t. m w la' tra 62' 6is 32 6

5 3

3 Wlad lastreente 'l f at restletrel disport tsat st till/$l.

L o.6. tat ts eelan svildlas F/01/68 Present 0.7 el. SE 30' le' 4)* 42'

$97 20 65 bl 3

3 e6 e. careleesened t/1/61.

h00 tieni.e Ae.e4 b

  • Dinesseinwed 2/lles.

Insitelpel Aleppet a

Regw ste for edditional slimette informellen should be addsessed tot streeter, met tenel Cltestle fenter. Federal tallding, Aeheettle,11. C.

28808 seie e,iee. 20 eente m eeee. Ci.one end.eiie, e,d,,e een id 6.,ede,,,e ie L. Oe,o,ienni of c.a rce, swa. eseistaneee and. ort,.,endence r

ser.eed!*G thle pubilretlen sivseld be sent to bestenen Cliset6e senter, Federal Sulleles. Aeheellle, N. C.

26803. Atla s FutI l t a t ion e.

I rectify that this le en ef fletel publiestice of the met tenal Creente and Atoaspherte Aestaletrellen. and le eeepiled from reeerde an file et the L

Ilet t nel llastle Center, Asheville, Weeth Casaline 26801.

,e g Otretter. Met see en timeele Center Lf8CC191 IlOAA A&MfYlLLg. 900 Figure 7c 90013073 l

G

SURFACE WIND ROSES 15 N

A FIVE YEAR

SUMMARY

OF WIND VELOCITY AND DIRECTION BY MONTHS FDR AUSTIN. TEX AS JANUARY FEBRUARY MARCH APRIL

,s

' l3 15 11 l

y V

Y MAY JUNE JULY AUGUST 10 II 12 13

~

\\

v\\

~

V V

SEPTEMBER OCTOBER NOVEMBER DECEMBER

??

19 17 18 18 V

i FREQUENCY SCALE:

  • 8

,3 FROM CIRCUMFERENCE

', *, 8, *, 8,*

% OF CALMS ( O-3 MPH) l 4 - 12 M PH

<3 dVER 12 MPH l

NOTE: A line or arrow pointing south indicates a south wind, i.e., a wind blowing f rom the south to the north, etc.

1 b[lOQf

~

FIG. 8 90013074

a b ;

16 The rocks that crop out in Travis County are primarily of sedimentary

~

origin and of Mesozoic (Cretaceous) and Cenozoic age. They consist largely 4

of limestone, clay, and sand strata which dip southeastward toward the Gulf of Mexico at an angle slightly greater than the slope of the land surface. Thare-fore, in going from southeast to northwest the outcrops of progressively older formations are encountered, and the rocks lowest in the geologic column have the highest topographic exposure.

The Balcones fault zone, which extends from Williamson County to Uvalde County, extends the full. length of Travis County on a line passing through Manchaca, Austin, and McNeil. Here the orderly sequence of formations is replaced by an out-crop pattern controlled by the faults, most of which are normal faults with the down-thrown side toward the coast.

The Hosston, Sligo, and Travis Peak formations are believed to be the oldest and lowest formations beneath Travis County that offer possibilities

~

for ground-water development. These formatioas contain a number of sands, sandstones, and limestones known locally as the " Trinity sands," which yield water that has a considerable range in quality.

Yields of wells tapping the

" Trinity sands" have a large range. West of the fault zone the yields generally are small to moderate.

Yields are greater in the fault zone and to the east, the largest reported yield being 275 gpm.

East of the fault zone the water may flow naturally from wells at low elevations, the largest reported flow being 170 gpm. The water from the " Trinity sands" generally is of suitable quality for domestic and stock use, but in places it is highly mineralized.

~

The Glen Rose limestone generally yields only small quantities of water.

- In most. places the water becomes more highly mineralized with depth, calcium and magnesium sulfate accounting for most of the. increase.

~

9000075

=

J10t1009 I

I ree T

ws--r*

17

'The reactor site rests primarily upon limestone several hundred feet thick, as evidenced by test drillings and well logs.in the surrounding area.

These formations are essentially impervious, as shown by the high pressure of the water found below 300 to 1000 feet, some wells flowing to the surface without pumps. They slope -generally to the south, and little or no useful ground water is found above a depth of 300 feet. There is no well within a mile of the reactor. site, and only a few exist within Austin. A complete record (location, depth, use, ownership, etc.) of all wells in Travis County has been obtained from the Texas Board of Water Engineers so that in case of some unforeseen emergency, notification and water testing could be initiated immediately.

The Austin public water system, to which the University is connected, is supplied entirely with filtered river water and is distributed under pressure through a typical underground piping system.

The water is continuously tested and controlled under the jurisdiction of the City and State Health Departments. Occasional checks are made of its radioactivity, which runs about 6.3x10-9 pc/ml (gross S).

The Nuclear Reactor Laboratory has no sewer connections, either sanitary or storm.

Surface water run-off outside the Laboratory is directed into a University-owned storm sewer system. This portion of the system empties into Waller Creek about two blocks east of the Laboratory.

On a few occasions in the past small amounts of storm water have entered the Laboratory room.

For this and other reasons, the top of the reactor pit' was raised about ten inches above the room floor to preclude any possibility i

of contaminating the reactor pool water with storm water, and vice versa.

M

  • u m, 900!3076 HOL!000

18

' ~

2.5.

Seismoloqy According to " Earthquake History of the United States, Part I" (Coast

.andGeodeticSurvey),therehavebeennineearthquakesinTexas"fromthe

earliest times" to the close of 1956

l Felt

Distance, Distance from Date Location Intensity Miles Austin, Miles 1891 Rusk 7

200(est.)

200 1917 Panhandle 6

' Local 430 1925 N.W. Texas 5

250 430 1931 W. Texas 8

380 415

~

l 1932 Mexia 5-6 30 130

.1934 N. Texas 5

55 290 1936 N.W. Texas 5

140 450 1948 N.W. Texas 6

125 510 1951 N.W. Texas 6

125(est.)

510 The intensity is on the Modified Mercalli scale of 1931, on which intensity 7 indicates negligible damage in buildings of good design at the epicenter of the shock. The felt distance has been computed as the radius of a circle containing the recorded felt area, which is approximately that area included within isoseismal 3.

Intensity 3 is " vibration like passing of a truck."

Of the listed earthquakes, only the 1891 one might have been felt at Austin.

Its felt area was not recorded, and the estimated felt distance in this case was determined from typical areas of other intensity 7 earthquakes.

.It is highly probable that no detectable damage of any kind occurred in Austin due to this shock.

~

3\\0E1004 90013077 i

i

~

l_

19

"~

Study of a map of earthquakes in the above publication shows that Central Texas is one of the most earthquake-free areas in the entire country.

%e 90013078 h

9

.m we M

M h

ee e O

W n

4 n,,--

..o

20 i

3.

DESCRIPTION OF' BUILDING AND~ REACTOR 3.1.

Reactor Laboratory

~

i-The TRIGA-I reactor is located in Room 131 of Taylor Hall, the mechanical engineeringbuilding(seeFigures5and6). This room is of brick and reinforced-concrete construction, including the floor. The roof of the room is of steel girder and gypsum construction.

Partitions are of metal lath and cement plaster fireproof constructiloE.C knt/$$bE to the reactor laboratory is normally through a pair of sequential doors leading to the corridor. Access to the laboratory is restricted as described in section 4.4.1.

An area between the two access doors serves as a health-physics control point where personnel monitoring equipment is issued and information is obtained for the preparation of records in accordance with 10 CFR 20 and any other pertinent codes in effect. The outside double doors on the south wall of the laboratory will serve as emergency exit doors. Only with the reactor shut down and under the. direct supervision of authorized Laboratory personnel, are these doors used for any other purpose.

The Laboratory is air-conditioned and sealed off from the adjoining parts of Taylor Hall by tight fireproof walls and weatherstripped doors. Heat.

when needed, is supplied by steam-fed unit heaters in the Laboratory.

Figure 6 shows the arrangement of the major pieces of equipment in the Laboratory, and Figure 9 shows the arrangement of the pit relative to the existing floor, ground, and outside wall of the building. The fl,oor in most of the room is of 3" and 3.5" suspended concrete slab construction with strengthening concrete beams underneath. A small portion of the floor along the cast side of the room is a 6" concrete slab on grade. Around the periphery of this portion of Taylor Hall, including the south and west sides of the 90013079

21 Laboratory, is a service trench for various utility lines. This trench provides more space under the floor than would otherwise be available, as the floor slab is only about 3 or 4 feet above grade here and even less at

~

other locations.

The ceiling height in the main part of the Laboratory is about 16. h to the bottom of the steel girders and about 17 feet between the girders.

Over the east side of the room the ceiling is of saw-tooth shape and varies froiri about 12 to 20 feet in height. The ceiling (roof) is supported by stui girders and consists of 4.5-inch gypsum board and fill, one inch of rigid insulation, waterproofing, and built-up roofing.

The floor area of the room 2

3 is approximately 1700 ft and the room volume is about 24,000 ft,

The exterior (south and west) walls are solid brick 17" thick. The north wall and the present east wall are solid brick 13" thick.

The walls of the storage room and the adjacent office are of structural clay tile 6" thick.

The interior surfaces of all of these walls are completely covered with approximately 3/4" of gypsum plaster.

The south and west walls have projected steel windoivs with double-strength clear glass. They are sealed with plastic caulking compound and welded shut to prevent any future opening.

The doors to the room are sealed by means of commercial weatherstripping on the top and sides and on the bottom.

An analysis by General Atomic based on experimental data has shown that no special building requirements are necessary for housing a TRIGA reactor. A normal building, without any special provisions for air confinement,

\\

!BOL!00V 90013080 1

b

22' is satisfactory.. In case of a fuel'-element-cladding failure, the concentration of the~ airborne radioactive fission products at a short distance away from the Laboratory would be very low due to fresh-air dilution. The analysis indicates -

that the maxiuium integrated dose which a person might receive in the area of maximum concentration outside the building would be approximately 40 mr over a

' ~ '

1-hr period, based on infinite reactor operation at 250-kw power.

The only possible condition which might create airborne radioactive particulate matter would be a fuel-element-cladding failure.

Should an accident occur, it is possibic that small amounts of radioactive noble gases would be dispersed from the reactor pool into the air of the reactor building, and

~

these would decay into particulate matter.

According to the handbook Heating, Ventilating, and Air-Conditioning, the number of air changes in a building without a ventilation system varies from 0.5 to 2 air changes per hour under average conditions. Based on this, it can be assumed that most of the fission-product gases. leak out of the

~

reactor building within 1 hr. The fission-product gases are mainly xenon and krypton, with an average total activity in the building of 2.45 curies.

The average concentration of xenon an,d krypton in the reactor-building air would be 1.21 x 10-3 pc/cm.

If it is assumed that the fission-product gases 3

escape from the building at a lower rate than previously postulated, the integrated dose received by a person would be approximately the same as before, due to the longer decay period for the fission-product gases before leaving the building.

If the Laboratory ventilation system is operating during the release l.

of fission-product gases, the integrated dose received by a person near the building would be less than 16 mr for a 1-hr period, due to air dilution.

080U 00R 90013081 d*

,bq-g

ej j

t

=

r%:

GRhD LEVEL n

p-L.

~

t r.

T C+

l COUTSIDE SERVICE GROUND LEVEL

't WN L OF TRENCH BUILDING I

m I

l v.el l2e ns o"

_L

[

~

l I

O i

, g'.

t i

l l

?

l 7

,,1 o

,3, o o

i u

- _._-. __ _ _..~

9 u

O it i

scale I/4 = I O'e t'

y NUCLEAR REAC iOR P1T t

RM.131

" 9" 9 TAYLOR HALL

24 CONTROL ROD BRIVE SPICIMIN lifilNG ptlV! ANI III!CATOR

.4.

,,,y'*w*"* [*

Asstuttf S-ggstygtf t

m.~.

  • y p.,.

y.

(*..

0,iD r, M i h.

T h

y?

-t

,/, i s

CENTEW df.,,)",

l ',

I g..

',9 k

} k,

CHANNfi 4 -

,;/.- '

i ASSIW81Y jt f

I

.y l

J]

I I

l i}

N}l ;f

i 6 Jl r
l. ', 4"

,". : f 4I

!y, TUBE I.

. !i lj l,;

p-150iOPl#

flig

)

f(MOVAL i

'g

. - [ CENTRAL 1

\\

i xp[RiuggTAL 4

,J $ h a i

h TVII i

NiH A

,I<

4]j > ':

i

.; j p

$o s. { i..g'. j, 1i t.

\\

Y%

.$'l l h.

,.p.[

' t wp g,,, gat 7

'A -'

]

-.3 ass t

[

=

i p -

l

..j G

PWIUMATIC]t 'T

,-f TRANSTER

/..

"'I ' "

l 5

[

//

l n4 i

a I;.

.l.;l Q

j I

h.?

f '

"#q'}.jf J

notAar-d~TT-l.

!,1 Y k

Addf IPECINEN l

o i

aACK

[

J

",2.J;' l

- vr$ 4L! ' l<

Y L..

~~RIftEClot C[susta

.t. m.

,.jC&

~

.g*. ge j... er... j/, ',

s.

? - Atuviusu TANS

,./,t ggg}3Oh REACTOR AND PIT.

Figure 10

- h60k100?.

25 The TRIGA fuel elements especially developed for pulsing have safely received more than 1000 pulses of between 1.5% and 2.25% 6 k/k in the proto-type TRIGA Mark F reactor at San Diego. Assuming that a' fuel-element failure occurred once each year, the concentration of the fission-product gases leaving

~7 the building, averaged over a 1-yr. period, would be 1.38 x 10 pc/cm, and this concentration would be very much decreased by fresh-air dilution after traveling a short distance away from the b'lilding.

3.2.

Reactor Pit The reactor is located near the bottom of a pit below ground level (see Figures 9 and 10 ). The pit is lined with an aluminum tank 0.25 inches thick.

Outside the aluminum is poured concrete shielding varying in thickness from 48 inches in the vicinity of the core to 14 inches around the upper portion of the tank.

The assembly rests upon a 24-inch poured [ concrete slab as shown.

The reactor is located near one end of the elongated pit shown in Figure 9; the remainder of the pit is available for experimental purposes.

Figure 10 represents the standard TRIGA-I arrangement in a circular pit and closely approximates its appearance at one end of the proposed elongted tank.

The aluminum tank was completely shop-fabricated except for one Heli-arc field weld of an aluminum pressure relief line..All shop welds were 100%

X-rayed and tested for leaktightness by dye penetrant tests and helium-sniffing.

The one field weld was helium s'niffed with six times the normal helium pressure to compensate for the impossibility of X-raying at this point. The tank was coated on the exterior surface for corrosion protection and grouted in place on the previously poured bottom slab.

The radial concrete shielding was then poured around it.

