USI A-46/IPEEE,Outlier Resolution & Detailed HCLPF for Tank FW-19
ML20117A579
Person / Time
Site: Fort Calhoun 
Issue date: 01/19/1994
From: Karavoussianis
SARGENT & LUNDY, INC.
To:
Shared Package
ML20117A383 List:
References
REF-GTECI-A-46, REF-GTECI-SC, TASK-A-46, TASK-OR 94C2857-C-008, 94C2857-C-008-R00, 94C2857-C-8, 94C2857-C-8-R, FC06319, FC6319, NUDOCS 9608260207
Download: ML20117A579 (30)


Text

CALCULATION COVER SHEET Calcuiation Pr piratisn, R; view CALCULATION NUMBER Cale. Page No.

/

and Approval FC(d63/9

  • TOTAL PAGES 2?+

o Fomi PED-OP-3.1 Form Page No.1 of 2 cA c.w:

S cOE O uwrEDcOE D RRE PRO'.

~

Calculation Cover Sheet 0 NON cOE

  • Short Term Cale: O YES

@ NO PED DEPARTMENT FfO CALCULATION TrrLE VENDOR CALC. NO. 9'/d2 FM 00 9 A -Vi /TPE E E,

ASI

} ya"g** u,tyg,, pg.pg. af g o g>~

ou rurg gtsccu ri p hdD DE 7/ht A O Mct fi' fsiC 74tVr fW-/9 a DBD NO-l ECN NO.

O OTHER

  • APPROVALS. SIGNATURE & DATE CONRRMATION SUPERSEDES
  • REQUIRED (v)

PREPARER (SiOATE(S)

REVIEWER (S)/DATE(S)

.REV.NO.

  • CALC.NO.

RE A (S) l h II T. TS*~p

(

}

il//7/9y t zfsf9y

/ /.9 h

g p,'p' l

1 4

I i

a' i

i

  • EXTERNAL ORGANIZATION DIS 1TilBUT10N l COPY I COPY NAME & LOCATION l SENT NAME & LOCATION l SENT l (v)

I (V)

I I

I i

I 9608260207 960819 PDR ADOCK 05000285 P

PDR l

g

  • SEE INSTRUCTIONS ON REVERSE SDE o COMPLETED BY DOCUMENT CONTROL PED-OP-3.25 REV. 2

)

CALCULATION COVER SHEET Calculation Preparation, Review CALCULADON NUMBER Cale. Page No.

2 v/ 28 and Approval FC # 4I/7 Form PED-OP-3.1 Form Page No. 2 of 2 Calculation Cover Sheet FACILITY / SYSTEM KEYWORDo l

CALCULATIONS USED AS INPUT l

IN THE ANALYSIS EQUIPMENT TAGS l

CALC /REV. NO.

DEPT. NO. o SYSTEM ADDED DEPT.NO.

i i

fc&2Bfr fes. l f W-/1 i

Fc 62 91$

fe v. I i

f& #3$32 Re s. $

~

f c cp 3 6 3 4-ce<. $

1 f t $ 630 fes. h

.55 7 l

~

I i

1 I

I i

r PED-QP-3.27 REV.2

i 1

cacrarm 3 e'73 I CALCULATION RREPARATION, REVIEW AND APPROVAL-FORM PED-GP.-3.2 Form Page No.1 of1 CALCULATION NO.

PRODUCTION ENGINEERING DMSION F6 c4 4J/9 CALCULATION REVISION SHEET REV' NO.

DESCRIPTION / REASON FOR CHANGE O

O R rG i v/n

/gSa g l

I e

h i

l E

PED-QP-3.28

Pf6 E Yrf23 Calc Prtparation, Review and Approval PED-QP-3.5 Page 1 of 2 CALCULATION NUMBER Reviewer's Checklist-Calculations N </tEI9 YES NQ N/A 1.

Is Calculation Cover Sheet attached and completed, as required,to the calculation?

j i

i 2.

Is the calculation objective stated? Was this achieved?

j-3.

Are inputs correctly selected and incor-i, porated into the analysis?

j 4.

Have inputs and/or assumptions which require confirmation at a later data, been identified on the Calculation Cover Sheet and in the y

calculation body?

5.

Are the applicable codes, standards,

{

regulatory requirements, and other references including issue and addenda identified such f

that they are traceable to source document?

4 6.

Was an appropriate calculation method used?

/

Was the basic theory appropriate?

1 7.

Have assumptions been noted and justified?

/

8.

Are the calculations free of arithmetic

/

l errors?

9.

Is the calculation consistent with the f

design basis requirements?

j 10.

Is the conclusion stated?

11.

Is the calculation legible and suitable for

[

microfilming?

PED-QP-3.36 1

Pf4f

.C.',23

~

Calc Preparation, Review and Apprcval PED-QP-3.5 Page 2 of 2 CALCULATION NUMBER Reviewer's Checklist-Calculations f& hlst?

YES NQ N/A i

12.

Are all blocks on the Calculation Cover j

Sheet addressed correctly?

l 13.

Have Forms PED-QP-3.2, 3, 4 and 5 been used.

and correctly completed?

V 14.

If the calculation has been prepared to supersede another calculation, has all the valid information been transferred in the

/

new calculation?

15.

If the calculation determines that an existing or preexisting condition.may ba outside the design basis of the priant, are the results of a reportability evaluation performed in accordance with PED-QP-19 g[

attached?

REVIEWER CO M NTS:

T.s ;*in y T.s y

, t 3 r-fy Reviewer Date PED-QP-3.37 Rev. 3

FGM / g+ 2i

\\

Calc PrGparation, Review and Approval PED-QP-3.7 Page 1 of I CALCULATION NUMBER Independent Reviewer's Checklist - Calculations l

FC f l5/1 i

YES NQ N/A 1.

Are the calculation methods accurate 7

and appropriate?

2.

