Final Deficiency Rept Re Class 1E Limit Switches & Control & Solenoid Valves Not IEEE-classified in Documents.Initially Reported on 830509.Replacement of Equipment Will Be Completed by 860901 for Unit 1 & 891001 for Unit 2
ML20116D603
Person / Time
Site: Bellefonte  
Issue date: 04/16/1985
From: Hufham J
TENNESSEE VALLEY AUTHORITY
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8504290483
Download: ML20116D603 (2)


Text

___

y f

TENNESSEE VALLEY AUTHORITY D d"ieSSSut'dfr"eeY Yowe# N I r

April 16, 1985,S u a 17 q BLRD-50438/83-34 J

22 BLRD-50-439/83-30 U.S. Nuclear Regulatory Ccamission Region II Attn:

Dr. J. Nelson Grace, Regional Adninistrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Dear Dr. Grace:

BELLEFWTE NUCLEAR PLANI UNITS 1 AND 2 - FAILURE TO SPECIFY IEEE (LASS W PROCURE!ENT SPECIFICATIONS - BLRD-50-438/83-34, BLRD-50-439/83 FINAL REPORT The subject deficiency was initially reported to NRC-0IE Inspector Linda Watson on May 9,1983 in accordance with 10 WR 50.55(e) as NCR BLN EEB 8307.

Related NCR BLN BLP 8324 was then reported and is being handled jointly with NCR BLN EEB 8307. This was followed by our interim reports dated June 9 and November 4,1983 and August 13, 1984.

Enclosed is our final report.

If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours,

TENNESSEE VALLEY AUTHORITY J. W. Hufham, Mana Licensing and Regulations Enclosure cc:

Mr. James Taylor, Director (Enclosure)

Office of Inspection and. Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center (Enclosure)

Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 D

pA 9M s

8504290483 850416 8

I PDR ADDCK 05000438 S

PDR An Equal Opportunity Employer

ENaOSURE BELLEF3TE NUCLEAR PLANT UNITS 1 AND E FAILURE TO SPECIFY IEEE aASS W PROCUREENT SPECIFICATIONS BLRD-50-438/83-34, BLRD-50-439/83-30 10 TR 50.55(e)

NCRs BLN EEB 8307 AND BLN BLP 8324 FINAL REPORT Description of Deficiency Limit switches, control valves, and solenoid valves for safety-related systems which are required to be class 1E components were procured in the 1976-1977 time period without specifying the IEEE classification in the procurement documents. Because of this error caused by a failure by TVA personnel to recognize that the equipent required class 1E qualification, the necessary documentation to verify the classification of these components was not provided.

Safety Inplications Failure to properly specify IEEE requirements during equipnent procurement resulted in the purchase and subsequent installation of improperly qualified components in safety-related systems. Under accident conditions these components could fail and adversely affect the safe operation of the plant.

Corrective Action TVA has completed its review of this equipnent, has identified all the components which must be replaced, and has issued engineering change notice (EG) 2674 to implement this requirement. To prevent a recurrence of this problem, TVA has issued instructions to all Belldonte Nuclear Plant (BLN) electrical and mechanical employees that any electrical equignent with an A, B, D, E, F, G, or S division designation in its TVA UNID nunber is class 1E and must be specified as such for procurement purposes.

All replacement activities will be completed September 1, 1986, for unit 1 and October 1, 1989, for unit 2.

.