Text
~
NT.C Eg;en, l
% doca'dredst K3 Public FORT ST. VRAIN NUOLEAR GENERATING STATION go,7f,?
OSerVICO*PUBLIC SERVICE COMPANY OF COLORADO 3/11/85 (J
w RADIOLOGICAL EMERGENCY RESPONSE PLAN - STATION ISSUE EFFECTIVE NO.
SUBJECT NUMBER DATE l RERP-TSC Technical Support Center Procedure 15 -
03-11-85 RERP CR-UE DELETED 04-25-84 RERP-VC Visitors Center Procedure 3
01-03-84 l RERP-PHONE LISTS 26 03-11-85 O
/
S. -}
O
,,are 1x
=
PUBLIC SERVICE COMPANY OF COLORADO RERP-TSC Issue 15 FORT ST. VRAIN NUCLEAR GENERATING STATION Page 1 of 13 k""W%.w w%
f {&.jWy' ' ?:.
P T']
TITLE:
TECHNICAL SUPPORT CENTER PROCEDURE O
(Epyg L% &
O'1 v Wagg;
( l % g _,-
- & % & w.y ISSUANCE l..
AUTHORIZED j
AM; EFFECTIVE PORC RORC 611 MAR 4.1985 DATE 3 8 5 REVIEW TABLE OF CONTENTS Section Description Page 1.0 Criteria for Implementation...................................
3 2.0 Procedure..................................................... 3 3.0 Responsibilities............................................. 9 (v^;
4.0 References.................................................. 11 5.0 Referenced or Suoporting Procedures..........................
11 Figure 1 Site Sector Map.........................................
1 Figure 2 EAB Map.................................................
1
[
Figure 3 Response Center Manning Requirements................... 1 Support Equipment / Material...........................
1 Sign In/Out Sheet................................... 1 Datasheet 1 Preliminary Assessment Fact Sheet................... 1 Datasheet 2 Assessment of Plant / Core Status..................... 1 Datasheet 3 Plant Status Board Update........................... 1 Checklist 1 TSC Checklist....................................... 1 Work /Datasheet/Checkli st Control Li st............................. 1 m
I i
')
l PORM 372 22 3642
RERP-TSC Issue 15 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 2 of 13 0SerVICO PUBUC SERVICE COMPANY OF COLORADO V
Forms Use Reporting Sheet *......................................... 2 ANYTIME A WORKSHEET, DATASHEET, OR CHECKLIST HAS BEEN WRITTEN ON, COMPLETE THE REPORTING SHEET ATTACHED IN THE TABBED WORKSHEET SECTION AND FORWARD IT TO THE NUCLEAR DOCUMENTS SPECIALIST, FORT ST. VRAIN. DO NOT WRITE ON ANY WORKSHEETS, DATASHEETS, CHECKLISTS, OR REPORTING SHEETS IN THE PROCEDURE ITSELF. ALL WORKSHEETS/DATASHEETS/ CHECKLISTS ARE TO BE TAKEN FROM THE TABBED SECTION FOLLOWING EACH PROCEDURE.
4
'J V
FORMiBl372 22 3M3
RERP-TSC Issue 15 FORT ST. VRAIN NUCLEAR GENERATING STATION Page 3 of 13 0 Public Service pusuC SERVICE COMPANY OF COLORADO s
Q., Y 1.0 Criteria for Imolementation When the FSV Radiological Emergency Response Plan (RERP) requires augmentation of resources, generally for an ALERT or higher emergency classification, the Technical Support Center (TSC) Director shall activate the TSC.
2.0 Procedure The TSC serves as the center for site emergency command activities and provides a central location for technical appraisal of plant conditions.
The TSC operates under the direction of the Technical Support Center Director, and also serves as the focal point for onsite-offsite communications.
2.1 Center Activation During non-working hours, those PSC personnel required to man the TSC are notified by telephone (see RERP-HOME).
It is the responsiblity of the TSC Alternate Director, or the first individual contacted by the center director, to insure those notifications are made. Refer to the RERP PHONE LIST for instructions and personnel names and numbers.
(3 V
The first person to arrive at the TSC is responsible to verify habitability of the center.
The first technical or management individual to arrive at the TSC is responsible to verify that habitability has been checked, set up phones, and establish communication with other emergency centers. Checklist 1 is provided as guidance for both initial steps and required action throughout the activation of the TSC.
2.2 Communications Establish communication with the Control Room and verify primary and secondary communication links are available.