Are input data sufficiently detailed?

/ (aa. omm e.J hehow) j 3.

Are the calculation assumptions reasonable?

l l

4.

Has the basis for engineering judgement been included in the calculation, when f

used?

5.

Is the calculation documented sufficiently such that the analysis is understandable to someone competent in the discipline y

without recourse to the Preparer?

l 6.

Have the design interface requirements f

been satisfied?

i 7.

Are the results reasonable and do they y

resolve the calculation objective?

8.

If an alternate calculation was used to i

verify the adequacy of the analysis, is it i

attached to the calculation?

9.

If qualification testing was used to verify the adequacy of the analysis, has it been documented using a retrievable source, or 7

attached to the calculation?

10.

Are calculations involving Technical Specification values and associated margins y

of safety identified?

DEPENDENT REVIEWER COPNENTS:

a.n.P sts c 4 s p.c-trJ a.ec J ce d % % A 51 Mped av spec.h.

4 mA m)46d.2

<cmNs 1-s%, a0A..

4 A-A eM k in 4-S din uA.n m

A 9bb"

,d r\\

.W,,.ma

<-E - m /5 J

u' J/

J Am I I-m- 9+

  • ^.

w m

l Date' Independe % evieder f-f V

U PED-QP-3.40 l

Pcgs 7 of 23 Client:

Omaha Public Power District Calculation No.

94C2857-C-008

Title:

USl A-46 / IPEEE. Outlier Resolution and Detailed HCLPF for Tank FW-19 l

Project:

OPPD, Fort Calhoun Station Method:

Conventional Engineering Hand Calculations.

Acceptance Critena:

"A Methodology for Assessment of Nuclear Power Plant Seismic Margin" EPRI NP-6041, Revision 1, August 1991 Remarks:

REVISIONS No.

Description By Date Chk.

Date ApA Date 0

Initiallssue

,f./

il////ff 7MT /YT/

["/9'N

(/ O CALCULATION CONTRACT NO.

I COVER SHa 94C2857 l

FIGURE 1.3 stevenson & Asaxate.

JOB NO. 94C2857 C lculati:n C-008 Shtst 8 of 23

SUBJECT:

Fort Calhoun Station Date: 11/17/94 USI A-46/IPEEE Seismic Evaluation l

Project evision 0 STEVENSON & ASSOCIATES A-46 Outlier Resolution and By: A. Karavoussianis a structural-mechanical consulting engineering firm Detailed HCLPF for Tank FW-19 Check: T. Tseng l

Table of Contents Objective.

9 Analytical Approach.

9 References..

10 Summary..

11 Calculation..

1?

l l

l l

i JOB NO. 94C2857 C:;lcul:ti::n C-008 Shut 9 of.Z.7

SUBJECT:

Fert Calhoun Station Date: 11/17/94 USI A-46/IPEEE Seismic Evaluation Project Revision 0 STEVENSON & ASSOCIATES 1

A-46 Outlier Resolution and By: A. Karavoussianis con i ing e g neer n fm Deiclied HCLPF for Tank FW-19 Check: T. Tseng l

l Objective The anchorage for the Emergency Feedwater Tank. FW-19, is an outlier due to its overhan; l

according to the GIP (ref.1) screening guidelines. The first objective of this calculation is to resolve the tank's A-46 outlier issue, by means of conventional engineering calculations.

Also, the Seismic Review Team (SRT) performed an on site inspection of the tank and judged that the HCLPF is governed by the tank's supporting system. Hence, this calculation will 84 document a detailed anchorage HCLPFs4 for the tank and propose a possible solution to attain a 0.3G HCLPFs4,if necessary.

Analytical Approach The tank is supported on four saddles, which are spaced 14' apart. Two of the tank saddle are l

longitudinally braced and tne other two are slotted.

The tank's HCLPFs4 will be calculated by computing the factor required to scale the seismic loads to the upper limit of the anchorage capacity. Then, this factor will be multiplied by the design basis earthquake peak ground acceleration (i.e. 0.17G), thus yielding the tank's l

HCLPFe4 The spectral accelerations used in the both the outlier resolution and HCLPFs4 analysis are as computed in reference 5.

Also, the concrete used for anchorage has a minimum 28 day compressive capacity of 4000 psi according to reference 6.

l l

l JOB NO. 94C2857 C:lculati:n C-008 Sh::t 10 of 23

SUBJECT:

Fcrt Crlh un Stati n Date: 11/17/94 l

USI A-46/IPEEE Seismic Evaluation Revision 0 Project STEVENSON & ASSOCIATES A-46 Outlier Resolution and By: A. Karavoussianis Detailed HCLPF for Tank FW-19 cons I ing e g neer n fm Check: T. Tseng References

1. " Generic implementation Procedure for Seismic Verification of Nuclear Plant Equipment", Revision 2,6/28/91.
2. " Seismic Verification of Nuclear Plant Equipment Anchorage (Revision 1), Vol. 4:

Guidelines on Tanks and Heat Exchangers", EPRI NP-5228-SL, June 1991.

3. "ACI Building Code", ACl-318-63, Section 1801.
4. " Emergency Feedwater Tank", Eaton Metal Dwg. 80048, OPPD file #02377, S&A ref.94C2857-DC-19.
5. "lPEEE and A-46 Seismic Review FRS", Stevenson and Associates (S&A),

Calculation Number 93C2777-C-001, Revision 0, OPPD Calc. FC06323, Rev. O.

6. " Design Compressive Strength of Concrete at Ft. Calhoun", R. E. Lewis of OPPD, ~

September 16,1993, S&A ref. 93C2777-LRCO-047.

