Category:TECHNICAL SPECIFICATIONS
MONTHYEARML20092C8231992-02-0606 February 1992 Proposed Tech Specs 5.1 Re Removal of Control Rods from Reactor & 4.2.b Re Visual Insp for Water Leakage from Shield Tank ML20137J0001986-01-14014 January 1986 Proposed Tech Specs Supporting possession-only Status to Assure Protective Storage of Reactor & Fuel Until Decommissioning Plans Finalized.Encl Safeguards Tech Specs Withheld (Ref 10CFR2.790) ML20133N2841985-10-22022 October 1985 Proposed Tech Spec Changes,Authorizing Possession Only Status ML20115J0561985-04-19019 April 1985 Proposed Rev to Tech Specs,Allowing Reactor to Stay in Continued Shutdown Mode w/fuel-bearing Control Rods Removed & Stored in Separate Locked Facility Pending Reactor Use for Research Project 1992-02-06
[Table view] Category:TECHNICAL SPECIFICATIONS & TEST REPORTS
MONTHYEARML20092C8231992-02-0606 February 1992 Proposed Tech Specs 5.1 Re Removal of Control Rods from Reactor & 4.2.b Re Visual Insp for Water Leakage from Shield Tank ML20092C8151992-01-31031 January 1992 Radiation Safety Manual,Catholic Univ of America ML20092C8191989-01-11011 January 1989 Catholic Univ of America Chemical Matls Safety Manual ML20137J0001986-01-14014 January 1986 Proposed Tech Specs Supporting possession-only Status to Assure Protective Storage of Reactor & Fuel Until Decommissioning Plans Finalized.Encl Safeguards Tech Specs Withheld (Ref 10CFR2.790) ML20133N2841985-10-22022 October 1985 Proposed Tech Spec Changes,Authorizing Possession Only Status ML20115J0561985-04-19019 April 1985 Proposed Rev to Tech Specs,Allowing Reactor to Stay in Continued Shutdown Mode w/fuel-bearing Control Rods Removed & Stored in Separate Locked Facility Pending Reactor Use for Research Project ML19209B9901979-08-0909 August 1979 Reactor Restart Rept. 1992-02-06
[Table view] |
Text
e-0 Technical Specifications Revisisn
- 1. Article 16.1.17 (Definitions), add:
" Article 16.1.17 Continued Shut Down Mode -
When the reactor is to be non-operational for a period of time greater than one year, the reactor shall be deemed to be in a _ continued shut down mode. Under this condition the reactor fuel-bearing control rods shall be removed from the reactor and stored in a locked facility separate from the reactor."
- 2. Article 16.4.1 (Reactivity Limits), add:
" Exception:
When the reactor is.in a continued shut down mode, the specifications (16.4.1 a through c) in this article shall not apply. However, upon application to the NRC for reactor startup, the specifications shall become fully applicable."
- 3. Article 16.4.2 (Control and Safety System), add:
" Exception:
When the reactor is in a continued shut down mode, the specifications (16.4.2 a through 1) in this article shall not apply. However, upon application to the n2C for reactor startup, the specifications shall become fully applicable."
- 4. Article 16.9.9.1 (Routine Reports), add:
"C. The annual operating report shall not be submitted during periods of continued reactor shutdown."
8504230356 850419 PDR ADOCK 05000077 P PDR