4.0 DESIGN FEATURES 4.3 Nuclear Steam Sucolv System (Continued)
- 4. 3.1 Reactor Coolant System (Continued)
The reactor coolant system is designed and constructed in accordance with the ASME Boiler and Pressure Vessel Code,Section III, Rules for Construction of Nuclear Vessels including all addenda through the winter of 1967 and the Code for Pressure Piping USAS B31.1.
The reactor coolant system is designed for a pressure of 2500 psia and a temperature of 650'F except for the pressurizer which has a design temperature of 700"F.
The volume of the reactor coolant system is approximately 6,616 cubic feet.
4.3.2 Reactor Core an Control q
ctc.
cre
- h. 1 approximate a right circular cylinder with an Q equivalent di; meter of 105.5 inche; and n active height Of 128 inchc;.
The reacter cerc 05:11 nc=:lly consist of Zircalcy 4 clad fuel red; containing slightly enriched uranium in the f0= Of ;intered 00 3
pellets.
The fuel rod: 0h:11 nc = ally be grouped into 133 :::cmblic;.
/
The c0rc cxces; reactivity shall be controlled by a ccmbination Of bori-
/
acid chemical :him, centrol element ::cmblic;, and mechanically fixed
/
bcron red; where required.
Forty ninc control cicment ;;;cmblic: cre i
distributed throughout the cerc :: chown in Figure 3.1 1 Of the USARt
/
fcur Of the CEA': arc full length non trippable CEA';.
/
Thelrea cto Eshal Mont alm 133;fde Mas sembl i esW Eachia's s embl yss hal 1
/
Eonsis t?ofhitH nfhi fcal o 7oMZ IRLOMfdslEF6d sni thianii ni ti al l
com dsitionofinitspal56rislig tlyTensichedG0FisiuinidiosideE fus inihtsrialGl.imitedlibbstitsti6nsfof9fiFc'6niuns?All.offess(U ta less
/
5 tsehfi l l egrdd s ff6rf f delgod s Mi nfs dchidan de(si th Ispprdysd ""*"~~
/
a 3plicatibn~sfofsfdelnodiconfiguratiohs%mapsbs7dsed!MseWassemblies %
s lallibeMimiteditosthoselfdeRdesig6AthatthaVsibeenlinh1 led!with"""
hpplisable1NRCMtafffaiprbyedR6deisand6:meth6dEshdishoint yftests?or k
analiseMt6ld6inplifkitifalRfsbisssfetRdsiignibasesi EAllimitedfhumlier '
~
6fsleadstestfassemblienthatihaWnottc6mpletedtrs pssestsfivehtssting"
/
ms/.pbelp., laced _linfdsnlimitingscoreEEegions,f" '
""'^p"
" ^ ^ ~
~"^
-. =
~
- - v.
I TheWea ct0&co rdTsh al Ucont ainM9 scont rolYel emen tih s sembl i esE (C EAs)%
)
Theicontrolfmatefialtshallibeisi1Yersiddiumicadnjiump'"bdroh4ArbideR*or /
/
hafnium?nietaltastapbfove_diby# ~dheiN.RCE ^ " ~~~""^"
- ' ' ~ '
" ^"y e
_ w o. s c -
s 4.3.3 EmeroencvheTdoMfia Emergency core cooling is provided by the Safety Injection System which consists of various subsystems, each with internal redundancy.
Included in the Safety Injection System are four safety injection tanks, three high-pressure and two low-pressure safety injection pumps, a safety injection and refueling water storage tank, and interconnecting piping as shown in USAR Section 6.
i
]
4-3 Amendment No. 6,20,60,109 9607190216 960715 PDR ADOCK 05000285 f ?,/
7 P
i i
- 5.0
/d)MINISTRATIVE CONTROLS 5.9.5 Core Operatine Limits Report Core Operating Limits shall be established and documented in the Core Operating a.
Limits Report (COLR) before each reload cycle or any remaining part of a reload cycle.
i b.