7. " Auxiliary Building Equip. Supports, Outline 8 Reinforcement Sheet 2", Omaha Public Power District, Dwg. # 11405-S-69.
8. " Auxiliary Building Equip. Supports, Outline 8 Reinforcement Sheet 3", Omaha Public Power District, Dwg. # 11405-S-70.
9. " Tank and Saddle Stiffening Rings", Eaton Metal Dwg. 70-272-E2, OPPD file
  1. 02139, S&A ref.94C2857-DC-20.
10. " Manual of Steel Construction, Allowable Stress Design", 9th Edition American Institute of Steel Construction Inc.,1989.
11. " Seismic Verification of Nuclear Plant Equipment Anchorage (Revision 1), Vol.1:

Development of Anchorage Guidelines", EPRI NP-5228-SL, June 1991.

12. "CQE Piping Isometrics, Seismic Sub. System #FW-349A", D-4109 Sh.1 of 1, S&A i

l ref. 93C2857-DC-046.

13. Equipment Nozzle Load Summary Sheet", OPPD Calc. FC02865, Commonwealth Assoc. Filing Code 254-CS-10-001, S&A ref. 93C2857-DC-046a.

1 l

JOB NO. 94C2857 Cricultti:n C-008

SUBJECT:

Fort Calhoun Station Shs t 11 of 2. 3 USl A-46/IPEEE Seismic Evaluation Date: 11/17/94 Project Revision 0-STEVENSON & ASSOCIATES A 46 Outiler Resolution and By: A. Karavoussianis cons ing e g neenn fm Detailed HCLPF for Tank FW-19 Check: T. Tseng

14. *COE Piping Isometrics, Seismic Sub. System #FW-348A", D-4240 Sh. 2 of 2, S&A ref. 93'"l2857-DC-047.
15. "Equipmant Nonle Load Summary Sheet", OPPD Calc. FC02800, Commonwealth Assoc. Filing Code 253-FW-10-007, S&A ref. 93C2857-DC-047a.
16. "CQE Piping Isometrics, Seismic Sub. System #FW-346A", D-4239 Sh.1 of 1, S&A ref. 93C2857-DC-048.
17. " Equipment Nonle Load Summary Sheet", OPPD Calc. FC03032, Commonwealth Assoc. Fi!!ng Code 253-FW-10-008, S&A ref. 93C2857-DC-048a.
18. "COE Piping Isometrics, Seismic Sub. System #FW-396A", D-4241, S&A ref.

93C2857-DC-049.

19. " Equipment Nonle Load Summary Sheet", OPPD Calc. FC03037, Commonwealth -

Assoc. Filing Code 253-FW-10-009, S&A ref. 93C2857-DC-049a.

Summary This calculation showed that the tank's anchorage meets the A-46 requirements which are set forth but the GlP (ref.1), hence resolving the A-46 outlier issue. Also, this calculation attained a tank HCLPF84 of 0.39G which was govemed by the braced saddles.

l l

l

1 l

C-008

'l og 7g CUENT JOB No.

met 7 A

N n/iW9Y V v//.A ix r tz/r/9v T

A-46 Outlier Resolution and lN Stevenson nad Assocates Detailed HCLPF for Tank FW-19 V

a c.^.'":,'nt"."."t.'7.'.

h

,///.

-. 1y Pit 7,, _ pff 'tQ __ _ }gy _f)__

_ _ _ _ _p_~

G,f '

1.

..yggy

.S < t 7 f

) =

SO

( 4 - ? vrt' )__.--.__ _ - _ _ _..

.- _ -. -. --. __ _11_ / "

_I _

'?fp o 4

_ Vo 4,_c.~.__,r_91.op _ L pt.

=

___N.u_.7. dAYY## ll5 S*N# WP900 4 5 L. /'.G. C..

> ES' ne f

~

=

J.4-

/O S "

bJ 0 ' K' 9'

I)Y

-. _J 4. cot. L S

  • 5:

/V' 4_~_.27 "

d*. ]l. 5' r ' O (P i t_

0

- -.-.- --_. - S. ~.. l f. X ! 0 f S.'__

Y Q.A5 6 b 4 f5+$ 5

/"

(v

. ~5]_ks l s

+c f/d "

\\

ej - T "

i 7 l 9.

__Bo.t rJ

  • 2~-

~2_B o c f S.*

i

_ d.__ _

rey __e Rt 7E :

10 ' = Vo *

  • P.c s l

I l

l EN7 C-008 if cuenT ace no.

e og 27 A

sua; sci N /.l /'

u//7/9Y

=

Y 1'M 7 n-tr/f u T

A-46 Outlier Resolution and lN Savemm ed Assmaus Detailed HCLPF for Tank FW-19 V

m\\

m c.a.s.e.,...i.u.

h,..,.4..

f

. /t t N

. _...-. 3 // *)D C f- _ __.... _ _.... -._.

l CLs/LA.2' f'Lf edon' f M p KS _ r w he ~'... 8 Y t

- /6 LVD'.$ L k 4 _ M S Abf.L[S_

W&'K ? Mf w fe o Eb l

l

  • 70 _G//

f Y/ N / " d d'f.

_,,., =

-. 3...

~

3-

. g _u.-.

_4

/

h _, e._ ___

b P'

Y_., _Y.

