General Electric Company ADDENDUM TO MAY 2019 CLEANUP PLAN Former United Nuclear Corporation Naval Products Facility New Haven, Connecticut April 27, 2020
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_Rpt_04.27.2020.docx i
CONTENTS Acronyms and Abbreviations........................................................................................................................ ii 1
Introduction............................................................................................................................................ 1 2
Solid Materials Release Criteria............................................................................................................ 1 3
Waste Assessment and Disposal Options............................................................................................ 2 4
Revised Figures and Tables from May 2019 Cleanup Plan................................................................. 3 5
References............................................................................................................................................ 3 FIGURE Figure 1. Soil and Trench Sample Layout APPENDICES Appendix A. Revised Figures and Tables from May 2019 Cleanup Plan Appendix B. Site Background, and Sampling Methodology and Results
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_Rpt_04.27.2020.docx ii ACRONYMS AND ABBREVIATIONS Arcadis Arcadis U.S., Inc.
cm2 centimeters squared dpm disintegration per minute dpm/100 cm2 disintegrations per minute per 100 square centimeter area HEU highly enriched uranium MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual NRC United States Nuclear Regulatory Commission RCRA Resource Conservation and Recovery Act site former United Nuclear Corporation Naval Products Facility, located in New Haven, Connecticut USEPA United States Environmental Protection Agency
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_Rpt_04.27.2020.docx 1
1 INTRODUCTION On behalf of the General Electric Company, Arcadis U.S., Inc. (Arcadis) has prepared this Addendum to the May 2019 Cleanup Plan (Addendum) for the former United Nuclear Corporation Naval Products Facility, located in New Haven, Connecticut (Site).
The project was initiated in September 2019, and work has progressed in accordance with the May 2019 Cleanup Plan (Cleanup Plan). To date, the above-grade portions of Building 3H and Building 6H; and the at-grade concrete slab, underlying trenches and foundations, and soil associated with Building 3H and a portion of Building 6H immediately adjacent to Building 3H have been transported offsite for disposal at approved disposal facilities.
Based on the analytical results from the previous building characterization activities performed in 2018/2019 and presented in the Cleanup Plan, and recent comprehensive intrusive sampling activities (March/April 2020), the concrete slab in the remaining portion of Building 6H is not impacted by radiological or hazardous constituents and is amenable to off-site disposal as non-hazardous/non-radioactive waste. It is also anticipated that the sub-slab features beneath the remaining slab (i.e., building and equipment foundations and portions of the trench structures), as well as the underlying soil will not be impacted, and that they will also be amenable to disposal as non-hazardous/non-radioactive waste. As discussed in this Addendum, additional characterization of the sub-slab features and underlying soil will be performed once accessible to confirm this assumption and prior to off-site disposal.
The purpose of this Addendum is to include waste material release criteria and additional disposal options for the non-hazardous/non-radioactive waste materials associated with the remaining portions of Building 6H and underlying materials. Appendix A of this Addendum also includes revisions to the figures and tables that were included in the Cleanup Plan; the revisions reflect sample labeling nomenclature.
2 SOLID MATERIALS RELEASE CRITERIA According to NUREG-1757 Consolidated Decommissioning Guidance: Decommissioning Process for Material Licensees (NRC,2006) solid materials may be released from licensed operation with the acknowledgement that the material may contain very low levels of radioactivity. Furthermore, Fuel Cycle Policy and Guidance Directive (FC 83-23) Guidelines for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of Licenses for Byproduct, Source, or Special Nuclear Material (NRC 1993) establishes surface contamination limits for natural uranium, U-235, U-238 and associated decay products (Table 1).
Table 1. FC 83-23 Acceptable Surface Contamination Levels Nuclidesa Averageb, c, f Maximumb, d, f Removableb, e, f Natural uranium, U-235, U-238 and associated decay products 5,000 dpm /100 cm2 15,000 dpm /100 cm2 1,000 dpm /100 cm2
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_Rpt_04.27.2020.docx 2
Notes for Table 1 are as follows:
a where surface contamination by both alpha-and beta-gamma emitting nuclides exists, the limits for alpha-and beta-gamma-emitting nuclides should be applied independently.
b As used in this table, dpm (disintegrations per minute) means the rate of emission by radioactive materials as determined by correcting the counts per minute observed by the detector for background, efficiency, and geometric factors associated with the instrumentation.
c Measurements of average contaminant should not be averaged over more than 1 square meter.
For objects of less surface area, the average should be derived or each such object.
d The maximum contamination level applies to the area not more than 100 cm2.
e The amount of removable radioactive material per 100 cm2 of surface area should be determined by wiping that area with dry filter or soft absorbent paper, applying moderate pressure, and assessing the amount of radioactive material on the wipe with an appropriate instrument of know efficiency. When removal contamination on objects of less surface area is determined, the pertinent levels should be reduced proportionally, and the entire surface should be wiped.
f The average and maximum radiation levels associated with surface contamination results in from beta-gamma emitters should not exceed 0.2 mrad/hr at 1 cm and 1.0 mrad/hr at 1 cm, respectively, measured through not more than 7 milligrams per square centimeter of total absorber.
For solid materials such as concrete, these materials may be surveyed using a representative sample and gamma spectroscopy methods (NRC,2002). NUREG-1757 (NRC,2006) specifies that materials can be released if no radioactive material is above natural background levels. The background soil concentration for the Site was previously determined and accepted by NRC as 3.43 picocurie per gram (pCi/gram) uranium (AAA/IEM, 2005).
3 WASTE ASSESSMENT AND DISPOSAL OPTIONS The results of the radiological surveys performed for Building 6H concrete slabs in March/April 2020 meet the release criteria presented in Section 2. In addition, sampling of the concrete for non-radiological parameters determined (as anticipated) that the concrete is not a hazardous waste. As a result, this material is suitable for local off-site disposal at Modern Materials Corporation in Hamden, Connecticut or another Connecticut--based or out-of-state recycling facility permitted to accept this material. Sampling results and protocols (e.g., number of sample locations, sample collection, radiological measurements, and analytical parameters) are presented in Appendix B.
Once the remaining slabs are removed, the sub-slab features (e.g., concrete equipment foundations and trenches) and underlying soil associated with Building 6H will be assessed for the presence of radiological and hazardous constituents using the same sampling approach and methodologies that were applied to the concrete slab in Building 6H (Appendix B). Evaluation of the materials as possible hazardous waste will be through visual inspection and sampling and analytical determination for total PCBs and Toxicity Characteristic Leachate Procedure (TCLP) analyses for VOCs, SVOC, and Inorganics.
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_Rpt_04.27.2020.docx 3
Assessment of the sub-slab features will be accomplished through grab and composite sample collection and both radiation and non-radiation laboratory analyses as described below:
For soil underlying the concrete slabs, composite sample collections within each subarea will follow the grid used for the slab, as presented on Figure 1, except in locations where trench or equipment foundations are encountered during slab removal operations.
Surface contamination of concrete equipment foundations will be analyzed prior to breaking up the concrete for removal purposes. Fixed and removable alpha surveys will be performed in a systematic grid, depending upon the size of the foundation.
Volumetric concrete sample of foundations will be taken as appropriate. Concrete samples will be collected from equipment foundations and trenches (if they are present), depending on size. Discrete samples will be collected from equipment foundations less than 400 square feet and trenches up to 20 feet long, otherwise a minimum two-point composite concrete samples will be collected.
If the results of the assessment sampling activities meet the waste release criteria discussed in Section 2, these materials can also be disposed of as non-hazardous/non-radioactive waste materials at Modern Materials Corporation or another Connecticut-based or out-of-state recycling facility that can accept this material.
4 REVISED FIGURES AND TABLES FROM MAY 2019 CLEANUP PLAN In response to a recent on-site audit comments provided by NRC, the figures and tables associated with May 2019 Cleanup Plan submittal have been revised so that all sampling nomenclature is consistent. The revised figures and tables are contained in Appendix A.
5 REFERENCES AAA/IEM, 2005 Integrated Environmental Management, Inc. Radiological Characterization of the Former UNC Manufacturing Facility, new Haven Connecticut AAA Environmental, Inc./Integrated Environmental Management, Inc. May 31, 2005.
Arcadis, 2019, Cleanup Plan Former United Nuclear Corporation Naval Products Facility, New Haven, Connecticut NRC, 1983 FC 83-23, Fuel Cycle Policy and Guidance Directive Guidelines for Decontamination of Facilities and Equipment Prior Release for Unrestricted Use or Termination of Licenses for Byproduct or source Materials, April.
NRC,2002, NQR 2002, Memorandum To: John W. Craig, et. al From: Donald A. Cool Re: Update On Case-Specific Licensing Decisions On Controlled Release Of Concrete from Licensed Facilities, December.27, 2002 NRC, 2006 NUREG-1757 Consolidated Decommissioning Guidance-Decommissioning Process for Material Licensees. Vol 1 Revision 2, 2006
FIGURE
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SPRINKLER CONTROL OPEN PIPE GAS VALVE FARMINGTON CANAL GREENWAY SHELTON AVENUE BUILDING 3H SLAB, FOUNDATION, AND SOIL REMOVAL COMPLETE N8 N7 N6 N5 N4 S8 S7 S6 S5 S4 BUILDING 6H WEST BUILDING 6H EAST NT8 NT7 NT6 NT5 NT4 ST8 ST6 ST4 LTN LTS ST7 ST5 FIGURE SOIL AND TRENCH SAMPLE LAYOUT FORMER UNITED NUCLEAR CORPORATION FACILITY 71 SHELTON AVENUE NEW HAVEN, CONNECTICUT 1
CITY: SYRACUSE, NY DIV/GROUP: EBC-IM/DV DB: L.POSENAUER PM/TM: R.GIAMPAOLO LYR:(Opt)ON=*;OFF=*REF*
C:\\Users\\ssteele\\BIM 360\\Arcadis\\ANA - GE CORP ENV PROG\\Project Files\\GE UNC NEW HAVEN - ENGINEERING\\2020\\30006255\\01-DWG\\GE-UNC_SITE SAMPLE LAYOUTdwg.dwg LAYOUT: 1 SAVED: 4/22/2020 7:48 AM ACADVER: 23.0S (LMS TECH) PAGESETUP: ---- PLOTSTYLETABLE: ACAD.CTB PLOTTED: 4/23/2020 12:47 PM BY: STEELE, SAM N8 NT8 ST8 LTS
APPENDIX A Revised Figures and Tables from Cleanup Plan
1 2
3 4
5 6
7 8
9 10 11 12 13 14 MEN WOMEN POWDER FACILITY ZIRK STORAGE VAC. ANNEAL CHEMISTRY ELEMENT MANUFACTURING METAL OVERHEAD DOOR METAL FIRE DOOR FIGURE 1
CITY: SYRACUSE, NY DIV/GROUP: EBC-IM/DV DB: L.POSENAUER PM/TM: R.GIAMPAOLO LYR:(Opt)ON=*;OFF=*REF*
C:\\BIM\\OneDrive - ARCADIS\\BIM 360 Docs\\ANA - GE CORP ENV PROG\\GE FMR UNC FACILITY NEW HAVEN CT\\2019\\ALL31350.2000\\01-DWG\\GE-UNC_FIG 1-2-3_BUILDING SAMPLES.dwg LAYOUT: 1 SAVED: 2/20/2019 9:35 AM ACADVER: 23.0S (LMS TECH) PAGESETUP: C-LB-PDF PLOTSTYLETABLE: PLTFULL.CTB PLOTTED: 2/20/2019 12:24 PM BY: POSENAUER, LISA BUILDING 6H WEST FORMER UNC FACILITY 71 SHELTON AVENUE NEW HAVEN, CONNECTICUT DRAFT MATCHLINE TO BUILDING 6H EAST 6HW-WS-02-1221 6HW-WS-01-1221 6HW-FS-01-1221 6HW-WALL-01-1221 (sheetrock) 6HW-FS-03-1221 6HW-FD-03-1221 6HW-WS-04-1221 6HW-CG-01-1220 (Exterior Support Column) 6HW-FS-02-1221 6HW-WS-03-1221 6HW-WD-03-1221 6HW-FS-04-1221 6HW-FS-05-1221 6HW-WS-05-1220 Building Section: 6HW Sample Locations Sample Designation Building Section Floor (or W - Wall)
Systematic (or B - Biased, D - Duplicate)
Sample number MMDD 6HW-FS-01-1217 Additional Sample Designations WALL - wall covering CG - Caulking R/RW - Built-up Roofing, Wood Roof Decking WC - Waste Characterization FD - Field Duplicate 6HW-WS-06-1221 6HS-FS-05-0404 6HS-FS-04-0404 6HS-FS-06-0404
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 ELEMENT STORAGE CHEMISTRY LAB WOMEN VAULT PRODUCTION OFFICE PACK ASSEMBLY LOCKERS PICKLE AREA X-RAY VAC. ANNEAL VAPOR BLASTER FIGURE 2
CITY: SYRACUSE, NY DIV/GROUP: EBC-IM/DV DB: L.POSENAUER PM/TM: R.GIAMPAOLO LYR:(Opt)ON=*;OFF=*REF*
C:\\BIM\\OneDrive - ARCADIS\\BIM 360 Docs\\ANA - GE CORP ENV PROG\\GE FMR UNC FACILITY NEW HAVEN CT\\2019\\ALL31350.2000\\01-DWG\\GE-UNC_FIG 1-2-3_BUILDING SAMPLES.dwg LAYOUT: 2 SAVED: 2/18/2019 4:01 PM ACADVER: 23.0S (LMS TECH) PAGESETUP: C-LB-PDF PLOTSTYLETABLE: PLTFULL.CTB PLOTTED: 2/18/2019 4:01 PM BY: POSENAUER, LISA BUILDING 6H EAST FORMER UNC FACILITY 71 SHELTON AVENUE NEW HAVEN, CONNECTICUT DRAFT MATCHLINE TO BUILDING 6H WEST MATCHLINE TO BUILDING 3H Building Section: 6HE Sample Locations 6HE-FS-01-1220 6HE-CG-02-1220 (Floor Expansion Joint) 6HE-WS-01-1221 6HE-FS-03-1220 6HE-FS-04-1220 6HE-WS-02-1220 6HE-WS-03-1220 6HE-PC-01-1219 (Roof Truss) 6HE-FS-05-1219 6H-R-01-1221 6H-RW-01-1221 (Roof) 6HE-PC-03-1219 (Crane Rail Support) 6HE-FS-06-1220 6HE-CG-01-1220 (Window glazing) 6HE-FS-07-1220 6HE-PC-02-1219 (Roof Truss) 6HE-WS-05-1220 6HE-WS-06-1220 6HE-FS-08-1220 Sample Designation Building Section Floor (or W - Wall)
Systematic (or B - Biased, D - Duplicate)
Sample number MMDD 6HW-FS-01-1217 Additional Sample Designations WALL - wall covering CG - Caulking R/RW - Built-up Roofing, Wood Roof Decking WC - Waste Characterization FD - Field Duplicate 6HS-FS-01-0404 6HS-FS-02-0404 6HS-FS-03-0404
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 LOCKER ROOM VAULT OFFICE OFFICE X-RAY READING AREA STORAGE MACHINING AREA DECON AREA HEAT EXCH.
OFFICE Q.C.