Await communications to be established by the Personnel Control Center (PCC) and by the Forward Command Post (FCP).
U) l FoRMitl372 22 3043
RERP-TSC Issue 15 0 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 4 of 13 SerVlCe PUBUC SERVICE COMPANY OF COLORADO 7c) 2.3 Accountability Initial site accountability is established per Administrative Procedure G-5, Personnel Emergency Response.
Personnel arriving at the TSC shall sign in to establish initial center accountability.
If personnel are required to leave the site after initial site accountability is complete, they should report to the Personnel Control Center for continued site accountability. Personnel leaving the TSC shall sign out and in upon return to maintain center accountability.
2.4 Personnel Responses 2.4.1 TSC Director The TSC Director assumes overall responsibility for the coordination and direction of onsite emergency response centers.
The TSC Director announces center activation and informs his staff of his assumption of duties as Directoc.
He briefs his staff to inform them of general plant conditions and informs personnel of 7s f
)
any particular assignments of responsibility.
Based upon the assessments by the TSC Staff, the TSC Director is provided the " Assessment Fact Sheet" (Datasheet 1).
The TSC Director communicates with the Corporate Emergency Director (CED) via an open line to the Forward Command Post (FCP).
As Emergency Coordinator, the TSC Director is in command of onsite emergency operations and provides direction and coordination to the Control Room Director via the individual in contact with the Control Room.
As soon as the Personnel Control Center has been activated and communications established, the TSC Director will, via the person in contact with the PCC:
a)
Direct the PCC Director to organize repair and damage control teams, radiological survey
- teams, or search and rescue teams (as required).
OV N mem2 22.see
RERP-TSC Issue 15 A Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 5 of 13
%)7 Service PUBUC SERVICE COMPANY OF COLORADO l
b)
Direct the PCC Director to assemble additional
[
Operations personnel to assist in operating plant equipment (as required).
c)
If plant conditions warrant, direct PCC Director to evacuate non-essential personnel from the plant.
2.4.2 Plant Condition Assessment (Off-Duty Shift Supervisor)
The off-duty Shift Supervisor will be prepared to I
make a preliminary assessment of the plant status, focusing on significant plant problems and trends.
i If requested, he will also make a preliminary assessment of the sequence of events that led to j
the emergency, and report his findings to the TSC e
Director.
igi 2.4.3 Engineering and Technical Analysis (Technical Services Engineering Supervisor / Senior Plant Engineer)
The Techaicai Serv 4ces Easineerins i
O Supervisor / Senior Plant Engineer performs a
5; preliminary assessment of the plant / core status by i
i completing " Assessment of Plant / Core Status" 3
(Datasheet 2), and provides additional information i
as needed to update the status board (Datasheet 3).
j 4<
He remains in contact with Technical Liaison personnel at the Forward Command
- Post, and transmits information to the FCP with the O
assistance of Technical Support individuals.
[
He shall assign personnel to update the status
- l boards as required.
[
W.
He verifies the data logger information and
.r.
receives a briefing on the assessment form that the Technical Advisor in the Control Room has 1
completed.
With the concurrence of the CR Director, he obtains the " Alarm Typer" printout, if required.
An alternative to the Alarm Typer printout is to utilize the " EVENTS LOG" on the 2 on I console.
O j
2 a
FORM (Bi372 22 3643 r
'_b RERP-TSC Issue 15
-m FORT ST. VRAIN NUCLEAR GENERATING STATION Page 6 of 13 4
O Public service PUBUC SERVICE COMPANY OF COLORADO
.O 4
As soon as the Forward Command Post (FCp) is
[
activated and communications established, the
-A Engineering / Technical Analysis or Technical Support a
individual will:
a)
Inform FCP Technical Liaison personnel of the status of the emergency using the Status Board Update sheets (Datasheet 3). These datasheets summarize the data and calculations performed 3
at the TSC.
y b)
Maintain a continuous open line to the FCP to 2
provide prompt updating of the status of the j
amergency.
]
2.4.4 Technical Support (Technical Services
]
Engineers / Technicians)
E
=1 Technical Support individuals remain in contact M"
with the Control Room, Personnel Control Center, Forward Command Post, and NRC as required.
