4 D

G e

J PROPOSED ANO-l TECHNICAL SPECIFICATION CHANGES I

l 9609100399 960823 PDR ADOCK 05000313 PDR

a 4.2.3 The structural integrity of the reactor coolant system boundary shall be maintained at the level required by the original acceptance standards throughout the life of the station.

Any

~

~

evidence, as a result of the tests outlined in Table IS-261 of Section XI of the code, that defects have developed or grown, shall be investigated.

4.2.4 To assure the structural integrity of the reactor internals throughout the life of the unit, the two sets of main internals bolts (connecting the core barrel to the core support, shield and to the 'ower grid cylinder) shall remain in place and under This will be verified by visual inspection to determine i

ten' n.

that the welded bolt locking caps remain in place.

All locking caps will be inspected after hot functional testing and whenever the internals are removed from the vessel during a refueling or j

maintenance shutdown. The core barrel to core support shield l

caps will be inspected each refueling shutdown.

4.2.5 Sufficient records of each inspection shall be kept to allow comparison and evaluation of future inspections.

4.2.6 Surface and volumetric examination of the reactor coolant pump flywheels will be conducted coincident with refueling or maintenance shutdowns such that during 10 year intervals all four reactor coolant pump flywheels will be examined.

Such examinations will be performed to the extent possible through the access ports, i.e.,

those areas of the flywheel accessible without motor disassembly. The surface and volumetric examination may be accomplished by Acoustic Emission Examination as an initial examination method.

Should the results of the Acoustic Emission Examination indicate that additional examination is necessary to ensure the structural integrity of the flywheel, then other appropriate NDE methods will be performed on the area of concern.*

l Bases The surveillance program has been developed to comply with the applicable edition of Section XI and addenda of the IJME Boiler and Pressure Vessel Code, Inservice Inspection of Nuclear Reactor Coolant Systems, as required by 10CFR50.55a, to the extent practicable within limitations of design, geometry and materials of construction.

For reactor coolant pumps P32A, P32B, and P32C, the surface and volumetric examinations of the flywheels may be extended through the IR14 refueling outage.

l Amendment No. M, M, M, M, M,98, 77 f

1.

l i

I 1

l l

l MARKUP OF CURRENT ANO-1 TECHNICAL SPECIFICATIONS (FOR INFORMATION ONLY) l 1

l

4.2.3 The structural integrity of the reactor coolant system boundary shall be maintained at the level required by the original acceptance standards throughout the life of the station. Any evidence, as a result of the tests outlined in Table IS-261 of

)

^* ' '

Section XI of the code, that defects have developed or grown, shall be investigated.

4.2.4 To assure the structural integrity of the reactor internals throughout the life of the unit, the two sets of main internals bolts (connecting the core barrel to the core support, shield and to the lower grid cylinder) shall remain in place and under

[

tension. This will be verified by visual inspection to determine I

that-the welded bolt locking caps remain in place. All locking I

caps will be inspected after hot functional testing and whenever the internals are removed from the vessel during a refueling or maintenance shutdown. The core barrel to core support shield j

caps will be inspected each refueling shutdown.

)

4.2.5 Sufficient records of each inspection shall be kept to allow comparison and evaluation of future inspections.

4.2.6 Surface and volumetric examination of the reactor coolant pump flywheels will be conducted coincident with refueling or maintenance shutdowns such that during 10 year intervals all four reactor coolant pump flywheels will be examined.

Such examinations will be performed to the extent possible through the l

access ports, i.e.,

those areas of the flywheel accessible without motor disassembly. The surface and volumetric examination may be accomplished by Acoustic Emission Examination as an initial examination method. Should the results of the Acoustic Emission Examination indicate that additional examination is necessary to ensure the structural integrity of the flywheel, then other appropriate NDE methods will be performed on the area of concern.*

l l

Bases The surveillance program has been developed to comply with the applicable j

edition of Section XI and addenda of the ASME Boiler and Pressure Vessel Code, Inservice Inspection of Nuclear Reactor Coolant Systens, as required by 10CFR50.55a, to the extent practicable within limitations of design, geometry and materials of construction.

l l

}

i.

l For reactor coolant pumps P32A, P32B, and P32C, the surface and volumetric examinations of the flywheels may be extended throuoh the 1R14 refuelino i

outace.

i;-