NSP SUIT-UP ROOM LOCKER ROOM HAND FINISH FUEL STORAGE IN-FAB FACILITY FORMER OVERHEAD DOOR (OPEN)
METAL FIRE DOOR METAL FIRE DOOR WOOD OVERHEAD DOOR UNC-GWS-35 20 23 34 39 44 74 152 UNC-GWS-34 UNC-GWS-43 FIGURE 3
CITY: SYRACUSE, NY DIV/GROUP: EBC-IM/DV DB: L.POSENAUER PM/TM: R.GIAMPAOLO LYR:(Opt)ON=*;OFF=*REF*
C:\\BIM\\OneDrive - ARCADIS\\BIM 360 Docs\\ANA - GE CORP ENV PROG\\GE FMR UNC FACILITY NEW HAVEN CT\\2019\\ALL31350.2000\\01-DWG\\GE-UNC_FIG 1-2-3_BUILDING SAMPLES.dwg LAYOUT: 3 SAVED: 2/18/2019 4:01 PM ACADVER: 23.0S (LMS TECH) PAGESETUP: C-LB-PDF PLOTSTYLETABLE: PLTFULL.CTB PLOTTED: 2/18/2019 4:01 PM BY: POSENAUER, LISA BUILDING 3H FORMER UNC FACILITY 71 SHELTON AVENUE NEW HAVEN, CONNECTICUT DRAFT MATCHLINE TO BUILDING 6H EAST 3H-WS-01-1217 3H-WS-03-1217 3H-WS-02-1217 3H-WB-01-1217 3H-FB-01-1220 3H-FS-02-1220 3H-CG-04-1220 (Base of Wall) 3H-FB-0203-1220 3H-FB-04-1220 3H-FB-0506-1219 FD-01 3H-FB-07-1217 3H-FB-11-1217 3H-FB-09-1217 3H-FB-10-1217 3H-FB-12-1217 3H-FB-08-1217 3H-WB-05-1217 3H-WB-02-1220 3H-WB-03-1217 3H-WB-04-1217 3H-CG-02-1220 (Interior window glaze) 3H-FS-13-1217 3H-WS-12-1217 3H-WS-13-1217 3H-FS-12-1217 3H-PC-02-1220 (Crane Rail Support) 3H-PC-01-1220 (Crane Rail Support) 3H-FS-10-1217 3H-FS-11-1217 3H-FS-09-1217 3H-FS-07-1219 3H-WS-10-1217 3H-WS-08-1217 3H-W-WC-01-1221 3H-F-WC-01-1221 3H-WS-06-1219 3H-WS-04-1220 3H-FS-04-1220 3H-FS-06-1220 3H-FS-08-1217 3H-FS-03-1220 3H-FS-05-1220 3H-FS-01-1220 3H-R-01-1220 3H-R-02-1220 (Roof)
Sample Designation Building Section Floor (or W - Wall)
Systematic (or B - Biased, D - Duplicate)
Sample number MMDD 6HW-FS-01-1217 Additional Sample Designations WALL - wall covering CG - Caulking R/RW - Built-up Roofing, Wood Roof Decking WC - Waste Characterization FD - Field Duplicate 3H-WS-05-1219 3H-WS-07-1220 3H-WS-09-1217 3H-WS-11-1217 Building Section: 3H Sample Locations 3H-CG-03-1221
Table 2-3a Cleanup Plan Appendix A - Building Characterization Survey Radiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-FB-01 3H-FB-04 3H-FB-07 3H-FB-08 3H-FB-09 Date Collected:
12/20/18 12/20/18 12/20/18 12/19/18 12/19/18 12/17/18 Sample Name:
3H-CG-02-1220 3H-FB-01-1220 3H-FB-04-1220 3H-FB-07-1217 3H-FB-08-1217 3H-FB-09-1217 Radiochem-Alpha Spectrometry Uranium-238 0.200 +/-0.0863 0.495 +/-0.149 0.300 +/-0.109 0.249 +/-0.0918 0.308 +/-0.110 0.393 +/-0.121 Uranium-234 0.506 +/-0.142 48.7 +/-4.33 1.46 +/-0.259 1.67 +/-0.272 11.7 +/-1.18 0.592 +/-0.151 Uranium-235 0.00525 U +/-0.0223 2.37 +/-0.388 0.0195 U +/-0.0321 0.0675 +/-0.0535 0.491 +/-0.154 0.0212 U +/-0.0301 Radiochem-Gamma Emitters Uranium-238 NA 0.0321 U G +/-0.0990 0.467 U +/-0.525 0.484 U +/-0.432
-1.280 U G +/-0.875
-0.24400 U +/-0.713 Uranium-235 NA 2.64 +/-0.518 0.135 U +/-0.269 0.0404 U +/-0.139 2.92 +/-0.553 0.0580 U +/-0.164 Radiochem-Gamma Emitters-TICs Actinium-228 NA 0.626 +/-0.183 0.288 +/-0.145 NA 0.524 +/-0.148 0.487 +/-0.113 Bismuth-212 NA NA NA NA NA NA Bismuth-214 NA NA NA 0.296 +/-0.107 0.380 +/-0.112 0.283 +/-0.101 Lead-210 NA NA 2.23 +/-0.932 NA NA NA Lead-212 NA 0.463 +/-0.105 0.399 +/-0.0898 NA 0.524 +/-0.102 0.387 +/-0.0767 Lead-214 NA 0.283 +/-0.115 0.244 +/-0.0897 NA 0.404 +/-0.110 0.275 +/-0.0738 Potassium-40 NA 6.45 +/-1.36 6.91 +/-1.22 6.98 +/-1.26 8.20 +/-1.35 4.53 +/-0.864 Thallium-208 NA 0.169 +/-0.0643 0.124 +/-0.0459 0.175 +/-0.0592 0.235 +/-0.0684 0.121 +/-0.0362 Location ID:
3H-FB-10 3H-FB-11 3H-FB-12 3H-FB-0203 3H-FB-0506 3H-FS-01 Date Collected:
12/17/18 12/19/18 12/18/18 12/20/18 12/19/18 12/20/18 Sample Name:
3H-FB-10-1217 3H-FB-11-1217 3H-FB-12-1217 3H-FB-0203-1220 3H-FB-0506-1220 3H-FS-01-1220 Radiochem-Alpha Spectrometry Uranium-238 0.490 +/-0.135 0.266 +/-0.109 0.803 +/-0.173 0.179 +/-0.0883 0.235 +/-0.0919 NA Uranium-234 0.376 +/-0.118 6.44 +/-0.750 98.5 +/-8.46 0.535 +/-0.158 0.868 +/-0.186 NA Uranium-235 0.0416 +/-0.0418 0.293 +/-0.127 4.41 +/-0.553 0.0255 U +/-0.0361 0.0285 U +/-0.0363 NA Radiochem-Gamma Emitters Uranium-238 0.161 U +/-0.350 1.74 +/-0.648 0.195 U +/-0.323 0.223 U +/-0.290
-0.0989000 U +/-0.122 0.297 U +/-0.444 Uranium-235
-0.001930000 U +/-0.00406 1.57 +/-0.338 4.67 +/-0.619
-0.12900 U +/-0.364 0.167 U +/-0.310 0.237 +/-0.140 Radiochem-Gamma Emitters-TICs Actinium-228 0.453 +/-0.143 0.559 +/-0.269 0.478 +/-0.190 0.531 +/-0.139 0.411 +/-0.192 0.614 +/-0.181 Bismuth-212 NA NA NA NA NA NA Bismuth-214 0.247 +/-0.0845 0.345 +/-0.139 0.323 +/-0.0886 0.292 +/-0.0903 0.357 +/-0.124 0.257 +/-0.112 Lead-210 NA NA NA NA NA NA Lead-212 0.357 +/-0.0853 0.414 +/-0.101 0.336 +/-0.0816 0.365 +/-0.0744 0.407 +/-0.0949 0.414 +/-0.0932 Lead-214 0.338 +/-0.0837 NA 0.346 +/-0.0808 0.247 +/-0.0750 0.393 +/-0.125 0.269 +/-0.0886 Potassium-40 4.70 +/-1.02 6.42 +/-1.37 5.54 +/-1.05 5.28 +/-0.965 5.52 +/-1.06 6.54 +/-1.36 Thallium-208 0.121 +/-0.0450 0.149 +/-0.0576 0.157 +/-0.0528 0.177 +/-0.0507 0.127 +/-0.0505 0.222 +/-0.0617 Location ID:
3H-FS-02 3H-FS-03 3H-FS-04 3H-FS-05 3H-FS-06 3H-FS-07 Date Collected:
12/20/18 12/20/18 12/20/18 12/20/18 12/20/18 12/19/18 Sample Name:
3H-FS-02-1217 3H-FS-03-1220 3H-FS-04-1220 3H-FS-05-1220 3H-FS-06-1220 3H-FS-07-1219 Radiochem-Alpha Spectrometry Uranium-238 NA NA NA NA NA NA Uranium-234 NA NA NA NA NA NA Uranium-235 NA NA NA NA NA NA Radiochem-Gamma Emitters Uranium-238
-0.64900 U +/-0.857 0.354 U +/-0.377 0.473 U +/-0.547
-0.17800 U G +/-0.727
-1.510 U +/-0.599
-0.44600 U +/-0.472 Uranium-235 0.303 +/-0.194 0.144 U +/-0.139
-0.16300 U +/-0.531 2.46 +/-0.390 0.383 +/-0.180
-0.10200 U +/-0.225 Radiochem-Gamma Emitters-TICs Actinium-228 0.541 +/-0.145 0.586 +/-0.143 0.493 +/-0.158 0.417 +/-0.123 0.563 +/-0.148 0.499 +/-0.108 Bismuth-212 NA NA NA NA NA NA Bismuth-214 0.344 +/-0.115 NA 0.473 +/-0.131 0.250 +/-0.0957 0.289 +/-0.0912 0.388 +/-0.104 Lead-210 NA NA NA NA NA NA Lead-212 0.462 +/-0.0965 0.398 +/-0.0914 0.471 +/-0.0979 0.416 +/-0.0816 0.372 +/-0.0865 0.279 +/-0.0765 Lead-214 0.329 +/-0.101 0.301 +/-0.109 0.341 +/-0.121 0.348 +/-0.0802 0.254 +/-0.0861 0.323 +/-0.0801 Potassium-40 7.42 +/-1.26 6.36 +/-1.21 7.49 +/-1.28 8.10 +/-1.25 5.33 +/-1.10 6.64 +/-1.20 Thallium-208 0.197 +/-0.0608 0.171 +/-0.0592 0.198 +/-0.0530 0.140 +/-0.0455 0.128 +/-0.0540 0.140 +/-0.0479 C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 1/20
Table 2-3a Cleanup Plan Appendix A - Building Characterization Survey Radiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-FS-08 3H-FS-09 3H-FS-10 3H-FS-11 3H-FS-12 3H-FS-13 Date Collected:
12/19/18 12/18/18 12/18/18 12/17/18 12/17/18 12/17/18 Sample Name:
3H-FS-08-1217 3H-FS-09-1217 3H-FS-10-1217 3H-FS-11-1217 3H-FS-12-1217 3H-FS-13-1217 Radiochem-Alpha Spectrometry Uranium-238 NA NA NA NA NA NA Uranium-234 NA NA NA NA NA NA Uranium-235 NA NA NA NA NA NA Radiochem-Gamma Emitters Uranium-238 0.515 U +/-0.420 0.102 U +/-0.410 0.394 U +/-0.510 0.371 U +/-0.488 0.137 U +/-0.136 0.285 U +/-0.379 Uranium-235 0.0390 U +/-0.182 0.0840 U +/-0.274 0.0823 U +/-0.256 0.0824 U +/-0.265 0.113 U +/-0.0842 0.00533 U +/-0.0161 Radiochem-Gamma Emitters-TICs Actinium-228 NA 0.653 +/-0.150 0.425 +/-0.155 0.366 +/-0.175 NA 0.491 +/-0.143 Bismuth-212 NA NA NA NA 0.665 +/-0.327 NA Bismuth-214 0.299 +/-0.127 0.347 +/-0.113 0.388 +/-0.121 NA 0.306 +/-0.102 0.287 +/-0.105 Lead-210 NA NA NA NA NA NA Lead-212 0.432 +/-0.0967 0.398 +/-0.0874 0.437 +/-0.0937 0.255 +/-0.0827 0.260 +/-0.0700 0.443 +/-0.0991 Lead-214 NA 0.290 +/-0.0928 0.367 +/-0.108 0.281 +/-0.0883 0.347 +/-0.0847 0.374 +/-0.0975 Potassium-40 6.49 +/-1.36 5.62 +/-1.21 5.72 +/-1.37 5.84 +/-1.33 5.36 +/-1.03 7.04 +/-1.35 Thallium-208 0.170 +/-0.0546 NA 0.221 +/-0.0663 0.165 +/-0.0507 0.127 +/-0.0509 0.170 +/-0.0619 Location ID:
3H-PC-01 3H-R-01 3H-R-02 3H-WB-01 3H-WB-02 3H-WB-03 Date Collected:
12/20/18 12/20/18 12/20/18 12/19/18 12/20/18 12/18/18 Sample Name:
3H-PC-01-1220 3H-R-01-1220 3H-R-02-1220 3H-WB-01-1217 3H-WB-02-1220 3H-WB-03-1217 Radiochem-Alpha Spectrometry Uranium-238 0.413 +/-0.120 0.0391 U +/-0.0372 0.0197 U +/-0.0280 0.374 +/-0.116 0.532 +/-0.136 0.751 +/-0.174 Uranium-234 49.9 +/-4.37 0.0557 U +/-0.0478 0.0495 U +/-0.0462 3.84 +/-0.478 60.0 +/-5.21 1.04 +/-0.209 Uranium-235 1.83 +/-0.300 0.0154 U +/-0.0300 0.0197 U +/-0.0279 0.171 +/-0.0870 2.52 +/-0.372 0.00537 U +/-0.0228 Radiochem-Gamma Emitters Uranium-238 NA NA NA 0.404 U +/-0.466 1.02 U +/-0.681 0.933 U +/-0.649 Uranium-235 NA NA NA 0.0866 U +/-0.206 3.62 +/-0.520
-0.37800 U G +/-0.445 Radiochem-Gamma Emitters-TICs Actinium-228 NA NA NA 0.916 +/-0.210 1.19 +/-0.239 1.69 +/-0.390 Bismuth-212 NA NA NA NA 1.46 +/-0.695 2.44 +/-0.882 Bismuth-214 NA NA NA NA 0.717 +/-0.155 1.15 +/-0.254 Lead-210 NA NA NA NA NA NA Lead-212 NA NA NA 0.658 +/-0.129 1.04 +/-0.154 1.45 +/-0.229 Lead-214 NA NA NA 0.504 +/-0.121 0.792 +/-0.157 1.27 +/-0.276 Potassium-40 NA NA NA 14.0 +/-2.12 16.4 +/-2.40 27.2 +/-3.90 Thallium-208 NA NA NA 0.320 +/-0.0802 0.327 +/-0.0823 0.556 +/-0.127 Location ID:
3H-WB-04 3H-WB-05 3H-WS-01 3H-WS-02 3H-WS-03 3H-WS-04 Date Collected:
12/18/18 12/17/18 12/18/18 12/19/18 12/19/18 12/20/18 Sample Name:
3H-WB-04-1217 3H-WB-05-1217 3H-WS-01-1217 3H-WS-02-1217 3H-WS-03-1217 3H-WS-04-1220 Radiochem-Alpha Spectrometry Uranium-238 0.280 +/-0.102 0.772 +/-0.171 0.387 +/-0.122 0.347 +/-0.108 0.435 +/-0.128 0.530 +/-0.137 Uranium-234 0.383 +/-0.119 0.661 +/-0.156 9.14 +/-0.942 13.1 +/-1.27 1.67 +/-0.279 0.781 +/-0.171 Uranium-235
-0.002600000 U +/-0.00521 0.0290 U +/-0.0399 0.298 +/-0.116 0.416 +/-0.130 0.0537 +/-0.0482 0.0147 U +/-0.0286 Radiochem-Gamma Emitters Uranium-238 0.982 U +/-0.587 0.655 U +/-1.01 NA NA NA NA Uranium-235 0.158 U +/-0.417
-0.10700 U G +/-1.31 NA NA NA NA Radiochem-Gamma Emitters-TICs Actinium-228 1.20 +/-0.231 1.63 +/-0.400 NA NA NA NA Bismuth-212 NA NA NA NA NA NA Bismuth-214 1.02 +/-0.193 1.07 +/-0.300 NA NA NA NA Lead-210 NA NA NA NA NA NA Lead-212 1.24 +/-0.202 1.57 +/-0.264 NA NA NA NA Lead-214 1.07 +/-0.188 1.19 +/-0.298 NA NA NA NA Potassium-40 21.1 +/-2.81 26.3 +/-4.08 NA NA NA NA Thallium-208 0.443 +/-0.0988 0.475 +/-0.128 NA NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 2/20
Table 2-3a Cleanup Plan Appendix A - Building Characterization Survey Radiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-WS-05 3H-WS-06 3H-WS-07 3H-WS-08 3H-WS-09 3H-WS-10 Date Collected:
12/19/18 12/19/18 12/20/18 12/19/18 12/18/18 12/19/18 Sample Name:
3H-WS-05-1219 3H-WS-06-1219 3H-WS-07-1220 3H-WS-08-1217 3H-WS-09-1217 3H-WS-10-1217 Radiochem-Alpha Spectrometry Uranium-238 0.837 +/-0.175 0.372 +/-0.114 0.385 +/-0.113 0.703 +/-0.156 0.548 +/-0.138 0.640 +/-0.153 Uranium-234 0.831 +/-0.174 3.34 +/-0.433 0.480 +/-0.126 0.964 +/-0.187 0.931 +/-0.187 0.665 +/-0.158 Uranium-235 0.0355 U +/-0.0383 0.0983 +/-0.0645 0 U +/-0.00462 0.0455 +/-0.0409 0.0550 +/-0.0473 0.0350 U +/-0.0407 Radiochem-Gamma Emitters Uranium-238 NA NA NA NA NA NA Uranium-235 NA NA NA NA NA NA Radiochem-Gamma Emitters-TICs Actinium-228 NA NA NA NA NA NA Bismuth-212 NA NA NA NA NA NA Bismuth-214 NA NA NA NA NA NA Lead-210 NA NA NA NA NA NA Lead-212 NA NA NA NA NA NA Lead-214 NA NA NA NA NA NA Potassium-40 NA NA NA NA NA NA Thallium-208 NA NA NA NA NA NA Location ID:
3H-WS-11 3H-WS-12 3H-WS-13 6HE-FS-01 6HE-FS-02 6HE-FS-03 Date Collected:
12/19/18 12/18/18 12/18/18 12/20/18 12/21/18 12/20/18 Sample Name:
3H-WS-11-1217 3H-WS-12-1217 3H-WS-13-1217 6HE-FS-01-1220 6HE-FS-02-1221 6HE-FS-03-1220 Radiochem-Alpha Spectrometry Uranium-238 0.843 +/-0.184 0.404 +/-0.122 0.208 +/-0.0846 NA NA NA Uranium-234 0.703 +/-0.170 0.481 +/-0.134 0.513 +/-0.135 NA NA NA Uranium-235 0.00527 U +/-0.0224 0.0287 U +/-0.0367 0.0198 U +/-0.0280 NA NA NA Radiochem-Gamma Emitters Uranium-238 NA NA NA 0.529 U +/-0.561 0.328 U +/-0.366 0.201 U +/-0.374 Uranium-235 NA NA NA
-0.22800 U +/-0.229 0 U +/-0.120 0.0457 U +/-0.271 Radiochem-Gamma Emitters-TICs Actinium-228 NA NA NA 0.541 +/-0.193 0.617 +/-0.149 0.554 +/-0.175 Bismuth-212 NA NA NA NA NA NA Bismuth-214 NA NA NA 0.389 +/-0.143 0.271 +/-0.0823 NA Lead-210 NA NA NA NA NA NA Lead-212 NA NA NA 0.516 +/-0.113 0.484 +/-0.0929 0.398 +/-0.0971 Lead-214 NA NA NA 0.353 +/-0.126 0.240 +/-0.0751 0.272 +/-0.109 Potassium-40 NA NA NA 6.86 +/-1.35 8.06 +/-1.32 6.01 +/-1.25 Thallium-208 NA NA NA 0.183 +/-0.0616 0.154 +/-0.0424 0.175 +/-0.0583 Location ID:
6HE-FS-04 6HE-FS-05 6HE-FS-06 6HE-FS-07 6HE-FS-08 6HE-PC-01 Date Collected:
12/20/18 12/19/18 12/20/18 12/20/18 12/20/18 12/19/18 Sample Name:
6HE-FS-04-1220 6HE-FS-05-1219 6HE-FS-06-1220 6HE-FS-07-1220 6HE-FS-08-1220 6HE-PC-01-1219 Radiochem-Alpha Spectrometry Uranium-238 NA NA NA NA NA 0.101 +/-0.0582 Uranium-234 NA NA NA NA NA 1.06 +/-0.203 Uranium-235 NA NA NA NA NA 0.0667 +/-0.0508 Radiochem-Gamma Emitters Uranium-238 0.432 +/-0.243 0.360 U +/-0.520 0.227 U +/-0.314 0.343 U +/-0.374 0.131 U +/-0.520 NA Uranium-235
-0.0314000 U +/-0.0616
-0.23500 U +/-0.274 0.0139 U +/-0.0457 0.0612 U +/-0.148
-0.14500 U +/-0.463 NA Radiochem-Gamma Emitters-TICs Actinium-228 0.475 +/-0.114 0.542 +/-0.188 0.490 +/-0.153 0.607 +/-0.174 0.722 +/-0.158 NA Bismuth-212 NA NA NA NA NA NA Bismuth-214 0.251 +/-0.0920 NA 0.287 +/-0.0898 0.281 +/-0.116 0.490 +/-0.129 NA Lead-210 NA NA NA NA NA NA Lead-212 0.329 +/-0.0742 0.515 +/-0.107 0.333 +/-0.0812 0.442 +/-0.101 0.512 +/-0.102 NA Lead-214 0.214 +/-0.0710 0.407 +/-0.122 0.341 +/-0.0956 0.300 +/-0.104 0.276 +/-0.0867 NA Potassium-40 5.14 +/-0.960 6.87 +/-1.34 6.21 +/-1.15 5.66 +/-1.22 7.29 +/-1.25 NA Thallium-208 0.150 +/-0.0359 0.150 +/-0.0630 0.183 +/-0.0536 0.185 +/-0.0628 0.231 +/-0.0759 NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 3/20
Table 2-3a Cleanup Plan Appendix A - Building Characterization Survey Radiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-PC-03 6HE-WS-03 6H-R-01 6H-RW-01 6HW-FS-01 6HW-FS-02 Date Collected:
12/19/18 12/20/18 12/21/18 12/21/18 12/21/18 12/21/18 Sample Name:
6HE-PC-03-1219 6HE-WS-03-1220 6H-R-01-1221 6H-RW-01-1221 6HW-FS-01-1221 6HW-FS-02-1221 Radiochem-Alpha Spectrometry Uranium-238 0.145 +/-0.0678 NA 0.658 +/-0.190 0.0654 +/-0.0453 NA NA Uranium-234 2.58 +/-0.350 NA 1.03 +/-0.244 0.0412 U +/-0.0372 NA NA Uranium-235 0.0609 +/-0.0483 NA 0.0420 U +/-0.0535
-0.004660000 U +/-0.00660 NA NA Radiochem-Gamma Emitters Uranium-238 NA 0.988 U +/-0.735 NA NA 0.275 U +/-0.460 0.369 U +/-0.401 Uranium-235 NA
-0.0218000 U +/-0.0389 NA NA 0 U +/-0.168 0.0522 U +/-0.129 Radiochem-Gamma Emitters-TICs Actinium-228 NA 1.43 +/-0.291 NA NA 0.421 +/-0.125 0.521 +/-0.175 Bismuth-212 NA NA NA NA NA NA Bismuth-214 NA 0.816 +/-0.223 NA NA 0.378 +/-0.112 0.329 +/-0.119 Lead-210 NA NA NA NA NA NA Lead-212 NA 1.32 +/-0.225 NA NA 0.344 +/-0.0872 0.354 +/-0.0979 Lead-214 NA 0.959 +/-0.212 NA NA 0.333 +/-0.101 NA Potassium-40 NA 21.2 +/-3.20 NA NA 6.22 +/-1.14 5.64 +/-1.20 Thallium-208 NA 0.470 +/-0.126 NA NA 0.168 +/-0.0622 0.143 +/-0.0710 Location ID:
6HW-FS-03 6HW-FS-04 6HW-FS-05 6HW-WALL-01 Date Collected:
12/21/18 12/21/18 12/21/18 12/21/18 Sample Name:
6HW-FS-03-1221 6HW-FS-04-1221 6HW-FS-05-1221 6HW-WALL-01-1221 Radiochem-Alpha Spectrometry Uranium-238 NA NA NA 0.109 +/-0.0684 Uranium-234 NA NA NA 0.144 +/-0.0765 Uranium-235 NA NA NA 0.00605 U +/-0.0257 Radiochem-Gamma Emitters Uranium-238
-0.17500 U +/-0.621 0.640 U +/-0.586
-0.25400 U +/-0.513 NA Uranium-235
-0.0298000 U +/-0.0549
-0.21500 U +/-0.292 0.0262 U +/-0.144 NA Radiochem-Gamma Emitters-TICs Actinium-228 0.404 +/-0.146 0.435 +/-0.214 NA NA Bismuth-212 0.918 +/-0.339 NA NA NA Bismuth-214 0.280 +/-0.0911 0.254 +/-0.101 0.307 +/-0.0970 NA Lead-210 NA NA NA NA Lead-212 0.377 +/-0.0780 0.426 +/-0.0932 0.336 +/-0.0796 NA Lead-214 0.210 +/-0.0654 0.422 +/-0.105 0.284 +/-0.0709 NA Potassium-40 6.02 +/-1.06 5.94 +/-1.19 5.25 +/-1.03 NA Thallium-208 0.137 +/-0.0471 0.105 +/-0.0457 NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 4/20
Table 2-3a Cleanup Plan Appendix A - Building Characterization Survey Radiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Notes:
- 1. All samples were collected by Arcadis on the dates indicated and submitted to Test America Laboratories for analysis.