Shielding above the core is provided by approximately 16 s.%0V 90013084

.c

.st si J

26 Three storage pits are located immediately adjacent to the reactor tank.

These pits are made of vertical' steel pipes 10 inches in diameter and 10 feet

~

~

long and lined with an organic coating. They may be filled with water and used for' temporary storage'of irradiated specimens or us'ed fuel elements prior to their ultimate dispo-a1.

3.3.

Reacto'r Core As shown in Figure 10, the core forms a right circular cylinder and consists of a lattice of cylindrical fuel-moderator elements, graphite dummy elements, and ~ control rods all immersed in water. The active portion of each fuel element (Figure 11) is 1.42 inches in diameter by 15 inches long and is a solid, homogeneous mixture of hydrided uranium-zirconium alloy 235 containing 8 wt-% uranium enriched to 20% in U The H-Zr atomic ratio is approximately 1.0.

Each element is jacketed with a.020 inch thick stainless steel can. Three inch sections of graphite are inserted in the can above and below the fuel to serve as top and bottom reflectors for the core.

Stainless steel end fixtures are attached to both ends of the can to support and position the elements in the core. The overall length of the element is 28.44 inches, i

The elements are spaced so that about 33% of the core volume is occupied by water.

This fuel-to-water ratio in the core was selected because calcula-tions show that it gives very nearly the minimum critical mass. A total of

' 69 fuel elements in the core are required for 250 kw operation.

Eighty-five fuel-element positions are available in the lattice; the unused positions are occupied by graphite dummy elements, i.e., elements in which the uranium-zirconium-hydride fuel is replaced by gragihite.

90013085 k

/

27

  • e+

t STAIN 1ESS STEEL TOP END-FIX TURE i

II h

a i i l l l I

/%

1476IN l I I

l.12 14 I

I

(

)

1470lN t

s-i i l g

\\

/

_A l-..I I

o i

j k- >-- --- L i, I

I

~ ~ ~ ~ ~~ ~ ~ ~

TOP END-VIEW or FU(L ELEMENT GRAPHITE I

l 3.5 IN.

{

Z3RCora>M HYtRDE p:'

l 0 WT- % URANIUM i.:

l l',

.; 15 IN.

t

.020 ftWALL b

i W

2300r4 l

t I

I i

4++

1 l

I A

i

[-__-

P 28.4 41R GRAPHITE 1

3.5 et I.

,I 7

lc

[ _,_ _,_--l 0 50 lN m

STARTLESS STEEL 00TTOM A END.FIXT URE i

o 2.62 IN.

\\Q~JO ) 14761N f

ii

'47o is C7 v

wiTOM END-VIEW OF FUEL ELEMENT

' :i, ;

FUEL MODERATOR ELEMENT p

s s.m, e ! 0 0 V, n9ure 11 90013086

q 28 l

. The elements'are supported and spaced by top and bottom grid plates of 6061. aluminum.

The bottom grid plate is 3/4 in thick, with holes drilled in it to receive the lower end-fixtures of the elements. These lower end-fixtures l'

have 1/4-in.-diameter projections on the bottom. A 5/8-in. shoulder is provided

}-

on the end-fixture, and the hole in the bottom grid plate is countersunk by a corresponding amount. The weight of the element rests on this shoulder, not on the bottom of the end-fixture, which is used only to position the element.

]

as it is being put into place.

]

The top grid plate is also 3/4 in. thick and has 1-1/2 in.-diam holes.

~

The top grid plate does not support any of the weight of the elements. ~ The holes serve only to determine the lateral position of the elements and to permititheir withdrawal from the core.

The core is cooled by natural circulation of water, which flows through the. core from bottom to top.

In addition to flowing in over the top of the l

bottom grid plate, space for the passage of cooling water through the bottom grid plate is provided by 36 special holes, and through the top grid plate by the gap between the triangular section of the fuel element and the round grid j

hole.

j 3.4.

Reactor Reflector The core is surrounded by a cylindrical reflector 12 in. thick,17 in.

ID, 42 in. 00, and 22 in, high. This reflector is completely encased in a welded aluminum can, and flooding of the graphite, in the event that the can should leak, will. decrease reactivity. The top and bottom reflectors are the 3-in. graphite sections encased in the fuel-element cans, so that the reflector in this region is approximately 67% graphite and 33% water, by volume.

The reficctor assembly is supported at the bottom by an aluminum structure, asinf;cgtgdyp910-90013087 1

29 3.5.

Irradiation facilities Special irradiation facilities are provided for the production o'

~

radioisotopes. These include a rotary specimen rack located '. the well in the reflector can, a pneumatic transfer tube, and a central thimble.

In addition, odd-shaped specimens may be irradiated in the water outside the

~

reflector (see Figure 10).

The rotary specimen rack consists basically of an aluminum ring which can be rotated around the core.

Forty aluminum cups, evenly spaced, are hung from the ring and serve as irradiation specimen holders. The ring can be ro-tated mantally from the top of the reactor pit, so that any one of these cups can be aligned with the single isotope-removal tube which runs up to the top of the reactor pit. This tube is used for removing and replacing irradiation specimens. An indexing cnd keying device is provided to ensure positive posi-tioning of the cups.

The rotary specimen rack is completely enclosed in a welded aluminum box. The aluminum ring is located at approximately the level of the top grid plate, with the specimen cups extending from the ring down to about 4 in, below the top of the active lattice.

In the radial direction, the centers of the cups are about 4 in, from the inner edge of the reflector assembly.

The box enclosing the rotary specimen rack has been designed to ensure that it will remain watertight.

Flooding of this box will decrease the reactivity of the reactor.

The pneumatic transfer tube is provided for the production of isotopes with short half lives.

It consists, in essence, of two tubes leading down through the water tank to any position in the core, where the tubes are joined.

The specimen is fed in and out through one of the tubes, and a blower connected e&UGOUV 90013088

30 to the tubes provides the pressure difference required to inject or eject the specimen. Specimens are inserted into and removed from the pneumatic system on the north wall of the radio-chem room.

A single thimble is provided to permit irradiations or experiments in any region of the core.

It consists of a vertical aluminum tube 1.33 in. ID

~

leading from the top of the reactor pit to any position in the reactor core and terminating below the bottom of the core. The bottom of the tube is capped, but holes drilled in the wall of the tube near the upper grid plate ensure that ti,e portion in the active lattice will always be filled with water during reactor operation. The portion of the tube above the core is normally filled with water but can be emptied to serve as a beam tube by app 1ving compressed air cr other gas to expel the water above the holes. A dry u be is also available for experimentation and can be placed in any region of the core.

3.6.

Control Rods and Drives Three control rods (safety-transient, shim, and regulating) operate in perforated aluminum guide tubes. The control rods for the shim and regulating rods are in sealed albs;inum tubes containing powdered boron carbide as a neutron poison. The safety-transient rod is similar except that a solid bar of borated graphite is used in place of the boron carbide.

The upper end of the control rod screws into the control rod drive assembly extension tube.

Each control rod is approximately 20 inches long. The outside diameter of the regulating rod is 7/8 inch, of the safety-transient

. rod 1 inch, and the shim rod is 1-1/4 inches in diameter. The vertical travel of the control rods is approximately 15 inches.

The safety-transient rod, located in the D-ring, is completely out of the core during normal steady-state operation, and its stroke is adjusted such that it will not be worth more than 1.5% 6 k/k during pulsing. The 880t!00" 90013089

0 31 1

R ACK-AND-PINION DRIVC ' ASSEMBLY CABLE GUIDE f

J MICROSWITCH E S gg' ROD ASSEMBLY n,$

.i'g

'h' DRIVE -

P SPRINGLOADED hd MOTO,R PULL ROD POTENTIOMETER

/'

,,#3 L A.,./

r,'r, g4 rc.,

ARMATURE 7

4 s(

./y pDRAW

  1. ,gN TUDE I

sTI kj.

TIP OF PUSH ROD e

l EL E CT R OM AGNE T L

i

}

.I

~*

FOOT

/

BARREL PISM

'}

a CONNECTING ROD

' A,

'0.

w i

l, BORON CARBIDE CONTROL ROD l

3-i)i 1

I

.I r

d

}

i i

l

,1 c', '

SHIM AND REGULATING CONTROL RODS AND DRIVES.

I90ll0dhbc %

90013090

32

(

~

total worth of this rod, however, will not exceed 1.7% 6 k/k. The shim rod is worth approximately 2.6% 6 k/k and is~ located in the C-ring. The regulating rod, located in the E-ring, is worth approximately 0.96 % 6 k/k. This makes the usable total rod worth approximately 5.06% 6 k/k. Total excess reactivity in the' core will be not greater than 2.25% 6 k/k. The maximum reactivity insertion rate associated with the withdrawal of any rod, except the safety-4 transient rod, is approximately 0.2% 6 k/k per second.

The control-rod-drive assemblies for the shim and regulating rods 2

(Figure 12) are mounted on the center-channel assembly and consist of a motor and reduction gear driving a rack and pinion. A helipot connected to the pinion generates the position indication. Each control rod has an extension tube which extends to a dashpot below the surface of the water. The dashpot i

and control-rod assembly are connected to the rack through an electro-magnet and. armature.

In the event of a power failure or scram, the control-rod magnet is de-energized and the rod falls into the core. The rod-drive motor is nonsynchronous, single-phase, and instantly reversible, and will insert or withdraw the control rod at a rate of approximately 11.4 in./ min.

Electrical dynamic and static braking on the motor are used for fast stops. Limit switches mounted on the drive assembly indicate the "up" and "down" positions of the magnet, the "down" position of the rod, and whether the magnet is in contact.with the rod. The complete drive assembly is enclosed in an aluminum can.

l The transient-rod drive is used to expel instantaneously (in less than 0.1 second) the transient rod from the core by means of pneumatic pressure.

The drive assembly is illustrated schematically and photographically in Figures 13 and 14. For pulsing operations, air pressure (75 psig) is applied to the MOU002 90013091

33 r--

cm

~~

SHOCK ABSORBER 2y VENT HOLES

-- L i

t FXTERNALL'Y THREADED CYLINDER PISTON SUPPORT rTT) rm

___ J l l I !I

~

~

'~

/

BEARINGS f

WORM

-=

~

=

BALL NUT WORM GEAR b

=

HOUSING a

d.r PISTON ROD VENT

=-

1

~

~ SUPPLY AIR SUPPLY l

fl0SE SOLEN 0lO VALVE

-b BOTTOM LIMIT ONNECTION TO

=

CONTROL ROD Ef0Ef000 90013092 l-

~

i -(; p, { i l ! }

i Schematic of Transient-Rod Drive Assembly

]

Figure 13

,.,, _, _ ~,,

m

---m=-

34 8

~

99 Cl v)

I

,,..t f.! k y b h

Di l'

,n,..

--..m

$1'" ~~. EmDL.

.~,j.3 l

  • 2qf(fk7 Y ',

c.i 5..:

I.

I

}f 1 I

in d.I LWi0

-.h

,p.:.s_m

.g..

lT t

}

l ';e; i

,n l

l --

~

90013093 (Q(d i O!IN PHOTOGRAPH OF TRANSIENT ROD DRIVE Figure 14 1

35 bottom tim of the piston to drive it upward until stopped by a hydraulic shock absorber. When air pressure is released by a fast-acting solenoid control valve, the piston will return by gravity action to its bottom limit to fully insert the transient rod in the core. The lower limit of rod travei is fixed t>y the housing and remains unchanged. The upper limit of rod travel is determined by the upper end of the cylinder which may be moved by turning the ball nut within the rod drive housing.

This ball nut engages the externcl threads on the cylinder. A revolution counter connected to the ball nut worm drive indicates the position of the cylinder.

Full-up and full-down indications for cylinder position are also provided.

3.7.

Instrumentation The reactor instrumentation for steady-state operation includes four neutron channels; water-radioactivity, water-temperature, and water-conductivity monitors; an area-radiation monitor; and a control console. The neutron channels are fed by four neutron-sensitive ion chambers that are sealed in aluminum cans and mounted around the reflector in the ion-chamber tube-mounting assembly. The type of chamber used and its location determine the range of the neutron flux measured. The reactor instrumentation described in this section is shown in block-diagram form in Fig.15.

1.

The Start-qn Channel consists of a fission counter, a pulse amplifier, and a log count-rate circuit. The channel gives useful power indication from j

source level (about 1 milliwatt) to greater than 1 watt. The log count rate is indicated on a meter at the upper left corner of the console panel (see Figure 16).

The circuit also includes a minimum source-strength interlock signal which will not allow the rods to be raised unless the source strength is adequate, j e.

Ud:

~

MOEi000 900l3094

(

[

l 8

/

(

{

l i

i l' '

I

.I I

T" N

FtS5 TON PRE-L C" N T-P N AMPURUt COUNTUt AMPLIFTER I COUNT RATE

  • SOURCE METER W

eNTEnt.DCK mv 1

E C LOG n ANO PERIOD COMPENSATED LOG a PER'OO l~T s.OG n AND pO CHANNEL CHAMeER AMPURER CIRCUti g

C TRANSIENT e

RECOROER I

PERtOO METER POWER-LEVEL COMPENSATED POWER-LEVEL i3 CHANNEL NO. I CHAmsER MONITOR v

3 g

.T r

LINEAR POWER MAGNET

  • TO ROO

{

A D NvT SCRAM O MAGNET j

~

i I

~

POWER-LEVEL UNCOMPENSATED S

POWER-LEVEL I

CHANNEL NO.2 CHAMBER M

YDEN O

MONITOR

[

3 lT I

PEAM POWER g

j AND

-- q NVT b80NtTOR T

g 7

i s

s (THERMOCOUPLES)

  • l L

SCRAM I

oJ l TEMP. PROBE l f (TEMPERATURE METER WATER AND FUEL ELEMENT)

[GElGER COUNTER l "NA f COUNT-RATE METER AN E

,pg 7 O

l COND* PROBE u WATER-CONDUNTY a

MONITOR

- STEADY-STATE OPERATION (5)

- TRANSIENT OPERATION (T) i U

C Block diagram of instrumentation

@un Figure 15

.wm e

1 e

t e

2.

37

~

2.

The Log n and Period Channel consists of a compensated ion chamber

~...

and a log n and period circuit., The compensated ion chamber feeds.a logging circuit which produces a voltage logarithmically dependent'on. the chamber current. This voltage.is displayed by the log n recording unit of the dual-pen recorder at the center of the console panel and gives log power from less than 1/10 watt to ful.1 power.

Reactor period information is also derived from the log n recording unit.and is displayed from -40 see to infinity to +7-sec on the period meter at the lower left side of the console panel. The operator may adjust this meter to.cause a scram for any positive reacter period less than a selected value; this period scram is adjustable between 7 and a sec.

3.

Power-level Channel No.1 consists of a compensated ion chamber and a recording micromicroammeter with a range switch to give accurate power information from source level to full power on the linear recording unit of the dual-pen recorder. This circuit also provides one of the power-level scrams.

P 4.