They assist the Engineering / Technical Analysis i
individual with event assessment as requested, and h
transmit data to the other emergency response centers as it becomes available.
j e
2.4.5 Emergency Maintenance (Superintendent of
']
Maintenance / Maintenance Supervisor - Electrical)
]
The Superintendent of Maintenance / Maintenance j
Supervisor - Electrical advises for the necessity of perfoeming repair work on damaged mechanical and 4.
electrical eouipment, estimates time and manpower requirements for emergency repairs, and develops emergency repair work procedures as required, j
2.4.6 Instrument and Control (Superintendent of Nuclear l
Betterment Engineering /Results Engineering i
Supervisor) 1 The Superintendent of Nuclear Betterment i
Engineering /Results Engineering Supervisor advises for the necessity for repair / installation /
i s
modification of instrument and control equipment.
i e
a e
i FORMitl372 22 3643
RERP-TSC Issue 15 0 SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 7 of 13 Pusuc sERVlCE COMPANY OF COLORADO
=6V 2.4.7 TSC Radiological Assessment (Senior Plant Engineer / Technical Services Engineer)
The Radiological Assessment Individual performs offsite dose projection calculations on an as needed basis (approximately every 30 minutes) and provides the results of these calculations to the TSC Director and the Radiulogical Assessment Coordinator (at the FCP).
Results are also prepared for use ir updating the Radiological Status boards at the TSC and the FCP (see RERP-DOSE).
He will also confer with the Radiological Assessment Coordinator with regard to protective action recommendations.
In
- addition, he will relay offsite dose projections, meteorological data, and release status to the senior Health Physics representative at the TSC for use in directing field monitoring teams.
() -
2.4.8 Senior Health Physics Representative (Health cs Physics Supervisor / Health Physicist) a)
Directs Health Physics / Radiochemistry to remove charcoal cartridges and analyze for the I-131 release, if necessary.
b)
Obtains airborne contamination and radiation surveys in the Control Room', and infotms the TSC Director of the results.
c)
Ensures personnel dosimetry is distributed and emergency worker exposure criteria is followed (see RERP-EXP).
d)
Ensures that one dosimeter is used in the TSC to keep track of the exposure of TSC personnel, e)
Evaluates doses of personnel from inhalation of radiciodines (projected or received) and confers with the Radiological Assessment Coordinator with regard to the need for i
administration of Thyroid Blocking Agent (see RERP-THYROID).
Directs any such administration authorization through the PCC Director and station Health Physics staff.
7s.C-L I
FORMi81372 22 3643 i
RERP-TSC Issue 15 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 8 of 13 0 $9tVICO PusuC SERVICE COMPANY OF COLORADO sp v
f)
Ensure that monitoring teams obtain in plant radiological surveys.
g)
Depending upon the duration of the event and the exposure rate, the senior Health Physics representative will make recommendations to the TSC Director for personnel relief or stay times (see RERP-EXP).
h)
Maintain continued contact with the Radiological Assessment Coordinator and Personnel Control Center Director regarding any needs for Thyroid Blocking (see RERP-THYROID).
1)
Continue to evaluate the incoming field monitoring data (see RERP-FIELD) and prepare data sheets allowing comparison of actual data with dose projections being made by the TSC Radiological Assessment individual.
An adequate supply of data sheets is provided in RERP-FIELD for this task.
(T-In
- addition, the senior Health Physics v'
representative will maintain ongoing communications with, and control over, the field monitoring teams dispatched from the PCC.
He will utilize dose projection data as a basis for determining stay times and thyroid blocking need.
2.4.9 Administration / Logistics (Nuclear Documents Supervisor / Nuclear Documents Specialist)
The Nuclear Documents Supervisor / Nuclear Documents Specialist provides technical documents, as required, assures that TSC personnel have obtained necessary documents and supplies for performance of their emergency assignments, and assists the TSC Director in transmission of information to other emergency response centers. This individual also assists in keeping logs of events and actior.s taken, as required.
(3 G!
FoRMtelM2 22 3843
o RERP-TSC Issue 15 0SerVlCG Public FORT ST VRAIN NUCLEAR GENERATING STATION Page 9 of 13 PUBUC SERVICE COMPANY OF COLORADO
/)
V 2.4.10 Computer Support (Senior Computer Analyst / Senior Programmer) a)
The Senior Computer Analyst / Senior Programmer will assist in software / hardware problems as directed by the TSC Director, and arrange for offsite advice / assistance as directed by the TSC Director in the area of software / hardware problems.
b)
The Senior Computer Analyst / Senior Programmer will also provide assistance on an as-needed, as available basis to the TSC Radiological Assessment individual in the tasks of data collection and/or data entry to the offsite dose calculation programs (RERP-DOSE).