- 2. Sample analysis was conducted using the following Methods:
Isotopic Uranium (Alpha Spectrometry): Method A-01-R Cesium-137 & Other Gamma Emmitters (GS): Method GA-01-R
- 3. NA = Constituent was not analyzed.
- 4. ND = Analyte not detected at a concentration greater than the Practical Quantitation Limit (PQL). PQL denotes lowest reportable analyte concentration.
- 5. Units: pCi/g = average picocuries per gram
- 6. Sample ID Nomenclature: BUILDING - (FLOOR) - MEDIA - NUMBER (##) - DATE (MMYY)
- 7. Laboratory Qualifiers:
U Result is less than the sample detection limit.
G The Sample Method Detectable Concentration is greater than the requested Reporting Limit.
Building IDs:
Media IDs (where applicable):
3H: Building 3H FB: Floor/Biased 6H: Building 6H FS: Floor/Systematic 6HE: Building 6H - Eastside F-WC: Floor/Waste Characterization 6HW: Building 6H - Westside WB: Wall/Biased WS: Wall/Systematic W-WC: Wall/Waste Characterization WALL: Wall PC: Paint Chip CG: Caulk R: Roof RW: Roof/Wood C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 5/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-CG-03 3H-CG-04 3H-FB-07 3H-FB-0506 (FD-01) 3H-FS-02 3H-FS-11 3H-F-WC-01 3H-PC-01 Date Collected:
12/20/18 12/21/18 12/20/18 12/19/18 12/19/2018 (12/21/2018) 12/20/18 12/17/18 12/21/18 12/20/18 Sample Name:
3H-CG-02-1220 3H-CG-03-1221 3H-CG-04-1220 3H-FB-07-1217 3H-FB-0506-1219 (FD-01) 3H-FS-02-1217 3H-FS-11-1217 3H-F-WC-01-1221 3H-PC-01-1220 PCBs Aroclor 1016 0.66 U 2.1 U 28 U 0.59 U 0.24 U 1.2 U 0.24 U 0.59 U 3.1 U Aroclor 1221 0.93 U 2.9 U 40 U 0.84 U 0.34 U 1.7 U 0.34 U 0.84 U 4.4 U Aroclor 1232 0.66 U 2.1 U 28 U 0.59 U 0.24 U 1.2 U 0.24 U 0.59 U 3.1 U Aroclor 1242 0.66 U 2.1 U 28 U 0.59 U 0.24 U 1.2 U 0.24 U 0.59 U 3.1 U Aroclor 1248 0.66 U 2.1 U 28 U 2.4 0.24 U 1.2 U 0.24 U 0.59 U 3.1 U Aroclor 1254 3.3 5
140 0.59 U 0.24 U 6.9 1.6 3.4 14 Aroclor 1260 0.66 U 2.1 U 28 U 0.59 U 0.24 U 1.2 U 0.24 U 0.59 U 3.1 U Aroclor 1262 0.66 U 2.1 U 28 U 0.59 U 0.65 1.2 U 0.24 U 0.59 U 3.1 U Aroclor 1268 0.66 U 2.1 U 28 U 0.59 U 0.24 U 1.2 U 0.24 U 0.59 U 3.1 U Total PCBs 3.3 5
140 2.4 0.65 6.9 1.6 3.4 14 Volatile Organics 1,1,1-Trichloroethane NA NA NA NA NA 0.0049 U NA NA NA 1,1,2,2-Tetrachloroethane NA NA NA NA NA 0.0049 U NA NA NA 1,1,2-trichloro-1,2,2-trifluoroethane NA NA NA NA NA 0.02 U NA NA NA 1,1,2-Trichloroethane NA NA NA NA NA 0.0049 U NA NA NA 1,1-Dichloroethane NA NA NA NA NA 0.0049 U NA NA NA 1,1-Dichloroethene NA NA NA NA NA 0.0049 U NA NA NA 1,2,3-Trichlorobenzene NA NA NA NA NA 0.0049 U NA NA NA 1,2,4-Trichlorobenzene NA NA NA NA NA 0.0049 U NA NA NA 1,2-Dibromo-3-chloropropane NA NA NA NA NA 0.0099 U NA NA NA 1,2-Dibromoethane NA NA NA NA NA 0.0049 U NA NA NA 1,2-Dichlorobenzene NA NA NA NA NA 0.0049 U NA NA NA 1,2-Dichloroethane NA NA NA NA NA 0.0049 U NA NA NA 1,2-Dichloropropane NA NA NA NA NA 0.0049 U NA NA NA 1,3-Dichlorobenzene NA NA NA NA NA 0.0049 U NA NA NA 1,4-Dichlorobenzene NA NA NA NA NA 0.0049 U NA NA NA 1,4-Dioxane NA NA NA NA NA 0.49 U NA NA NA 2-Butanone (MEK)
NA NA NA NA NA 0.02 U NA NA NA 4-Methyl-2-Pentanone NA NA NA NA NA 0.02 U NA NA NA Acetone NA NA NA NA NA 0.03 NA NA NA Bromochloromethane NA NA NA NA NA 0.0049 U NA NA NA Bromodichloromethane NA NA NA NA NA 0.0049 U NA NA NA Bromoform NA NA NA NA NA 0.0049 U NA NA NA Bromomethane NA NA NA NA NA 0.0099 U NA NA NA Carbon Disulfide NA NA NA NA NA 0.0049 U NA NA NA Carbon Tetrachloride NA NA NA NA NA 0.0049 U NA NA NA CFC-11 NA NA NA NA NA 0.0099 U NA NA NA CFC-12 NA NA NA NA NA 0.0099 U NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 6/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-CG-03 3H-CG-04 3H-FB-07 3H-FB-0506 (FD-01) 3H-FS-02 3H-FS-11 3H-F-WC-01 3H-PC-01 Date Collected:
12/20/18 12/21/18 12/20/18 12/19/18 12/19/2018 (12/21/2018) 12/20/18 12/17/18 12/21/18 12/20/18 Sample Name:
3H-CG-02-1220 3H-CG-03-1221 3H-CG-04-1220 3H-FB-07-1217 3H-FB-0506-1219 (FD-01) 3H-FS-02-1217 3H-FS-11-1217 3H-F-WC-01-1221 3H-PC-01-1220 Chlorobenzene NA NA NA NA NA 0.0049 U NA NA NA Chlorodibromomethane NA NA NA NA NA 0.0049 U NA NA NA Chloroethane NA NA NA NA NA 0.0099 U NA NA NA Chloroform NA NA NA NA NA 0.0099 U NA NA NA Chloromethane NA NA NA NA NA 0.0099 U NA NA NA cis-1,2-Dichloroethene NA NA NA NA NA 0.0025 U NA NA NA cis-1,3-Dichloropropene NA NA NA NA NA 0.0049 U NA NA NA Cyclohexane NA NA NA NA NA 0.0049 U NA NA NA Dichloromethane NA NA NA NA NA 0.0049 U NA NA NA Isopropylbenzene NA NA NA NA NA 0.0049 U NA NA NA m,p-Xylene NA NA NA NA NA 0.0012 J NA NA NA Methyl Acetate NA NA NA NA NA 0.0099 U NA NA NA Methyl N-Butyl Ketone (2-Hexanone)
NA NA NA NA NA 0.02 U NA NA NA Methylcyclohexane NA NA NA NA NA 0.0049 U NA NA NA o-Xylene NA NA NA NA NA 0.00083 J NA NA NA Styrene (Monomer)
NA NA NA NA NA 0.0049 U NA NA NA Tetrachloroethene NA NA NA NA NA 0.0049 U NA NA NA trans-1,2-Dichloroethene NA NA NA NA NA 0.0025 U NA NA NA trans-1,3-Dichloropropene NA NA NA NA NA 0.0049 U NA NA NA Trichloroethene NA NA NA NA NA 0.0004 J NA NA NA Vinyl chloride NA NA NA NA NA 0.0049 U NA NA NA Benzene NA NA NA NA NA 0.0049 U NA NA NA Toluene NA NA NA NA NA 0.0049 U NA NA NA Ethylbenzene NA NA NA NA NA 0.0049 U NA NA NA Methyl-tert-butylether NA NA NA NA NA 0.02 U NA NA NA Semivolatile Organics 1,1-Biphenyl NA NA NA NA NA 0.31 U NA NA NA 1,2,4,5-Tetrachlorobenzene NA NA NA NA NA 0.31 U NA NA NA 1,2,4-Trichlorobenzene NA NA NA NA NA 0.31 U NA NA NA 1,2-Dichlorobenzene NA NA NA NA NA 0.31 U NA NA NA 1,2-Diphenylhydrazine NA NA NA NA NA 0.31 U NA NA NA 1,3-Dichlorobenzene NA NA NA NA NA 0.31 U NA NA NA 1,3-Dinitrobenzene NA NA NA NA NA 0.31 U NA NA NA 1,4-Dichlorobenzene NA NA NA NA NA 0.31 U NA NA NA 1,4-Dioxane NA NA NA NA NA 0.61 U NA NA NA 1-Methylnaphthalene NA NA NA NA NA 0.31 U NA NA NA 2,2-Oxybis(1-Chloropropane)
NA NA NA NA NA 0.31 U NA NA NA 2,3,4,6-Tetrachlorophenol NA NA NA NA NA 1.5 U NA NA NA 2,4,5-Trichlorophenol NA NA NA NA NA 0.31 U NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 7/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-CG-03 3H-CG-04 3H-FB-07 3H-FB-0506 (FD-01) 3H-FS-02 3H-FS-11 3H-F-WC-01 3H-PC-01 Date Collected:
12/20/18 12/21/18 12/20/18 12/19/18 12/19/2018 (12/21/2018) 12/20/18 12/17/18 12/21/18 12/20/18 Sample Name:
3H-CG-02-1220 3H-CG-03-1221 3H-CG-04-1220 3H-FB-07-1217 3H-FB-0506-1219 (FD-01) 3H-FS-02-1217 3H-FS-11-1217 3H-F-WC-01-1221 3H-PC-01-1220 2,4,6-Trichlorophenol NA NA NA NA NA 0.31 U NA NA NA 2,4-Dichlorophenol NA NA NA NA NA 0.31 U NA NA NA 2,4-Dimethylphenol NA NA NA NA NA 0.31 U NA NA NA 2,4-Dinitrophenol NA NA NA NA NA 1.5 U NA NA NA 2,4-Dinitrotoluene NA NA NA NA NA 0.31 U NA NA NA 2,6-Dichlorophenol NA NA NA NA NA 0.31 U NA NA NA 2,6-Dinitrotoluene NA NA NA NA NA 0.31 U NA NA NA 2-Chloronaphthalene NA NA NA NA NA 0.31 U NA NA NA 2-Chlorophenol NA NA NA NA NA 0.31 U NA NA NA 2-Methyl-4,6-dinitrophenol NA NA NA NA NA 1.5 U NA NA NA 2-Methylnaphthalene NA NA NA NA NA 0.31 U NA NA NA 2-Methylphenol NA NA NA NA NA 0.31 U NA NA NA 2-Nitroaniline NA NA NA NA NA 1.5 U NA NA NA 2-Nitrophenol NA NA NA NA NA 0.31 U NA NA NA 3,3-Dichlorobenzidine NA NA NA NA NA 0.61 U NA NA NA 3-Methylphenol NA NA NA NA NA 0.31 U NA NA NA 3-Nitroaniline NA NA NA NA NA 1.5 U NA NA NA 4-Bromophenyl phenyl ether NA NA NA NA NA 0.31 U NA NA NA 4-Chloro-3-Methylphenol NA NA NA NA NA 0.31 U NA NA NA 4-Chlorophenyl phenyl ether NA NA NA NA NA 0.31 U NA NA NA 4-Methylphenol NA NA NA NA NA 0.31 U NA NA NA 4-Nitroaniline NA NA NA NA NA 1.5 U NA NA NA 4-Nitrophenol NA NA NA NA NA 1.5 U NA NA NA Acenaphthene NA NA NA NA NA 0.31 U NA NA NA Acenaphthylene NA NA NA NA NA 0.31 U NA NA NA Acetophenone NA NA NA NA NA 0.31 U NA NA NA Aniline NA NA NA NA NA 0.31 U NA NA NA Anthracene NA NA NA NA NA 0.31 U NA NA NA Azobenzene NA NA NA NA NA 0.31 U NA NA NA Benzaldehyde NA NA NA NA NA 0.31 U NA NA NA Benzidine NA NA NA NA NA 3.1 U NA NA NA Benzo(a)anthracene NA NA NA NA NA 0.31 U NA NA NA Benzo(a)pyrene NA NA NA NA NA 0.31 U NA NA NA Benzo(b)fluoranthene NA NA NA NA NA 0.31 U NA NA NA Benzo(g,h,i)perylene NA NA NA NA NA 0.31 U NA NA NA Benzo(k)fluoranthene NA NA NA NA NA 0.31 U NA NA NA Benzoic Acid NA NA NA NA NA 1.5 U NA NA NA Benzyl Alcohol NA NA NA NA NA 0.31 U NA NA NA bis(2-Chloroethoxy)methane NA NA NA NA NA 0.31 U NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 8/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-CG-03 3H-CG-04 3H-FB-07 3H-FB-0506 (FD-01) 3H-FS-02 3H-FS-11 3H-F-WC-01 3H-PC-01 Date Collected:
12/20/18 12/21/18 12/20/18 12/19/18 12/19/2018 (12/21/2018) 12/20/18 12/17/18 12/21/18 12/20/18 Sample Name:
3H-CG-02-1220 3H-CG-03-1221 3H-CG-04-1220 3H-FB-07-1217 3H-FB-0506-1219 (FD-01) 3H-FS-02-1217 3H-FS-11-1217 3H-F-WC-01-1221 3H-PC-01-1220 bis(2-Chloroethyl)ether NA NA NA NA NA 0.31 U NA NA NA bis(2-Ethylhexyl)phthalate NA NA NA NA NA 0.15 J NA NA NA Butyl benzyl phthalate NA NA NA NA NA 0.31 U NA NA NA Caprolactam NA NA NA NA NA 0.31 U NA NA NA Carbazole NA NA NA NA NA 0.31 U NA NA NA Chrysene NA NA NA NA NA 0.31 U NA NA NA Dibenzo(a,h)anthracene NA NA NA NA NA 0.31 U NA NA NA Dibenzofuran NA NA NA NA NA 0.31 U NA NA NA Diethyl phthalate NA NA NA NA NA 0.61 U NA NA NA Dimethyl phthalate NA NA NA NA NA 0.31 U NA NA NA Di-n-butyl phthalate NA NA NA NA NA 0.31 U NA NA NA Di-n-octyl phthalate NA NA NA NA NA 0.31 U NA NA NA Diphenylamine NA NA NA NA NA 0.31 U NA NA NA Famphur NA NA NA NA NA 0.61 U NA NA NA Fluoranthene NA NA NA NA NA 0.058 J NA NA NA Fluorene NA NA NA NA NA 0.31 U NA NA NA Hexachloro-1,3-butadiene NA NA NA NA NA 0.31 U NA NA NA Hexachlorobenzene NA NA NA NA NA 0.31 U NA NA NA Hexachlorocyclopentadiene NA NA NA NA NA 1.5 U NA NA NA Hexachloroethane NA NA NA NA NA 0.31 U NA NA NA Indeno(1,2,3-cd)pyrene NA NA NA NA NA 0.31 U NA NA NA Isophorone NA NA NA NA NA 0.31 U NA NA NA Naphthalene NA NA NA NA NA 0.31 U NA NA NA n-Hexadecane NA NA NA NA NA 0.048 J NA NA NA Nitrobenzene NA NA NA NA NA 0.31 U NA NA NA N-Nitrosodimethylamine NA NA NA NA NA 0.31 U NA NA NA n-Nitrosodi-n-propylamine NA NA NA NA NA 0.31 U NA NA NA N-nitrosodiphenylamine NA NA NA NA NA 0.31 U NA NA NA p-Chloroaniline NA NA NA NA NA 0.31 U NA NA NA Pentachlorophenol NA NA NA NA NA 1.5 U NA NA NA Phenanthrene NA NA NA NA NA 0.028 J NA NA NA Phenol NA NA NA NA NA 0.31 U NA NA NA Pyrene NA NA NA NA NA 0.042 J NA NA NA Pyridine NA NA NA NA NA 0.61 U NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 9/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-CG-03 3H-CG-04 3H-FB-07 3H-FB-0506 (FD-01) 3H-FS-02 3H-FS-11 3H-F-WC-01 3H-PC-01 Date Collected:
12/20/18 12/21/18 12/20/18 12/19/18 12/19/2018 (12/21/2018) 12/20/18 12/17/18 12/21/18 12/20/18 Sample Name:
3H-CG-02-1220 3H-CG-03-1221 3H-CG-04-1220 3H-FB-07-1217 3H-FB-0506-1219 (FD-01) 3H-FS-02-1217 3H-FS-11-1217 3H-F-WC-01-1221 3H-PC-01-1220 Inorganics Arsenic NA NA NA 1.7 J 1.6 J 1.6 J 1.9 3.1 39 J Barium NA NA NA 40 41 42 54 56 290 J Cadmium NA NA NA 0.91 U 0.84 U 0.84 U 0.94 U 0.87 J 49 U Chromium NA NA NA 12 13 21 16 28 1,800 Lead NA NA NA 11 5.0 2.9 2.7 13 57,000 Mercury NA NA NA 0.028 J 0.017 J 0.030 J 0.039 U 0.020 J 18 Selenium NA NA NA 2.7 U 2.5 U 2.5 U 2.8 U 2.7 U 150 U Silver NA NA NA 1.8 U 1.7 U 1.7 U 1.9 U 1.8 U 97 U Inorganics-TCLP Arsenic NA NA NA 0.50 U 0.50 U [0.50 U]
NA 0.50 U NA NA Barium NA NA NA 0.28 J 0.23 J [0.24 J]
NA 0.41 J NA NA Cadmium NA NA NA 0.10 U 0.10 U [0.0021 J]
NA 0.10 U NA NA Chromium NA NA NA 0.039 J 0.034 J [0.041 J]
NA 0.092 J NA NA Lead NA NA NA 0.50 U 0.50 U [0.50 U]
NA 0.50 U NA NA Mercury NA NA NA 0.0020 U 0.0020 U [0.0020 U]
NA 0.0020 U NA NA Selenium NA NA NA 0.10 U 0.10 U [0.10 U]
NA 0.10 U NA NA Silver NA NA NA 0.50 U 0.50 U [0.50 U]
NA 0.50 U NA NA VOCs-TCLP 1,1-Dichloroethene NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA 1,2-Dichloroethane NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA 2-Butanone (MEK)
NA NA NA 0.10 U 0.10 U NA 0.10 U NA NA Carbon Tetrachloride NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA Chlorobenzene NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA Chloroform NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA Tetrachloroethene NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA Trichloroethene NA NA NA 0.010 U 0.010 U NA 0.010 UF1 NA NA Vinyl chloride NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA Benzene NA NA NA 0.010 U 0.010 U NA 0.010 U NA NA SVOCs-TCLP 1,4-Dichlorobenzene NA NA NA 0.020 U 0.020 U NA 0.020 U NA NA 2,4,5-Trichlorophenol NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA 2,4,6-Trichlorophenol NA NA NA 0.025 U 0.025 U NA 0.025 U NA NA 2,4-Dinitrotoluene NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA 2-Methylphenol NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA 4-Methylphenol NA NA NA 0.0034 J 0.0016 J NA 0.016 J NA NA Hexachloro-1,3-butadiene NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA Hexachlorobenzene NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 10/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-CG-02 3H-CG-03 3H-CG-04 3H-FB-07 3H-FB-0506 (FD-01) 3H-FS-02 3H-FS-11 3H-F-WC-01 3H-PC-01 Date Collected:
12/20/18 12/21/18 12/20/18 12/19/18 12/19/2018 (12/21/2018) 12/20/18 12/17/18 12/21/18 12/20/18 Sample Name:
3H-CG-02-1220 3H-CG-03-1221 3H-CG-04-1220 3H-FB-07-1217 3H-FB-0506-1219 (FD-01) 3H-FS-02-1217 3H-FS-11-1217 3H-F-WC-01-1221 3H-PC-01-1220 Hexachloroethane NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA Nitrobenzene NA NA NA 0.050 U 0.050 U NA 0.050 U NA NA Pentachlorophenol NA NA NA 0.25 U 0.25 U NA 0.25 U NA NA Pyridine NA NA NA 0.10 U 0.10 U NA 0.10 U NA NA PCBs-TCLP Aroclor 1016 NA NA NA 0.01 U 0.01 U [0.01 UF1]
NA 0.01 U NA NA Aroclor 1221 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.01 U NA NA Aroclor 1232 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.01 U NA NA Aroclor 1242 NA NA NA 0.01 U 0.01 U [0.018]
NA 0.01 U NA NA Aroclor 1248 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.0069 Jp NA NA Aroclor 1254 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.01 U NA NA Aroclor 1260 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.01 U NA NA Aroclor 1262 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.01 U NA NA Aroclor 1268 NA NA NA 0.01 U 0.01 U [0.01 U]
NA 0.01 U NA NA Total PCBs NA NA NA 0.01 U 0.01 U [0.018]
NA 0.0069 Jp NA NA Location ID:
3H-PC-02 3H-R-01 3H-R-02 3H-WS-03 3H-WS-04 3H-WS-07 3H-WS-10 3H-W-WC-01 6HE-CG-01 Date Collected:
12/19/18 12/20/18 12/20/18 12/19/18 12/20/18 12/20/18 12/19/18 12/21/18 12/20/18 Sample Name:
3H-PC-02-1220 3H-R-01-1220 3H-R-02-1220 3H-WS-03-1217 3H-WS-04-1220 3H-WS-07-1220 3H-WS-10-1217 3H-W-WC-01-1221 6HE-CG-01-1220 PCBs Aroclor 1016 NA 0.16 U 0.061 U 0.65 U 0.06 U 0.06 UF2 0.065 UF1 0.24 U 1.3 U Aroclor 1221 NA 0.22 U 0.087 U 0.93 U 0.085 U 0.086 U 0.092 U 0.35 U 1.8 U Aroclor 1232 NA 0.16 U 0.061 U 0.65 U 0.06 U 0.06 U 0.065 U 0.24 U 1.3 U Aroclor 1242 NA 0.16 U 0.061 U 0.65 U 0.06 U 0.06 U 0.065 U 0.24 U 1.3 U Aroclor 1248 NA 0.29 0.061 U 0.65 U 0.06 U 0.06 U 0.065 U 0.24 U 1.3 U Aroclor 1254 NA 0.16 U 0.061 U 0.86 0.092 0.068 0.21 1.5 5
Aroclor 1260 NA 0.16 U 0.061 U 0.65 U 0.06 U 0.06 UF2 0.065 UF1 0.24 U 1.3 U Aroclor 1262 NA 0.16 U 0.061 U 0.65 U 0.06 U 0.06 U 0.065 U 0.24 U 1.3 U Aroclor 1268 NA 0.16 U 0.061 U 0.65 U 0.06 U 0.06 U 0.065 U 0.24 U 1.3 U Total PCBs NA 0.29 0.061 U 0.86 0.092 0.068 0.21 1.5 5
Inorganics Arsenic NA NA 460 0.87 J 2.1 22 2.2 NA NA Barium NA NA 6.0 J 120 46 7,300 54 NA NA Cadmium NA NA 2.3 U 0.48 U 0.14 J 3.0 J 0.23 J NA NA Chromium NA NA 1,400 19 6.9 31 6.8 NA NA Lead NA NA 5.8 16 11 780 10 NA NA Mercury NA NA 0.074 0.15 0.069 0.28 0.023 J NA NA Selenium NA NA 1.2 J 1.5 U 1.3 U 26 U 1.3 U NA NA Silver NA NA 1.9 U 0.97 U 0.90 U 18 U 0.86 U NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 11/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-PC-02 3H-R-01 3H-R-02 3H-WS-03 3H-WS-04 3H-WS-07 3H-WS-10 3H-W-WC-01 6HE-CG-01 Date Collected:
12/19/18 12/20/18 12/20/18 12/19/18 12/20/18 12/20/18 12/19/18 12/21/18 12/20/18 Sample Name:
3H-PC-02-1220 3H-R-01-1220 3H-R-02-1220 3H-WS-03-1217 3H-WS-04-1220 3H-WS-07-1220 3H-WS-10-1217 3H-W-WC-01-1221 6HE-CG-01-1220 Inorganics-TCLP Arsenic 0.50 U NA 0.46 J NA NA 0.50 U 0.50 U NA NA Barium 0.026 JB NA 0.092 JB NA NA 0.38 JB 0.22 JB NA NA Cadmium 0.22 NA 0.10 U NA NA 0.0020 J 0.10 U NA NA Chromium 0.022 J NA 0.87 NA NA 0.013 J 0.0046 J NA NA Lead 220 NA 0.50 U NA NA 0.014 J 0.50 U NA NA Mercury 0.0017 J NA 0.0020 U NA NA 0.0020 U 0.0020 U NA NA Selenium 0.10 U NA 0.10 U NA NA 0.10 U 0.10 U NA NA Silver 0.50 U NA 0.50 U NA NA 0.50 U 0.50 U NA NA VOCs-TCLP 1,1-Dichloroethene 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA 1,2-Dichloroethane 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA 2-Butanone (MEK) 0.10 U NA 0.10 U NA NA 0.10 U 0.10 U NA NA Carbon Tetrachloride 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA Chlorobenzene 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA Chloroform 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA Tetrachloroethene 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA Trichloroethene 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA Vinyl chloride 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA Benzene 0.010 U NA 0.010 U NA NA 0.010 U 0.010 U NA NA SVOCs-TCLP 1,4-Dichlorobenzene 0.020 U NA 0.020 U NA NA 0.020 U 0.020 U NA NA 2,4,5-Trichlorophenol 0.050 U NA 0.050 U NA NA 0.050 UF1 0.050 U NA NA 2,4,6-Trichlorophenol 0.025 U NA 0.025 U NA NA 0.025 UF1 0.025 U NA NA 2,4-Dinitrotoluene 0.050 U NA 0.050 U NA NA 0.050 U 0.050 U NA NA 2-Methylphenol 0.050 U NA 0.050 U NA NA 0.050 UF1F2 0.050 U NA NA 4-Methylphenol 0.050 U NA 0.0060 J NA NA 0.050 UF1F2 0.050 U NA NA Hexachloro-1,3-butadiene 0.050 U NA 0.050 U NA NA 0.050 U 0.050 U NA NA Hexachlorobenzene 0.050 U NA 0.050 U NA NA 0.050 U 0.050 U NA NA Hexachloroethane 0.050 U NA 0.050 U NA NA 0.050 U 0.050 U NA NA Nitrobenzene 0.050 U NA 0.050 U NA NA 0.050 U 0.050 U NA NA Pentachlorophenol 0.25 U NA 0.25 U NA NA 0.25 UF1 0.25 U NA NA Pyridine 0.10 U NA 0.10 U NA NA 0.10 U 0.10 U NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 12/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
3H-PC-02 3H-R-01 3H-R-02 3H-WS-03 3H-WS-04 3H-WS-07 3H-WS-10 3H-W-WC-01 6HE-CG-01 Date Collected:
12/19/18 12/20/18 12/20/18 12/19/18 12/20/18 12/20/18 12/19/18 12/21/18 12/20/18 Sample Name:
3H-PC-02-1220 3H-R-01-1220 3H-R-02-1220 3H-WS-03-1217 3H-WS-04-1220 3H-WS-07-1220 3H-WS-10-1217 3H-W-WC-01-1221 6HE-CG-01-1220 PCBs-TCLP Aroclor 1016 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1221 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1232 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1242 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1248 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1254 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1260 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1262 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Aroclor 1268 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Total PCBs 0.01 U NA 0.01 U NA NA 0.01 U 0.01 U NA NA Location ID:
6HE-CG-02 6HE-FS-05 6HE-FS-07 6HE-PC-01 6HE-PC-02 6HE-PC-03 6HE-WS-01 6HE-WS-02 6HE-WS-05 Date Collected:
12/20/18 12/19/18 12/20/18 12/19/18 12/19/18 12/19/18 12/21/18 12/20/18 12/20/18 Sample Name:
6HE-CG-02-1220 6HE-FS-05-1219 6HE-FS-07-1220 6HE-PC-01-1219 6HE-PC-02-1219 6HE-PC-03-1219 6HE-WS-01-1221 6HE-WS-02-1220 6HE-WS-05-1220 PCBs Aroclor 1016 0.15 U 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Aroclor 1221 0.22 U 0.35 U 0.084 U 4.4 U 4.7 U 2.3 U 0.084 U 0.085 U 0.33 U Aroclor 1232 0.15 U 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Aroclor 1242 0.15 U 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Aroclor 1248 0.26 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Aroclor 1254 0.15 U 1.1 0.26 16 17 6.4 0.16 0.011 Jp 0.81 Aroclor 1260 0.15 U 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Aroclor 1262 0.15 U 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Aroclor 1268 0.15 U 0.25 U 0.059 U 3.1 U 3.3 U 1.6 U 0.059 U 0.06 U 0.23 U Total PCBs 0.26 1.1 0.26 16 17 6.4 0.16 0.011 Jp 0.81 Inorganics Arsenic NA 1.6 J 1.6 J 98 U NA NA NA NA NA Barium NA 44 46 490 U NA NA NA NA NA Cadmium NA 0.91 U 0.94 U 49 NA NA NA NA NA Chromium NA 16 15 470 NA NA NA NA NA Lead NA 2.3 17 68,000 NA NA NA NA NA Mercury NA 0.019 J 0.024 J 12 NA NA NA NA NA Selenium NA 2.7 U 2.8 U 150 U NA NA NA NA NA Silver NA 1.8 U 1.9 U 98 U NA NA NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 13/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-CG-02 6HE-FS-05 6HE-FS-07 6HE-PC-01 6HE-PC-02 6HE-PC-03 6HE-WS-01 6HE-WS-02 6HE-WS-05 Date Collected:
12/20/18 12/19/18 12/20/18 12/19/18 12/19/18 12/19/18 12/21/18 12/20/18 12/20/18 Sample Name:
6HE-CG-02-1220 6HE-FS-05-1219 6HE-FS-07-1220 6HE-PC-01-1219 6HE-PC-02-1219 6HE-PC-03-1219 6HE-WS-01-1221 6HE-WS-02-1220 6HE-WS-05-1220 Inorganics-TCLP Arsenic NA 0.50 U 0.50 U NA NA NA NA NA NA Barium NA 0.30 J 0.23 J NA NA NA NA NA NA Cadmium NA 0.10 U 0.10 U NA NA NA NA NA NA Chromium NA 0.0081 J 0.064 J NA NA NA NA NA NA Lead NA 0.50 U 0.50 U NA NA NA NA NA NA Mercury NA 0.0020 U 0.0020 U NA NA NA NA NA NA Selenium NA 0.10 U 0.10 U NA NA NA NA NA NA Silver NA 0.50 U 0.50 U NA NA NA NA NA NA VOCs-TCLP 1,1-Dichloroethene NA 0.010 U 0.010 U NA NA NA NA NA NA 1,2-Dichloroethane NA 0.010 U 0.010 U NA NA NA NA NA NA 2-Butanone (MEK)
NA 0.10 U 0.10 U NA NA NA NA NA NA Carbon Tetrachloride NA 0.010 U 0.010 U NA NA NA NA NA NA Chlorobenzene NA 0.010 U 0.010 U NA NA NA NA NA NA Chloroform NA 0.010 U 0.010 U NA NA NA NA NA NA Tetrachloroethene NA 0.010 U 0.010 U NA NA NA NA NA NA Trichloroethene NA 0.010 U 0.010 U NA NA NA NA NA NA Vinyl chloride NA 0.010 U 0.010 U NA NA NA NA NA NA Benzene NA 0.010 U 0.010 U NA NA NA NA NA NA SVOCs-TCLP 1,4-Dichlorobenzene NA 0.020 U 0.020 U NA NA NA NA NA NA 2,4,5-Trichlorophenol NA 0.050 U 0.050 U NA NA NA NA NA NA 2,4,6-Trichlorophenol NA 0.025 U 0.025 U NA NA NA NA NA NA 2,4-Dinitrotoluene NA 0.050 U 0.050 U NA NA NA NA NA NA 2-Methylphenol NA 0.050 U 0.050 U NA NA NA NA NA NA 4-Methylphenol NA 0.050 U 0.050 U NA NA NA NA NA NA Hexachloro-1,3-butadiene NA 0.050 U 0.050 U NA NA NA NA NA NA Hexachlorobenzene NA 0.050 U 0.050 U NA NA NA NA NA NA Hexachloroethane NA 0.050 U 0.050 U NA NA NA NA NA NA Nitrobenzene NA 0.050 U 0.050 U NA NA NA NA NA NA Pentachlorophenol NA 0.25 U 0.25 U NA NA NA NA NA NA Pyridine NA 0.10 U 0.10 U NA NA NA NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 14/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-CG-02 6HE-FS-05 6HE-FS-07 6HE-PC-01 6HE-PC-02 6HE-PC-03 6HE-WS-01 6HE-WS-02 6HE-WS-05 Date Collected:
12/20/18 12/19/18 12/20/18 12/19/18 12/19/18 12/19/18 12/21/18 12/20/18 12/20/18 Sample Name:
6HE-CG-02-1220 6HE-FS-05-1219 6HE-FS-07-1220 6HE-PC-01-1219 6HE-PC-02-1219 6HE-PC-03-1219 6HE-WS-01-1221 6HE-WS-02-1220 6HE-WS-05-1220 PCBs-TCLP Aroclor 1016 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1221 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1232 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1242 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1248 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1254 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1260 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1262 NA 0.01 U 0.01 U NA NA NA NA NA NA Aroclor 1268 NA 0.01 U 0.01 U NA NA NA NA NA NA Total PCBs NA 0.01 U 0.01 U NA NA NA NA NA NA Location ID:
6HE-WS-06 6H-R-01 6H-RW-01 6HW-CG-01 6HW-FS-03 (6HW-FD-03) 6HW-FS-05 6HW-WALL-01 6HW-WS-01 6HW-WS-02 Date Collected:
12/20/18 12/21/18 12/21/18 12/20/18 12/21/2018 (12/21//2018) 12/21/18 12/21/18 12/21/18 12/21/18 Sample Name:
6HE-WS-06-1220 6H-R-01-1221 6H-RW-01-1221 6HW-CG-01-1220 6HW-FS-03-1221 (6HW-FD-03-1221) 6HW-FS-05-1221 6HW-WALL-01-1221 6HW-WS-01-1221 6HW-WS-02-1221 PCBs Aroclor 1016 0.059 U 1.6 U 0.26 U 0.3 U 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Aroclor 1221 0.084 U 2.2 U 0.37 U 0.43 U 0.34 U [1.8 U]
0.085 U 0.19 U 0.092 U 0.12 U Aroclor 1232 0.059 U 1.6 U 0.26 U 0.3 U 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Aroclor 1242 0.059 U 1.6 U 0.26 U 0.3 U 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Aroclor 1248 0.059 U 1.4 J 0.26 U 0.89 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Aroclor 1254 0.05 J 1.6 U 0.88 0.3 U 1.5 [7.7]
0.43 0.21 0.098 p 0.53 Aroclor 1260 0.059 U 1.6 U 0.26 U 0.3 U 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Aroclor 1262 0.059 U 1.6 U 0.26 U 0.3 U 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Aroclor 1268 0.059 U 1.6 U 0.26 U 0.3 U 0.24 U [1.3 U]
0.06 U 0.13 U 0.065 U 0.085 U Total PCBs 0.05 J 1.4 J 0.88 0.89 1.5 [7.7]
0.43 0.21 0.098 p 0.53 Inorganics Arsenic 3.9 0.96 U 340 NA 2.5 J [2.1]
1.7 4.5 U 2.8 3.9 Barium 1,200 13 24 U NA 41 [24]
19 11 J 280 940 Cadmium 0.90 U 0.48 U 2.4 U NA 0.94 U [0.48 U]
0.42 U 2.2 U 0.32 J 0.27 J Chromium 16 7.9 1,700 NA 18 [8.8]
6.8 1.4 J 13 29 Lead 62 75 21 NA 1.2 J [0.27 J]
0.41 J 1.7 J 73 270 Mercury 0.14 0.039 U 0.24 NA 0.064 [0.048]
0.057 0.23 0.14 0.22 Selenium 2.7 U 1.4 U 7.3 U NA 2.8 U [1.4 U]
1.3 U 6.7 U 2.8 U 1.4 U Silver 1.8 U 0.96 U 4.9 U NA 1.9 U [0.96 U]
0.84 U 4.5 U 1.9 U 0.95 U C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 15/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-WS-06 6H-R-01 6H-RW-01 6HW-CG-01 6HW-FS-03 (6HW-FD-03) 6HW-FS-05 6HW-WALL-01 6HW-WS-01 6HW-WS-02 Date Collected:
12/20/18 12/21/18 12/21/18 12/20/18 12/21/2018 (12/21//2018) 12/21/18 12/21/18 12/21/18 12/21/18 Sample Name:
6HE-WS-06-1220 6H-R-01-1221 6H-RW-01-1221 6HW-CG-01-1220 6HW-FS-03-1221 (6HW-FD-03-1221) 6HW-FS-05-1221 6HW-WALL-01-1221 6HW-WS-01-1221 6HW-WS-02-1221 Inorganics-TCLP Arsenic 0.50 U NA NA NA NA 0.50 U NA NA NA Barium 0.48 JB NA NA NA NA 0.29 J NA NA NA Cadmium 0.10 U NA NA NA NA 0.10 U NA NA NA Chromium 0.0080 J NA NA NA NA 0.020 J NA NA NA Lead 0.014 J NA NA NA NA 0.50 U NA NA NA Mercury 0.0020 U NA NA NA NA 0.0020 U NA NA NA Selenium 0.10 U NA NA NA NA 0.10 U NA NA NA Silver 0.50 U NA NA NA NA 0.50 U NA NA NA VOCs-TCLP 1,1-Dichloroethene 0.010 U NA NA NA NA 0.010 U NA NA NA 1,2-Dichloroethane 0.010 U NA NA NA NA 0.010 U NA NA NA 2-Butanone (MEK) 0.10 U NA NA NA NA 0.10 U NA NA NA Carbon Tetrachloride 0.010 U NA NA NA NA 0.010 U NA NA NA Chlorobenzene 0.010 U NA NA NA NA 0.010 U NA NA NA Chloroform 0.010 U NA NA NA NA 0.010 U NA NA NA Tetrachloroethene 0.010 U NA NA NA NA 0.010 U NA NA NA Trichloroethene 0.010 U NA NA NA NA 0.010 U NA NA NA Vinyl chloride 0.010 U NA NA NA NA 0.010 U NA NA NA Benzene 0.010 U NA NA NA NA 0.010 U NA NA NA SVOCs-TCLP 1,4-Dichlorobenzene 0.020 U NA NA NA NA 0.020 U NA NA NA 2,4,5-Trichlorophenol 0.050 U NA NA NA NA 0.050 U NA NA NA 2,4,6-Trichlorophenol 0.025 U NA NA NA NA 0.025 U NA NA NA 2,4-Dinitrotoluene 0.050 U NA NA NA NA 0.050 U NA NA NA 2-Methylphenol 0.050 U NA NA NA NA 0.050 U NA NA NA 4-Methylphenol 0.050 U NA NA NA NA 0.050 U NA NA NA Hexachloro-1,3-butadiene 0.050 U NA NA NA NA 0.050 U NA NA NA Hexachlorobenzene 0.050 U NA NA NA NA 0.050 U NA NA NA Hexachloroethane 0.050 U NA NA NA NA 0.050 U NA NA NA Nitrobenzene 0.050 U NA NA NA NA 0.050 U NA NA NA Pentachlorophenol 0.25 U NA NA NA NA 0.25 U NA NA NA Pyridine 0.10 U NA NA NA NA 0.10 U NA NA NA C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 16/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-WS-06 6H-R-01 6H-RW-01 6HW-CG-01 6HW-FS-03 (6HW-FD-03) 6HW-FS-05 6HW-WALL-01 6HW-WS-01 6HW-WS-02 Date Collected:
12/20/18 12/21/18 12/21/18 12/20/18 12/21/2018 (12/21//2018) 12/21/18 12/21/18 12/21/18 12/21/18 Sample Name:
6HE-WS-06-1220 6H-R-01-1221 6H-RW-01-1221 6HW-CG-01-1220 6HW-FS-03-1221 (6HW-FD-03-1221) 6HW-FS-05-1221 6HW-WALL-01-1221 6HW-WS-01-1221 6HW-WS-02-1221 PCBs-TCLP Aroclor 1016 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1221 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1232 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1242 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1248 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1254 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1260 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1262 0.01 U NA NA NA NA 0.01 U NA NA NA Aroclor 1268 0.01 U NA NA NA NA 0.01 U NA NA NA Total PCBs 0.01 U NA NA NA NA 0.01 U NA NA NA Location ID:
6HW-WS-03 (6HW-WD-03) 6HW-WS-04 6HW-WS-05 6HW-WS-06 Date Collected:
12/21/2018 (12/21/2018) 12/21/18 12/20/18 12/21/18 Sample Name:
6HW-WS-03-1221 (6HW-WD-03-1221) 6HW-WS-04-1221 6HW-WS-05-1220 6HW-WS-06-1221 PCBs Aroclor 1016 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Aroclor 1221 8.6 U [8.4 U]
0.09 U 0.094 U 0.089 U Aroclor 1232 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Aroclor 1242 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Aroclor 1248 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Aroclor 1254 25 [21]
0.099 p 0.52 0.03 Jp Aroclor 1260 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Aroclor 1262 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Aroclor 1268 6 U [5.9 U]
0.063 U 0.066 U 0.062 U Total PCBs 25 [21]
0.099 p 0.52 0.03 Jp Inorganics Arsenic 2.8 [2.8]
2.8 3.7 1.6 Barium 1,000 [320]
820 72 290 Cadmium 0.98 U [0.91 U]
0.31 J 0.97 U 0.50 U Chromium 11 [8.7]
14 19 5.2 Lead 64 [14]
59 71 150 Mercury 0.18 [0.095]
0.10 0.14 0.024 J Selenium 2.9 U [2.7 U]
1.5 U 2.9 U 1.5 U Silver 2.0 U [1.8 U]
0.98 U 1.9 U 1.0 U C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 17/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HW-WS-03 (6HW-WD-03) 6HW-WS-04 6HW-WS-05 6HW-WS-06 Date Collected:
12/21/2018 (12/21/2018) 12/21/18 12/20/18 12/21/18 Sample Name:
6HW-WS-03-1221 (6HW-WD-03-1221) 6HW-WS-04-1221 6HW-WS-05-1220 6HW-WS-06-1221 Inorganics-TCLP Arsenic 0.50 U [0.50 U]
0.50 U NA 0.50 U Barium 0.43 JB [0.43 JB]
0.22 JB NA 0.59 JB Cadmium 0.10 U [0.10 U]
0.10 U NA 0.10 U Chromium 0.017 J [0.027 J]
0.0076 J NA 0.015 J Lead 0.017 J [0.022 J]
0.50 U NA 3.1 Mercury 0.0020 U [0.0020 U]
0.0020 U NA 0.0020 U Selenium 0.10 U [0.10 U]
0.10 U NA 0.10 U Silver 0.50 U [0.50 U]
0.50 U NA 0.50 U VOCs-TCLP 1,1-Dichloroethene 0.010 U [0.010 U]
0.010 U NA 0.010 U 1,2-Dichloroethane 0.010 U [0.010 U]
0.010 U NA 0.010 U 2-Butanone (MEK) 0.10 U [0.10 U]
0.10 U NA 0.10 U Carbon Tetrachloride 0.010 U [0.010 U]
0.010 U NA 0.010 U Chlorobenzene 0.010 U [0.010 U]
0.010 U NA 0.010 U Chloroform 0.010 U [0.010 U]
0.010 U NA 0.010 U Tetrachloroethene 0.010 U [0.010 U]
0.010 U NA 0.010 U Trichloroethene 0.010 U [0.010 U]
0.010 U NA 0.010 U Vinyl chloride 0.010 U [0.010 U]
0.010 U NA 0.010 U Benzene 0.010 U [0.010 U]
0.010 U NA 0.010 U SVOCs-TCLP 1,4-Dichlorobenzene 0.020 U [0.020 U]
0.020 U NA 0.020 U 2,4,5-Trichlorophenol 0.050 U [0.050 U]
0.050 U NA 0.050 U 2,4,6-Trichlorophenol 0.025 U [0.025 U]
0.025 U NA 0.025 U 2,4-Dinitrotoluene 0.050 U [0.050 U]
0.050 U NA 0.050 U 2-Methylphenol 0.050 U [0.050 U]
0.050 U NA 0.050 U 4-Methylphenol 0.050 U [0.050 U]
0.050 U NA 0.050 U Hexachloro-1,3-butadiene 0.050 U [0.050 U]
0.050 U NA 0.050 U Hexachlorobenzene 0.050 U [0.050 U]
0.050 U NA 0.050 U Hexachloroethane 0.050 U [0.050 U]
0.050 U NA 0.050 U Nitrobenzene 0.050 U [0.050 U]
0.050 U NA 0.050 U Pentachlorophenol 0.25 U [0.25 U]
0.25 U NA 0.25 U Pyridine 0.10 U [0.10 U]
0.10 U NA 0.10 U C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 18/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HW-WS-03 (6HW-WD-03) 6HW-WS-04 6HW-WS-05 6HW-WS-06 Date Collected:
12/21/2018 (12/21/2018) 12/21/18 12/20/18 12/21/18 Sample Name:
6HW-WS-03-1221 (6HW-WD-03-1221) 6HW-WS-04-1221 6HW-WS-05-1220 6HW-WS-06-1221 PCBs-TCLP Aroclor 1016 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1221 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1232 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1242 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1248 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1254 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1260 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1262 0.01 U [0.01 U]
0.01 U NA 0.01 U Aroclor 1268 0.01 U [0.01 U]
0.01 U NA 0.01 U Total PCBs 0.01 U [0.01 U]
0.01 U NA 0.01 U C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 19/20
Table 2-3b Cleanup Plan Appendix A - Building Characterization Survey Nonradiological Characteristics General Electric Company - Former UNC Facility New Haven, Connecticut Notes:
- 1. All samples were collected by Arcadis on the dates indicated and submitted to Test America Laboratories for analysis.
- 2. Sample analysis was conducted using the following Methods:
Total VOCs: United States Environmental Protection Agency (USEPA) SW-846 Method 8260 Total SVOCs: USEPA SW-846 Method 8270 Total Inorganics: USEPA SW-846 Method 6010 PCBs: USEPA SW-846 Method 8082 Total Mercury: USEPA SW-846 Method 7470 TCLP VOCs: USEPA SW-846 Method 1311:Toxicity Characteristic Leaching Procedure and Method 8260 TCLP SVOCs: USEPA SW-846 Method 1311 and Method 8270 TCLP Inorganics:USEPA SW-846 Method 1311 and Method 6010 TCLP PCBs: USEPA SW-846 Method 1311 and Method 8082
- 3. NA = Constituent was not analyzed.
- 4. ND = Analyte not detected at a concentration greater than the Practical Quantitation Limit (PQL). PQL denotes lowest reportable analyte concentration.
- 5. Units: mg/kg = milligram per kilogram
- 6. [ ] = Duplicate sample results.
- 7. Laboratory Qualifiers:
B Denotes analyte observed in associated method blank. Analyte concentration should be considered as estimated.
F1 MS and/or MSD Recovery is outside acceptance limits.
F2 MS/MSD RPD exceeds control limits.
J Denotes an estimated concentration. The concentration result is greater than or equal to the Method Detection Limit (MDL) but less than the Practical Quantitation Limit (PQL).
p U
The compound was analyzed for but not detected. The associated value is the compound quantitation limit.
- 8. Sample ID Nomenclature: BUILDING - (FLOOR) - MEDIA - NUMBER (##) - DATE (MMYY)
Building IDs:
Media IDs (where applicable):
3H: Building 3H FB: Floor/Biased 6H: Building 6H FS: Floor/Systematic 6HE: Building 6H - Eastside F-WC: Floor/Waste Characterization 6HW: Building 6H - Westside WB: Wall/Biased WS: Wall/Systematic W-WC: Wall/Waste Characterization WALL: Wall PC: Paint Chip CG: Caulk R: Roof RW: Roof/Wood The Relative Percent Difference (%RPD) between the primary and confirmation column/detector is >40%. The lower value has been reported.
C:\\Users\\rgiampaolo\\Desktop\\UNC\\Addendum\\OneDrive_3_4-21-2020\\
Revised QCd - UNC Cleanup Plan_App A_BCS_Tables 20/20
APPENDIX B Site Background and Sampling Methodology and Results
APPENDIX B -
SITE BACKGROUND AND SAMPLING METHODOLOGY AND RESULTS
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx i
CONTENTS 1
Sampling Methodology.......................................................................................................................... 1 1.1 Survey Methods.............................................................................................................................. 1 1.2 Minimum Detectible Concentration................................................................................................. 1 1.3 Number of Sample Locations......................................................................................................... 2 2
Summary of Radiation Analytical Results............................................................................................. 2 2.1 Gamma Scan Results..................................................................................................................... 3 2.2 Alpha Scan Results........................................................................................................................ 3 2.3 Concrete Core samples.................................................................................................................. 4 2.4 Concrete Surface Contamination................................................................................................... 5 3
Summary of Non-Radiation Analytical Results..................................................................................... 6 4
References............................................................................................................................................ 6 TABLES Table B1. Concrete Core Samples: Radiological Characteristics Table B2. Systematic Concrete Core Samples: Radiological Characteristics Table B3. Fixed and Removal Contamination Swipe Sample: Radiological Characteristics Table B4. Concrete Core Samples: Non-radiological Characteristics FIGURES Figure B1. Cabrera Figure 1-2 Building 3H/6H Accessible Areas Figure B2. Cabrera Figure 8-1 Gamma Walkover Survey Scan Areas Figure B3. Cabrera Figure 8-2 Gamma Walkover Survey Scan Areas Figure B4. Location of Slab Surface Contamination Measurements/Smears Figure B5. Cabrera Figure 8-5 Alpha-Beta Floor Scan Survey Results Figure B6. Cabrera Figure 8-6 Alpha-Beta Floor Scan Survey Results Figure B7. Slab Sample Layout
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx 1
1 SAMPLING METHODOLOGY Appendix B presents the methodology used to conform to the Nuclear Regulatory Commissions (NRCs) approach for release of solid materials. This includes radiological survey methodology, instrumentation used to conduct the current surveys, and minimum detectible concentrations of the instrumentation for the contaminants of concern, The basis for the number of samples sent for analysis for radiological and hazardous waste constituents is also presented.
The results of the current radiological and hazardous waste surveys and sample results are presented along with a discussion of the results of prior gamma walkover survey and alpha surface survey performed by Cabrera reported in their Supplemental Radiological Survey Report, March 2018 (Cabrera, 2018).
1.1 Survey Methods In December 2002, a memorandum was issued by NRC headquarters licensing divisions presenting the approach that should be used regarding controlled release of concrete from licensed facilities (NRC, 2002).
This memo was reaffirmed in the NRCs Consolidated Decommissioning Guidance -Decommissioning Process for Material Licensees. Vol 1 Revision 2, (NRC, 2006). The memorandum noted release of solid materials on a case-by-case basis using existing guidance with the following criteria:
A) Sites should assess surficial contamination of concrete based on process knowledge and verified by appropriate core samples to confirm that the concrete does not contain contamination beyond a depth that can be measured by the instrumentation used for the survey.
B) Survey instruments should be used that are appropriate for evaluating the radioactive contamination of interest and all accessible surfaces should be evaluated. The number of core samples and the method for determining the depth at which a survey instrument can measure below the surface of the concrete should be determined on a case-specific basis.
C) Disposition of concrete with surficial contamination should be evaluated using Guidelines for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of Licenses for Byproduct, Source, or Special Nuclear Material, dated April 1993, which is based on Fuel Cycle Policy and Guidance Directive 83-23. There is no upper limit on the amount of concrete with surficial contamination that can be released from a materials site if it meets criteria contained in the April 1993 guidance document.
D) Surveys for the clearance of concrete with surficial contamination should be conducted before the concrete floor or wall is broken up. If the concrete wall or floor has been broken up, then it is considered a volumetric source of contamination.