Power-level Channel No. 2 consists of an uncompensated ion chamber,

~

a power-level-monitor circuit, and a meter calibrated in percent of full power. The meter is located at the upper right side of the console panel.

This channel furnishes the second power-level scram, which can be adjusted by the operator from 0% to 110% of full power.

5.

The Dual-pen Recorder on.the control console displays both the linear

~

power level and the log n data.

It is composed of two complete and separate recorders, each with its own recording pen and ink color.

Pen cross-over is accomplished by one pen writing slightly forward of the other. The chart

\\

. recording. width is 11 in.

~

90013096 L

%%di<f 007 g_

p--

-c-.

38 5

The log n ccale is continuous from.3 to 3x10. The scale of the linear power level is controlled by the range switch on the operator's panel.

s.

6.

The Automatic Power-control System has been removed from the-system.

7.

The Water-radioactivity Monitor consists of a Geiger tube, count-rate circuit, and meter. The Geiger tube is located in the water-monitor vessel and is connected to a meter and an alarm in the console which will ring when the radioactivity exceeds a preset level.

8.

The Water-conductivity Monitor consists of two conductivity probes and a Wheatstone bridge circuit.

One probe is located upstream of the water demineralizer and the second probe is located downstream. Each conductivity probe consists of a platinum-electrode conductivity cell shielded with. glass.

Each cell is connected by two conductors, through a

~

selector switch, to a Wheatstone bridge circuit containing a one-stage amplifier, an electronic " tuning-eye," and a rectified power supply. This Wheatstone bridge, which reads water conductivity at either point, is located on the console. The selector switch permits the operator to connect the desired conductivity cell to the bridge circuit.

9.

The Water-temperature Monitor consists of a temperature probe in the water line leaving the demineralizer and a meter, on the console.

The temperature probe is a resistance thermometer of the tip-sensitive type.

~~

The reactor control console contains the control, indicat...;, and recording instrumentation required for operation of the reactor.

The instrumentation described above is located, as indicated, on either side of the dual-pen recorder and operator's panel.

On the operator's' panel are (1) rod-position indicators to show the

^-

positionoftheshimandregulatingrodstowithin0.2%;(2) control-rod W

~

90013097 n

39 1

buttons to control the position of each rod, and annunciator lights to indicate the up and down positions of each rod and rod-magnet control; (3) monitor alarm lights; and (4) additional pilot. lights to indicate power 1

on, cooling ' system on, and adequate source strength.

Other annunciator lights on the console indicate the source of a scram signal.

~

Scram is initiated by (1) excessive power level on either of the power-level channels, (2) too short a positive period, (3) ion-chamber power-supply failure, (4) operating-power failure, (5) manual scram or (6) excessive fuel temperature.

Following a scram or the dropping of any rod, and after the rod reaches the " full-in" positiun, the drive mechanism automatically follows the rod down to re-establish contact. A key-operated switch breaks the rod-magnet circuit so that the console may be operated without rod withdrawal if the switch is off.

A core loading which includes a special fuel element and a pneumatic rod are employed to permit routine pulsed operation of the reactor.

These special

~

elements, equipment, and instrumentation pennit the rapid insertion of 1.5% 6 k/k of excess reactivity, resulting in a pulsed peak power level of approximately 250,000 kw.

A special fuel element is equipped with three thermocouples eac4 for temperature measurement and scram following pulsed operation.

The additional equipment includes a high-speed, pneumatic

~

rod-drive mechanism that is substituted for one of the standard drives. This mechanism will withdraw the transient rod in about 0.1 sec. The transient rod will also serve as a -safety rod if in the full "out" position during steady-state operation.

In the steady state mode an interlock prevents application of air to the transient rod unless the shim and regulating rods are in the full "in" pos"tio[fa?EYUL ({l lO 90013098

k. '

w.,

,m

n...

( ~' - '

l '~

l~~

f ~~ ' '

[~

(~

- [ ~

[.~ ~

(~~

l -

{~~~

-l:-'

r-

[

f '--

J~

l-S DUAL PEN A.

RECORDER RCENT POWER METER y-

_.- LOG COUNT-RATE

72---.--

- + p.O -

' 7.'.7..-

-l TRICA 7; METER

==

, - ~

  • )-

s AUTDMATic POWER

. - - -- % v... q, CONTE SYSTEM s

e

. 7. e.

t:21 lF~

i -

c.=

.a-or

=

.g i.

WATER-PERWD METER

]

~

TEMPERATURE kES35_

,m

,m AND GAMMA W

r-ACTIVITY METER saanum g.,

,, H y,

g,.

~

m._

" m*.m*

.g WATER

w..a e-sagt t

CONDUCTWITY

~'

OPERATORS PANEL

,,,, ~,

~. -, -

1

._n I

e

.o 4o O

C

~

w. -~ a f... ; n e... - -

1

  1. m Control console (without pulsing instrumentation) o Figure 16 t

_. =

41 Transient operation is achieved by (1) bringing:the reactor to criticality with the transient. rod inserted and then to a reasonable power level in the steady-state operating mode; (2) turning the mode' switch (S), S ' 3, and S4 ganged;seeFig.16)topulsingmode;and(3) actuating 2-3 the pulse button.

Changing the switch from the steady-state to the transient.

modo removes the air interlock mentioned above, thus allowing pulsing to

~

take place.

Furthermore, it is not possible to move any rod except the trantient rod during transient-mode operation. This fact, coupled with the period scram during operation in the steady-state mode, will prevent pulsing while on a fast period.

Since normal instrumentation is disconnected during c

transient operation, the usual scrams for steady-state operation are not

^

used.

Scram is obtained during transient operation either by two fuel-temperature scram circuits or by excessive nv (neutron flux). The fuel-temperature scram will normally be set at 400 C, or less. Turning the mode switch climinates all neutron channels except one (the uncompensated chamber).

This chamber is connected to a peak-power and integrating circuit which will measure the peak power and the integrated nyt in the pulse, store the infor-mation in a memory, and then record this information sequentially on the linear recorder within a few seconds.

Fuel temperature is indicated accurately only on the two fuel temperature meters although the fuel temperature signals l

are also fed to the log n recorder.

A thennocouple selector switch is provided which will allow any thermocouple to-be niomentarily connected to.the meters during steady-state operation..' ?Thus, the various thermocouples can be checked against each other -

~

t at a fairly high power level. The 7-sec period scram during steady-state opera {on wgproduce a scram if the rod withdrawal were made fast enough E.

90013100 l

v.

_<.v..-

_.-,.,._-m,

42 e

2 '

to produce' an excess reactivity of $0.50 or great.or. A 2 Ci Americium-7 beryllium start-up source, with ' source strengtn of about 10 neutrons /sec, is located in a special source holder on the edge of the reactor core. The source can be raised from its normal position by means of either the fuel-element handling tool or a wire that is attached.to the top of the source 4

i element and tied to a cross member at the top of the reactor pit.

~

1 3.8.

Cooling and Water-treatment System The reactor is cooled by natural convection of the pool water. A 5-ton j-Freon vapor-compression chiller with an air-cooled condenser is used as the heat sink. Water from the reactor tank goes to a pump, a large filter tank

^

and then to the water monitor, where the gamma activity is measured.

It then goes back to the reactor tank and/or to the chiller unit.

From the chiller it goes through a filter, a demineralizer, a conductivity cell _ and then another s

conductivity cell, a temperature probe to the inlet of a rotameter, where

~

{

flow rate is measured. The water is then returned to the tank.

Figure 17 shows a schematic of the cooling and water-treatment system.

l 3.8.1.

Secondary Cooling System l

A second cooling system, as shown in Figure 18, has been added to facilitate f

removal of.the-extra heat generated by the increase in power to 250 kw. A detailed description of this system is found in the Manual for Operation of

~

the 250 kw Heat Exchanger.

3.9.

Core Physics The physics of the reactor has been studied in considerable detail on a critical-assembly mock-up as well as on the operating prototype.

In the succeeding sections, the more important features of the core physics are l~

discussed.

90013101 ouiti009

n i

1 i-p C14ttt ER y O\\U'D

, AT MA\\

I r*-- A T y3 gg 1

m

- w n,w N

  • '^

vo t.rtow T

P P

E ttTG R C E V T.

I v asvt y"

i pyn p l

G t4 u

c=

v mo s

.he A

n.a.

i m

~

Im>

qr

]

P I

i t

vot. rtou '

Flokt DR A M y e tyg

  • METER d

FITTER

(,,g eget s

3

[

\\ /

p{

VatVE' d

AN dh y

~

^

Eli

^

56 y

o o

5 b

\\

\\

bT

' " " " 7 CC"#

RETU R M /T a

~Q I

O O

O-57*V A ! zh T M 6 A' - RE acro R,

y en 5

-_=-

=

. Cool 7\\MT Loop g

_7 v

U N IV. c.f Texas sxm eeg N

^

L rni rrn AusT 3N 4

O W

t EAcloR poot s

i~

l i

f i

i

[

l i

VM Q

UNIVERSITY CHILL h

WATER sr 4

7 y

(

l

,'7

+

4'.

D/P

\\~

C.:

~

SECONDARY HEAT EXCHANGER

<v M

/\\

p y3 l

C b

l P

m r

DRAIN WATER m

V M

VN l

us SUPPLY THERMOCOUPLE ORIF CE GLAND SECONDARY

, y ym fT WATER Co SEAL 4 4 CONTROL I

I 7

V o

O h

-c e

SECONDARY / PRIMARY O

g V

COOLING SYSTEM o

U 7

I o

i REACTOR,,d ALAPJi CON 3 OLE l (AUDIBLE) l AT 4 PSID mmR WL d'

l n --

45

'"f

3. 9.1.z Critical Mass 1

The prototype TRIGA reactor attained criticality with 54 fuel elements, 235 or about 1.9 kg of U 3.9.2.

yoid Coefficient The void coefficient _ should be very similar to the values obtained on the critical-assembly, which were measured to be -0.15% 6 k per 1% water void at 23"C in the central region of'the core and +0.04% 6 k per 1% water void at 23 C at the" core-reflection interface, where there is a region of graphite-loaded dummy elements.

The core average value was approximately -0.10% 6 k'~

per 1% water void, which agrees with calculations.

~

Calculations indicate that the total reactivity value of the water in 9

the core is about 20%.

3.9.3.

Moderating Properties of Zirconium Hydride Experiments performed by General Atomic personnel at the Brookhaven National Laboratory have shown that zirconium hydride has very unusual

'~

moderating properties for slow neutrons. The results of these experiments can be explained by assuming that the hydrogen-atom lattice vibrations can be described by an Einstein model with a characteristic energy h v = 0.130 ev.

This description is consistent with the theory that the hydrogen atom occupies a lattice site at the center of a regular tetrahedron of zirconium atoms.

The basic consequences of this model, which ha',e been experimentally verified, are that 1.

Neutrons with energies of less than hv cannot lose energy in collisions with zirconium hydride.

2.

A slow neutron can gain an energy hv in a collision with

~

, zirconium hydride with a probability proportional to exp

}

(khddhwhichincreasesveryrapidlywithtemperature.

90013104

46 Since hv kT, it has been found that zirconium hydride is'not effective in thermalizing neutrons but that it can speed up neutrons already thermalized by water by transferring to them a quantum of energy hv.

3.9.4 Temperature Coefficient The fuel temperature coefficient of the TRIGA reactor has been ex-perimentally demonstrated to be--0.013% 6 k/k per 'C rise in average fuel tempera ture. The temperature coefficient associated with heating the water

~

and the fuel in the TRIGA reactor core is extremely small. The total reactivity contribution due to this latter coefficient over the range of 10" to 60"C is less ihn 0.08% 6 k/k. The operational characteristics of the reactor are therefore pri.marily determined by the extremely large prompt negative temperature coefficient. The experiments performed to determine this temperature coefficient demonstrate that it is a prompt coefficient negative temperature co3fficient. The experiments performed to determine this temperature coeff cient demonstrate that it is a prompt coefficient and that it is nearly constant over the power range from 0 to 1.4 Hw. This corresponds'to maxir.um fuel operating temperatures from am-bient to greater than 500 C.

At a power level of 250 kw, the maximum fuel temperature is approximately 140"C.

3.9.5, Reactivity perturbations Sources of reactivity associated with experimental facilities are:

1.

The rotary specimen rack fully " poisoned" is worth -0.15% 6 k/k.

2.

The pneumatic tube system, located in the sixth (or outside) ring of the core, when fully " poisoned" is worth -0.14%

6 k/k.

90013105

((

~'

47 3.

A fuel element replacing the central thimble adds about l.5% 6 k/k. A control rod in the same position is worth about -4% 6 k/k.

4.

The reactivity effect associated with replacing a void in the central thimble with water is approximately +0.04%

6 k/k.

5.

All other locations (excluding fuel positions) are outside the reflector and contribute only a trivial amount of reactivity.

6.

Extra elements added to the periphery of the core replacing graphite dummy elements would be worth about +0.4% 6 k/k l

each,

^

\\

l 90013106 l

W4 4

v 4

48 4.-

REACTOR'0PERATIONS The TRIGA-I reactor for The University of Texas in Austin is designed to operate continuously at a power. level of 250 kw. The maximum available

~

excess reactivity, for any temperature conditions which could conceivably be encountered, will be limited to 2.25% 6 k/k.

Experiments conducted with General Atomic's prototype TRIGA show that the reactor power level will be limited to safe values even if all of this available excess reactivity should be suddenly introduced into the reactor (see Section 5.1.4, " Reactor-PowerTransients").

4.1.

legal Requirements All operations shall be in strict accordance with The Code of Federal Regulations, Title 10- Energy and with any pertinent State, County and City codes then in effect. The reactor shall be operated only in the manner and for the purposeg aupo(ized by the Nuclear Regulatory Commission.

All reactor operations shall be performed by, or under the direction and in the presence of, a N.R.C.-licensed reactor operator. All use of " byproduct material" (10 CFR 30), " source material" (10 CFR 40), and ",pecial nuclear material" (10 CFR 70) shall be in accordance with licenses issued by the N.R.C.

4.2.

Initial Loading and Start-up 4.2.1.

Operational Limitations During the initial loading and start-up operation the reactor will be protected by at least two level trip channels at all times.

In addition, the period trip, which will be operable at all power levels, will be set to cause scram on a 7-sec period.

90013107 e

49

~

4.2.2.

Operational Procedures The following is a brief outline of the procedures usually followed in 7

perfonaing acceptance tests on the TRIGA reactor.

By following these proce-dures, all necessary instrument checks and nuclear calibrations were performed.

~

1.

Pre-Critical tests:

Functional tests of mechanical equipment.

a.

b.

Check-out of instrumentation and control system.

2.

Initial loading of fuel elements to criticality using inverse multiplication data.

~

3.

Tests to be performed upon reaching criticality:

Approximate calibration of control rods by rod drop method.

a.

b.

Adjustment of excess reactivity by addition of fuci elements and preliminary control rod calibration by the period method.