2.4.11 Overall TSC Staff a)
Collect data for evaluation of the emergency.
b)
Assess trends and operating status for the purpose of providing advice to Operations o
personnel acting through the Control Room V
Director.
c)
Analyze the effects of equipment failures, temporary modifications and changes in operating status and procedures.
d)
Assess the accident potential, and the effect of such potential on the health and safety of the public.
e)
Request technical assistance (either in-house or contract) on an as-needed basis to cope with various situations that develop or may develop.
f)
Assist in providing periodic updates to the personnel in contact with emergency center.
Updates to the FCP are of the greatest importance, and should be of sufficient detail and frequency so that the FCP can effectively communicate and coordinate with the state / local / federal emergency response forces.
2.5 Recovery The decision to recommend de-escalation or initiation of
'l post-emergency recovery efforts rests with the TSC Director.
FoRMte 372 22 3643
RERP-TSC Issue 15 0 SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 10 of 13 PUBUC SERVICE COMPANY OF COLORADO
=nU The TSC Director will base his decision on the following guidelines:
Radiation levels are stable or decreasing with time.
Releases of radioactive materials to the environment have ceased or are controlled within permissible license limits.
Fi re, flooding, or similar emergency conditions no longer constitute a hazard to the plant or station personnel.
Measures have been successfully instituted to correct or compensate for malfunctioning equipment.
The recommendation of the CR Director.
When the.TSC Director deems it advisable, he will recommend de-escalation or termination of the emergency to the Corporate Emergency Director at the FCP.
The authority and responsibility to declare de-escalation to a lower emergency class or termination of the emergency p) response activities and conversion to a recovery phase is~
rests solely with the Corporate Emergency Director at the FCP (see RERP-FCP).
3.0 Responsibilities Site emergency command activities are centered in the Technical Support Center, located immediately adjacent to the Reactor Building and within short walking distance of the Control Room.
The.TSC also serves as the primary point for onsite-offsite communications.
3.1 TSC Director The TSC Director is in command of onsite emergency operations. The TSC Director is authorized to initiate emergency actions, including declaration of a particular emergency class and providing protective action recommendations to offsite authorities.
The TSC Director's responsibilities are:
Assumes overall responsibility for the coordination and direction of onsite emergency response centers; Transmits preliminary assessment information to the
=
(n)
FCP; w
Directs the Personnel Control Center (PCC) actions; romisim.22.aso
i RERP-TSC Issue 15 0SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 11 of 13 PUBUC SERVICE COMPANY OF COLORADO
=-
1
,uj.
Confers, on an on going basis, with the Corporate Emergency Director (CED) after activation of the FCP; and Notifies the CED of the need for additional support or assistance.
Recommends de-escalation or initiation of post emergency recovery efforts.
3.2 Engineering and Technical Analysis Engineering and Technical Analysis personnel are responsible for direction of core physics
- analysis, electrical and mechanical engineering activities, liscensing related activities, procedures development, and system analysis as required. They are responsible for the preparation of data sheets for use in updating the plant status board,. and for ensuring that information is transmitted to-other emergency response centers as required.
Technical Support personnel may be utilized to assist in these areas.
3.3 Technical Support
()
Technical Support personnel are responsible to assist Engineering and Technical Analysis individuals in the collection and transmission of data. They may be utilized to communicate with personnel at the Forward Command Post, Control Room, Personnel Control Center, and to the NRC.
3.4 Plant Condition Assessment Plant Condition Assessment personnel are responsible for the assessment of plant status, focusing on significant plant problems and trends, and for providing recommended corrective actions to the TSC Director.
3.5 Emergency Maintenance Emergency Maintenance personnel are responsible to recommend repair / damage control and corrective actions for plant mechanical and electrical systems. This individual estimates time and manpower requirements for emergency repairs, and develops emergency repair work procedures, as required.
O FORMi81372 22 3643
RERP-TSC Issue 15 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 12 of 13 0 SerVICO PUBLIC SERVICE COMPANY OF COLORADO
'a V
3.6 Instrumentation and Control Support The Instrumentation and Control (I&C) individual determines alternative I&C capabilities or configurations, and advises for the repair / installation / modification of I&C equipment.
3.7 TSC Radiological Assessment The TSC Radiological Assessment individual is responsible to assess offsite radiological doses and consequences, determine affected offsite areas, and confer with both the TSC Director and the Radiological Assessment Coordinator (FCP) regarding calculation results and recom ended offsite protective actions.