$fl$ OVI ifh'$) T /0 f. [~ i.<

('rypff tr'd n V(v.,5e y 1 Y_ u s _, n _ _.,- Sn.r._21 z..? .-.1 u

2-t

= f~p 1._ $,._.? =*__2. 0 L v I M A? ' Ax ~ 'l V._Vy_2 !1 < %_i.l _. _ -. l ' ?l_,,,,}..-. 2 1.U Y.]v Y..( r !W*. )) l.S! *.51.')1DO V'"T " . _.D - H = 2700 1_e. ' . _.. _.. _..-... h r i ~ ~ ~ l '/[ = V /. /_w ~~ r = u l 4 lM' . f fl'/V 5 $7in k l l . WYO $ h4 L. Y kl$OWh t"d $-BstYS_ _fe' .2 11. 'fo 144 L / s,c,t y =_ 1 ' - 3 - 3 q "~ ~ ~ ~ ~~~~ r - e rp >u n r = ,9-y * -- 3 s I e {

r 9 C* 8 l'/ OF E7 CUENT JOB No. SHEET l A NAF it// pay \\ V 7Pf*T r1-/thv i 'T A-46 Outlier Resolution and l Stevenson and Assmates Detailed HCLPF for Tank FW-19 5 l n c.t.'::nt".2.";L y waaa__uu 2 w?--.n.r.a.~ m %.?eut-Y,1 AJ t.1 w A g / d E_pf_ap___ dt'(f= kl S.O h000 f

~.Np.U C&W

._ ?.E.1. 6a (t)( T_) S I)i l h 5/A A s = w -a 66 -_+wa .w.e e y -i es.gw. gis. /* e e c : 11 1 ? !N - 7__J._._4. _? " _.. _. _.. _ _ ) ...-_xou,_ucc parc.. tE~~ ._ 2 -. -.. ~ _..,.. 7 : -.O .. _. -_A . _.., 2 : A a ...------...<,.- f p.-. ,4 --. -- L g -- Yb. __f o 1S/Rrifn' A ] [~ 2-

  • 4IT

. E 1,..! ^---, L festl l 0= Ukt. =.. 2ff_k si._<-. /.1 h'}.H. =.- U Fr tsc. h .ee -Mw., sm-r alue.pp. em.. R w fgg(1)(-se,6 60).. - =.1J.X ? / 0 l ./.. -zKc c-r wt< o :

ny 10 0

.W]l' O. v ~ / 4.C. . /vo 7 & 0 V6Ad-_. uw .t N d.im e .e mil g M. .m Tf.pn g f= t/t

  • w : $_f >

10.1_ { "

._ &_.L I

i / I* . [D.4L.D LC.2dd.f : ~f//C_. M#~tw4 - 5 1/o v ~7//6 . f's$0 ' * ~ -- h.? \\ ff w fe d&Ln - 4.1u12.Lff- _FLe0/L.J1t?O-. BL.A.M. - h/ 0,. hkf) /$ n WL 'l Y 'Y/ll[ kWh f.__l_&__ $([ ~7J// ; f Y Yf k kk l he fa kM l} &__&_h e Ut r. e f, f//t= 1 M o it r ' P4p Guo Mrgy y' R Et w itistc f m ( W 7 4

94C2857 C-008 /( 2.7 l cuan m. e og g suamer i \\ / f. //////W 0

  • / 7u7 evr/w l

T A-46 Outlier Resolution and lN stevenson and Associates Detailed HCLPF for Tank FW-19 V) l E c.^.".7.Taf07/A-ez .--._.W/4L . -. ?PC.k1A5._ Y.U_W_._ A AM.O NA.M...C#f r@ . ~. .._._ fA A.T f_f d d. _ A [NL d_f_W_A L.7 d __ d 4 49 e /? _.[/b/4*dfd;?A6" fDKf._ DAS 4 f.E _ G_E_ d.K c h o " Ye_ _Y_ /Y D w/7 El e o k_SL 9 f n.r o ~ 1 . A I 3 l**1?S -- O - __ I L4 l 4L ~~ l j i .. _. ?JCW &c/ / w Me 7WM v H 5 6 (w-t)A~0 v/t fa 44 pdft%) f =f/'~?fl.x))/_iY.9it.- HAl.? fM' fML <f._ K+] M 4. ~ '6'7H X '_-.a - co rr w d n t _. _. :Anat c r flMJ ~ & = _.. _w R % d_._. _a_v.cs 2 sxa.n. itis -. h 4 _..cao e i ~4 of... i =lh_.1(Ij]/t L!ff -.. = ...-. - _ E t_2 tr u.'es i =. Y / K r/* 7.,mL ..,.(, y,3J. L 2. . }.__ f.1._ G __ y y[_ f.; r = g-].Mh..-._ 82 ? TW .... N _. ~ ~ ~ ll?[?I5)l /Mf9 5' t= r 4 _. c. i> y rrsytat)(sonytzt.i) )) { ~//of d) / :7/)'f- '~- 7 i _7 i ..w. ep .es.. -pe. $ JN_t: /S. - [N.{_.NO /s!tD.Dcd. C_dfiDL.ES-..ARE I f?KAL.f.0-.. liv &C 4 0 ~'41.7112/u A L p / A 6.4Z.to W wTA f- / C f/ f frv f $_$ W/LL. fow<tc'f /J f 0.42.Z(/ fWA/H f l Awa BA' /k i sv 4 A c 770w'- I l l

i 94C2857 C-008 /6 7J cuar. m. e og l A sta:tcr l L N // /I P/9V i VO TM7 in/r/n T A-46 Outlier Resolution and lN l st=ran and ^=mata Detailed HCLPF for Tank FW-19 V m\\ E c.a s..~. m...,.,.. ,e p t l'. ~~ _.. _. _._ ( a a_A r 6 G w M 4 / v u e ~ c.:t'_.z_e.41_A. .). _. _ ~ ~ ~ ~ ^ ~ ~ ~ ~ .N,.- . hig'~~ [.31g. 3 7,,,, y... sC vc - 5 Ei. [. / / ". h L,.'! l]E,Vi.'.ylif '

q f g [

r ~ ~ ~

L 4.s-C.=.hrnhar ' = ! ?o. m

^'~ - -.. - _....... _.. E. 'L. b D -. ~ ?.o?. ~ l97 E$9-fPV V7: ~ !. 9f.~$ foot 4enti .p.y..__._._ PfIABS-- Sf I H s--o P- * ? I

  • f M'S f,5; g ;(, 4 7 g,,-s; TAl'f.P"( IL s u!.c.c.kU/0" P:

= L l

v

~ ._D.f G&ltv6 k~g_= f/.l.$ X /! 'N/ru - l ~ _... I A4M - k_.s ~. y.f_3).[ g.. __.7/2)fr 9mt).[425) p ~'~ 2?' Ye * .1:$.))2 X'# g,f k' r. : r;.,' Kp- -= lbk./ Vi e. ,h- [ /% C O - 70' %' /?./].t_vfC_ rS >}.1 #s n, /.). VHu tr i C fHr fort._o wsw T'% nquffo .rftfle,9 e f l NCfCffArt.2w ffon fAlf AMX/lll2A Y-- A L<14*DJ " & Af f? f h / 01/. 9 S* ' l J- = n: 7f /:' O 1/. '/ //p i 'O f I he f kb f f(a $$^ l _/ i ,r 0. l 7 2. 6: // t ri sO '

i l l

i 94C2857

m. _ C-008 mar

/> 77 cueur or N /), V. II/7W9Y V TM7 t1/r/1y T A-46 Outlier Resolution and !N stmw=u1 Ana== Detailed HCLPF for Tank FW-19 V W c.^ t J" iO".".7/.',- -y

  • Tf / /

LLtX m ie i e A D.s p u t. 10. _._ t // f ZEfC1/MC.. ACC 4.L fit 8.22PM__ 8ttf.: _.k \\ \\ __N_ q. FC = 6o'/ Boo _x_p.g~=l]iW2 6 /& F**rk P = 6p1 R9 0 K 0: 1_L _./_B ?.YES Ile ? F,y = _ _ - _ _.. _.. _ _. e 9 f o Y F o o

  • o. *! L _ ~- /I3 W A fAc

\\ v o_ :? Pc d c o nos

  • b 77 '/0~

[ l ( l$' foca sw JLs._ __ _ fN h -,-N_ I A ~ / r._je i _ rno_ne.,-r.r I -1 o @r 4r ue2r_c_?_f ns t to _p2/1tdZt.e4_. Wf/41/1_. A-.'74'f'~ sc. w !?c t fx jf._ __ h Mr M ~f A_t_ __.-- Cf I2C - S;2 ._IY8 JV// _f_Zj_2 9/1 YS/W4'[. ' 7R ~ Kr6 ns~__._ 2t1._-srs- _3ou ._as o _171 L.__ 2f~ c'7 -f V -7 .r2 B w/'/ Jo 91 V0f/4f. 40.de$ / .0 -IA -//f /61*l 0 0 ') (~ O' -18 -/6 r 2991 0; O }} U LfCC' 1 $1 fp18(,J. Ltd '/fd " '/f.f Tfd'l lo fli CIT 8~ y//syi / - t n A.p r 4r w eepc E S D_uf 70 O_Rf d_f th!k__.((11hc 1 l_pffN_f$NGWW M fiti fr ff ff I'1r F1Y M l l rr i vti er in spov

2 w1.

nu MME ) THEL' Xfb 2/21' fHB 2 06; !I'/11 ! '91f TW10 X f ro, f 19 ! Yt $ 5~/ 8 flB Y [ $1$ Qu.Qf_f, f * (V { I g cf t f i f,,

1. Lf.

f 2y f gj 2 :71 0 j 'Tf 14' f6 !! l ^ !! 60 t ~f 6 2 *18 . Y_/\\/ /S 8-i I (RS5i I7 /t 9 fos iS B 7WI cit tf f J& v0 KC 5. l

94C2857 C-008 /9 a cutur m m. e og suamcT N W/?/W V A.? 7~M *T t'z/f/w T A-46 Outiler Resolution and lN l Suv=n =5 ^==*** Detailed HCLPF for Tank FW-19 V) E cA..'.'.Oi'.'t.O*.7/1. lif;,$ - t am me tre r ons-4 -r rue . 4 ~ ~ as. _. l Df da w_fj_4jff: S i ngf_, 7N( y k g__jg_ __p? h,_p_,_u_ f n s r/J TNL vf t rir sfr /fo-p -rtde_1_yf st ri B A ffft fwg Co f& viit 7ff_/L AuD__7_p_oyelvisjg J i AQ w / t_C ff r &iwt Y Djs7 pts _u1/p // t n ivl, -7 H E W _nff o A_L[.,._. __..._.. ___ ~ _. _ ~~ - g o v. y f pa : _ 4 = -/(L,__?JoPS y 'W' ~?~ v f r rie ni r riew,- fym = t L_y_ _ g, g (!) r & () f., =

  • t ----.n y.-vvy^ = Yl. thar tags vrp e r ! auto v

= I i } I Q,,_=__'lL9k.rs (?) N. Q^_r?.hc %,1_. t6,9__.F_i,auaa d) eT l 0 N f- ) 7la n1N Af } bkO$ kWu_g / Y A$ Af Y"}} [ [ f f fQ i R7'/ C s Afff. f $ 44 l'fd!L Tf 7b l / I f F. I M = W 88/gJur ' N / c...- l '/v" X /f ] [ h i [.?, TF's r fl) ? 5 L -- # = e o i Fy,, 'i,rm 1 /. e 9 e s t = // r J r g ,I I [44 i 4 { bl I ! . pl + > kl h l i. i ; At i i i i i ,'I i l W l l l [