Final calibration of control rods by the period method and c.

detennination of final excess reactivity.

{

d.

Calibration of period meter.

4.

Tests to be performed at higher powers:

Check of instrument linearity by going to full power in a.

decade steps.

b.

Power calibration by the method of rate of rise of water temperature.

5.

Acceptance tests at rated power:

Demonstration of performance and reliability of reactor a.

system by operation at rated power.

b.

Radiation survey to demonstrate adequacy of reactor shielding.

00fEf000 90013108

50 c.

Demonstration of pulsing performance of reactor system.-

4.3.

Routine Operational procedures A routine checkout procedure has been established and is performed prior to start-up each day. The reactor operating procedures will prohibit reactor operation under the following conditions:

1.

If the fission counter or more than one of the other neutron-measuring channels is inoperative.

2.

If the count rate prior to start-up is below the specified

~

minimum.

3.

If any other condition exists which in the judgment of the Reactor Operator, Reactor Supervisor, or Laboratory Director might lead to a potential hazard.

Conditions which will cause the reactor to scram automatically are listed in Section 3.7.

The reactor will be shut down routinely by pressing the manual scram button on the operator's console and by driving all the control rods in.

A " Proposed Experiment" description must be prepared in fell detail by the experimenter and submitted to the Reactor Supervisor.

When and if

~

approved by the Reactor Supervisor, Laboratory Director, Chairman of the Reactor Comittee, and Chairman of the Radiation Safety Committee, it will become a "Special Experiment" and may be perfonned once. Then, if desired, the experiment and its results may be resubmitted for review, and if approved for the purpose by the same persons listed above, it will become a " Routine Experiment" and may be performed at any suitable time within the limitations of law, licenses, or other restrictions in force.

Significant alterations of the above procedure may be made only with the unanimous written approval of all of the above listed persons.

90013109 80 i,u 0th>

51 4.4.

Health-Safety Procedures 4.4.1.

Access to Laboratory Access to the Nuclear Reactor Laboratory will be restricted. Access will be governed by regulations approved by all of the following:

1.

Director, Nuclear Reactor Laboratory 2.

Chairman, Department of Mechanical Engineering 3.

Chairman, Reactor Committee 4.

Chairman, Radiation Safety Coninittee 5.

Radiation Safety Officer Modifications of the regulations may be made only with the approval of all of the above persons.

The Director of the Nuclear Reactor Laboratory will have ultimate control over access to the Laboratory.

He may at any time admit, refuse to admit, or expel any person within the scope of the above regulations.

Persons entering the Laboratory will be logged and monitored as described in Section 4.4.3.

4.4.2.

Materials Controls Storage.

The fuel elements will be installed in the reactor by licensed reactor laboratory personnel and, in normal operation, will remain in place in the reactor.

In the event of fuel-element failure, the element will be removed from t'e reactor by the use of a shielded cask and will be placed in one of the emergency storage pits temporarily.

The U.S.N.R.C. will then be contacted for permanent disposal of the element.

Accountability. The Director of the Nuclear Reactor Laboratory is responsible for fuel elements until they are returned to the NRC or i

its a ttorized representative.

  • Y I.I{00(

90013110

52

_ Radioactive Wastes.

Radioactive wastes will be disposed of in accordance with Title 10, Code of Federal Regulations, Part 20.

It is anticipated that spent-fuel-element disposal will not be required for a tamber of years.

4.4.3.

Health Physics E_quipment. The following items or their equivalents will be included in the health-physics equipment to be utilized in the Reactor Laboratory:

Victoreen Thyac III alpha-beta-ganna survey meter, Technical Associates alpha-beta-gama neutron survey meter, Nuclear Chicago Model 2673N fast-slow neutron survey meter,

^

Film badges, Landsverk~ thermal-neutron and gama-sensitive pocket dosimeters, Nuclear Measurements air sampler.

i Surveys. The reactor room will be constantly monitored by either a portable or installed G-M Area Radiation Monitor and a constant air monitor.

Reactor-pool water is monitored via the purification system and by quarterly samples taken by the Radiation Safety Officer.

Surface contamination wipe surveys will be performed quarterly by the Radiation Safety Office and at other times as deemed necessary by the Reactor Supervisor.

Unusual Events. Any perscn within the Reactor Laboratory is required to report unusual events to the Reactor Supervisor, who will investigate the event and recommend corrective measures to the Laboratory Director.

Personnel Safety Practices.

Entrance to the reactor laboratory will be controlled as described in. Section 4.4.1., " Access to Laboratory."

Laboratory personnel will be issued film badges, and occasional visitors will be required to wear pocket dosimeters. A log will be kept on all personnel entering, including film-badge number and ion-chamber readina.

900131Ii OlitiOOV

53-L Personnel in the laboratory will wear protective clothing as required and

~

will handle radioactive materials with gloves, with tongs, or with suitable remote-handling equipment.

l 4.5.

Organization-An organizational flow chart showing lines of responsibility for the Reactor facility is shown in Figure 19.

4.5.1.

Reactor Corvnittee Composition of this committee shall be a chairman plus at least three other members.

Appointment to or removal from this committee shall be by the Dean of Engineering on the basis of qualifications and interests, and the members are responsible to him. A maximum of one person may belong to both the Reactor Committee and the Isotopes Committee, provided that he not be 1

~~

chairman of both committees.

Functions of this committee are:

1.

To assist the Nuclear Reactor Laboratory Director in establishing operational procedures.

2.

To meet and receive a report at least quarterly from a designated committee member concerning his inspection of the Huclear Reactor Laboratory and the operation thereof.

3.

To meet as needed to approve or disapprove reactor ex eriments as submitted by the Nuclear Reactor

!Ii.f 00V.

La ora':ory Director.

4.

To meet as needed to approve or disapprove proposed changes in Nuclear Reactor Laboratory procedures and

.~

90013112 a----

---a

= - - - - -, _ _ _. _ -

,y

, = _

_.,-,p j

54 Dean of" Engineering 5

Chairman M. E. Department Director

- ~ ~ ~ ~

kgl((g[ ion fluelear Reactor Laboratory Reactor Commit [ce s%

/< Comittee

\\

/

/

%s

/

/

N* Reactor Supervisor

/

Reactor I

Instructorn Techniciana Experimenters i

LINE OF RESPONSIB!UTY CONSULTAT10N AND VETO POWER ORGANIZATIONAL CHART 90013113

=

a I

.)

~

55 proposed.significant' alterations to reactor instrumen-tation and proposed' changes in the N.R.C. utilization 1

facility license.

s 5.

To order a reactor experiment to;be stopped and/or l

the reactor not to be operated if in their opinion l

any significant hazard exists.

]

6.

To transmit to the Nuclear Reactor Laboratory I

Director or Supervisor whatever suggestions or f

conrnents' they consider desirable.

7.

The chairman shall cause written records to be kept of all committee actions.

8.

At his discretion the chairman may declare any number of committee members to constitute a quorum.

~

Modifications of the above may be made with the written approval of all of the following:

l l

Dean of Engineering Chairman, Mechanical Engineering Dept.

7 Chairman, Reactor Committee Director, Nuclear Reactor Laboratory 4.5.2.

Radiation Safety Committeg Composition of and appointment to or removal from this committee shall be determined by the Vice President and Provost, and the members are responsible to him.

i Functions of this committee are determined by the Vice President and Provost. The specific functions of this committee or their designated Radio-locical Protection Officer relative to the Nuclear Reactor Laboratory are:

2 i R.1000 90013114

i

'56 l'._-To furnish advice and assistance concerning radiological health upon. request from Nuclear. Reactor Laboratory personnel.

2.

To meet and' receive a report at least semi-annual.ly from L

the designated Radiological Protection Officer or committee member concerning his inspection of the radiological health t

aspects of the Nuclear Reactor Laboratory.

3.

To meet as needed to approve or disapprove reactor experiments from the radiological health standpoint as submitted by the L

Nuclear Reactor Laboratory Director.

t.

4.

To meet as needed to approve or disapprove from the radio-

~

logical health standpoint proposed changes in Nucleaf-Reactor Laboratory procedures as submitted by the Nuclear Reactor Laboratory Director.

5.

To order an experiment or other operation to be stopped if in their opinion a significant radiological health j

~

hazard exists.

6.

To transmit to the Nuclear Reactor Laboratory Director or Supervisor whatever suggestions or comments they consider desirable.

7.

The chairman shall cause records to be kept of all committee actions pertaining to the Nuclear Reactor Laboratory.

At his discretion, the chairman may declare any number of 8.

committee members to constitute a quorum in regard to their Nuclear Reactor Laboratory functions.

Modifications of the above which affect the Nuclear Reactor Laboratory may be made with the written approval of all of the following:

1 Vice President and Provost Chairman, Radiation Safety Committee g()

Director, Nuclear Reactor Laboratory 90013115 i

57 5.

POTENTIAL HAZARDS 4

~

5.1.

Hazards Associated with the Operation of the Reactor Certain potential hazards associated with the operation of the reactor system have been studied and have been found to cause no serious environmental hazord, nor any hazard to operating personnel.

However, in the handling of all radioactive material, because of its very nature, it is necessary to ob-serve accepted safety precautions.

In the normal use of TRIGA it will be necessary to handle irradiated samples, and standard health-physics procedures will be followed.

On the rare occasions when it is necessary to remove highly radioactive fuel elements from the water shield, special equipment and safety procedures will be utilized.

Specificolly, the following problems were investigated: activation of the soil surrounding the reactor pit; radioactive r.ontamination of the shielding water; and the production of radiorctive gases in the reactor. A description of the behovior of the reactor during a reactivity accident is presented. The possibility of loss of shielding water is discussed, as are the hazards of handling radioactive materials.

In order to evaluate the possible hazards associated with the operation of this reactor the following assumptions have been made:

1.

This reactor normally will have two standard modes of operation, as follows:

a.

Non-pulsed steady-state operation at power levels up to 250 kw.

b.

Pulsed operation produced by rapid transient-rod withdrawal, which results in insertion of a step increase of reactivity into the system.

The pulsing rod for the reactor system is designed to insert as a maximum 1.5% 6 k/t (2.00 dollar)

\\iil1000

_,e:ogo 900113116

A

-58 I

t above critical, which is.twice the amount required

~

to attain prompt criticality.

2.

The' reactor operations will be supervised by individuals who are qualified operators trained in the detection and evalua-tion of radiological hazards.

5.1.1.

_ Soil Activation The soil adjacent to the reactor pit will capture fast and thermal 2

neutrons which escape from the pit. The magnitude of the radioactivity induced has been approximated for typical soils in order to determine whether leaching

)

of activity in the soil by ground water might constitute a potential environ-1 mental hazard. The activities were below the permissible NRC tolerances for burial of radioactive materials. These calculations were based upon 250 kw a

steady-state operation with 48 inches of concrete shielding around the core a

~~

and 24 inches of concrete below it.

5.1.2.

Radioactive Contamination of Shielding Water Contaminant material susceptible to neutron irradiation in the shield water is' maintained at low levels by the demineralizing system. The hazards associated with a failure of the fuel-element cladding and consequent fission-

~

product contamination of the water have been calculated and studied experimen-tally as described in section 5.1.11.

The results show that in the improbable event of a cladding failure, the water activity may reach a maximum level of 3

0.8 pc/cm. The water may be decontaminated by using the demineralizer or by dilution. Manufacturing inspection and quality control assure that the possibility of a_ cladding failure is very small.

Three mechanisms (recoil, diffusion, and dissolution) govern the release of fission products from a fuel element. The nest important of these mechanisms

' ; 7.3 4

^

l 900J3117 M41002 n

e

-n-

59

^

is the fission-product recoil'from near the surface of the fuel. This mechanism,.

therefore, is considered in the calculation of the fission-product release after a fuel-element failure covered in section 5.1.11.

The dissolution rate f

of unciad fuel in water has also been studied experimentally at General Atomic and was found to be small.

5.1.3.

Production of Radioactive Gases by the Reactor Calculations and experiments nave shown that in regions of the reactor containing air, in which the neutron flux is assumed to be the same as that in 3

the rotary specimen rack, an equilibrium concentration of 7.5 pc/cm of 109-minute argon-41 is established after the reactor has operated at 250-kw for

~

several hours. Under these conditions, the equilibrium argon-41 content in the rotary specimen rack is calculated to be approximately 250 mil 11 curies (mc).

After the argon-41 is purged from this cavity, it takes several hours to re-establish an equilibrium concer.tration.

The maximum pennissible concentration (MPC) for radioactive argon is

-6 3

2 x 10 c/cm for a 40-br week.* This MPC would just be maintained in the 3

reactor building which has an air volume of 1000 m if approximately 8 mc of argon-41 were liberated in the room every 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> with no ventilation system in operation.

The transfer of argon from the rotary specimen rack to the reactor room

~

is inhibited by the long, slender access tube, and the tube cover plate.

The pneumatic transfer system has been modified to use carbon dioxide gas in a closed loop system. Calculations indicate saturated activities of 3

3 7.7 x 10-2 pc/cm of 7-second N-16 and 0.2 x 10-2 c/cm fo 29-second 0-19 exp sed to the neutron flux in the outer ring of may be produced in the C02 the core matrix.

The total activity that could be produced in the pneumatic tube during steady state operation is, therefore, approximately 12.6 pc.

~

90013118 kl le 10, Chapter 1, Part 20, Code of Federal Regulations w

e

-swmr a w,

s w--rw

60 Similar calculations show that the total activity induced in the C0 for a 7

$2,00 pulse is approximately 60 pc.

If this detivity were released instan-taneously into the reactor room the maximum resulting concentration would

~

be 6 x 10-8 pc/cm. This concentration is well below 1 x 10-0 pc/cm which 3

3 represents the MPC for CO in an unrestricted area.* Further, it should be 2

noted that these radioactive gases decay rapidly and that normally the C0 2

gas is contained in a closed loop system with a small leakage rate.

~

Significant quantities of 7-sec nitrogen-16 and small quantities of argon-41 (refer to section 5.1.13) are produced in the water of the reactor core. However, the transport time from the reactor core to the surface of the shielding water when the reactor is operating at 250-kw is sufficient to allow substantial decay of the nitrogen-16.

Experiments on the General Atomic TRIGA reactor show the following:

1.

Small quantities of nitrogen-16 and argon-41 are transferred from the reactor shielding water to the air in the reactor building.

2.

Although the nitrogen-16 and argon-41 activities in the shielding water contribute somewhat to the radiation dose measured at the top of the reactor during operation, the dosage is well within acceptable limits for personnel exposure.

5.1.4.

Reactor Power Transients Calculations show that the rapid insertion of $2.00 excess reactivity results in a pulse with a peak power of ~250 Mw, as shown in Fig. 1, and a reactor period of approximately 10 msec.