In
- addition, the TSC Radiological Assessment individual should confer with the Health Physics representative at the TSC regarding offsite dose projections in areas where field monitoring teams are to be deployed.
The TSC Radiological Assessment individual is responsible for verification of any calculation prior to transmission to the Radiological Assessment Coordinator at the FCP.
ps 3.8 Health Physics d
The senior Health Physics representative at the TSC is responsible for the assessment of onsite radiological doses, direction of all Health Physics / Radiochemistry survey personnel or teams, ensuring that adequate personnel dosimetry measures are taken, and evaluation of doses of field and emergency team personnel (particularly with regard to a need for thyroid blocking).
3.9 Administrative and Logistics Support The Administrative and Logistics Support individual provides technical documents, provides assistance with communications and analytical equipment, arranges required clerical support beyond the personnel directly assigned to the
- TSC, and makes any arrangements necessary for food / transportation / housing support as required.
3.10 Computer Support Computer support personnel provide technical support in the areas of computer hardware and software modifications / development /or repair, as required.
In addition, this individual is responsible to arrange for timely offsite advice or assistance as directed by the TSC Director.
FonM(8)372 22 3643
r RERP-TSC Issue 15 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 13 of 13 O SerVICO PUBUC SERVICE COMPANY OF COLORADO
=cU Computer support personnel also have received training in offsite Dose Calculation methodology.
This training is provided for the purpose of assisting the TSC Radiological Assessment individual in gathering data
- and, where requested, assist in data entry at the TSC plant computer console.
4.0 References 4.1 FSV Radiological Emergency Response Plan 5.0 Referenced or Supporting Procedures 5.1 RERP-CR, Control Room Precedure 5.2 RERP-FCP, Forward Command Post Procedure 5.3 RERP-PCC, Personnel Control Center Procedure 5.4 RERP-VC, Visitor's Center Procedure 5.5 RERP-HOME, Home Packet for Off-shift Notifications
(-
5.6 RERP-DOSE, Offsite Dose Calculations V) 5.7 RERP-PAG, Protective Action Guideline Recommendations 5.8 RERP-EXP, Emergency Exposure Guidelines 5.9 RERP-THYROID, Thyroid Blocking Agent Administration 5.10 RERP-FIELD, Field Monitoring Procedure 5.11 RERP-ORG, FSV Emergency Organization and Resposibilities 5.12 RERP PHONE LISTS 5.13 RERP-SUPORG, Use and Coordination of Non-PSC Support Organizations n
FoRMIB)372 22-3fA3
- -.-+
RERP-TSC Figure 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0SerVICO 9
PUBUC SERVICE COMPANY OF COLORADO
.O FIGURE 1 GEOGRAPHICAL AREA IDENTIFICATION DESIGNATIONS n
,-e._
,,o :..- u.n m m -.=
R
' ".c
. u g dl
! M l
'l "h """ I@
p p.
u...,
I l
tN l,l l
/
I cau-age y.. w..n. g %.
,, 6
'l l
I,t I
g E
&c
,c m
S g
\\ \\,i, j-O if N /iy ii nqJ e
v g
o s
sa_
w s,u, nu s-e i
4W-N f "X
\\A
~
?(
44 J\\
g 3-g i, v i: x
.gxl rkg 71 -lI i'l N Ni_
i ti M.. +'p!
l (.
dy fil il il l l
.g e
S l
u'u ' /j:i\\ Td{
l' 1 og
'l/
,i y j ~~'
g 8
i tl D \\fl
\\r(14971 We~; bJl,
~~
g W ir W 4lptpi Kyl
/Pjv i<
g C5,gy rd uNy ni/ i y
t g
g "i w d
/pg+
=
JA_ g usII; U +4!/l e \\y s
l N a I,
g wA N cio 'ML: mIV 'I mf
$I fl 1 Mfi l l!
t i jv5 i
l-
- ~
!t ;+ M ;;
nt\\w
\\
\\
\\
4 i" (~gh I
I
,i
-,{il i.ie,.
g g
ig/ l I
t_- -91?'l l
- j7 "
l l
' O FORM tBl372 *2 3643
f RERP-TSC Figure 2 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0SerVICO 9
PUBUC SERVICE COMPANY OF COLORADO
.<)
(s.s FIGURE 2 EXCLUSION AREA MAP U'
ll 4
0 RlY
,e QyFARNHOUSE (R. Russell)
/dY
\\ - A.1 y
\\.- s.l j
{
45'
" fb M!
f WEtt 4
/.,
' PUNTMICN e, COOUNG l
a[ ] ;
n e
l s m a-i TRAINING.