The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC as follows:
l~
OPPD-NA-8301-P-A, " Reload Core Analysis Methodology Overview" 1.
(Latest NRC approved revision as stated in the COLR).
)
2.
OPPD-NA-8302-P-A, "Neutronics Design Methods and Verification" l
(Latest NRC approved revision as stated in the COLR).
3.
OPPD-NA-8303-P-A, " Transient and Accident Methods and Verification" (Latest NRC approved revision as stated in the OLR).
g.
m 4'~if ' WCAP!12610MVANTAGETFGill!Assisubtf[RQ3filnefi99 hb The core operating limits shall be determined so that all applicable limits of the safety i
j c.
l analysis are met. The Core Operating Limits Report, including any mid-cycle i
revisions or supplements thereto, shall be provided upon issuance, for each reload cycle, to the NRC Document Control Desk with copies to the Region IV Administrator and Senior Resident Inspector.
l l
i 1
I i
k i
l l
ffQ l
4 5-17a Amendment No. 141,144,157 /
i i
Al's '
O
1 J
4 1
O.S. Nuclear Regulatory Commission LIC-96-0099 1
i j
i ATTACHMENT B 4
I 1
g i
1 I
l l
1 9
i 1
.3 l
l DISCUSSION, JUSTIFICATION AND NO SIGNIFICANT HAZARDS CONSIDERATIONS DISCUSSION AND JUSTIFICATION:
Omaha Public Power District (0 PPD), the licensee for Fort Calhoun Station (FCS),
Unit No.1, proposes to amend the Technical Specifications (TS) contained in Appendix A of License No. DPR-40 as follows:
TS 4.3.2. Reactor Core and Control TS 4.3.2 is proposed for revision to modify the description of fuel and control element assemblies.
Following the proposed revision, TS 4.3.2 will be identical to improved STS 4.2 " Reactor Core" of NUREG-1432. The revision will clarify that the reactor may contain fuel assemblies consisting of a matrix of zircaloy or ZIRLO' clad fuel rods.
The change will also permit the limited substitution of zirconium alloy, stainless steel filler rods, or lead test assemblies for fuel rods in accordance with NRC-approved applications of fuel rod configurations that have been analyzed with NRC-approved methods. This will allow the timely removal of leaking fuel rods or those that are a probable source of future leakage.
This change also 1
makes provisions for the loading of lead test assemblies into the reactor without requiring a specific TS change.
TS 5.9.5. Core Operatina Limits Report The proposed revision of TS 4.3.2 is supported by Westinghouse Topical Re) ort, WCAP-12610, " VANTAGE + Fuel Assembly Report," dated June 1990 (Westingiouse Proprietary). This topical report describes the fuel rod design bases, criteria and models, which are affected by the use of ZIRLO' cladding.
Consequently, WCAP-12610 is proposed for addition to the list of analytical methods located in TS 5.9.5b that are used to determine the core operating limits.
i i
4 e
1 l.
l 1
BASIS FOR NO SIGNIFICANT HAZARDS CONSIDERATIONS:
The proposed Technical Specification (TS) changes do not involve significant hazards considerations because operation of Fort Calhoun Station (FCS) Unit No.
1 in accordance with these changes would not:
J (1)
Involve a significant increase in the probability or consequences of an l
accident previously evaluated.
l The proposed revision to TS 4.3.2 is based on improved STS 4.2 of NUREG-l 1432. ZIRLO' is similar in chemical composition, physical and mechanical l
properties to Zircaloy-4, but features improved corrosion performance and l
dittensional stability.
These characteristics ensure that fuel rod j
cladding integrity and fuel assembly structural integrity are maintained.
l Fuel assemblies manufactured with ZIRLO' clad fuel rods meet the same design bases requirements as fuel assemblies manufactured with Zircaloy-4 l
cladding and the regulatory requirements of 10 CFR 50.46 are applicable to either material.