Experiments performed on the General Atomic prototype TRIGA reactor in San Diego confirm this analysis. Upon rapid

~

insertion of $2.00 excess reactivity, the reactor power level increases on b

  • it 1, Chapter 1, Part 20, Code of Federal Regulations 3jjg

6i 4

Within a few the preditted period and attains the predicted pedk level.

seconds after the initiation of the transient, the reactor power level returns to an equilibrium power level of about 200 kw. The rapid reduction in reactor

~

power level following peak power is brought about through the prompt. negative i

temperature coefficient, a characteristic of the reactor fuel-moderator elements.

This ' temperature coefficient has been measured to be an average of about $0.017 reactivity loss /C rise in fuel temperature.

The reactor loading will be a maximum of 2.25% 6 k/k ($3.00) excess reactivity above a cold, critical, and compact condition. A " compact condition" means that the core is loaded so that all of the innermost fuel positions

Thus, contain fuel, starting from the B-ring, which consists of six elements.

~

the maximum reactivity transient that could possibly occur would be that pro-duced by the rapid insertion of the entire available amount of excess reactivity.

~

During the metallurgical development of the pulsing TRIGA fuel, the prototype d--

TRIGA reactor at General Atomic was pulsed safely over 8000 times with reactivity insertionsupto2.25%6k/k($3.00). The resulting maximum e-c rsion attains a peak power of 1500 Mw; the reactor period is 4.0 msec; and the total energy The maximum measured fuel release during the burst is approximately 20 Mw-sec.

Curves of the transient power temperature during this pulse is less than 500 C.

level and of the fuel temperature during the $2.00 pulse are shown in Fig. 22.

On the basis of the operating experience with the TRIGA prototype, it is concluded that there is no hazard associated with the standard mode of pulsed operation, i.e., routine rapid insertion of up to and including 1.5%

6 k/k excess reactivity in this reactor; nor would there be any hazard asso-ciated with the sudden accidental insertion of the 2.25% 6 k/k total available excess reactivity in this reactor.

900l3120

.:i)()-

I5ilE1009-

-, ~.

i 62 i

5.1.5.

Loss of Shielding and Cooling Water Loss'of. water can occur by only_two means:

the tank may be pumped dry, or a tank failure may allow the water to drain.

The tank outlet water lines each have a 1/2-in.-diameter hole drilled a foot below the normal water level. The purpose of these holes is

'to break pump' suction or accidental siphoning if the tank water level drops

[

below this hole. Also the tank outlet pipe extends only about 3 ft below

~

norma 1' water level. Therefore, even if the water system were operated carelessly, for example, when the pump discharge line was disconnected for repairs, the tank could not be pumped dry accidentally. The tank can be pumped dry' only by deliberate action of the operating crew.

In the unlikely event that the tank must be drained for repairs, the fuel will be removed from the

~

reactor and stored in shielded casks.

The TRIGA Mark I concrete shield has been designed by a firm experienced in the design of earthquake-proof structures. There is no record of a facility of this type sustaining damage through an earthquake. The aluminum reactor tank and welded aluminum experimental facilities are designed and thoroughly tested to provide tightness against leakage.

~

Even though the possibility of the loss of shielding water is believed to be exceedingly remote, a calculation has been performed to evaluate the radiological hazards associated with this type of accident under the condition that the reactor has been operating for a long period of time at 250 kw prior to losing all of the shielding water. The radiation dose rates were determined for the two different locations given in Table 1.

The first location,18 ft.

-above the unshielded. reactor core at the top of the reactor tank, receives direct radiation.' The second location, at the top of the reactor shield, is skikidekf the direct radiation by the concrete reactor structure, but is subject to scattered' radiation.

The assumption is made that a thick concrete 90013121 J

i 63 ceiling 9 ft above the top of the reactor shield will maximize the reflected radiation dose. Normal roof structures would give considerably less back-

~.

scattering. Time is measured from the conclusion of 250 kw operation. Dose rates assume no water in the tank.

Table 1

~

RADIATION DOSE RATES AFTER 250-KW OPERATION AND LOSS OF ALL SHIELDING WATER

~

l Direct Scattered Time Radiation Radiation (r/hr)

(r/hr) 4 10 sec 2.7 x 10 15 3

1 day 1.4 x 10 0.8 2

~

1 week 9.3 x 10 0.5 2

1 month 4.5 x 10 0.2 The above data show that if an individual does not expose himself to the core directly, he could work for approximately 90 min at the top of the shield tank after 1 day without being exposed to radiation in excess of the normal quarterly occupational dose of approximately 1.25 rem allowed by 10 CFR 20 A 90-min, period would probably be sufficient time in which to view the interior of the shield tank with a mirror and to make emergency repairs.

Outside the building the radiation from the unshielded core would be coll. mated upward by the shield structure and, therefore, would not be a hazard to the public.

Calculations have been made by General Atomic (GA-7860) to determine the temp rat r

.r n a central (B-ring) fuel element if the cooling water 90013122 1

.I*

.~

- ~

J

~

64

.is lost instantaneously.

These calculations shown in section 5.1.12 were

~-

made in a very conservative manner in order to give an upper-limit estimate of the fuel-cladding temperature.

The calculations show that the maximum fuel-element temperature following an instantaneous and. complete loss of water would be less than 150 C.

On the basis of the considerations given above, the following conclusions wera -eached:

l.

The probability of the loss of all of the shielding water is extremely small.

2.

The concrete reactor shield provides adequate protection for nearby personnel in the event of the loss of all of the shielding water.

~

3.

The reactor shielding is sufficient to allow emergency repair of the leak approximately 1 day following shutdown, even after prolonged operation at maximum power.

4.

The gas pressure within the hottest fuel element

~

would not rupture the cladding; consequently, the loss of water would not damage the core.

5.1.6.

Production and Handling of Radioactive Material Because radiation from radioactive isotopes produced by this reactor can be intense, reactor operation must be supervised by persons who are trained in the detection and evaluation of radiological hazards. These hazards, however,

~

are the same.as those encountered with any reactor operating at comparable power levels.

j 90013123 SSitl002

~

-- m w-1

~

65 Calculations based on cobalt-60* activation indicate that at 250-kw the reactor can produce a radioisotope equilibrium concentration of approximately 2000 curies in the rotary specimen rack. A second source of radioactivity is the activity produced in the fuel-moderator elements. Calculations indicate that if the reactor is operated at 250 kw, the equilibrium activity associated 4

~

with one of these elements is approximatley 2 x 10 curies at the time of shutdown.

The maximum production of 2000 curies is distributed in 40 sample positions, each containing two sample containers; the maximum amount of activity that can

- be withdrawn at one time, therefore, is approximately 25 curies. Though intense,

~

such radiation sources are handled routinely by competent personnel.

The radioactivity hazard associated with fuel elements is of the same nature as that associated with isotope production. Because of the high radiation level associated with the reactor fuel-moderator elements during and after use, the elements will normally be kept under water for shielding purposes.

If an element is to be removed from the reactor tank, a conventional fuel-element transfer cask can be used to reduce the radiation level to within tolerable limits. The operation will be performed under strict supervision by safety cognizant staff members.

5.1.7.

Radiation Dose Rates Around Reactor Complete gamma dose measurements have been taken around typical TRIGA Mark I reactors during 250-kw steady-state operation'. Typical measurements e

No neutron leakage has been detected from operating are listed in Table 2.

TRIGA reactors except for a thermal neutron dose of 0.03 mrem /hr (15 neutrons /

2 cm -sec) measured above the rotary specimen rack drive shaft tube during 100-kw operation... ' > ;q(

90013124 dSIU 004

66 As indicated in Table 2, the measured radiation dose rates are low enough to allow operating personnel to perform experiments at the edge of.the reactor tank during full power operation.

Table 2 GA N DOSE RATES AROUND TRIGA MARK I REACTOR DURING 250-KW STEADY-STATE OPERATION Dose P. ate Location of Instrument Meas 2 -kw Steady-State Operation

)

1 ft above surface of reactor 15 to 30 tank water At handrail adjacent to reactor 3 to 5 tank 1

Maximum dose in the passage way beneath the floor of the

~50 b

reactor room,

a-Dose rates apply when the reactor cooling system is in operation.

These doses are given in milliroentgens (mr).

bThis dose rate is estimated from measurements taken during operation of the University of Texas TRIGA at 10 kw. A locked gate with in-structions to contact the Reactor Supervisor, Nuclear Reactor Laboratory, for admission controls access to this area, The maximum permissible dose in restricted areas established by 10 CFR 20, for persons whose previous radiation history is unknown, is 1.25 roentgens per quarter calendar year (approximately 100 mrem per week).

The International Commission on Radiation Protection (ICRP) recommends that the average external occupational exposure should not exceed 5 rem per year.

Es i t i 0u, t 90013125

  • een

67 5.1.8.

Reactivity Hazards Associated with Experimental Facilities Sources of reactivity associated with experimental facilities are:

~'

1.

The rotary specimen rack fully poisoned is worth

-0.15% 6 k/k.

2.

The pneumatic tube system, located in the F-ring of the core, fully poisoned is worth -0.14% 6.k/k.

3.

A fuel element replacing the central thimble adds

~

about 1.5% 6 k/k. A control rod in the same position is worth about -4% 6 k/k.

4.

All other locations (excluding fuel positions) are outside the reflector and contribute only a trivial amount of reactivity.

5.

Extra elements replacing graphite dummy elements at the periphery of the core would be worth about

+0.4% 6 k/k each.

5.1.9.

Fuel Element Failure A cladding failure, or even the failure of the cladding of several fuel

~

' elements, would not constitute an undue hazard to the operating crew, or the general public.

Should an accident occur, small amounts of radioactive noble gases could be dispersed from the reactor pool into the air the reactor building, and these would decay into particulate matter.

According to the handbook Heating, Ventilating, and Air-Conditioning Guide,* the number of air changes in the building without a ventilation system varies from 0.5 to 2 air changes per hour under average conditions. Based on this, it can be assumed that most of the fission-product gases leak out of

  • Heating, Ventilating, and Air-Conditioning Guide, American Society of Heating and Ventilating Engineers, New York, New York, 1953, p. 223.

l.

l 90013126

...J.iS p 002

.w l

68 the reoctor building within 1 hr. The fission-product gases are mainly xenon and krypton, with an average total activity in the building of 13.5 curies, as calculated and discussed in section 5.1.11.

The average concentration of xenon 3

and krypton in the reactor building air will be 1.35 x 10-2 c/cm.

If it is assumed that the fission-product gases leak out of one side of the building only, a person present for I hr near that side of the building could receive an integrated dose of 164 mr, resulting from the decay of the fission-product If the fission-product gases are assumed to escape from the building gases.

at a lower rate than previously postulated, the integrated dose received by a

~

person would be approximately the same as before, because of the longer decay period for the fission-product gases before leaving the building. This dose would be very much decreased by fresh-air dilution of the gases a short distance from the building. Assuming that a fuel-element failure occurred once each year, the concentration of the fission-product gases leaving the building,

-6 3

~

averaged over a 1-yr period, would be 1.54 x 10 pc/cm,

An example of the activity caused by a cladding failure is provided by an incident that occurred during operation of the prototype TRIGA reactor at San Diego. During transient tests perfonned to verify the operational safety of the TRIGA reactors, an early model non-pulsing-type fuel element suffered a cladding failure following the step insertion of 2.85% 6 k/k ($3.90). The following summarizes the results:

The activity in the pool water reached a maximum 1.

of 0.2 pc/ml.

It decayed very rapidly and was measured as 5 x 10-5 pc/ml, 24 hr after the clad-ding failure.

2.

The activity in the air of the reactor room reached

~

about 10 times the MPC for fission products and de-

cayed very rapidly. The maximum exposure to opera-dh[b$0t'iEgpersonnelwaslessthan1mr.

90013127

69 3.

The noble gases were not cellected on the filter

~~

samples used, but it may be inferred from the nature of the particulates observed that only the noble-gas fission products escape from the L.

TRIGA reactor pool in significant proportions when cladding fails.

~

The preceding discussion shows that no significant hazard to the public results from such an accident.

5.1.'10.

Adequate Steadr State Cooling The bulk water temperature will be maintained below 120'F at all times by administrative control. The pool water is continuously monitored while

^-

the reactor is in operation. An alarm will be set to annunciate and corrective action will be taken if the maximum bulk pool temperature reaches 120 F.

The rate of increase in water temperature with no cooling at 250 kw is calculated as 8.58*F/hr and a secondary cooling system heat exchanger has been installed which will reduce bulk pool temperature at the rate of 9'F/hr.

Thus, the reactor can be operated continuously at 250 kw with no increase in pool water temperature.

5.1.11.

Calculated Maximum Fission-Product Release After a Fuel Element Failure Calculations and a related experiment have been made to determine theoretically the maximum concentration of fission products that might be present in the reactor-room air following a fuel-element-cladding failure.

The calculations are based on the fact that as the reactor operates, fission products will be built up in the uranium-zirconium hydride fuel mixture

,]

until an equilibrium concentration is reached for each nuclide, dependent on 90013128

.x,o : s o

.. r..

fS R 100e

.c

70 (I) the' total energy release in the reactor, (2) the decay process for each nuclide, and (3) the yield of the species from fission. Of the various fission products produced in the fuel material, only certain nuclides will migrate into the gap between the fuel material and the fuel element cladding. These nuclides are thriodines, the xenons, the kryptons, and the decay products of all of these

~

elements.

Calculation of Gaseous Fission Products.

In the event of a rupture of the fuel element cladding, the fission products released to the water in the reactor tank will be limited to all or a portion of those fission products that have collected in the gap between the fuel material and the aluminum cladding.

~

A portion of these fission products will then go into the air above the water, this fraction depending on the solubility of the species in water.

The quantity of gaseous fission products produced in the fuel element was determined by Blomeke and Todd.* The amounts of krypton, xenon, and iodine produced in a typical element after infinite operation at 250 kw are given in

~

235 Table 3.

These data are based on a loading of 36.8 grams of U per element 235 where N is the initial number of U nuclei (9.4 x 10 2) and N is the 25 s

number 'of nuclei of the isotopes in the fuel element, and on an average flux 12 2

of 4 x 10 thermal neutrons /cm -sec.

Experimental Determination of Fission Products in Gap.

In order to determine the actual percentage of fission-product gases that escape from the fuel material and collect in the air gap between the cladding and the fuel material, the following experiment was conducted in the TRIGA reactor at General Atomic. A fuel element was fabricated with a sealed tube that vented the gap to a charcoal-filled cold trap a't the surface of the reactor tank.

  • J. O. Blomeke and Mary F. Todd, " Uranium-235 Fission-Product Production as a Function 9f,1 Thermal Neutron Flux, Irradiation Time, and Decay Time," Pt. I, Vol.1,i hk" itidg'elitional Laboratory, Report ORNL-2127,1957.