O e\\ j /R ENTER j
C gg EACTER abloeNG 270*
C E 90' w_m.g?
h 1
,4,c, l
j
-QA C WELL 3 l
ll=;
~
e, e7%.%
1_
i l
b, p"*
7
%. M'e l
wn 12 s
C s'N
+
p.s'%,.
i
.\\
- )
r; N-
'*h -
~
(
'n o
(n) g
'8
- I
- r P
1 FORM IB1372-22-3643
RERP-TSC Figure 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0SerVlCe PUBLIC SERVICE COMPANY OF COLORADO s,
s (v)
I.
g_____
h3
(
=
. N5 5
't E
l C
- f e
g [g 5
i W.*
=
a at s
--g e3 E
i g
s
(
N I:: 's 5
2! '
s
.5
$- b s
y g
=
r-5..
g 5
i Si s o 85 W:
'1
, -5 5 sg E t E
E 15 5 I f_f.
s
- g g85 3 08 5
3_:g.
r_5__ 5 7__ f _5 P__3_
<a 8
st 5,,
g_,
t!*
9 r
=d.
y s :s
.,== e s
1 g
x 2:re s
,W 23 g
=>-" 5
- g y
j5 5.
5 8
- s>E t s
dti 3
- 3 d-2 E
.g
_5 2
15 s
EI.sl l"s g
@ 15
- 3::
E_
5:
"g
- 5 gg sa s
- -- j
.5:
gg 5 _a g
_g_g cs 2
! !E d_f5___ _r_ _
U s,i, 28
____ I 1.
E____
__l "i i
____[____
t 31 g.
e
.82 3
6$
f.
Et U3 lE2
'5 o
s s eg i:: we
.e s
- g8 2
en v.s
.<=
m
-(* *e
< er F. :e
!e g.:
I-s
- .=
ja s
g =N 1 50 e
E
_gj
_g 2.:
___3 N s
s 5 N
-=z 8
- N e
g {=I g'-
E N I
s s
i
' g-M' g
e
- Ct o
-[
b,Cl a
s t h:
r
=
e a
e y e _:
8d 3
5 2=
9 t
s 5e l s r.
E s
e e
8 8
r g
__F_ _ _ ber_ _ __P_ _r F_i
__P_g g
i__
=__ _
__r_ _ _e y
g ___
- =
k
,L E*
l fg
- s b,t dE is l5 g
- 25
- I "A
3 E
i g'
tE5 I
T
.e
-.2 s
t S
7 8
5 **
- ':' k {.
EE
=a u :Ea
-g ".'
0 g
- " L' lg I' 4
Eg M
c,o={ $ c< 9 (.5_5".
r
.2
- s 1
e
- -l e e g ::
g:
5 l
is
- ge e-te i.
g s=t_ __
p< F_5g s
8 <P_5 e =:
_1_:,e__
9-L_F__ e yL _:_ _
es
=
.,_ P_ <
___ ~___
_r_ _
>As FOl'tM(Bl372.ll2 3643
RERP-TSC Attach. 1 O SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
PUBUC SERVICE COMPANY OF COLORADO
=,,- 3 V
SUPPORT EQUIPMENT / MATERIAL 1.
Communications equipment 2.
P & I's (one-half size set) 3.
FSAR, Reference Design Manuals, EP's, SOPS, OPOPs, RERP J
4.
Office supplies a)-
pen / pencils b) chalk c) graph paper d) calculator 5.
Sector / regional maps 6.
Health Physics survey maps (of FSV buildings-see HPP-1 as required) 7.
Site maps 8.
Dosimetry for TSC staff 9.
' Personnel Accountability Records l
- 10. Scott-Air Paks 11.
RM-14/15 i.
i l
lD l
FORM (B)372 22 3643
I RERP-TSC Public FORT ST. VRAIN NUCLEAR GENERATING STATION 55 u
- Service" PUBLIC SERVICE COMPANY OF COLORADO Page 1 of 1
%.)
i SIGN IN/00T SHEET I
BE SURE TO FRISK UPON ENTERING TSC!
