Final Deficiency Rept NCR 3904 Re Willful Disregard of QC Procedures by Craft Supervisor.Initially Reported on 850207. Craft Supervisor Given Written Reprimand & Counseled Re QA Responsibilities
ML20113D001
Person / Time
Site: Bellefonte  
Issue date: 03/11/1985
From: Hufham J
TENNESSEE VALLEY AUTHORITY
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NCR-3904, NUDOCS 8504120199
Download: ML20113D001 (2)


Text

__

- g L* '

TENNESSEE VALLEY AUTHORITY CHATTANOOGA, TENNESSEE 37401 400 Chestnut Street Tower II y M$ \\4 P 2 M 11,1985 BLRD-50-4 M )\\ [

BLRD-50-439265.-09 U.S. Nuclear Eagulatory Commission Region IIl Attn: Dr; J. Nelson Grace, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia - 30323

Dear Dr. Grace:

A BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - WILLFUL _ DISREGARD OF QUALITY CONTROL PROCEDURES BY CRAFT SUPERVISOR - BLRD-50-438/85-09 AND BLRD-50-439/85 FINAL

-REPORT' The subject deficiency was initially reported to NRC-OIE Inspector Al Ignatonis on February 7,1985 in accordance with 10 CFR 50.55(e) as NCR 3904. Enclosed is our final report.

If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, l

TENNESSEE VALLEY AUTHORITY l

am, M ger icensing d Regulations Enclosure oc:

Mr. James Taylor, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center (Enclosure)

Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 438 PDR h l An Equal Opportunity Employer

[ 8f

ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 WILLFUL DISRE0ARD OF QUALITY CONTROL PROCEDURES BY CRAFT SUPERVISOR BLRD-50-438/85-09 AND BLRD-50-439/85-09 NCR 3904 10 CFR 50.55(e)-

FINAL REPORT Description of Deficiency During installation of B&B Insulation Raarlex Sealant Material in six

.mechnical sleeves in the control building, two sleeves 5mre pumped with the Radflex material after the quality control inspector informed the crew that the 30-minute placing time had expired. Bellefonte Nuclear Plant (BLN) quality control procedure (QCP) 5.18 references B&B-QCP-1030.212 that specifies that both of the components of the Radflex Sealant material must be in place within 30 minutes of the start of the blending.

The root cause of this deficiency was due to an independent decision by the responsible craft supervisor to place the material in violation of the controlled procedure. The supervisor's decision resulted from frustration involving previous attempts. to' obtain relaxation of the blending time limit.

Safety Implications Willful disregard of QCPs by a supervisor whose responsibilities include ensuring QCP compliance by his subordinates is a significant quality assurance breakdown which could adversely affect the safe operations of the plant.

Corrective Action Correspondence with the vendor representative who handles the subject sealant material revealed that the 30-minute time limit requirement as referenced in BLN-QCP-5.18 and vendor procedure B&B-QCP-1030.114 is primarily a safety factor used by vendor personnel when a catalyst is used by them in their installations. BLN Office of Construction (OC) personnel do not use a catalyst in their installations. When a catalyst is not used the blending time to installation may be extended to 90 minutes according to the

- manufacturer's instructions. Therefore, the sealant material is acceptable as is.

l The craft supervisor has been given a written reprimand for his actions which reminded him of his quality assurance responsibilities and notified him that future instances would result in more severe disciplinary action.