0 i

90013129 w

71 Table 3 GASEOUS FISSION PRODUCTS PRODUCED IN FUEL ELEMENT Decay-Isotopo N /N N

Constant, Activity, s

25 g

sec-1 curies

~

~

~

Kr 1.1 x 10 1.0 x 10 1.0 x 10

'28

~

Kr 7.8 x 10" 7.2 x 10 4.4 x 10 85

~

~

2.8 x 10 2.2 x 10 16 Kr 3.0 x 10

~

~

Kr 3.2 x 10 2. 9 x 10 1.5 x 10 119

~

~

208

~

Kr 1.2 x 10 1.1 x 10 7.0 x 10

~

~

Kr 2.0 x 10 1.8 x 10 3.6 x 10 179

~

~

Kr 5.8 x 10 5.3 x 10 2.1 x 10 303 13

~

~

Kr 2.7 x 10 2.5 x 10 2.3 x 10 155 O

~

I 1.6 x 10~

1.5 x 10 1.5 x 10 59.6

~

~

I 7.0 x 10 6.4 x 10 1.0 x 10 174 Xe 1.0 x 10~

7.2 x 10 6.7 x'10 1.7

~

~

~

I 1.3 x 10 1.2 x 10 8.0 x 10 259

~

~

I 1.6 x 10 1.5 x 10 9.3 x 10 371

~

~

Xe 1.0 x 10 9.2 x 10 3.5 x 10 8.7 Xe 1.0 x 10~

9.2 x 10 1.5 x 10 373

~

I 8.0 x 10~

7.4 x 10 2.2 x 10" 438 I

4.7 x 10" 4.3 x 10 2. 9 x 10 339

~

~

~

Xe 5.7 x 10 5.2 x 10 7.4 x 10 105

~

~

Xe 4.8 x 10 4.4 x 10 2.1 x 10 251

~

~

I 8.8 x 10 8.1 x 10 8.1 x 10 178

~

~

Xe 4.6 x 10 4.2 x 10 3.0 x 10 351 l38

-0

~

I 6.7 x 10 6.2 x 10 1.2 x 10 200

~4

~

Xe 1.9 x 10 1.8 x 10 6.8 x 10 327 3

~

~

~

I 1.6 x 10 1.5 x 10 2.6 x 10 104 Xe 6.5 x 10" 6.0 x 10 1.7 x 10 274

~

~

~

~

214 Xe 2.0 x 10 1.8 x 10 4.3 x 10 Total 5120 R. fl l 00V 90013130 m1in i

~

72 All of the fission-product gases that accumulated in the gap were collected in

~

the liquid-air-cooled charcoal trap by purging the system with helium, and the trap was analyzed. This measured amount of radioactive noble gases enabled the determination of the fraction of the fission products that diffused through the uranium-zirconium hydride material into the gap.

In the experiment, a total of 210 kw-hr of reactor operation took,' lace

~

12 in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. The test element was exposed to an average thermal flux of 2.1 x 10 2

l33 neutrons /cm -sec during this time, and the Xe that finds its way into the gap during the exposure of the element to a known amount of reactor flux, the per-133 centage of Xe and consequently of all other fission-product gases that collect in the gap can be determined.

133 During the experiment, Xe was produced in the fuel element from the

~

chain:

Te 133m 2.3d) 72%

2.4%

133 Cs Fission

> Sb I

(staMe)

(4.4m)

(20. 5h) y v

28%

97.6*

l33 y,133 Te (2m)

(5.27d) 133 12 The activity of Xe present in the element at the end of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 2.1 x 10 2

neutrons /cm -sec was determined from the work of Bolles and Ballou.* In this work

  • R. C. Bolles and N. E. Ballou, Calculated Activities and Abundances of

~

235 U

Fission Products," USNRDL-456, August 30, 1956.

90013131 g oos

73 133 235 the number of Xe nuclei present after the fission of 10,000 U nuclei is given as a function of time.

Integrating these data over 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> gives 133 0.49 x 10-3 Xe nuclei present per fission.

In the 1-hour experiment, the number of fissions is:

235 2

No. of 22 U atoms x 3.8 x 10-22 cm Fissions = 9.4 x 10 element 235 U

atom 12 neutrons 3

x 2.1 x 10 x 3.6 x 10 sec cm -sec I7

= 2.7 x 10

~

I7 I4 133 nuclei is 0.49 x 10-3 x 2.7 x 10

, or 1.3 x 10 Thus, the number of Xe 133 nuclei. This gives a total available.Me activity of L.

A = 1.52 x 10-6 14 3

x 1.3 x 10 pc = 5.4 x 10 c,

3.7 x 10

' ~

133 As was indicated previously, the amount of Xe that was collected in the gap at the end of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> was 78 microcuries. The percentage of the total inventory 133 of Xe that escaped to the gap between fuel and cladding, therefore, can be calculated as follows:

l33 Xe measured in gap,

78 pc

= 1.4%

l33 3

~

Xe total available 5.4 x 10 c

As shown in Table 3, at 250 kw the total quantity of all fission-product gases in a TRIGA reactor fuel element at equilibrium is 5,120 curies.

For the purposes of this calculation, it is assumed that the fractions of the iodine, krypton, and xenon isotopes produced that collect in the gap between fuel and cladding 133 are the same as that determined for Xe Thus, the total gaseous activity

~

in the gap is calculated to be 71.8 curies.

90013132

, m a m.

W

c 74 Therefore, the maximum amount of fission products that could _ be released in the event of a cladding failure is:

fodines 33.7 c Xenons 24.2 c Kryptons 13.9 c Total Fission Products 71.8 c 7

3 The volume of water in the TRIGA reactor tank is approximately 4.5 x 10 cm,

for purposes of this calculation, it is assumed that the total 71.8 curies of gaseous fission products in the gap escapes into the water. However, when these fission products (the iodines, kryptons, and xenons) are released from the fuel element into the water, the iodines will be dissolved in the water.

Since the kryptons and xenons are quite insoluble in water, it has been assumed for purposes of this analysi; that a major portion of these isotopes will escape into the reactor-room atmosphare. Based on the assumption that xenon and krypton follow Henry's law, it is estimated that 95% of the krypton will escape into the air and that all of the iodines will remain in the water. Therefore, the activity in the water will be:

0 A

pc, 33.7 + 0.05 x 24.2 + 0.02 x 13.9 x 10 pc water 7

3 cm 4.5 x 10 cm 6

3 35.2 x 10 c = 0.80 pc/cm

=

3 4.5 x 10 cm and the activity in the air will be 0.95A xenon (pc) + 0.98A krypton (pc)

A

=

3 air volume of air (cm )

6

, 0.95 x 24.2 + 0.98 x 13.9-x 10 c

9 1.0 x 10 cm bl3}N 6

Q %.5$iO 3 = 3.66 x 10 c/cm c

-2 3

9 4

1.0 x 10 cm

75 Since krypton and xenon are inert gases, the hazard presented by their being in air is f rom the dose a pt>rson in the room would receive from their decay.

To estimate this dose, it is assumed that each decay of a krypton or xenon Then the dose nucleus results in the emission of a 0.5-Mev gamma photon.

rate at the center of a hemispherical volume of E9,000 ft3 (equivalent radius

= 24.0 ft) is

-8 x 10-5 x 24.0 x 30.5)

D = Q.66 x 10-8)(3.7 x 1010)(1 - e 6

(2 x 8 x 10-5)(1.085 x 10 )

= 0.44b rad /hr = 445 mr/hr

-5

-I cm and the where the attenuation coefficient for air is taken as 8 x 10 6

flux-to-dose conversion factor is 1.085 x 10,

~

To estimate an integrated dose to a person remaining in the reactor room for I hour after a rupture, the xenon and krypton activities in the room were This average is 13.5 curies, or an average concentration averaged over 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

-2 3

of 1.35 x 10 c/cm,

if we assume that each disintegration is accompanied by a 0.5-Mev photon and that the room can be approximated by a hemisphere of equivalent volume, then by proportion, using the abova initial dose value, the average dose rate will be 3

D _. 1. 3L x 10~ 8 c/cm x 445 mr/hr = 164 mr/hr

~0 3

3.66 x 10 c/cm It can thus be observed that even on the basis of the conservative assumptions made herein, a person could remain in the reactor room for about one-half hour after a fuel-element-cladding failure without exceeding the permissible radiation Standard operating procedures for the facility will dose limit of 100 mr/ week.

require prompt evacuation of the reactor room by the operating personnel on indication of airborne radioactivity in the reactor roo 00I3134 dLiL!004

,,~

76 According to the Heating, Ventilating, and Air-Conditioning Guide,* the number of air changes in a building without a ventilation system varies from

~

0.5 to 2 air changes per hour under average conditions. Based on this, it can be assumed that most of the fissiun-product gases leak out of the reactor building within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. With an average total activity in the building of 13.5 curies, as calculated above, the average concentration of xenon and 3

krypton in the reactor-building air will be 1.35 x 10-2 pc/cm.

If it is assumed that the fission-product gases leak out of one side of the building only, a person present for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> near that side of the building would receive a maximum dose rate of 164 mr because of the decay of the fission-product gases. This dose is equal to that received by a person in the building for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

If it is assumed that the fission-product gases escaped from the building at a lower rate than previously postulated, the integrated dose received by a person would be approximately the same as before, owing to the longer decay period for the fission-product gases before leaving the building.

Assuming that a fuel-element failure occurred once each year, the concentration of the fission-product gases leaving the building, averaged over a 1-year period, would be

-2 3

1.35 x 10 ac/cm x 1 hr = 1.54 x 10-6 c/cm -yr, 2

A.

=

air 8765.8 1r/yr and this concentration would be very much decreased by fresh air dilution after traveling a short distance away from the building.

  • lleating, Ventilating, and Air-Conditioning Guide, American Society of

~

lleating and VentiTating Engineers, New York,1953, p. 223.

  1. U' U' uuV 90013135

t 77 5.1.12.

Calculations for ioss of Reactor Pool Water Although the total loss of reactor pool water is considered to be an extremely improbable event, calculations have been made to determine the maximum fuel temperature rise resulting from such a loss of coolant after operation for infinite time at 250 kw.

Results indicate that if the water loss in the core occurs immediately after the reactor has been shut down, the maximum temperature of the fuel, and consequently the aluminum cladding, is less than 150*C. This temperature is such that the pressure exerted by trapped air and fission product gases is less than 30 psi. This pressure produces a stress of about 660 psi, whereas, the yield stress for the aluminum cladding is 5000 psi at 150 C.

Therefore, the fission products will be re-tained in the fuel elements.

It should also be noted that although the only mechanism considered herein for heat removal after the water loss is through natural convection of air through the core, some heat will be removed by conduction to the grid plates, and some will be removed by radiation.

Use was made of a two-dimensional, transient heat transport computer code, entitled RAT, developed at General Atomic for calculating the maximum temperature in the core after a water loss.

It was assumed that at the time at which the water was lost, the tem-perature distribution in the fuel element considered in this calculation was equal to the temperature distribution in the hottest (B-ring) fuel element during steady-state operation of the reactor at 250 kw.

It was also assumed that the reactor had been operating for an infinite time at 250 kw with only 62 elements in the core. The rate of energy release in the B-ring element was determined from consideration of the energy deposition

'of fission product gammas and betas only.

The energy release from delayed

i.I(

90013136 J

78 neutrons is relatively small (about 1700 watt-sec total in the B-ring element) and has an average decay constant of about 0.08 sec 3

The after-shutdown power dens'ity (in Btu /hr-ft ) in the B-ring fuel element is given by:

0.78{(x-h) y=0.1p cos

-0.2

-0.2 t+t + 10

-0.87 t+t + 2x10

-0.5 (1) o o

~

where p

Peak-to-average power density in the core = 1.72

=

5 Operating reactor power = 8.525 x 10 Btu /hr(250kw)

P

=

3 V7= Volume of the fuel in the core = 0.81 ft L

Length of the fuel = 1.1666 ft

=

Distance measured from the bottom of fhe fuel element, ft

~~

x =

Time after the core is exposed to tb air, sec t

=

Time from shutdown to the time the core is exposed, sec.

t

=

g Equation (1) is a modification of the Untermeyer-Weill formula that matches the work of Stehn and Clancy*II) to about 5 x 10 sec after shutdown.

4

~

It is also conservatively assumed that all the energy produced by fission

' product decay in the element is deposited in the element.

While the decay gammas and betas are raising the fuel element temperature, the flow of air between the fuel elements will be removing heat, tending to lower the fuel temperature. The air velocity through the channel can be determined by setting the frictional pressure loss equal to the buoyancy.

Entrance and exit losses will be about 2-5% of the friction losses and have been ignored.

~'

Stehan, J. R., and E. F. Clancy, " Fission Product Radioactivity and Heat Generatiop(f[faper No.1071, Proceedings of the Second' United Nations' international Conference on the Peaceful Uses of Atomic Energy, United Nations,_ Geneva, Switzerland, September 1958.

g j3jg

,n

k 79 1

(

i 6P (buoyancy) = 6P (friction)

(2)

The term on the left is given by 6P (buoyancy) = (p0 ~P)

(3) l.

where L is the length of_the channel and p0 and p) are the~ entrance and exit l

air densities, respectively.

Since the frictional pressure drop calculations for laminar flow in non-circular channels are incorrect when expressed in termis of the hydraulic radius, the pressure drop for the TRIGA reactor must be predicted oy other means. The method selected was to convert the free-flow area into an annulus around the fuel element. With an annular space of inner diameter D) and outer diameter D, the frictional pressure drop becomes 2

32p 6P (Friction) =

2 -

(4) g D +D2, 02 - D)

~-

in(D/D) 2 j where Viscosity of air, lb/hr-ft

=

u Velocity of the air, ft/hr v =

Length of the fuel element, ft L

=

Dj= Fuel element diameter, ft D2= Dj + 2b, ft The term b in D should be effective separation distance between the B-ring 2

fuel element and those in the C-ring. The use of the minimum separat. ion i

distances as b would yield too large a pressure drop and is considered too restrictive. The use of the average separation distance, based on the free flow between the B-ring element and the C-ring, would yield too low a pressure drop since the pressure drop is not a linear function of the separation dis-

  • Ib Ib tance. As an approximation, b is taken as the mean of the two values, that is N.IEI009 90013138 i

6

80 b=f(0.01130+.04930)=0.0303ft (5)

~

For the channel between the B-ring and the C-ring, the equation for

~~

the pressure balance (2) becomes

-5

~ P ) = 6.88 x 10 6 v, (6)

(p0 1

where p is the average viscosity of the air (1b/hr-ft) in the channel and is

~

a function of the entrance and exit temperatures, v is the average air velocity (ft/hr) in the channel, and the entrance and exit densities are p0 and p) 3 (1b/ft ),

The mass ficw rate of air in the channel is w=vpA' (7)

~

c where p is the average density of air in the channel, and A is the flow c

area associated with the channel.

Combiningequations(6)and(7),one obtains the nass flow rate w=405.(p0-P)p/E (8) 1 Assumingthattheaveragepropertiesinequation(8)aretheaverageofthe

~

propertiesattheentranceandexit, equation (8)becomes 2

(p -p) w = 405.