I ll I
l i
IDOSIMETERIDOSIMETERI Il I
l i
i NUMBER I READING l l l NAME I TIME IN I TIME OUT I DESTINATION I OR N/A I OR N/A I II I
I I
I I
I II I
I I
I I
i 1I I
I I
I I
I II I
I I
I I
I II I
I I
I 1
1 1I I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I e's II I
I I
I I
I kJ lI I
I I
I I
I II I
I I
i i
l l I I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I i
1 II I
I I
I I
I lI I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I II I
I I
I I
I o
ll l
l l
l l
l FORMiCl372 22 3643
RERP-TSC Datasheet 1 0SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
PUBUC SERVICE COMPANY OF COLORADO
,m k..-
PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NDTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event (O
4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees for miles.
Sectors Affected:
Release Rates (Ci/Sec): Noble Gas Radiciodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate
,OV FoRMIBl372 22 3643
RERP-TSC Datasheet 1 0SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 PUBUC SERVICE COMPANY OF COLORADO N]
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant-Engineer / Reactor Engineer).
6.
Emergency Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries 7-()
a)
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
O wi
- "i8'372 22.as42
RERP-TSC Datasheet 2 O service Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
PUBLIC SERVICE COMPANY OF COLORADO
.-x ASSESSMENT OF PLANT / CORE STATUS
- TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER
- NOTE:
Completion of all lines not required. The Datasheet is provided for guidance only, and should be utilized to the extent necessary.
Primary System Date/ Time 1.
Date/ Time of Event 2.
Current Reactor Power 3.
Primary Ccolant Pressure psia 4.
Primary Coolant Flow 5.
Operating Circulators A B C D.
Motive Power: Steam.
Water
/-(r,)
If water, which header? Emer. F.W.
Emer. Cond.
6.
Purification train in use A B: Storage, PCRV, or Ventilation 7.
Indication of fuel damage (Y/N)
RT-9301 reading (RR 93256, pt 10) cpm RT-9301 trend 8.
Is heat removal capability adequate (Y/N) 9.
Can cold-shutdown conditions be met (Y/N)
(Refer to SDP 12-02 or SR 5.1.4-W-P)
- 10. Obtain Technical Advisor assessment sheet data, as required (/)
Secondary System 1.
Loops Operating I II 2.
Feed pumps operating A B C 3.
Feed to S/G's Norm F.W.
Emer. F.W.
(v~')
Emer. Cond.
4.
Secondary flow I _
Kib/hr.
II kib/hr.
FORM (Bl372 22 3643
I=
)
RERP-TSC Datasheet 2 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 O SerVICO 9"
PUBUC SERVICE COMPANY OF COLORADO 5.
Status of aux. boilers.
nU
' FORM tB)372 22 3643
RERP-TSC Datasheet 2 O SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Cm.
PUBUC SERVICE COMPANY OF COLORADO V
ASSESSMENT OF PLANT / CORE STATUS TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER Remarks Time Description
%,/
j %,
%l FORM 18)372 22 3643
RERP-TSC Datasheet 3 0 service Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9'
PusuC SERVICE COMPANY OF COLORADO t, 3 i
%J f
-3 m3j:
+
a
=-
, 8 1 : : =-
m E
s7"i.
533 2 2 : t
$*2
...r...
aI_12
_s I
1 I
13 c
1 8
4 5
8 s
a=
m s3 l
=
2 l
V!
ss z a
e o
1
.s i!-
5* 11
)
-a r
2 if 3
e
,,)
i i
(v o
u o
=
r 5
I 3 :
3
- 2 5
1:
I l_. -
- c -
g
- !::.ges:
s: :
s-*:
41:
r:
r e
sal :a.
a_
e i I :a
- 1 5r m
a232 2
- : 3 2: : :
i a
.si sil3lig"ji!
' si:
I
- .e; I::I I;:
g:
- ess:
3
.2 3ea:g,:e i
t 11..:
m i_ s.s _
o 2
C 3
p v
FORMi81372 22-3043
r RERP-TSC Checklist 1 0 Service Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9'
PUBUC SERVICE COMPANY OF COLORADO Ll TSC CHECKLIST To be completed by Administration / Logistics support personnel.
TIME 1.
Habitability verified.
2.
Sign-in sheet (Attachment 2) set up by door.
3.
Dosimeter assigned to TSC gene *:'. area to monitor overall persunnel eyess re.
4.
Control Room television set up.
5.
Copy of completed notification form obtained from Control Room.
6.
Preliminary Assessment Fact Sheet (Datasheet 1) completed and submitted to TSC Director.