94C2857 C-008 CUENT y. e i9 or 7.7 NV 'N. k IV/W94 7M7 hit-hv T A-46 Outlier Resolution and Vl N Stevenson and Assmates Detailed HCLPF for Tank FW-19 E cl.*2'?iO"!!n ) .pf -._are r. rac 4~e n a a r. of. mr .rc o rreo ran c.c. .r~ w s r a/ A v i I ! H L /1.R V= ' '/_W_ "+-_.. _ _ __ _ _.. _ U ?]).jst lKo u 7_j \\ m ele l _.h _ ..___.f((Q).* {_ 2,5g i _Q Pu u pp t : P: V i s. _E.- -. ' nzsizl_._f.. i_/ _.... yg g-91A --l q L~ --~~~--t 't __.s.__...._ v. P* /_d_a_,? _12, A _ =_ _? A_C ! > x \\ C> M i ^'o sd?C i fL.._ f* n-.A"VS ~ n~a V: ll ?? &.ip .r3_, _Y k a's awe H p,e At:f_. i r s. 2-(p tr //...Y{ /ss u f'. _ _ _ _c.r_~ c r u d ZL v A / s rch u prs'i~& r o n_cie= 7 ^* ?*; :ME (/( 2x .i?.--B ) %,ji74 1_ i ~~ ' ~ 7 __ _., _,g p n 't M /$( fi(Ap_!L,'_.x.;_J.,_f_ _ ~.... l ~ p/d' / Pf "f: ? f D;I? : 0. T 'f( ~5&f.', c4 l-; rWek rar st uo,e nx e os ryr u ne to usars - k' 4 l 5 cup 4xr

  • 26 7 1

%m i </. VK 1 nu n r w is.rsetz-.1e w m ~%_5

l

~q ne w-m. 5i /Y fa e f $t - < o. / YJ f ; O " \\ ,t l 1 .~ ,~ 5 I fB = WP o.v2 9 f t e n s = j h :_ . /..c : /)' =,_!.?/ =. a. 9, v / J ", i -o--<.,, s l 8 8 I A/l p y -1(18 4 t Mft f 90 fc ** /7/ f )= YI2/ l} n i

I 94C2857 C-008 curer m. - 20 or 7 7 k V

p. t.

N it/i?/e./ 7717tuc% 'I A-46 Outlier Resolution and lN V> Stevenson and Assmates Detailed HCLPF for Tank FW-19 ,..::=w:.=:a. f --.--_c 4(t._ r"f44 V' _ __.=...lyS)

  • k,y pl1

,.,f.a _kpb, t-._ - _ _ll U ?_ 'f Y = l pu ants 4 .. s..M_ g _ t _.. __.4 ___ _ - .___..._..l&m 1_* L.* hat 0"r* _f._=. l f~ -91??-- fr ?tt4 V * {^&_*-Ot-- ~. f -. in:r - - - 1 .i i b .//.5. _ _!!:.?~-. ?$.?l._? $ ? ' ko.uruf15. -. f.e a 4 -N4-e swcf V=/ W _ ret t V4a _ ~ G 'I k er _ ~ l AWc#endst is

o. k.

fe n d..Y/ ic ru E. _ /5.[vl rN l~ l __]L_. IV. W x - / E f.)_ l_ _ ( 7 3. t / \\.f1 'l l ~ l n uiji L M n.;;_ j w. = 1 !B 1. -l,_ -.. llf_d. EF =.1.6 9 x _e.12. =- / 56 A. ? 0 M O<f-fHfck .reso&E /)<o Br4cint; snfep fe.S i Cr et.L_.. Re.t/l._.7tff.._Ed??LfS.. 55b M4&rW4..'".Ct?Lf/: l I i wgy -rog f.z a Ltt-._j y -nit t.o_xu 7e_pw.A.1218fntn"'; P R 6 L./_etL._ew2"SfR wac A'f_S.L $_Y YM 1 .wtHrw' fu f>, V 2 2L_72f_-ams ^ = H 2. 9 kter- = p I [O W[/O SA YN! / O kO' /SI _f $y.}}((f h/$Y$/ A Q_Y_/O i l l nonerv ret rs-ow I comnsaw mtmecn 1 \\ ( l i 'ff4 =:.7 9. 5 },,,< / ' urm e r/2 \\ t l - - r-- i I 4 i i : i ii;

C-008 o,., 21 mogy 2/ CUENT JOB No. A N #.A ///h/9'/ - V 7Pf1 s t/rn u 1 T A-46 Outlier Resolution and b

  • -n and A=****

Detailed HCLPF for Tank FW-19 V E c.t.'Jit:;7.'.".""t."/L ^ Y l ~ r * [r!/St.. 4. '$ P1 de191K *. arf D,LL 7, S* l Yu' * /W ' _../??./..".fte~sto} .l= r I ~ 4 = 1.2 9 r- ? b!!.Y.._N-N. _ _ r-t yy - 7.'//.. Jr * / e -- ;- x 2 $ ~ 36,2 " )._ .y.y.1.17 7.: yc -- k tys. fh1 g c ;,y :----r or. 2 -- -.f/ M e_. s -,c --71 c J'"? c ,'- - r,y _ -. y -- es3 ~- eu -.e et.g__ h Fo = /L]1 re -. .m_u_.iesww GAlb 5i C2. 1.f_LS'"!c AD. t/M N iiS w. $ ~~ J.L J_"f 11 l 9'* 'f*'.* # fl *' .c = {fT/ca, y y 4 = vo. gf z., a A = h 9 R Sn' 'f x o. l? =- ), o [

p. b. 74.. 5

~ ~ ~ /Mt PF = __.D o pe r l -rsit rwo sa g_ro e A r>ns6 w u c. __g L cirr, i ,21. B- /S?. 9 lC */ k -ii* i a.i f as?e g _ _ j)t._.7/ o ~< = A y = 4(6C4'){2 @ = B.f.D_E_.p_ m _ fo wr,.) LLk Mw_ "i 9-9 01 4 k.,a - o n .<5 d ./ f 7 1' '//. 4 ' f 1,* t ! ai 4, e/5 7 r l f x.

  • i

~ 1)).9' k ok S. = ~ / i i I Av.~ l t'"I.. L i + J 31.1 % cI IT *'-- 2/U.1 lc osc. I ~ ( i 'I' i i I i i i l

1 94C2857 C-008 cuan m. m 7 2. or 77 1 N 4 E. ///n/W V 7H7 JuMv 'I A.46 Outlier Resolution and lN V) steve =n and A=mata Detailed HCLPF for Tank FW-19 a c.^,.t::;' it,*.O.,,.'.. . (!JL-J. _ 7_ us.Le4 /, ?