(9)

(90*P) 1 Over the range of temperatures of interest the properties of air have been approximated by linear equations. Thus, 3

p = 2.5 x 10-2 lb/ft and (10) p = (0.01135 + 0.6017 x 10~4 ) lb/hr-ft T

where T is the temperature in

  • Rankine.

90013139 Bt!EI002

81 Using these expressions in equation (9) one obtains 3.24 x 105 (T2 2

-T) w=

lb/hr (T Tf)}0.01135+0.30085x10-4(T)+T)

(11) 2

~ ~ ~

O The determination of the amount of heat removed by this air flowing past the element rests on the evaluation of a heat transfer coefficient.

For a free-

~

standing cylinder cooled by natural circulation, the heat transfer coefficient is given, conservatively, by k

0.25 f.

h = 0.531 p

GrPr, (12) where k is the thermal conductivity of the air film at temperature T g

f (8tu/.5-f t-F), Gr is the Grashof number, and Pr is the Prandtl number.

Because the fuel element is surrounded by adjacent elements, the flow will probably not be laminar, even at low Reynolds numbers, and the heat transfer correlation should be better than that assumed, perhaps by as much as a factor of 2.

Again, over the temperature range of interest, one can write for the thermal conductivity and specific heat of the air (0.009 + 0.26 x 10-4 ) Btu /hr-ft-F k

T

=

a and' (13)

~

C

= 0.240 Btu /lb-F pa with temperature, T, in *R.

Using these values and those in equation (10) in equation (12) one obtains 3

-4 (T,+ T,)

h = 50.16 0.0009 + 0.13 x 10 1.25 x 10-2 (T +T) 0.5(T,+T)

(I4) g a

a s

+T

-I (T -T) 0.25

[0.01135 + 0.30085 x 10-4 (T g

y a

i M. i OOV u m.

900l3140 g.

82 where T,_is the wall temperature, T is the bulk air temperature, and T is a

f the average of the two, all in R.

For the purpose of this analysis the heat transfer along the graphite end reflectors was neglected, and the fuel element was considered to be a 1.1666-f t-long, 0.1225-ft-diameter cylinder of U-ZrH with specific heat 1.0 and thermal conductivity given by:

3 C

= (26.3 + 0.0245 T) Btu /ft,op pf and-(15) g = (10.7 - 6.42 x 10~4 T) Btu /hr-ft *F k

where T is the local temperature in *R.

The temperature drop in the clad was

'~

ignored because, at the time of peak temperature, it has been calculated to be insignificant (1-5 C).

For the computer program, the fuel element was divided into five radial and five axial regions, and the temperature in each region was computed as a function of time after complete water loss.

In Figure 20 the maximum fuel temperature calculated is plotted as a function of time after the loss of cooling water. The loss of water in the core was assumed to take place immediately at shutdown, and the maximum initial fuel temperature is 113 C.

To determine the pressure exerted on the cladding by released hydrogen, fission products, and air trapped in the fuel can, the conservative assumption will be made that the entire system is at the peak fuel temperature, i.e., about 150 C.

The total number of fission product nuclei released to the gap between the fuel and clad was determined from Elomeke and Todd,(3) and the results of the experiment described in section 5.1.11.

The total quantity of Br, I, Kr.

)

~

and Xe' released to the gap in the B-ring fuel element af ter infinite operation at 250 kw will be 90013141 90t.t00V

~

. ~. --

l.

l' d

}

4 83

. mes 9 s

t;

.o t.

, ua '

oo*

,,i

.,s

~"T u N p'ij.i+ i *r IT;1

-r r v pri c4- -d * '.*

9-

< a lo[#..t I M*1' ! ^ L; T~ f- *

  • u+-.:14.i O

k

.t-g p

t

  • i ) I - "1. 4'. -
t i-'

,% i r i. 't a h-

=

9

.4.q. r j--

j 4..: w.i l.

$..[ ]g.e' +

- 0: :

f, M.4.a.r -

i.a 2.Tri.- [ Al'..:.7;. j - ~:* *'".[

si.

+

4, p q.j...-[.g +

? -**-M

  • ! 'J..

- r- [ "..

-; c. A M t.:..J

  • t T.gr,u i -t. ;

t- :- t

~ *' *% :}?-

L t.f.:

.L' : y4 { L.

.1 th.-[..g}

..i

'Y y

g *

.g.

.J

g ta.f : h:.:

-- * -. ?.1. l' J L !;.' =..=.r t g i

?*...-].:J

. ".t" ?-

. - :.J ? '- * * *

.:?..

  • .!.1(

1 *m t.. :...

3..

M.1

4

". 7...**r*:

..t:-t s 3..t

..................~r-.,....1..1....

mi *!

4

...... N........*****3 P T.. **." ~1 'T......-'T..:".4?.-.

.,,.....L........._I......T...........

....rr...t.r...........

+

t 6.-

....p.....e-........,n..,...

. g j (..., }. *b; * -h s- -[?L}. st Wia A

  • I.w:.a L*.*';, j ?>,

0,.

.e, 1-L 0, 1:

.p.{' l.t-L5-

.c.

2 HL ^t f.

5 s.,

n=

v Tzd.

.t-t.n s.

,'.g,y9..f s.

+

p. y4:.f. r }nn ~=. p m.:.:.7 L._w,.g e

. g 6'

6

.22.7 r. @ w J.:,

. j.n 6 7

-Jf

. I *. 5.l.w....

.. 4. j..,{. 4. l.s 4

i n

m.*

- 4 3.:

p

. :.- 3

t. : ma.:

re.:: :.r:1

,b, !.. I.- t,,2 :c: r. ub.. :

os..:.

s ::.n- :: : ? =:.. ~~=y: t

::.=:t. ::.:a c.r. ;n.:--::a.-.g

. 4 ' r..t. as/ j

.u t:.c s-- :n.re.

=::.:.-ac p :rz7re..au. a.

=: r.

t: s.:==

a

,. r

. 3.... :. c.:s 4: :.3.1.::3.. F.

r- - - -

r '3.::: r.an...:

. :=

a i

t

.. -: t= =m :a U

.-...'%......l.-..1.~_...J._:*........ T.d'*

... d.

.lA

)

-~ : a.. = =:-: a. = -:.

L-* *.. J..~..._...._......

.. ~.

-.4.

.f..,....

..t*:

P"I

.......1......

..!.3.. F +'..... r..

1

.4-1....~...-..

4,

........c,....

...-4 t.

_1.................

.... J'

.. 71 L,....e,...............g..

e y

..w...

.~.,. - -

6.3..

..... ~.