1 No concerns have been identified pertaining to reactor operation with a core comprised of fuel assemblies manufactured with Zircaloy-4 clad rods and fuel assemblies manufactured with ZIRL0* clad rods.
ZIRL0* clad fuel I
rods do not require a change to the FCS reload design and safety analysis limits.
Radiological consequences of previously evaluated accidents are not increased because the safety analysis dose predictions are not l
sensitive to the type of cladding material used.
The proposed limited l
substitution of zirconium alloy or stainless steel filler rods in i
accordance with NRC-approved fuel rod configurations will allow leaking l
fuel rods (or potential leakers) to be removed.
Therefore, the t
radiological consequences of accidents previously evaluated in the FCS Updated Safety Analysis Report (USAR) are not increased by this change.
The revisions to TS 4.3.2 listed above will not result in a change to any l
of the process variables that might initiate an accident or affect the radiological release for an accident.
The operating limits will not be changed and the analysis methods to demonstrate operation within the limits will remain in accordance with NRC-approved methodology.
There are no physical changes to the plant associated with the change to TS 4.3.2 l
other than the changes to the fuel assemblies.
Therefore, this revision does not involve a significant increase in the probability or consequences of an accident previously evaluated because the safety analysis to be performed for each cycle will continue to demonstrate compliance with all fuel safety design bases.
j 1
l l
i 2
hASIS FOR NO SIGNIFICANT HAZARDS CONSIDERATIONS (CONTINUED):
The proposed revision of TS 4.3.2 is supported by Westinghouse Topical Report, WCAP-12610, " VANTAGE + Fuel Assembly Report," dated June 1990 (Westinghouse Proprietary).
This topical report describes the fuel rod design bases, criteria and models, which are affected by the use of ZIRLO' cladding.
Consequently, WCAP-12610 is proposed for addition to the list of analytical methods located in TS 5.9.5b that are used to determine the core operating limits.
Based on the above discussion, these changes do not involve a significant increase in the probability or consequences of an accident previously evaluated.
(2)
Create the possibility of a new or different kind of accident from any accident previously evaluated.
Fuel assemblies manufactured with ZIdLO' clad fuel rods must meet original design criteria and thus they will not be an initiator for any new or different kind of accident.
All design and performance criteria will continue to be met by fuel assemblies manufactured with ZIRLO' clad fuel rods and no new single failure mechanisms have been found.
The use of fuel assemblies manufactured with ZIRL0* cladding does not involve any alterations to plant equipment or procedures that would i
introduce any new or unique operational modes or accident precursors. The j
substitution of zirconium alloy, stainless steel filler rods, or lead test assemblies for fuel rods will be limited to NRC-approved fuel rod 4
configurations. Therefore, the possibility of a new or different kind of accident from any accident previously evaluated is not created by this change.
(3)
Involve a significant reduction in a margin of safety.
The use of fuel assemblies manufactured with ZIRL0* clad rods does not change the proposed FCS reload design and safety analysis limits.
The normal operating conditions allowed for in the Technical Specifications will be taken into consideration for the use of these fuel assemblies, i
for each cycle reload core, the fuel assemblies will be evaluated using NRC-approved reload design methods to include consideration of the core physics analysis peaking factors and core average linear heat rate l
effects.
NRC-approved methods will also be used to analyze each configuration of zirconium alloy or stainless steel filler rods in fuel assemblies to l
demonstrate continued safe operation within the limits that assure j
acceptable plant response to accidents and transients.
Therefore, this change does not involve a significant reduction in a margin of safety.
3
4 a
l
~
8'A' SIS FOR NO SIGNIFICANT HAZARDS CONSIDERATIONS (CONTINUED):
1 Based on the above considerations, it is OPPD's position that this pro)osed amendment does not involve significant hazards considerations as defined
)y 10 1
CFR 50.92.
The proposed changes will not result in a condition that significantly alters the impact of the Station on the environment.
Thus, the proposed changes meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9), and pursuant to 10 CFR 51.22(b) no environment 61 assessment need be prepared.