  • 4He Au o~ M d_

Exc.4'1 .ru r. f ,0 ! !.0... GkA U /W YW.S / l$$ 9 caua: f, = ' 2 = ',,g,_y o. tri r i._ _ftin) r:r =- z ..i.! f> = W "' W = %_l I rsi n ,p c ../, = I

l. ? w o-v 1 B.- 2 L E_ K r '

r S" Q&'. = o_. tLF ) E.S ? ?n~ f 2 9 ^ ~ 7' % = 29-1% = 2 0 v townaw : rth r d,a c. i1- '2 u/ k sa.. ry.. & =- --x- = l I i, ^^ . F = T.. l l = /Xz u r. - h b,_; Wr r ~ ./L? Ps' L._ = j F 1_.,1 h_,' rh.,' = J. i. c * < /.7 2 -= /2.- f /a. ' t fA=

1. 9; r saf % ; Tf *-

T L 7 2. Kr/ I } 1 l N..., +' $ ~;- o.VV' $_Lp i 6 4 -. & -Y/__., I k. l-/V! pf -. o -.I b.xY n:334 A_*T-f. p/t x Do cerc A26 6 L fc. i l i i I i. ( i l 1 ! l I l l i i ! l l l ! I t iI ! i e a l l

r 94C2857 C-008 CUENT m. e 21 71 og l A N 8.2 iW/?/W V 7wr iLifMv 1 l T A-46 Outlier Resolution and lN i st=n== and ^s==ates Detailed HCLPF for Tank FW-19 V E e!.::' i'::,""::il.., rp. l . ( WffW. - Ef /lC/% . & i f [.55 -- -e-.-- --.. m/, 1Hf, ~. _ -.,, {. S A ff O f_ __ _y i t 7' 't" = 21'~ 1 A t__f x 3A :.__ t i r, ~ \\ _g -.$_ _u L. h2c ' '.-..... - - -- fa fe is. 1 v t a r:J?%i:ong ~ ~ 11 7.- 1 1.~~-A M. ^ xm ,w e.4.e i 1= Y5.-26y* '/l./" _1 Tl K (LY R .,z1 -x L K._. A X ~_L.L ^ ] l . J o..-:.._. & = ' "' ' L.w = 62 cs.f 9y 1 . b = 10 J '/ ' Es c' ....fk 2 ;.] M n es ' 3 3 7 o.ip = a] 9 4_. > o x f f t. ton t f'6_rttf_Lvf) a l - ----[nf& K tu_fc djjv f, i Wf t'O ' BFrovr/w ' Pz Af6 ^o f' Ano esvggf} M o vi mig Vy $~/6 L E f 1 1 '" / PW/puf? ft 8hf,6/ Q $ h )(it)(9.? o4}( ro-C) : (29J1 re s I i a ((s.ysfA stn VA 4 l 1 i I f*Hf 7"/] vk ' M4s ' A WClFF of'- ~ ' .- r i & Sffi Du & ro! TWfa _c /]Dat.f < i I ! i ! i i t i i i,it

1 I i i l

1 1

EEP-36-2993 14:20 FROrt PED t4JCLEAR 'M-EP TO 916879334429 '. 01 f* P C Oi O 93C2777-i.RCO-047 @.]Q R mas 9 FAX COVER SHEET <n rlO 5?" $4 Date: i ~ M '93 z.s 1 To:. PAuc KAt?Avouss tai s StA 'il0 Telephone: FAN 4 / 7 -1 8 3 - 4 % 2,2 Z k e hk From: Od^'OY L6W /5 o FF.D D C $d Telephone:_ 401 -533 - 450B M k O COMMENTS:, Number of Pages to Follow: [o l O l l l s

~ ~ SEP-16-1993 14:21 FROr1 PED PLO.E.fR 7J-EP TO 916179334438 P.82,,.. -g a Date: September 16, 1993 Author: R. E. Lewis, P.E.

Subject:

Design Compressive Strength of Concrete at Ft. Calhoun

References:

1) Design Basis Document Containment, SDB-CONT-501, Rev. 5 2) Design, Basis Document Auxiliary Building, Rev. 5 SDB-AUX-502, As identified in the attached excerpts from Ref. 1 & 2, the normal weight concrete (designated as Class B), used throughout containment and the Auxiliary Building, was, required to have minimum 28 day compressive strength of 4000 psi. Nearly all a concrete anchorages are developed in this concrete. Heavy weight concrete shielding walls, was requ(designated as Class C), used for some ired to have a minimum 28 day compressive strength of 3000, psi. Some anchorage may be installed in this concrete. have a minimum 28 day compressive strength of 5000 psi. C Only a few anchors are installed in this concrete. Concrete floors, are generally conred a 2" topping of light weight concrete, sloped toward floor ains, having a tested-average 28 day strength of over 4000 psi.'

j SEP-16-1993 14883 FROM PED P4JCLEAR 7W-EP TO 916179334428 P.03 ~ -Y // I 1 1 i i l 1 l l l CHAEA FU3LIC POUIR DISTRICT FT. CAI.EOUR STATION DESIGN 3 ASIS DOCUMENT i C00tTAI!OGNT t DOCO G2tf NIRGER EDED-CONT-501 1 Revision 5 February 1993 CQE 1 e I i l I o I e t