~

O y

P--*

U

. *.t 4.,

2

-t

~~~

4..

%.].-*-'*.,____.. '.

.........y

..,.I,....

.,..~. _

,. +.

..L-_ i r.

. ~. r. 4.m

.i."#.-...+j.,...

....m. _.

- - 4 u,O

.1.

.M._.

e.

- u L I

.J. 4,

L.-

a

. m..t..

a e.

s L,.~:.s

.e

,~.-.

..-. i

. i

.- i i i O

L.,4

~

t,.,

I

!. o a,

t L

.. i

.a L,..L,

.I~T

... i e.. m i.

. i

a. :a.f.a,.; :

' I i

.g

'l.

_a' i

O W

t1 -

..1,..~,,..+.-..,

t.-*u-'f ; '".

- ~'

., 4 y-i J

U U u

s

~

. g '.t~.

, U-i.

" * =,-T y

' g

.. q. ~J i., a _

a:.wir 2.

. i., j '.. -- 7.. : 3 --

i a p'=7 4 4,'s..-[ Y y.

M i-M i.a :.. P-I a.t. 4 gy

'r j,

m. s : (< g., p 3- ?.4 r.T b

q }q j _

8

.gi:

,. t " 4

- = n.:.u.;: : p 3 s.; t w'+.:...: :p-r. ::.- ;.1

;. r 9.

> - *--t--

- -e*.r

  • et O

,.p

~

r,.--::.ptmt-; 7.wr.q-:

-?

t-I y g

, L.i "

-l..,..Ie. t.a.q.

. :.:.., :_.. t. :: : -

p z:

.a : ^

A:.....,

.;1.r

... e : c: :. a..

.r...... c. n:--et,-:,.: a p. :. :_:.t. :

.:.r..n z. : ::p :. rr. :.:

,t -

7 i.2 ::

r. : e -. -.:.m : -w r.2 -:.:. m t.:.y;

-.. r.

s. m: 1.:

O @

.T**.*.**:.T..J:*.......r...............$

. ? t* ?* * *"r *1,-......t***7...m.....

6

....'--T* ** *l %.

7 g -. "1... I.n..a.

7 l'h,_...r..I u "D n,-... --

U C

....... 3.-.

-l.....l..1............._......,.,. h q.

n r iO l t r

.w.

l. ' i. k.q ~g

.1. y

h.f 4. r-J,v..J.

M i m.

e,....

L s. or-

..g

&,..l~7 a

l.

T L:nMy t.f.} A e

4 w

1 r P g }.E.

.n...-,. a..!. p g

.n..,L..v. s ;' :

..,_-r

. t.

1.# 1

. v s

.*.n.

1 O O j

5 t

r 4

-A J.=..r.:-. :u p

4

.j3 a

t m-py q:... :.::.g. t,,..

n:.-t.. s.n :.t.-

..L t

m,. t, c.r,: c i. u..:;.t.w:

r--

.r

-r :

e.: I-:

y t-sL

.u e

a

:r m.-=:a. =3 ::, r-:,. :: :e: :: ~,1 w

O c.,

3.. 5 a :.

- 3 J... :..::::.u t :

. ~. l..;... r..::..

c :

1

.i : r.

a. m.: -

... z _.._....... _....._ t - _.:--+. s _ :.::.:.:.:-3.r -:

r.._.

l. t.

t-s.. :

-: -u: -

. t u-v t.-u: :

t..: u.....

..........._...:,.__._..~............

m O

.i

............s_....

5 M,3

.....t.1...,........

..t r...

... r....m..

.-.n......r._....._....__..

..._2e....

.!..._.......... ~.

........... ~..

. 1 w

a.-

_........_....L..... _..4

....L.

_E u

d

?"~

l.,...

i

... t w

n.

o_...

. g 4 q...

...7_...p.. ~6.~.s - ' -

t

. p4 _ '.

Q@

.m_

00

.4

~..

...>.4.,.b...~

94 6,

a L-4.4

.e..

.. 4.4 i

f I

  • 4N

.. L.-

a 4,

g

_e

}.

b.dd. h.4_

l 1-

, 84 M.

L:

O*

I'

.. f

{. F, g. 8

}..

4.a'. g.q L

r 4 4 -b. b..

- *-

  • i P--

i a..

-m ----

. g l.l.

1 M

u

..j_

,. 4.r*.- hl

!,ll

!!'l i- ! i.,

l!, l!l'._H-F M

... 9 o

'.0 i.,.- 4-*

el th w

O.

w d

w.

~}g I, eg.i Y.

l.e l

.8ri T. 7 t I M 8 8: '.N_Y. -

..,f ~T.J.O )......

, ; U:-3.! T ' P 0 Q d

.r.

p p,-

..'t.

m, s-

.. 6.a -l..."J :.. k'

.I~

, k.s..4 + ) 4' a _p

.l.9. r f 4 '.- e

-1.s: 4.j..

z

' r v.

.s -

.?. 1. L [.e

- ~ i n IFz_E.":.".u? U..

yg g

.hi

~;;= h. 2/ - 6

. u.=

+.

.4.~-

.1

.2..

a. + a. _.,

a

-s u 2..;.,.; r.2 :4. J:.. :- s =-s u.

W u

A A

i.:.

- rn r l s u.

f.n % :

...r.,..

t&

i

.. J.. r...J.

= r.it., : :: :.r} --- :---];;=-

--t. -

[

. v.. :. - n.

-: 2 W

..t 7 -=..d.... s. f m. i t

im.

m ---. t z.

;. :.: u

..: c. 4 w..- {.r.

o t-::

....ne L

... r.. : a =r

-t g y

  • t. ;;.:.;__:..a.

.-_ ~~~

.....,,,:;._..-...-. ~..+...

  • - - =

~..~n,,t_.-~....*

...-.......1.,.

  • ~q, y

,,,, ;,g; g.

... _. ~.

\\

..-...._....s,..

n Gd

~.....

4..........,.......-u.._

....e.,

  • d 3'

.. ~.

p 5 '.'I. d '.-)- - '- t- ".

-*"M.'t ~1-r j'1. '#. { r 'i ; M u s i p*-".r

-A.

.. r ; +g-ti- -

' *-r',-' / s.:

L'.

k r

3 3.-

' q 4.... r.. : 1.d.-

g X

I' p r.

.44 t * :.-

-.,.- - e f g I 4.,,D.:. 1

g. p b.g.

.l.,.. :.. p i-[.

r

.. ;..q_+

. ; n. }..

.u.'--

-54.sg.

.s3.-

  • a u : s.r. l,;d,. r,1,

,q n a. n -. :. s

6. - +...:

4

. _.:e.. 2. rw.~.yI q~.,

ts: e.

1... := p.: 2:.1 : V. u. i v

..a

...4

.t&s rJ..

.. u r 1-a ~a v c.

4

,s er r:r-r

.:-e - i:

.a. y:e:.::::.-- =

. u: 1 ).:..

.s.

. ra=

.:n.

.3..e: ;;

s.= s -

s

.t.

l ru

. r4 ;.:ne...:. - w:. :: ~t...~;;: : L" :.r..:. ::.=...r.....Lin.1.

-r ;....

. :.: : : :..,r.r.. :

... s....

...... _......... ~....... ~. _..

...._.._ L. _...

~,n..

.--~..-..-..t-..:.7.

....L.... _...

.. t o

......--r._,..._.....,..

~......

..... ~

.t.

m

.t.._.._...

.__...a..

.,. _ r...

=.-

.._..e......

.t.n.

2. 1

.. 4...

.....L m,..... +

.r..- 4..t,

w p..

7.g a... 9,1.#

_.s

. a. a.

J'

-.a.. p..

.,.v.e...t

.,. u..r..,_

...rH, r t

.. t...,

g a

.g..

.. 1,...... __..

-L.

.,, 9.

..n-

.~

.,7.T p

_q,4.g &

4.,g.A..w. g,.. H ;,,..- N - y-Fl +,

i

_....L...u. H.

L n

+=

a i

_.i., g...ya.n.., l..rs..

q q g.

..r.j..

W o

.q..

u I

o o

o o

o o

o.

m u

E w

s..

a.

.W De

  • 1 I

i',.

900131 9 v

u j

84 20 I9

~

N,= 0.028 x 6.886 x 10 a 1.933 x 10

atoms, (16)-

g The number of gram-atoms in the gap is f = 3.216 x 10 33 x 1

-5 nfp, 6.02 x 10 gram-atoms, (17) 3 The partial pressure exerted by the fission products gases is fp = nfp f (18)

P where initially, the volume, V, is taken as the 1/8-inch space between the

_ end of the fuel and the reflector end piece.

This is quite conservative because t

the graphite reflector pieces have a porosity of 20% and the fission product gases can expand into the graphite. The initial volume, then, is 0=wrh=w(1,80)2 3

3 V

0.317 cm = 3.23 cm (39) where the radius of the fuel material, r, is about 1.80 cm and the space width.

~

h, is 2/-7-inch (0.317 cm).

Thus the initial pressure exerted by all the fission product gases is 4

=3.216j310

-5 r

37, o,9,7 x 39 RT (20) 7p

~

The partial pressure of the air in the fuel element is air " 22.4 x 10-3 = 4.46 x 10-5 P

RT, (21) and the total pressure exerted by the air and fission products is 1+

P,gp = 1 + 0.007 x P

=

P,97 1.223P (22)

=

r air

(

air)

(

4.46 x 10

}

Also P Y

air = 14.7 T O

(23) g7 where P,g, is in 1b/in..and T is in *K.

90013143

~

gg n

85 The equilibrium hydrogen pressure over the U-ZrH fuel material is l.0 simply a function of the fuel temperature. At a temperature of 150*C, the

~'

hydrogen pressure is negligible (see Figure 2T).

The total gas pressure at the maximum fuel temperature of 150 C is P=Pg+P = 0 +1.223 (14.7) (15 73)3.23,

.0 psi.

(24) p Ignoring the negligible increase in volume caused by the expansion of the clad the total pressure then, is p, 90.0, 90.0, 3.23 = 27.8 psi (25) 90.0 V

VO The tangential stress in the fuel element cladding when subjected to an internal pressure, P, is S = Pr/t, (26) where r is the radius of the fuel element can (1.80 cm) and t is the wall thickness (0.076 cm) or S = 23.7P.

(27)

The stress in the cladding is S = 23.7(27.8) = 660 psi (28)

From the Aluminum Company of American handbook (4) the yield stress for type

~

1100-0 aluminum at 150*C is > 5000 psi.

Consequently, it is concluded that, subsequent to the loss of cooling water after infinite operation at 250-kw, the release of hydrogen from the fuel and the expansion of air and fission product gases in the space between fuel and graphite end pieces will not result in the rupture of the fuel element cladding.

5.1.13.

Argon Activation in Reactor Water The argon activity in the reactor pool water results from the argon dissolved in water.

In the calculation to determine the amount of argon 0ilf009 90013144

.g,

g,

86 O

u) O to O O

O O O

o O

e o

oo O % 9 R' %

? 9 R

~

~~

a

, ci o o o o

o o o

o o

o o

p.

oo c) o s

o o

cc c

s

  • e1u k#

q D/

's 6G 3

n i

.a o

r y

f, D

d r~

up

. s. s

.a O.

'k N --

p/

g N

4 s o O

S.

p/

oy tr. n 0

/

u" o.s/

o s

on o

p us w aa S.

w ca o r,

/

3 H

.s g

o</

5?>

a o ;i

- g g d: a 8o ao N

'[J e

co O C O.p/

aW o

P %

e) n :,

D

  • H O

.. e a.

n.. n.

u-

n. n n.

o p

e, ooo O

e s

ooo

'd 9

  • N*

vf i

V/

O v/ z 0

w 58,.5 e/

O.

a m

>,e:

. (:

m X

-4 o av w

o v>

T 9

9 5

o O

O

~

W.Lv '380SS3Pd git 1009 90013145 3-

87 dissolved in the pool water, the assumption was made that argon follows Henry's law.

If the water temperature is taken to be 70*F, the corresponding water vapor pressure is 26 mm Hg. The partial pressure of air is then 760 - 26

= 734 mm Hg. The argon content of air is 0.94% by volume; hence, the partial pressure of argon is 734 x (9.4 x 10-3) = 7 mm Hg.

The saturated concentration of argon in water, according to Henry's law, is X=f, (29) where X = Mole fraction of argon in water

~

P = Partial pressure of argon above water K = Henry's constant, 2.84 x 10 at 70 F.

Thus, X = 2.46 x 10 mole A per mole of (H ) + A40), or X = 1.367 x 10-8

-7 40 2

40 3

mole A per 1 cm H 0.

2 Argon-41 production, assuming saturated conditions and an irradiation

~

time t, is given by i E (I ~

  • na (30)

Nj=

3 where 4I 4I 3

N) = Atomic density of A, atoms A /cm 2

i = Average neutron flux, n/cm -sec n

40

-I E = Macroscopic absorption cross section of A cm a

4I

-I A = Decay constant for A, sec A corresponsing activity for small values of At is A) = f ate.

(31) n a

90013146 s 1. ;, ).hlElogy v-4 r

.~=--

88 12 The average thennal flux in the reactor core is estimated to be 4 x 10 2

n/cm -sec.

The water circulates in the core mainly through natural convection

~

and is estimated to change completely in 4 seconds. Since the core holds 4

3 2.4 x 10 cm of water, the rate of ' flow of water through the core is 0.6 4

3 x 10 cm /sec. Substituting appropriate values for E, and taking irradiation time as 4 seconds results in 3

Aj = 7.4 disintegrations /cm -sec (32)

The total activity from the core is thus

~

Q = 1.2pc/sec.

(33) 0 The travel time of argon-41 from the core to the water surface, a distance of 16 feet, was measured as 42 seconds. Applying the decay law, argon-41 activity reaching the surface is Q = 1.9pc/sec.

(34)

Under saturated, steady-state conditions, the maximum rate at which argon-41 can escape from the water surface will be 1.19pc/sec, and an equivalent amount

~

of argon-40 will dissolve in water in place of argon-41.

In reality, a much smaller fraction of argon-41 will escape from the water. At increased water temperature, the partial pressure of water vapor will increase and the amount of dissolved argon-40 will decrease.

~

The radioactive argon escaping from the reactor pool will dissipate in 3

the air of the reactor room. The volume of air, estimated to be 29,000 ft,

is recirculated through an air-conditioning system. Because of the high air-circulation rate, it may be assumed that argon-41 is evenly distributed through-out the entire room. The concentration of argon-41 in the air may be obtained by considering the material balance of argon-41 (in pc/sec).

dh((lOOk c)00\\5\\41

89 i

Letting Q be the production rate, P the exhaust rate and D the decay rate, the accumulation rate will be A=Q-P-D (35)

If the reactor is operated for a long time, equilibrium conditions in the air may be assumed. The accumulation rate, then, is equal to zero. Hence, Q-D = P.

From Equation (30), Q = 1.19pc/sec.

The average decay rate may be expressed as S=Q-h

-At Q

dtuc/sec, (36) e where e is the time in which decay occurs and is the average time or residence

~.

of an atom of argon-41 in the reactor room before it is vented to the atmosphere,

/

1.e.,

3 3

0 = 29,000 ft = 1.16 x 10 sec (37) 3 25 ft /sec Integrating Equation (36) and substituting in Equation (37) yields I-P=Q pc/sec (39)

Substituting for A and 0 yields P = 1.12pc/sec.

4I Since equilibrium conditions are assumed, the same concentration A will exist in the air of the reactor room as in the. exhausted air. Concentration in the exhausted air is 4

3 1.12/(25)(2.832 x 10 ) = 1.59 x 10-6 c/cm,

This is less than the maximum permissible occupational tolerance level of 3f '

-?bll.100Q

90 3

2 x 10-6 c/cm, which is recommended for a 40-hour week by the U.S. Federal Register. - Moreover, it is a upper limit since actually a much smaller amount of argon-41 than 1.19 pc/sec will escape into the air.

5.2.

Accidents Not Associated with Operation of the Reactor 5.2.1.

M_echanical Damage'to the Reactor It is conceivable that a heavy weight, such as a lead transfer cask, could be dropped on the reactor core from above and could smash the core in such a way as to change the fuel-to-water ratio. The designed fuel-to-t water ratio in the core was selected because this ratio was calculated to give very nearly the minimum critical mass. Consequently, smashing the core is likely to decrease the reactivity and at worst cannot increase it appreciably.

5.2.2.

Failure of Utilities The reactor control system is fail-safe in the event of power failure; i.e., loss of power will de-energize the magnets and release the control rods.

Loss of watdr supply or other utilities will have no effect, as the reactor will not depend upon them.

5.2.3.

Fire The building is constructed almost entirely of fireproof materials.

The load-bearing walls and the floors are of brick and reinforced concrete.

Very little inflammable material is stored in the building.

Carbon dioxide fire extinguisbers are located in laboratories and at other strategic locations. Aid from the Austin Fire Department is available in less than

~

five minutes. The possibility of fire does not contribute significantly to any radiological hazard.

5.3.

Design Basis Accident The design basis accident for this reactor system is the occurrence of a defect in the cla,dding of a fuel element either prior to or simultaneously 9001310 with a 15% 6 k k transient.

91 It is concluded that a cladding failure or even the failure of the cladding of several fuel elements would not constitute an undue hazard to

~

the operating crew or the general public.

In the event that a-defect exists in the cladding of' a fuel element at the time of pulsed operation, there may be some release of fission projucts to the atmosphere of the reactor room. Operating data have been obtained from the General Atomic TRIGA reactor to indicate the magnitude of such release.

During a higher transient than the 1.5% 6 k/k mentioned above, namely a 2.9% 6 k/k (3.90-do11ar) transient conducted as part of an extensive program of reactor transient experiments at General Atomic, a cladding failure occurred which resulted ir, the release of a minor quantity of fission

~

products.

The following summarizes the measurement made:

1.

The activity in the cooling water tank reached a maximum of 0.2 pc/ml.

It decayed very rapidly and was measured

-5 as 5x10 pc/ml 24 hr after the cladding failure.

2.

The activity in the air of the reactor room reached about ten times the MPC for fission products and decayed very rapidly.

Experiments were resumed 2 hr after the activity release. The maximum exposure to operating personnel v. s less than 1 mr.

3.

The noble gases were not collected on the filter samples

_}

used, but it may be inferred from the nature of the particulates observed that only the noble-gas fission products escape IElll009 90013150

. c.,.

,r-

6

~

92 O

9 m

~

m 10 0

~

m W

e s

10 1000 y d.

MAXIMUM

~

6 FUEL-ELEMENT TEMPERATURE 2

4 g

g g

^

~

2

/

I 10 0 I

l

\\

l POWER l

~

~

1

-l 1

I

~l

~

10 0.1 0

1 2

3 4

5 6

7 8

9 10

!I 12 TIME (SEC)

FIG. 22 TWO-DOLT.AR REACTIVITY TRANSIENT.

w

an.-

93 from the TRIGA pool in significant proportions when a fuel cladding fails.

The analysis in Section 3.1, " Reactor Laboratory," shows that no significant hazard to the public results from such an accident.

1 5.4.

Emerlency Procedures 1.

Radioactivity

'The basic philosophy in case of emergency is, first, to remove all persons to safe locations and, secondly, for qualified individuals to return cautiously for evaluation of the situation.

Possible hazards are:

(1)

Isotope spill (2) Radiolytic gas release Remote hazards are:

(1) Uncontrolled power excursion (2) Chemical reactions The amount of emergency action taken shall be based upon the most pessimistic view of the potential hazard. The Supervisor or his designated agent shall be in complete connand of all persons in the Laboratory and all actions taken in the Laboratory during an emergency.

During the emergency he shall follow orders from the Laboratory Director or from the Chairman of the Radiation Safety Connittee only if in his opinion such orders lead to a more conservative or more cautious approach to the correction of the overall situation.

There shall be three grades (or classifications) of emergency situations renging from the most minor to the maximum credible. The required action in each grade shall include all pertinent provisions of all lower grades, a.

Grade A:

This includes the most minor situations, such as a small spill of a non-volatile low-level radioactive liquid.

Whoever

~

first notices the situation is responsible for alerting all L

r j

RiflD0f 900l3152

94

\\

Others in the Laboratory. The reactor operator shall modify his plans for operation as he may deem necessary and shall be prepared to scram the reactor until the situation is remedied. The Supervisor is responsible for the evaluation and correction of the situation and for supervising all necessary monitaring, remote handling, use of protective clothing, and other health and safety measures.

b.

Grade B:

Up to 100 mr/hr Known cause.

This limiting level has been established as being near the upper limits permitted by the Nuclear Regulatory Commission and Texas Radiation Council for restricted areas if a person were to remain in the area for a period of about twelve hours per calendar quarter. This grade has been established for cautionary purposes. Occupancy of the Laboratory is restricted to employees with film badges.

c.

Grade C:

Over 100 mr/hr, or Unknown cause.

Over5000cpmonCAM)P All persons shall immediately evacuate the Laboratory into TAY 125, picking up all readily available portable survey equipment and closing the doors on their way out.

If there is any damage to the walls or roof of the Laboratory, the air-conditioning blower in room 131B shall be turned off (switch on right upon entering 131B If the situation

~

warrants, the Supervisor or his designated agent shall W U 00e 90013153

95

~

eva, uate all cdjacent rooms- (104,125,129,1318,133,135, 204). One person shall warn others not to enter the hall near the Laboratory from the north. Another will similarly guard at the corridor iiitersection adjacent to room 135.

The Supervisor or his agent will station himself, with

~

monitoring equipment, in the driveway south of the Laboratory.

If radiation levels in the corridors ad-jacent to the Laboratory approach the legal maxima for unres'tricted areas, the evacuation of all persons shall be continued as far as necessary to ensure compliance with these regulations. The following persons shall be notified:

(1) Laboratory Supervisor:

Joseph A. Burad CTX 5136 (2) Laboratory Director Dale E. Klein CTX 5136 (459-0075)

(3) Radiation Safety Officer:

Bill Bryant CTX 4601 and 3511 (452-6689)

(4) Chief, Traffic & Security Officer (Chief, University Police) bbfhonjl,d(R. Cannon CTX 4441 PAX 1031 (836-4089)

(5) Radiation Control Division of State Health Department:

Martin C. Wukasch 454-3781, ext. 241 (465-5437)

(6)

Laboratory Technician:

Bob B. Tomlin CTX5136(321-3560)

At his discretion, the Chief Traffic and Security Officer may request assistance from the City of Austin Police and Fire Departments.

90013154 L

M

96 If Laboratory personnel are unable to obtain sufficient survey equipment and/or protective clothing during the evacuation, such items shall be requested from the Radiation Safety Officer or the Radiation Control Division. At least once cach calerdar quarter the emergency procedures as outlined above shall be reviewed by the employees involved.

2.

Fire and Other Hazards In case of fire or other hazards not directly associated with radiation, the general procedure will be to scram the reactor and notify the Fire Marshal (CTX 3511) or the Chief, University Police (CTX 3511 and 4441). The Supervisor or his designated agent shall have the same authority and responsibility as he has in the case of a radiation hazard. He shall decide the type and extent of action to be taken based upon the location and characteristics of the hazard.

At least two carbon dioxide fire extinguishers shall be maintained 9

in readiness in the Laboratory area.

.M I

R11100?

i

'em>

.