Application for Amend to License NPF-8,requesting Deletion of References to Cycle Specific L* Criteria
ML20117G291
Person / Time
Site: Farley 
Issue date: 08/30/1996
From: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20117G292 List:
References
NUDOCS 9609050104
Download: ML20117G291 (2)


Text

'~~

Southirn Nuciatr OperatinD Company Post Office Box 1295 Birmingham. Alabama 35201 Telephone (205) 669 5131 Southern Nudear Operating Company o.ve morey Vice President Farley Project the southem electnc system August 30, l'J96 Docket No.:

50-364 10 CFR 50.90 t

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Joseph M. Farley Nuclear Plant - Unit 2 Deletion of Cycle Snecific L* Amendment Ladies and Gentlemen:

By letter dated May 20,1996, the NRC issued amendment i10 to the Farley Unit 2 Technical l

Specifications. The amendment allowed steam generator tubes to remain in service with bands of axial degradation in the tube sheet region for the remainder of Cycle 11 provided suflicient non-degraded tubing remained to satisfy the L*-type criteria restrictions. Since the amendment was cycle-specific for Cycle 11 only, an administrative change to the Farley Unit 2 Technical Specifications is proposed to delete the references to the L* criteria.

Currently, the following Farley Unit 2 Technical Specification amendment requests have been submitted to the NRC Staff:

1. F* Repair Criteria SNC letter dated April 22,1996 as revised by letter dated May 3,1996
2. L' Repair Criteria SNC letter dated April 22,1996 Note: A current RAI will require revision to the proposed technical specification pages.
3. ODSCC Alternate Repair SNC letter dated March 29,1996 Criteria
4. Elevated Tube Sheet Sleeve SNC letter dated August 23,1996 i

The changed technical specification pages forwarded with the proposed amendments listed above will replace the cycle-specific L* associated technical specification pages. It is i

requested that these amendments, if approved, be issued with an effective date of the beginning of the Farley Unit 2 eleventh refueling outage, or its date ofissuance, whichever is later. As these four amendments are issued, the references to the cycle-specific L* criteria will be removed.

O 9609050104 960830 PDR ADOCK 05000364

(

P PDR g

_.~_ _-__..

4 t

U. S. Nuclear Regulatory Commission Page 2 i

For reference, pen and ink mark-ups for deletion of the cycle-specific L* are attached.

Annotated at the bottom right hand corner are the technical specification amendment requests that will replace those pages.

1 If there are any questions, please advise.

i Respectfully submitted, SOUTHERN NUCLEAR OPERATING COMPANY

?/

)77,

^

Dave Morey REM / cit:T.cPAGES. DOC Attachment I