// /' .SEP-16-1993 8G21 FROM PED 6 W D Contalasseet Ft. Calhoun Station SDRD-CONT-501 Omaha Public Power District Section 4 4.0 DESIGN REQUIREMENTS 6.1 SYSTIH DESIGN REQUIRD(ENTS 6 1.1 System General Desian RecuirGents 4 1.1.1 Layout Requirements The containment structure layout must include provisions to permit access to system components for maintenance repair refueling, and operation. Openings in the interior concrete walls and floors must be provided and grating used where possible, without reducing the necessary shielding, to allow depressurisation of all compartments in order t'o stinimize differentisi Design Basis Accidentpressure across the walls and floors due to a (DBA) (Ref. 1.2. Supplement 2. Question 10.1). 4.1.1.2 Environmental Conditions The containment structure. including access openings and i penatrations. and any necessary contafamant heat removal systems i shall be designed so that the containment structure can accommodate j without exceeding the design leakage rate the pressures and temperatures resulting from the largest credible energy release - following a loss-of-coolant accident (LOCA). including a considerable margin for effects frams metal-water or other chemical reactions that could occur as a consequence of failure of emergency core cooling systems (Ref. 21 criterion 49). 4.1.1.3 Material Requirements The requirements for structural materials used in the design of the containment structure are specified below. These requirements must be used when evaluating the effects of modifications on the existing containment structure. E Concrete Concrete used in the containssent structure is of three classifications. Class A. Class B. and Class C. Class A Concrete smet be used in the contAiament structure shall which comprises the cylindrical wall, spherical done, and the._ portion of the foundation mat beneath the containment structure. Class A concrete smet have a minisium 28 day compressive strength of 5.000 psi (Ref. 5.1. Page H2-4). 1 of 27 Revision 2 l Dates 1/92 a ) s 4 k

e SEP-16-1993 14822 FRD1 PED 6 W-EP m WSmWN M containment l Ft. Calhoua station SD&D-CONT-301 Caaha Public Power District Section 4 \\ Class a 4 coner,te_ saast be used for structures within the i containment structure and the access gallery beneath the containment foundation mat. Class 8 concrete must have a minimum 23 day compressive strength of 4.000 psi (Ref. 5.1. i Page H2-4). Class C Concrete _ t be used in localised portions of the must containment :tructure where special shielding provisions are 1 required. class c concrete must have a minimum 2s day compressive strength of 3.000 poi and a density of not less than 225 pounds per cubic foot (Ref. 3.1. Page H2-10) For locations of type C concrete see PLDAD-NU-63. Personnel Protection. i E Reinforcing steet Reinforcing steel in the portion of the mat beneath the j containment yield strength of 60.000 psi. structure shall conform to ASTM A432 with a min j 4 ,i Reinforcing steel in the balance of the structure must be intermediate grade deformed bars confoaming to ASTM A15 with a minimum yield strength of 40.000 poi (Ref. 5.1. Page H3-1). 3 f E 5 Welding of Reinforcing Steel Mechanical butt splices (other thaa lapped) must be provided by. means of the Cadweld process employing 'T* series connectors designed to develop the specified tensile strength of the j reinforcing steel. No individual splice shall have less than 125 percr.nt of the = hl=um yield strength of the bar being j spliced (Ref. 5.1. Pages 83-1 and H3-2). 3 E Structural Steel Members i Structural steel shapes and plates must conform to Astm A36 1 with a minimum yield strength of 36.000 psi (Ref. 3.1. Page i H7-L). i E Velding of Structural Steel 1 The welding of structural steel must be in compliance with AIsc )

  • Specification for Design.

Fabrication and Erection of Structural Steel Buildings" and AVS D1.0-40

  • Standard Code for Arc and Gas Welding in Building Construction (Ref. 5.1. Page 2

M7-2), a 4 2 of 27 Revision: 2 i Date: 1/92 h 1 1

SEP-16-1993 14:22 FRCM PED HJCLEm W TO 9161W D 4R P. E ig s l CHABA PUBLIC POWER DISTRICT FT. CALBOUN STATION ' DESIGN BASIS DoctMENT AUIILIARY BUILDING DOCUMENT NONSEE SDBD-AUX-502 i Revision 3 SDTEHREE 1993 CQE i i i e

ELP-16-1993 14:22 FROri FED RX2.ESR W TO Mamm P. M Auxiliary Building Ft. Calhoun Station I SDRD-AUX-501 Omaha Public Power District Section 4 4.1.1.3 Material Requirements The requirements for structural materials used design of the auxiliary building are specified below. in the original These requireawnts must be used when modifications on the existing auxiliary building structureevaluating the effects of Concrete Normal weight concrete (designated as class B) satst have a 28 day compressive strength of 4000 psi. Heavy concrete (designated as class C) density of 225 pcf (Ref. 5.1. Section

  • Concrete *).must have'a 28 d Velding of Structural Steel The welding of structural steel smet be in compliance with AWS D1.0-40 Standard Code for Arc and Gas Construction (Ref. 5.1. Section
  • structural Steel"). Welding in Building Welding of Reinforcing steel Mechanical buttsplices (other than lapped) must be provided by means of the Cadseld process employing
  • T*

series connectors designed to develop the specified tensile strength of the reinforcing steel.' No individual splice shall have less than 125 percent of the P M mum yield strength of the bar being spliced (Ref. 3.1. Section

  • Reinforcing Steel").

Reinforcing Steel Reinforcing steel must be intermediatein the auxiliary building saat and superstructure grade deformed bars with a minimum yield strength of 40.000 psi (Ref. 5.1. Section

  • Reinforcing Steel")

Structural steel Members structural steel shapes and plates must have a minimum yield strength of 36.000 poi (Ref. 5.1. Section ' Structural Steel"). Structural steel Bolting All field connections sause be made with high-strength steel bolts in friction type connections (Ref. 5 1. Section

  • Structural Steel
  • 6.02).

Spent Fuel Pool Liner The spent fuel pool liner material requirsaents of saast be compatible with the cooling. ED&D-AC-SFF-102 Spent Fuel storage and Fuel Pool 2 of 11 Revision: 1 Dates 1/92 TOTAL P.Eri ,i. '}}