These methods will be used to evaluate the remaining portion of the Building 6H concrete slab, foundations, and underlying soils and other miscellaneous concrete materials.
1.2 Minimum Detectible Concentration All radiological measuring instruments (probes and ratemeter/scalers) were selected based upon detection sensitivity to provide technically defensible results to meet the objectives of the survey. The minimum detectable concentration (MDC) is an a priori statement of instruments sensitivity and depends upon the background counting rate, detector efficiency, and counting time.
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx 2
Gamma scanning surveys were performed using a Ludlum 44-10, 2-inch by 2-inch sodium iodide (NaI) detector coupled with a Ludlum 2221 ratemeter/scaler. Per Table 6.7 of MARSSIM (NRC, 2000), the scan MDC for a 2-inch by 2-inch sodium iodide detector ranges from 96 to 132 pCi/g for enriched uranium (depending on the percent enrichment).
Alpha/Beta scanning surveys were performed using a Ludlum 43-89 alpha/beta detector which has a 126 cm2 active window. Per Table 6.4 of MARSSIM (NRC,2000), the scan MDC for U-238 using an alpha scintillation detector with 50 cm2 is 90 dpm/100 cm2. The Ludlum 43-89 probe with 126 cm2 will have a lower MDC.
For volumetric samples the lower limit of detection was consistent with the detection level needed to evaluate environmental samples. Sample will be analyzed by a vendor laboratory for U-238, U-235 and U-234 by alpha spectroscopy method DOE A-01-R and U-235 and U-238 (thorium-234) by gamma spectroscopy method DOE GA-01-R (EML300).
1.3 Number of Sample Locations The number of sample locations was based upon the relative shift between the concentration and the standard deviation of the measurement, and the errors associated with the measurements as presented in NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (NRC, 2000). MARSSIM equation 5-2 approximates the number of data points (N) for a survey unit.
=
( )
(.)
Equation 1 The value of the relative shift (/) is typically selected as a value between 1 and 3. A relative shift of 2.0 was selected; giving rise to a MARSSIM Table 5.4 Sign P of 0.977. A Type I error is sometimes called a false positive. The probability of a Type I error is usually denoted by. A Type II error is sometimes called a false negative. The probability of a Type II error is usually denoted by. Consequences of Type I error is releasing of material with radioactivity higher than the release criterial. Consequence of Type II errors include unnecessary remediation expense and project delays. The error rate for (Type I error) and (Type II error) were selected as 0.05 and 0.05, which results in a Z1-and Z1-of 1.645 and 1.645, respectively.
Using Equation 1, this results in a minimum number of 11.9 sample points required to evaluate the slab and underlying soils. To account for unusable measurements, the number of sample point is increased by 20%.
Thus, a minimum of 15 systematic samples will be performed on a grid. The actual number of sample points may be increased to account for geometric differences and interferences. A systematic rectangular sampling grid will be aligned with the existing building column lines which are spaced 16 feet apart.
2
SUMMARY
OF RADIATION ANALYTICAL RESULTS Characterizations and waste profile analysis were performed upon the remaining concrete slab surfaces of Building 6H to meet the guidance of NUREG-1757 and FC 83-23. These characterizations and waste profile analyses include:
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx 3
- 1. Gamma walkover survey performed by Cabrera of the floor area (Supplemental Radiological Survey Report, March 2018-Cabrera, 2018).
- 2. A alpha / beta one-minute integrated measurements on 74% of the accessible area in 6H/3H performed by Cabrera (Cabrera, 2018).
- 3. Arcadis concrete core samples (December 2018 and April 2019).
- 4. Arcadis concrete core samples (March 2020).
- 5. Arcadis concrete surface contamination (smear) and alpha/beta survey (April 2020).
- 6. Arcadis gamma scan of floor area sample locations (April 2020).
In summary, the data collected to date indicates that the remaining Building 6H concrete slab meets all relevant release criteria and contains no radiological component. Collectively, these results indicate that the foundation material has no radiological component other than NORM.
2.1 Gamma Scan Results Cabrera conduced a gamma walkover survey of accessible areas of the overall Building 6H footprint. The figures discussed below are reproduced in Appendix A. For Column Line 1 to Column Line 14 the accessible area was between 75 and 100 percent. For Column Line 14 to Column Line 26 the accessible area was between 25 and 50 percent as shown in Figure B1 (Figure 1-2, Cabrera 2018). The gamma scan was continuous with readings automatically logged. Figures B2 (Figure 8-1, Cabrera 2018) and B3 (Figure 8-2, Cabrera 2018) present the results. As shown on the figures, the area between Column line 1 and Column Line 26 was divided into 30 smaller areas, for example the rooms along the south wall, or the area between two column lines. The number of measurements, maximum, minimum, mean and standard deviation was reported for each area. The background gamma count was approximately 6,100 counts per minute (cpm).
As reported on the figures, none of the areas had a mean count rate greater than 1.5 times background with the range of mean counts per minute between 6,094 cpm and 9,661 cpm. Only four area had mean count rats above 9,000 cpm. Bias volumetric concrete core samples were performed in those areas and did not indicate elevated activities (See Section 2.3). The slightly elevated the result may be from the proximate wall, or shine (Note - The raw data for these measurements is presented in Appendix I of the Cabrera 2018 report).
In addition, in April 2020, Arcadis performed gamma surveys of areas associated with the twenty-nine surface contamination samples (Figure B4). The counts were logged from a Ludlum 44-10 sodium iodine probe with a 2221 rate meter place adjacent to the surface contamination locations. The areal results ranged from 4,814 to 6,958 counts per minute (cpm) with a mean of 5,854 cpm. None of the areas had a count rate greater than 1.5 times background.
In summary, the gamma scan indicated no elevated areas for the scanned areas with the majority of the scanned areas at background levels.
2.2 Alpha Scan Results Concurrent with the gamma surveys, Cabrera also conduced alpha/beta measurements on the Building 6H floor surfaces as part of their overall supplemental radiological survey (Cabrera, 2018). The figures
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx 4
discussed below are reproduced in Appendix A One-minute integrated alpha/beta scan measurements were performed on floor surfaces in Building 6H, Figures B5 (Figure 8-5, Cabrera 2018) and B6 (Figure 8-6, Cabrera 2018) of the report show the extensive coverage in the area between Column Lines 1 and 26.
As indicated by the color-coded circles on the figures, each representing an alpha/beta measurement, hundreds of measurements were taken. The color-coded results of the measurements indicated no measurement exceeded the surface contamination of less than 5,000 disintegrations per minute (dpm)/100 cm2 total alpha above background (NRC, 2006). Given the number of measurements and extensive coverage of the area, concrete waste from the Building 6H sub-surface foundation is not expected exceed the surface DCGLw. (Note - details of the survey are presented in Section 6.1 of the Cabrera 2018 report).
2.3 Concrete Core samples Tables B1 and B2 present the results of the radiological analyses of concrete core samples. The location of the samples is presented in Figure B7. Sample analysis was by alpha spectroscopy, gamma spectroscopy or both. The alpha spectroscopy samples were one-gram aliquots from the 300 to 500-gram samples required for gamma spectroscopy.
Table B1 presents the results of the December 2018 (nineteen samples) and the April 2019 (six samples) concrete core samples. The locations for the December 2018 sampling campaign were determined using MARRSIM guidance as discussed in the Cleanup Plan (Arcadis 2019). The April biased sampling locations focused on the southern area between Column Lines 12 and 16 in the areas that indicated elevated gamma activity in the 2018 Cabrera survey (See Section 2.1). A review of the data shows the following:
- 1. No sample had an isotopic concentration greater than 0.5 pCi/g of U-238 or U-234. This would indicate these are measurements of background uranium concentrations in the concrete or de-minimis concentrations of HEU.
- 2. The activity concentration results (pCi/g) from alpha spectroscopy samples for U-238 and U-234 are approximately equal indicting natural uranium rather than HEU.
- 3. Gamma spectroscopy results indicate Bi-214 and Pb-214 concentrations (pCi/g) approximately the same as the U-238 concentration indicating secular equilibrium in the U-238 chain reflecting natural uranium. U-238 / U-234 in HEU would not have these daughters in secular equilibrium.
- 4. U-235 results are U qualified or below detection limits for all alpha spectroscopy analyses, much below Highly Enriched Uranium (HEU) expectations.
- 5. The six bias samples only indicated natural uranium with the U-235 and U-238 concentration all less than 0.5 pCi/g.
Table B2 presents the results of the March 2020 sampling campaign which were available. Ten composite samples and 5 discrete samples have been analyzed. As indicated in Figure B7, the area between Column Lines 1 and 30 were divided in to 4 sections. Each section was divided into a north and south subarea. In each subarea (N4, N5, N6, N7, N8, S4, S5, S6, S7, and S8) six cores were collected and composited in one sample. In addition, discrete volumetric samples were collected along the center line of the building at columns 5, 10, 15, 20, and 25 (C5, C10, C15, C20, C25). A total of fifteen (15) concrete core samples were analyzed for radiological components using alpha and gamma spectroscopy. A review of the data to date indicates:
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx 5
- 1. No sample had an isotopic concentration greater than 0.7 pCi/g of U-238 or U-234. This would indicate these are measurements of background uranium concentrations in the concrete or de-minimis concentrations of HEU.
- 2. The activity concentration results (pCi/g) from alpha spectroscopy samples for U-238 and U-234 are approximately equal indicting natural uranium rather than HEU.
- 3. The ratio of the activity concentration results (pCi/g) from alpha spectroscopy samples for U-238 and U-235 reflect a natural uranium ratio rather than HEU even with the large standard deviations.
The forty (40) samples of the concrete foundation in Building 6H indicates the concrete does not contain contamination greater than natural uranium beyond a depth that can be measured by the instrumentation used for the survey.
2.4 Concrete Surface Contamination The levels of fixed and removable surface contamination were analyzed for twenty-nine (29) locations on the Building 6H foundation. The locations surveyed were adjacent to the locations of the March 2020 concrete core samples. The location of the samples is presented in Figure B1.
Prior to sampling the surface was brushed to remove any loose debris and dirt from the surface of the concrete. The face of a Ludlum 43-89 alpha/beta detector with a Ludlum 2360 ratemeter was placed over the sample point and the alpha + beta counts recorded for 1 minute. The 2360 ratemeter also presents alpha and beta counts separately. Each observed alpha and beta count was adjusted to account for the 126 cm2 area, background, concrete self-absorption and detectors efficiency. The alpha and beta concrete self-absorption factors were 0.25 and 0.2968, respectively (MARLAP 2004). Since the face of the detector was 126 cm2, the adjusted counts were normalized to 100 cm2 by dividing each one minute count by 126.
After the probe was removed swipe samples, using dry, glass fiber filters (47 mm Whatman filters), were taken over the designated surface area. The filters per placed into protective envelopes and sent to vendor laboratory for alpha and beta analysis using a gas proportional counter.
Table B3 present the results of the radiological analyses of concrete smear samples. A review of the data indicates:
- 1. None of the counts exceeded the regulatory limit of 5,000 dpm alpha/100 cm2.
- 2. The total alpha contamination results ranged from 0 to 74 dpm alpha /100 cm2 with an average of 16 dpm alpha/100 cm2.These are essentially background total count rates.
- 3. The maximum alpha count rate was 74 dpm alpha/100 cm2 at location N4-SM-C25.Which is less than the maximum surface contamination is 15,000 dpm/100 cm2 alpha.
- 4. The remaining 28 fixed alpha sample count rates were all less than 2% of the limit (range 0 to 59 dpm/100 cm2).
- 5. None of the filter swipes exceeded the regulatory limit of 1000 dpm alpha/100 cm2 for removable contaminations. The removable alpha results ranged from 0 to 4 dpm alpha/100 cm2 with an average of 1 dpm alpha/100 cm2.
There results indicate the materials radioactivity is below release limits.
ADDENDUM TO MAY 2019 CLEANUP PLAN arcadis.com G:\\GE\\PRJ\\GE_UNC_New_Haven\\Reports\\Cleanup Plan\\Addendum\\UNC_Addendum to CUP_App B_Site Background Sampling Method Results_04.27.2020.docx 6
3
SUMMARY
OF NON-RADIATION ANALYTICAL RESULTS As part of the December 2018 building characterization investigation, four concrete floor slab samples were collected within Building 6H and submitted to and analyzed by Eurofins Test America Laboratory for Total PCBs by EPA Method 8082 and Total Inorganics by EPA Method 6010. Three of the four were also analyzed for Toxicity Characteristic Leachate Procedure (TCLP) for Volatile Organic Compounds (VOCs) by EPA Method 8260, Semi-Volatile Organic Compounds (SVOCs) by EPA Method 8270, and Inorganics by EPA Method 6010, and Mercury by EPA Method 7470.
During the month of March 2020, Arcadis collected a total of ten additional concrete floor slab samples over the Building 6H footprint. Sample locations are identified on Figure 1 and include subareas N4 through N8 and S4 through S8.Subareas N4 to N7and S4 to S7 are approximately 3,500 square feet (sf), and Areas N8 and S8 are approximately 2,900 sf. Arcadis collected a six-point composite sample from each subarea that was submitted to and analyzed by Pace National Laboratory for Total PCBs and Inorganics and TCLP VOCs, SVOCs, and Inorganics.
The analytical results from the December 2018 and March 2020 sampling events are collectively presented in Table B4. All results were either non-detect or well below regulatory levels.
4 REFERENCES Arcadis,2019, Cleanup Plan Former United Nuclear Corporation, Naval Products Facility, New Haven, Connecticut Cabrera, 2015 Characterization Survey Report. Site Decommissioning Former UNC Manufacturing Facility, New Haven, Connecticut. Cabrera Services Inc. April, 2015.
Cabrera, 2016 Supplemental Radiological Survey Plan - Buildings 3H/6H (Floor Surfaces) and Former Buildings 9H/10H/11H (Subsurface Soils). Former UNC Manufacturing Facility, New Haven, Connecticut. March 2016.
Cabrera 2018 Remedial Action Completion Report Site Decommissioning Former UNC Manufacturing Facility. November 2018NQR 2002, Memorandum To: John W. Craig, et. al From: Donald A. Cool Re: Update On Case-Specific Licensing Decisions On Controlled Release Of Concrete from Licensed Facilities, December.27, 2002 EML,300 EML Procedures Manual, HASL-300, 28th Edition, Dept of Homeland Security NRC,2000, NUREG-1575, Multi-Agency Radiation Survey and Site Investigation (MARRSIM), Revision 2, 2000 NRC,2002, NQR 2002, Memorandum To: John W. Craig, et. al From: Donald A. Cool Re: Update On Case-Specific Licensing Decisions On Controlled Release Of Concrete from Licensed Facilities, December.27, 2002 NRC,2004 NUREG 1576, Multi-Agency Radiological Laboratory Analytical Protocols Manual (MARLAP),
2004 NRC, 2006, NUREG-1757 Consolidated Decommissioning Guidance-Decommissioning Process for Material Licensees. Vol 1 Revision 2, 2006
TABLES
Table B1 Concrete Core Samples: Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-FS-01 6HE-FS-02 6HE-FS-03 6HE-FS-04 6HE-FS-05 6HE-FS-06 Date Collected:
12/20/18 12/21/18 12/20/18 12/20/18 12/19/18 12/20/18 Sample Name:
6HE-FS-01-1220 6HE-FS-02-1221 6HE-FS-03-1220 6HE-FS-04-1220 6HE-FS-05-1219 6HE-FS-06-1220 Radiochem-Alpha Spectrometry Uranium-238 NA NA NA NA NA NA Uranium-234 NA NA NA NA NA NA Uranium-235 NA NA NA NA NA NA Radiochem-Gamma Emitters Uranium-238 0.529 U +/-0.561 0.328 U +/-0.366 0.201 U +/-0.374 0.432 +/-0.243 0.360 U +/-0.520 0.227 U +/-0.314 Uranium-235
-0.22800 U +/-0.229 0 U +/-0.120 0.0457 U +/-0.271
-0.0314000 U +/-0.0616
-0.23500 U +/-0.274 0.0139 U +/-0.0457 Radiochem-Gamma Emitters-TICs Actinium-228 0.541 +/-0.193 0.617 +/-0.149 0.554 +/-0.175 0.475 +/-0.114 0.542 +/-0.188 0.490 +/-0.153 Bismuth-212 NA NA NA NA NA NA Bismuth-214 0.389 +/-0.143 0.271 +/-0.0823 NA 0.251 +/-0.0920 NA 0.287 +/-0.0898 Lead-210 NA NA NA NA NA NA Lead-212 0.516 +/-0.113 0.484 +/-0.0929 0.398 +/-0.0971 0.329 +/-0.0742 0.515 +/-0.107 0.333 +/-0.0812 Lead-214 0.353 +/-0.126 0.240 +/-0.0751 0.272 +/-0.109 0.214 +/-0.0710 0.407 +/-0.122 0.341 +/-0.0956 Potassium-40 6.86 +/-1.35 8.06 +/-1.32 6.01 +/-1.25 5.14 +/-0.960 6.87 +/-1.34 6.21 +/-1.15 Thallium-208 0.183 +/-0.0616 0.154 +/-0.0424 0.175 +/-0.0583 0.150 +/-0.0359 0.150 +/-0.0630 0.183 +/-0.0536 Location ID:
6HE-FS-07 6HE-FS-08 6HW-FS-01 6HW-FS-02 6HW-FS-03 6HW-FS-04 Date Collected:
12/20/18 12/20/18 12/21/18 12/21/18 12/21/18 12/21/18 Sample Name:
6HE-FS-07-1220 6HE-FS-08-1220 6HW-FS-01-1221 6HW-FS-02-1221 6HW-FS-03-1221 6HW-FS-04-1221 Radiochem-Alpha Spectrometry Uranium-238 NA NA NA NA NA NA Uranium-234 NA NA NA NA NA NA Uranium-235 NA NA NA NA NA NA Radiochem-Gamma Emitters Uranium-238 0.343 U +/-0.374 0.131 U +/-0.520 0.275 U +/-0.460 0.369 U +/-0.401
-0.17500 U +/-0.621 0.640 U +/-0.586 Uranium-235 0.0612 U +/-0.148
-0.14500 U +/-0.463 0 U +/-0.168 0.0522 U +/-0.129
-0.0298000 U +/-0.0549
-0.21500 U +/-0.292 Radiochem-Gamma Emitters-TICs Actinium-228 0.607 +/-0.174 0.722 +/-0.158 0.421 +/-0.125 0.521 +/-0.175 0.404 +/-0.146 0.435 +/-0.214 Bismuth-212 NA NA NA NA 0.918 +/-0.339 NA Bismuth-214 0.281 +/-0.116 0.490 +/-0.129 0.378 +/-0.112 0.329 +/-0.119 0.280 +/-0.0911 0.254 +/-0.101 Lead-210 NA NA NA NA NA NA Lead-212 0.442 +/-0.101 0.512 +/-0.102 0.344 +/-0.0872 0.354 +/-0.0979 0.377 +/-0.0780 0.426 +/-0.0932 Lead-214 0.300 +/-0.104 0.276 +/-0.0867 0.333 +/-0.101 NA 0.210 +/-0.0654 0.422 +/-0.105 Potassium-40 5.66 +/-1.22 7.29 +/-1.25 6.22 +/-1.14 5.64 +/-1.20 6.02 +/-1.06 5.94 +/-1.19 Thallium-208 0.185 +/-0.0628 0.231 +/-0.0759 0.168 +/-0.0622 0.143 +/-0.0710 0.137 +/-0.0471 0.105 +/-0.0457 Location ID:
6HW-FS-05 6HS-FS-01 6HS-FS-02 6HS-FS-03 6HS-FS-04 6HS-FS-05 Date Collected:
12/21/18 04/04/19 04/04/19 04/04/19 04/04/19 04/04/19 Sample Name:
6HW-FS-05-1221 6HS-FS-01-0404 6HS-FS-02-0404 6HS-FS-03-0404 6HS-FS-04-0404 6HS-FS-05-0404 Radiochem-Alpha Spectrometry Uranium-238 NA 0.486 +/-0.138 0.437 +/-0.130 0.307 +/-0.113 0.329 +/-0.121 0.331 +/-0.111 Uranium-234 NA 1.00 U +/-0.0319 1.00 U +/-0.0326 1.00 U +/-0.0325 1.00 U +/-0.0540 1.00 U +/-0.0370 Uranium-235 NA 0.292 +/-0.106 0.303 +/-0.106 0.220 +/-0.0930 0.307 +/-0.114 0.329 +/-0.110 Radiochem-Gamma Emitters Uranium-238
-0.25400 U +/-0.513 1.00 U +/-0.580 1.00 U +/-0.303 1.00 U +/-0.415 1.00 U +/-0.437 1.00 U +/-0.0281 Uranium-235 0.0262 U +/-0.144 2.50 U +/-0.519 2.50 U +/-0.568 2.50 U +/-0.493 2.50 U +/-0.244 2.50 U +/-0.548 Radiochem-Gamma Emitters-TICs Actinium-228 NA 0.716 +/-0.203 0.769 +/-0.171 0.783 +/-0.253 0.803 +/-0.162 NA Bismuth-212 NA NA 0.942 +/-0.411 NA NA NA Bismuth-214 0.307 +/-0.0970 NA 0.283 +/-0.103 0.337 +/-0.133 0.379 +/-0.133 NA Lead-210 NA NA 3.97 +/-1.69 NA NA NA Lead-212 0.336 +/-0.0796 0.617 +/-0.127 0.609 +/-0.117 0.514 +/-0.115 0.534 +/-0.119 0.509 +/-0.107 Lead-214 0.284 +/-0.0709 0.348 +/-0.120 0.427 +/-0.109 0.378 +/-0.124 0.476 +/-0.137 0.317 +/-0.106 Potassium-40 5.25 +/-1.03 8.49 +/-1.64 10.4 +/-1.62 7.93 +/-1.66 7.95 +/-1.56 7.61 +/-1.30 Thallium-208 NA 0.213 +/-0.0654 0.209 +/-0.0555 0.233 +/-0.0798 0.203 +/-0.0763 0.168 +/-0.0624 T-1-1
Table B1 Concrete Core Samples: Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HS-FS-06 Date Collected:
04/04/19 Sample Name:
6HS-FS-06-0404 Radiochem-Alpha Spectrometry Uranium-238 0.308 +/-0.106 Uranium-234 1.00 U +/-0.0214 Uranium-235 0.284 +/-0.101 Radiochem-Gamma Emitters Uranium-238 1.00 U +/-0.282 Uranium-235 2.50 U +/-0.553 Radiochem-Gamma Emitters-TICs Actinium-228 0.463 +/-0.141 Bismuth-212 NA Bismuth-214 0.301 +/-0.110 Lead-210 NA Lead-212 0.331 +/-0.0884 Lead-214 0.259 +/-0.0997 Potassium-40 6.90 +/-1.21 Thallium-208 0.186 +/-0.0596 Notes:
- 1. All samples were collected by Arcadis on the dates indicated and submitted to Test America Laboratories for analysis.
