ML20116C907

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation for Rod Cluster Control Guide Thimble Plug Removal. Completion of Review Prior to Aug 1985 Will Allow Time to Purchase New Thimble Plugs If Removal Unacceptable
ML20116C907
Person / Time
Site: Prairie Island  
Issue date: 04/22/1985
From: Musolf D
NORTHERN STATES POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20116C911 List:
References
TAC-57544, TAC-57545, NUDOCS 8504290209
Download: ML20116C907 (1)


Text

-

$- - - m Q

Northem States Power Company 414 Ncollet Mall M:nneapohs, Menesota 55401 Telephone (612) 330-5500 I

April 22,1985 Director Office of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Safety Evaluation for RCC Guide Thimble Plue Removal We have completed our safety evaluation for the removal of rod cluster control (RCC) guide thimble plugs and concluded that the change can be done under 10 CFR 50.59. Since the NRC Staff has expressed interest in reviewing this safety evaluation, this report is being submitted for your review. In accordance with 10 CFR Part 170, a $150 check is enclosed as the required application fee.

Completion of your review prior to August of 1985 will allow us time to purchase new thimble plugs if their removal will not be acceptable.

l O kw, David Musolf Manager - Nuclear Supp rt Services DMM/TMP/tp o

c: Regional Administrator-III, NRC NRR Project Manager, NRC Resident Inspector, NRC G Charnoff

Attachment:

Report NSPNAD-8412 jl

\\

8504290209 850422

_A W

PDR ADOCK 05000282 1

P PDR l

QU Y