- 2. Sample analysis was conducted using the following Methods:
Isotopic Uranium (Alpha Spectrometry): Method A-01-R Cesium-137 & Other Gamma Emmitters (GS): Method GA-01-R
- 3. NA = Constituent was not analyzed.
- 4. ND = Analyte not detected at a concentration greater than the Practical Quantitation Limit (PQL).
PQL denotes lowest reportable analyte concentration.
- 5. Units: pCi/g = average picocuries per gram
- 6. Sample ID Nomenclature: BUILDING - (FLOOR) - MEDIA - NUMBER (##) - DATE (MMYY)
Building IDs:
Media IDs (where applicable):
6H: Building 6H FS: Floor/Systematic 6HE: Building 6H - Eastside 6HW: Building 6H - Westside
- 7. Laboratory Qualifiers:
U Result is less than the sample detection limit.
G The Sample Method Detectable Concentration is greater than the requested Reporting Limit.
T-1-2
Table B2 Systematic Concrete Core Samples: Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
N4-CC-01 N5-CC-01 N7-CC-01 N8-CC-01 S4-CC-01 S5-CC-01 S6-CC-01 Date Collected:
03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 Sample Name: N4-CC-01-030620 N5-CC-01-030620 N7-CC-01-030620 N8-CC-01-030620 S4-CC-01-030620 S5-CC-01-030620 S6-CC-01-030620 Radiochem-Alpha Spectrometry Uranium-234 0.397 +/-0.129 0.259 +/-0.135 0.231 +/-0.136 0.477 +/-0.242 0.285 +/-0.114 0.210 +/-0.118 0.311 +/-0.124 Uranium-235 0.0195 +/-0.0353 0.0361 +/-0.0489 0.0138 +/-0.0363 0.0608 +/-0.0956 0.0101 +/-0.0408 0.0320 +/-0.0520 0.0121 +/-0.0396 Uranium-238 0.298 +/-0.101 0.245 +/-0.113 0.269 +/-0.108 0.415 +/-0.222 0.338 +/-0.110 0.405 +/-0.111 0.330 +/-0.107 Radiochem-Gamma Emitters Thorium-234 0.130 +/-0.744 0.0895 +/-0.718
-0.0857000 +/-0.609 0.583 +/-0.521
-0.17200 +/-0.537 0.343 +/-0.673 0.763 +/-0.644 Uranium-235 0.0736 +/-0.0859 0.146 +/-0.0863 0.121 +/-0.0847 0.0359 +/-0.0558 0.110 +/-0.0658 0.0751 +/-0.0645 0.0649 +/-0.0632 Location ID:
S7-CC-01 S8-CC-01 N6-CC-01 6H-CG-C5 6H-CG-C10 6H-CG-C15 6H-CG-C20 Date Collected:
03/06/20 03/06/20 03/26/20 03/26/20 03/26/20 03/26/20 03/26/20 Sample Name: S7-CC-01-030620 S8-CC-01-030620 N6-CC-01-032620 6H-CG-C5-0326206H-CG-C10-0326206H-CG-C15-0326206H-CG-C20-032620 Radiochem-Alpha Spectrometry Uranium-234 0.366 +/-0.293 0.621 +/-0.175 0.719 +/-0.205 0.361 +/-0.133 0.669 +/-0.186 0.558 +/-0.177 0.930 +/-0.218 Uranium-235 0.0170 +/-0.0740 0.0165 +/-0.0509 0.0352 +/-0.0584 0.00464 +/-0.0307 0.0561 +/-0.0631 0.0181 +/-0.0446 0.0566 +/-0.0566 Uranium-238 0.327 +/-0.196 0.562 +/-0.154 0.786 +/-0.214 0.488 +/-0.137 0.657 +/-0.185 0.592 +/-0.173 1.13 +/-0.220 Radiochem-Gamma Emitters Thorium-234 0.471 +/-0.624 0.0895 +/-0.580 0.785 +/-0.727 NA NA NA NA Uranium-235 0.0289 +/-0.0570 0.151 +/-0.0773 0.0848 +/-0.0819 NA NA NA NA Location ID:
6H-CG-C25 Date Collected:
03/26/20 Sample Name: 6H-CG-C25-032620 Radiochem-Alpha Spectrometry Uranium-234 0.340 +/-0.140 Uranium-235 0.0539 +/-0.0608 Uranium-238 0.328 +/-0.126 Radiochem-Gamma Emitters Thorium-234 NA Uranium-235 NA Notes:
Sample Area IDs:
- 1. All samples were collected by Arcadis on the dates indicated and submitted to Test America Laboratories for analysis.
N: Northern portion of Building 6H
- 2. Sample analysis was conducted using the following Methods:
S: Southern portion Building 6H Isotopic Uranium (Alpha Spectrometry): Method A-01-R Cesium-137 & Other Gamma Emmitters (GS): Method GA-01-R Media IDs (where applicable):
- 3. NA = Constituent was not analyzed.
CC: Concrete Composite
- 4. ND = Analyte not detected at a concentration greater than the Practical Quantitation Limit (PQL).
CG: Concrete Grab PQL denotes lowest reportable analyte concentration.
- 5. Units: pCi/g = average picocuries per gram
- 6. Sample ID Nomenclature: BUILDING - (FLOOR) - MEDIA - NUMBER (##) - DATE (MMYY)
T-2-1
Table B3 Fixed and Removal Contamination Swipe Sample: Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
Date Collected:
Raw Alpha + Beta (cpm/126 cm2 )
Raw Alpha (cpm/126 cm2 )
Total Fixed Alpha (dpm a/100 cm2 )
Total Removable Alpha (dpm a/100 cm2 )
Gamma (cpm) 6H-SM-C5 04/15/20 261 1
15 0 +/- 1.7 5140 6H-SM-C10 04/15/20 235 2
29 0 +/- 1.7 5058 6H-SM-C15 04/15/20 272 0
0
-1.2 +/- 1.2 6530 6H-SM-C20 04/15/20 295 2
29 3.7 +/- 2.7 5606 6H-SM-C25 04/15/20 238 3
44 2.5 +/- 2.4 5892 N8-SM-C2 04/15/20 479 2
29 0 +/- 1.7 6688 N8-SM-C3-4 04/15/20 251 0
0
-1.2 +/- 1.2 5742 N8-SM-C5 04/15/20 225 0
0 2.5 +/- 2.4 5262 S8-SM-C2 04/15/20 244 0
0 0 +/- 1.7 6234 S8-SM-C3-4 04/15/20 312 0
0 2.5 +/- 2.4 6958 S8-SM-C5 04/15/20 260 0
0 1.2 +/- 2.1 5684 N7-SM-C7 04/15/20 215 0
0
-1.2 +/- 1.2 5540 N7-SM-C9 04/15/20 213 0
0 0 +/- 1.7 4814 N7-SM-C11 04/15/20 250 1
15 0 +/- 1.7 5744 S7-SM-C7 04/15/20 226 1
15
-1.2 +/- 1.2 5606 S7-SM-C9 04/15/20 228 4
59 3.7 +/- 2.7 5830 S7-SM-C11 04/15/20 278 0
0 1.2 +/- 2.1 5778 N6-SM-C13 04/15/20 241 1
15 2.5 +/- 2.4 5662 N6-SM-C15 04/15/20 225 1
15 3.7 +/- 2.7 6296 S6-SM-C13 04/15/20 219 1
15 0 +/- 1.7 5680 S6-SM-C15 04/15/20 225 0
0 2.5 +/- 2.4 6226 N5-SM-C19 04/15/20 236 0
0 3.7 +/- 2.7 5862 N5-SM-C21 04/15/20 239 2
29 1.2 +/- 2.1 5482 N5-SM-C23 04/15/20 272 0
0
-1.2 +/- 1.2 6136 S5-SM-C19 04/15/20 241 2
29
-1.2 +/- 1.2 5902 S5-SM-C21 04/15/20 226 0
0 0 +/- 1.7 5888 S5-SM-C23 04/15/20 281 3
44 0 +/- 1.7 6454 N4-SM-C25 04/15/20 239 5
74
-1.2 +/- 1.2 6078 S4-SM-C25 04/15/20 266 0
0 1.2 +/- 2.1 5992 Minimum 0
0 4814 Maximum 74 4
6958 Average 16 1
5854 Limit 5000 1000 Probe Serial Number Ratemeter /Scaler Serial Number alpha background 0
Ludlum 43-93 PR 388185 Ludlum 2360 141322 beta background 169 Ludlum 44-10 168571 Ludlum 2221 322674 Gamma background 6100 T-3-1
Table B4 Concrete Core Samples: Non-Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-FS-05 6HE-FS-07 6HW-FS-03 6HW-FS-05 Date Collected:
12/19/18 12/20/18 12/21/18 12/21/18 Sample Name:
6HE-FS-05-1219 6HE-FS-07-1220 6HW-FS-03-1221 6HW-FS-05-1221 PCBs Aroclor 1016 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Aroclor 1221 0.35 U 0.084 U 0.34 U [1.8 U]
0.085 U Aroclor 1232 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Aroclor 1242 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Aroclor 1248 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Aroclor 1254 1.1 0.26 1.5 [7.7]
0.43 Aroclor 1260 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Aroclor 1262 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Aroclor 1268 0.25 U 0.059 U 0.24 U [1.3 U]
0.06 U Total PCBs 1.1 0.26 1.5 [7.7]
0.43 Inorganics Arsenic 1.6 J 1.6 J 2.5 J [2.1]
1.7 Barium 44 46 41 [24]
19 Cadmium 0.91 U 0.94 U 0.94 U [0.48 U]
0.42 U Chromium 16 15 18 [8.8]
6.8 Lead 2.3 17 1.2 J [0.27 J]
0.41 J Mercury 0.019 J 0.024 J 0.064 [0.048]
0.057 Selenium 2.7 U 2.8 U 2.8 U [1.4 U]
1.3 U Silver 1.8 U 1.9 U 1.9 U [0.96 U]
0.84 U Inorganics-TCLP Arsenic 0.50 U 0.50 U NA 0.50 U Barium 0.30 J 0.23 J NA 0.29 J Cadmium 0.10 U 0.10 U NA 0.10 U Chromium 0.0081 J 0.064 J NA 0.020 J Lead 0.50 U 0.50 U NA 0.50 U Mercury 0.0020 U 0.0020 U NA 0.0020 U Selenium 0.10 U 0.10 U NA 0.10 U Silver 0.50 U 0.50 U NA 0.50 U VOCs-TCLP 1,1-Dichloroethene 0.010 U 0.010 U NA 0.010 U 1,2-Dichloroethane 0.010 U 0.010 U NA 0.010 U 2-Butanone (MEK) 0.10 U 0.10 U NA 0.10 U Carbon Tetrachloride 0.010 U 0.010 U NA 0.010 U Chlorobenzene 0.010 U 0.010 U NA 0.010 U Chloroform 0.010 U 0.010 U NA 0.010 U Tetrachloroethene 0.010 U 0.010 U NA 0.010 U Trichloroethene 0.010 U 0.010 U NA 0.010 U Vinyl chloride 0.010 U 0.010 U NA 0.010 U Benzene 0.010 U 0.010 U NA 0.010 U SVOCs-TCLP 1,4-Dichlorobenzene 0.020 U 0.020 U NA 0.020 U 2,4,5-Trichlorophenol 0.050 U 0.050 U NA 0.050 U 2,4,6-Trichlorophenol 0.025 U 0.025 U NA 0.025 U 2,4-Dinitrotoluene 0.050 U 0.050 U NA 0.050 U 2-Methylphenol 0.050 U 0.050 U NA 0.050 U 4-Methylphenol 0.050 U 0.050 U NA 0.050 U Hexachloro-1,3-butadiene 0.050 U 0.050 U NA 0.050 U Hexachlorobenzene 0.050 U 0.050 U NA 0.050 U Hexachloroethane 0.050 U 0.050 U NA 0.050 U Nitrobenzene 0.050 U 0.050 U NA 0.050 U Pentachlorophenol 0.25 U 0.25 U NA 0.25 U Pyridine 0.10 U 0.10 U NA 0.10 U T-4-1
Table B4 Concrete Core Samples: Non-Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
6HE-FS-05 6HE-FS-07 6HW-FS-03 6HW-FS-05 Date Collected:
12/19/18 12/20/18 12/21/18 12/21/18 Sample Name:
6HE-FS-05-1219 6HE-FS-07-1220 6HW-FS-03-1221 6HW-FS-05-1221 PCBs-TCLP Aroclor 1016 0.01 U 0.01 U NA 0.01 U Aroclor 1221 0.01 U 0.01 U NA 0.01 U Aroclor 1232 0.01 U 0.01 U NA 0.01 U Aroclor 1242 0.01 U 0.01 U NA 0.01 U Aroclor 1248 0.01 U 0.01 U NA 0.01 U Aroclor 1254 0.01 U 0.01 U NA 0.01 U Aroclor 1260 0.01 U 0.01 U NA 0.01 U Aroclor 1262 0.01 U 0.01 U NA 0.01 U Aroclor 1268 0.01 U 0.01 U NA 0.01 U Total PCBs 0.01 U 0.01 U NA 0.01 U Location ID:
N4-CC-01 N5-CC-01 N7-CC-01 N8-CC-01 S4-CC-01 S5-CC-01 Date Collected:
03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 Sample Name:
N4-CC-01-030620 N5-CC-01-030620 N7-CC-01-030620 N8-CC-01-030620 S4-CC-01-030620 S5-CC-01-030620 PCBs Aroclor 1016 0.0183 U 0.0182 U 0.0177 U 0.0179 U 0.0182 U 0.0182 U Aroclor 1221 0.0183 U 0.0182 U 0.0177 U 0.0179 U 0.0182 U 0.0182 U Aroclor 1232 0.0183 U 0.0182 U 0.0177 U 0.0179 U 0.0182 U 0.0182 U Aroclor 1242 0.0183 U 0.0182 U 0.0177 U 0.0179 U 0.0182 U 0.0182 U Aroclor 1248 0.0183 U 0.0182 U 0.0177 U 0.0179 U 0.0182 U 0.0182 U Aroclor 1254 0.642 0.149 0.861 1.57 0.148 0.0659 Aroclor 1260 0.0183 U 0.0182 U 0.0177 U 0.0179 U 0.0182 U 0.0182 U Total PCBs 0.642 0.149 0.861 1.57 0.148 0.0659 Inorganics Arsenic 2.16 U 2.14 U 3.09 1.38 J 0.507 J 2.14 U Barium 34.8 42.6 O1 60.6 49.7 49.6 46.4 Cadmium 0.168 J 0.189 J 0.155 J 0.164 J 0.218 J 0.123 J Chromium 10.9 14.6 O1 39.0 17.2 12.8 14.2 Lead 4.71 9.10 8.73 3.26 53.6 4.28 Mercury 0.0316 J 0.0176 J 0.0314 0.0226 J 0.0468 0.0214 J Selenium 1.45 J 1.33 J 1.20 J 1.66 J 1.30 J 1.55 J Silver 1.08 U 1.07 U 1.04 U 1.06 U 1.07 U 1.07 U Inorganics-TCLP Arsenic 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Barium 0.422 0.394 0.449 0.431 0.265 0.281 Cadmium 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Chromium 0.100 U 0.100 U 0.117 0.100 U 0.100 U 0.100 U Lead 0.100 U 0.137 0.100 U 0.100 U 0.100 U 0.100 U Mercury 0.0100 U 0.0100 U 0.0100 U 0.0100 U 0.0100 U 0.0100 U Selenium 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Silver 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U VOCs-TCLP 1,1-Dichloroethene 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 1,2-Dichloroethane 0.0500 U J4 0.0500 U J4 0.0500 U J4 0.0500 U J4 0.0500 U J4 0.0500 U J4 2-Butanone (MEK) 0.500 U 0.500 U 0.500 U 0.500 U 0.500 U 0.500 U Carbon Tetrachloride 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U Chlorobenzene 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U Chloroform 0.250 U 0.250 U 0.250 U 0.250 U 0.250 U 0.250 U Tetrachloroethene 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U Trichloroethene 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U Vinyl chloride 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U Benzene 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U 0.0500 U T-4-2
Table B4 Concrete Core Samples: Non-Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
N4-CC-01 N5-CC-01 N7-CC-01 N8-CC-01 S4-CC-01 S5-CC-01 Date Collected:
03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 03/06/20 Sample Name:
N4-CC-01-030620 N5-CC-01-030620 N7-CC-01-030620 N8-CC-01-030620 S4-CC-01-030620 S5-CC-01-030620 SVOC-TCLP 1,4-Dichlorobenzene 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 2,4,5-Trichlorophenol 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 2,4,6-Trichlorophenol 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 2,4-Dinitrotoluene 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 2-Methylphenol 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 3-Methylphenol, 4-Methylphenol 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Hexachloro-1,3-butadiene 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Hexachlorobenzene 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Hexachloroethane 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Nitrobenzene 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Pentachlorophenol 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Pyridine 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U 0.100 U Location ID:
S6-CC-01 S7-CC-01 S8-CC-01 N6-CC-01 Date Collected:
03/06/20 03/06/20 03/06/20 03/26/20 Sample Name:
S6-CC-01-030620 S7-CC-01-030620 S8-CC-01-030620 N6-CC-01-032620 PCBs Aroclor 1016 0.0183 U 0.0179 U 0.0180 U 0.0192 U Aroclor 1221 0.0183 U 0.0179 U 0.0180 U 0.0192 U Aroclor 1232 0.0183 U 0.0179 U 0.0180 U 0.0192 U Aroclor 1242 1.54 0.0179 U 0.0180 U 0.0192 U Aroclor 1248 0.0183 U 0.0179 U 0.0180 U 0.0192 U Aroclor 1254 0.940 1.38 0.0180 U 0.879 Aroclor 1260 0.0183 U 0.0179 U 0.0180 U 0.0192 U Total PCBs 2.48 1.38 0.0180 U 0.879 Inorganics Arsenic 2.16 U 0.752 J 1.13 J NA Barium 46.9 49.2 47.8 NA Cadmium 0.143 J 0.208 J 0.162 J NA Chromium 16.2 16.5 17.3 NA Lead 4.31 7.13 4.35 NA Mercury 0.425 0.124 0.0153 J NA Selenium 1.42 J 1.45 J 1.35 J NA Silver 1.08 U 1.06 U 1.06 U NA Inorganics-TCLP Arsenic 0.100 U 0.100 U 0.100 U 0.100 U Barium 0.396 0.303 0.326 0.413 Cadmium 0.100 U 0.100 U 0.100 U 0.100 U Chromium 0.100 U 0.100 U 0.100 U 0.100 U Lead 0.100 U 0.100 U 0.100 U 0.100 U Mercury 0.0100 U 0.0100 U 0.0100 U 0.0100 U Selenium 0.100 U 0.100 U 0.100 U 0.100 U Silver 0.100 U 0.100 U 0.100 U 0.100 U VOCs-TCLP 1,1-Dichloroethene 0.0500 U 0.0500 U 0.0500 U 0.0500 U 1,2-Dichloroethane 0.0500 U J4 0.0500 U J4 0.0500 U J4 0.0500 U 2-Butanone (MEK) 0.500 U 0.500 U 0.500 U 0.500 U Carbon Tetrachloride 0.0500 U 0.0500 U 0.0500 U 0.0500 U Chlorobenzene 0.0500 U 0.0500 U 0.0500 U 0.0500 U Chloroform 0.250 U 0.250 U 0.250 U 0.250 U Tetrachloroethene 0.0500 U 0.0500 U 0.0500 U 0.0500 U Trichloroethene 0.0500 U 0.0500 U 0.0500 U 0.0500 U Vinyl chloride 0.0500 U 0.0500 U 0.0500 U 0.0500 U Benzene 0.0500 U 0.0500 U 0.0500 U 0.0500 U T-4-3
Table B4 Concrete Core Samples: Non-Radiological Characteristics Addendum to May 2019 Cleanup Plan General Electric Company - Former UNC Facility New Haven, Connecticut Location ID:
S6-CC-01 S7-CC-01 S8-CC-01 N6-CC-01 Date Collected:
03/06/20 03/06/20 03/06/20 03/26/20 Sample Name:
S6-CC-01-030620 S7-CC-01-030620 S8-CC-01-030620 N6-CC-01-032620 SVOC-TCLP 1,4-Dichlorobenzene 0.100 U 0.100 U 0.100 U 0.100 U 2,4,5-Trichlorophenol 0.100 U 0.100 U 0.100 U 0.100 U 2,4,6-Trichlorophenol 0.100 U 0.100 U 0.100 U 0.100 U 2,4-Dinitrotoluene 0.100 U 0.100 U 0.100 U 0.100 U 2-Methylphenol 0.100 U 0.100 U 0.100 U 0.100 U 3-Methylphenol, 4-Methylphenol 0.100 U 0.100 U 0.100 U 0.100 U Hexachloro-1,3-butadiene 0.100 U 0.100 U 0.100 U 0.100 U Hexachlorobenzene 0.100 U 0.100 U 0.100 U 0.100 U Hexachloroethane 0.100 U 0.100 U 0.100 U 0.100 U Nitrobenzene 0.100 U 0.100 U 0.100 U 0.100 U Pentachlorophenol 0.100 U 0.100 U 0.100 U 0.100 U Pyridine 0.100 U 0.100 U 0.100 U 0.100 U Notes:
- 1. All samples were collected by Arcadis on the dates indicated and submitted to Test America Laboratories for analysis.
- 2. Sample analysis was conducted using the following Methods:
Total VOCs: United States Environmental Protection Agency (USEPA) SW-846 Method 8260 Total SVOCs: USEPA SW-846 Method 8270 Total Inorganics: USEPA SW-846 Method 6010 PCBs: USEPA SW-846 Method 8082 Total Mercury: USEPA SW-846 Method 7470 TCLP VOCs: USEPA SW-846 Method 1311:Toxicity Characteristic Leaching Procedure and Method 8260 TCLP SVOCs: USEPA SW-846 Method 1311 and Method 8270 TCLP Inorganics:USEPA SW-846 Method 1311 and Method 6010 TCLP PCBs: USEPA SW-846 Method 1311 and Method 8082
- 3. NA = Constituent was not analyzed.
- 4. Units: mg/kg = milligram per kilogram
- 5. [ ] = Duplicate sample results.
- 6. Laboratory Qualifiers:
p U
The compound was analyzed for but not detected. The associated value is the compound quantitation limit.
J4 The associated batch QC was outside the established quality control range for accuracy.
J The identification of the analyte is acceptable; the reported value is an estimate.
- 7. Sample ID Nomenclature: BUILDING - (FLOOR) - MEDIA - NUMBER (##) - DATE (MMYY)
Building/Sample IDs:
Media IDs (where applicable):
6H: Building 6H FS: Floor/Systematic 6HE: Building 6H - Eastside CC: Composite Concrete 6HW: Building 6H - Westside N: Northern portion of Building 6H S: Southern portion Building 6H The Relative Percent Difference (%RPD) between the primary and confirmation column/detector is >40%.
The lower value has been reported.
T-4-4
FIGURES
3H 6H (Fabrication Shop) 6H 44H 14H 7H 8H 9H 10H 11H 19H 41H 50H ARGYLE STREET Decontamination Pit Intact Ductwork SHELTON AVENUE Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GIS User Community 0
80 160 Scale (feet)
PROJECT No. 10-1007.00 10/2017 FIGURE 1-2 FORMER UNC FACILITY NEW HAVEN, CONNECTICUT BUILDING 3H/ 6H ACESSIBLE AREA Legend Intact Ductwork Buildings Existing Building Demolished Building Accessible Area Percent 0 to 25%
>25 to 50%
>50 to 75%
>75 to 100%
Unknown p
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
BUILDING 6H WEST UNC-GWS-02 Count 2,723 Min 4,246 Max 16,687 Mean 6,074 SD 1,136 UNC-GWS-03 Count 1,443 Min 3,996 Max 9,518 Mean 5,632 SD 897 UNC-GWS-01 Count 2,182 Min 4,025 Max 8,187 Mean 5,123 SD 437 UNC-GWS-04 Count 2,418 Min 4,443 Max 9,845 Mean 6,084 SD 876 UNC-GWS-05 Count 1,572 Min 5,160 Max 10,800 Mean 6,880 SD 734 UNC-GWS-20 Count 794 Min 5,030 Max 11,102 Mean 7,517 SD 894 UNC-GWS-23 Count 527 Min 4,645 Max 9,643 Mean 6,532 SD 880 UNC-GWS-21 Count 526 Min 5,380 Max 10,412 Mean 7,111 SD 871 UNC-GWS-06 Count 545 Min 4,581 Max 9,395 Mean 6,325 SD 899 UNC-GWS-17 Count 250 Min 6,708 Max 12,172 Mean 9,650 SD 1,029 UNC-GWS-22 Count 551 Min 4,128 Max 10,425 Mean 6,946 SD 988 UNC-GWS-09 Count 228 Min 6,565 Max 11,030 Mean 8,530 SD 687 UNC-GWS-14 Count 306 Min 7,012 Max 12,390 Mean 8,836 SD 821 UNC-GWS-19 Count 278 Min 7,233 Max 12,683 Mean 9,639 SD 1,045 UNC-GWS-18 Count 341 Min 6,221 Max 13,594 Mean 9,607 SD 969 UNC-GWS-10 Count 255 Min 6,809 Max 11,117 Mean 8,276 SD 594 UNC-GWS-13 Count 323 Min 6,627 Max 11,875 Mean 8,891 SD 731 UNC-GWS-07 Count 638 Min 5,038 Max 8,680 Mean 6,457 SD 634 UNC-GWS-16 Count 706 Min 7,053 Max 12,347 Mean 9,361 SD 921 UNC-GWS-15 Count 88 Min 6,998 Max 10,160 Mean 8,415 SD 622 UNC-GWS-08 Count 1,112 Min 4,419 Max 11,229 Mean 7,119 SD 1,153 UNC-GWS-12 Count 215 Min 4,950 Max 10,367 Mean 8,472 SD 859 UNC-GWS-11 Count 138 Min 6,851 Max 10,737 Mean 8,357 SD 748 4
1 7
1 3
4 7
9 10 12 16 17 15 14 13 11 15 10 13 17 14 18 11 16 12 8
5 2
6 3
8 9
6 5
2 p
0 20 40 Scale (feet)
PROJECT No. 10-1007.00 10/2017 FIGURE 8-1 FORMER UNC FACILITY NEW HAVEN, CONNECTICUT GAMMA WALKOVER SURVEY SCAN AREA RESULTS Legend Area of Elevated Gamma Activity GWS Scan Area Results (Max cpm)
< 11,999.9
> 12,000 (IL)
Building 3H Building 6H
")
Building Columns Note: Survey performed with Ludlum 2360/ FIDLER.
Survey results are in counts per minute (cpm).
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
")
BUILDING 6H CENTER UNC-GWS-30 Count 1,689 Min 4,097 Max 11,564 Mean 7,285 SD 1,186 UNC-GWS-35 Count 1,934 Min 5,559 Max 849,607 Mean 12,931 SD 46,571 UNC-GWS-23 Count 527 Min 4,645 Max 9,643 Mean 6,532 SD 880 UNC-GWS-26 Count 795 Min 4,095 Max 9,005 Mean 6,305 SD 695
-21 6
0 412 11 UNC-GWS-28 Count 474 Min 3,999 Max 8,811 Mean 6,790 SD 657 UNC-GWS-39 Count 435 Min 6,654 Max 14,737 Mean 9,125 SD 1,091 UNC-GWS-29 Count 708 Min 4,908 Max 9,345 Mean 6,813 SD 630 UNC-GWS-25 Count 542 Min 4,725 Max 9,866 Mean 6,302 SD 862 UNC-GWS-22 Count 551 Min 4,128 Max 10,425 Mean 6,946 SD 988 UNC-GWS-27 Count 678 Min 4,072 Max 8,801 Mean 6,414 SD 659 UNC-GWS-24 Count 537 Min 4,342 Max 10,110 Mean 6,622 SD 932 UNC-GWS-19 Count 278 Min 7,233 Max 12,683 Mean 9,639 SD 1,045 S-18 341 21
,594
,607 UNC-GWS-37 Count 275 Min 6,711 Max 9,734 Mean 8,194 SD 638 UNC-GWS-38 Count 163 Min 7,890 Max 10,828 Mean 9,338 SD 543 31 22 30 25 27 19 26 28 21 29 16 23 24 25 26 27 29 30 31 32 28 22 21 20 19 18 17 20 34 32 23 17 24 18 33 16 6
5 4
3 118 117 116 115 15 1
2 7
p 0
20 40 Scale (feet)
PROJECT No. 10-1007.00 10/2017 FIGURE 8-2 FORMER UNC FACILITY NEW HAVEN, CONNECTICUT GAMMA WALKOVER SURVEY SCAN AREA RESULTS Legend Area of Elevated Gamma Activity GWS Scan Area Results (Max cpm)
< 11,999.9
> 12,000 (IL)
Building 3H Building 6H
")
Building Columns Note: Survey performed with Ludlum 2360/ FIDLER.
Survey results are in counts per minute (cpm).
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SPRINKLER CONTROL OPEN PIPE GAS VALVE FARMINGTON CANAL GREENWAY SHELTON AVENUE BUILDING 3H SLAB, FOUNDATION, AND SOIL REMOVAL COMPLETE N8 N7 N6 N5 N4 S8 S7 S6 S5 S4 BUILDING 6H WEST BUILDING 6H EAST FIGURE LOCATION OF SLAB SURFACE CONTAMINATION MEASUREMENTS/SMEARS FORMER UNITED NUCLEAR CORPORATION FACILITY 71 SHELTON AVENUE NEW HAVEN, CONNECTICUT B4 CITY: SYRACUSE, NY DIV/GROUP: EBC-IM/DV DB: L.POSENAUER PM/TM: R.GIAMPAOLO LYR:(Opt)ON=*;OFF=*REF*
C:\\Users\\ssteele\\BIM 360\\Arcadis\\ANA - GE CORP ENV PROG\\Project Files\\GE UNC NEW HAVEN - ENGINEERING\\2020\\30006255\\01-DWG\\GE-UNC_SITE SAMPLE LAYOUTdwg.dwg LAYOUT: B4 SAVED: 4/23/2020 12:52 PM ACADVER: 23.0S (LMS TECH) PAGESETUP: ---- PLOTSTYLETABLE:
ACAD.CTB PLOTTED: 4/23/2020 3:40 PM BY: STEELE, SAM N8
BUILDING 6H WEST 2
4 1
5 6
9 7
8 3
6 1
2 3
4 5
7 8
9 12 16 11 14 13 10 15 10 11 12 13 14 15 16 p
0 20 40 Scale (feet)
PROJECT No. 10-1007.00 10/2017 FIGURE 8-5 FORMER UNC FACILITY NEW HAVEN, CONNECTICUT ALPHA-BETA FLOOR SCAN SURVEY RESULTS Legend Area of Elevated Gamma Activity Floor Scan Results (Alpha + Beta dpm/100 cm2)
< 99.9 100 - 2,499.9 2,500 - 4,999.9
> 5,000 Building 3H Building 6H
")
Building Columns Note: Survey performed with Ludlum 2360/ 43-37. All measurements are 1-min integrated scans. Survey results represent the centroid of the area scanned during the 1-min interval.
BUILDING 6H CENTER 118 117 31 22 30 18 25 24 17 23 27 19 26 28 21 29 20 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 p
0 20 40 Scale (feet)
PROJECT No. 10-1007.00 10/2017 FIGURE 8-6 FORMER UNC FACILITY NEW HAVEN, CONNECTICUT ALPHA-BETA FLOOR SCAN SURVEY RESULTS Legend Area of Elevated Gamma Activity Floor Scan Results (Alpha + Beta dpm/100 cm2)
< 99.9 100 - 2,499.9 2,500 - 4,999.9
> 5,000 Building 3H Building 6H
")
Building Columns Note: Survey performed with Ludlum 2360/ 43-37. All measurements are 1-min integrated scans. Survey results represent the centroid of the area scanned during the 1-min interval.
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SPRINKLER CONTROL OPEN PIPE GAS VALVE FARMINGTON CANAL GREENWAY SHELTON AVENUE BUILDING 3H SLAB, FOUNDATION, AND SOIL REMOVAL COMPLETE N8 N7 N6 N5 N4 S8 S7 S6 S5 S4 BUILDING 6H WEST BUILDING 6H EAST FIGURE SLAB SAMPLE LAYOUT FORMER UNITED NUCLEAR CORPORATION FACILITY 71 SHELTON AVENUE NEW HAVEN, CONNECTICUT B7 CITY: SYRACUSE, NY DIV/GROUP: EBC-IM/DV DB: L.POSENAUER PM/TM: R.GIAMPAOLO LYR:(Opt)ON=*;OFF=*REF*
C:\\Users\\ssteele\\BIM 360\\Arcadis\\ANA - GE CORP ENV PROG\\Project Files\\GE UNC NEW HAVEN - ENGINEERING\\2020\\30006255\\01-DWG\\GE-UNC_SITE SAMPLE LAYOUTdwg.dwg LAYOUT: B7 SAVED: 4/23/2020 12:52 PM ACADVER: 23.0S (LMS TECH) PAGESETUP: ---- PLOTSTYLETABLE:
ACAD.CTB PLOTTED: 4/23/2020 3:40 PM BY: STEELE, SAM N8
Arcadis U.S., Inc.
One Lincoln Center 110 West Fayette Street Suite 300 Syracuse, New York 13202 Tel 315 446 9120 Fax 315 449 0017 www.arcadis.com