7.
Center accountability complete:
e~
f s
. (_,/
TSC Director Technical and Engineering Analysis Radiological Assessme,t Plant Condition Assessment Sr. H. P. Representative Emergency Maintenance I&C Administration / Logistics Computer Support Technical Support
~
8.
TSC activated; initial staff briefing conducted.
9.
Communications established Control Room Personnel Control Center Forward Command Post
- 10. Plant Status Board updated.
- 11. Radiological Status Board updated.
s_-
-.,m.m.
RERP-TSC Checklist 1 Public.
FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15
- 0. SerVICO 9
PUBUC SERVICE COMPANY OF COLORADO V
- 12. Personnel Accountability Status obtained Verify that Visitor's Center notified Initial (from Shift Supervisor -
may pass through the CR Director)
Continuing (from PCC Director)
- 13.. Injury Reports transmitted to FCP.
- 14. PCC evacuation recommended.
- 15. Requests for Additional Personnel Made Site Personnel Other PSC Contract
_16.
In-Plant Survey Teams Status
,,)
('-
Dispatched Report Received
- 17. Site Survey Teams Status Dispatched Report Received
- 18. Exposure criteria for emergency workers being followed (see RERP-EXP) f^x FORM t81372 22-3643
RERP-TSC WS/DS/CL 9SerVlCe Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
PUBUC SERVICE COMPANY OF COLORADO
..rs U
Work /Datasheet Checklist Control List Worksheet No.
Title Number Copies None N/A N/A Datasheet No.
1 Assessment Fact Sheet - TSC Director 10 2
Assessment of Plant / Core Status 5
3 Plant Status Board Update 10 (O
,)
Checklist No.
1 TSC Checklist 2
s l
- O l
FORM (B)372 22 3643
RERP-TSC WS/DS/CL Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0iService PUBUC SERVICE COMPANY OF COLORADO
\\-)
FORMS USE REPORTING SHEET Nuclear Documents Specialist:
This sheet is being transmitted to report use of forms from a controlled copy of the Radiological Emergency
Response
Plan Implementing Procedures, BOOK NO.
located at The following forms have been utilized from this copy:
Worksheet Numbers Copies Used
()T Datasheet Numbers Cooies Used Checklist Numbers Copies Used The procedure affected by this sheet is shown in the header to this page, unless' otherwise noted below in the comments to this reporting form.
When this form is received, it will be necessary to replace the noted number of forms, as well as this " Forms Use Reporting
()
Sheet" for the affected procedure in the affected book.
j s.
FoRMt81372 22 3643 i
RERP-TSC WS/DS/CL Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0 SerVICO 9
PUBUC SERVICE COMPANY OF COLORADO
-,b FORMS USE rep 0RTING SHEET (Continued) 3 COMMENTS Reported By:
Date:
Nuclear Documents Specialist Date Received Date Replaced Nuclear Documents Specialist will transmit this form to the h
originating individual / department upon completion of this form to notify users that the procedure has been updated and that all worksheets, checklists, and datasheets are present in the required number of copies.
FORM 18)372 22 3643
i RERP-TSC Datasheet 1 Public.
FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9'
s-) Service PUBLIC SERVICE COMPANY OF COLORADO
, L)
PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event
' (]
4.
Radiological Assessment (Attach ~
screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees for miles.
. Sectors Affected:
Release Rates (C1/Sec): Noble Gas Radiciodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate 3(o FoRMIB13M D 3M3
~
... _, _ -.. ~
RERP-TSC Datasheet I Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 f
) Service PUBLIC SERVICE COMPANY OF COLORADO
= g
~. J
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is":
(Reference RERP-PAG per Radiological Assessment recommendation) 5.
. Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
. Emergency Repairs required-(per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries g'
V a)
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
.d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
/^s FORP/ftl372 22 3643
RERP-TSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
SerVICO PUBLIC SERVICE COMPANY OF COLORADO u
PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event 4
f) u 4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to
-degrees for miles.
Sectors Affected:
Release Rates (Ci/Sec): Noble Gas Radioiodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate ___
Thyroid Dose Rate
!")
'J FOkMiel372 22 3643
RLkP-TSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
) SerVICO PUBLIC SERVICE COMPANY OF COLORADO
-/
).
- C/
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per-Radiological Assessment recommendation) 5.
Current Piant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
Emergency
-Repairs required (per discussion with Maintenance /Resn'.s).
7.
Personnel Accountability completed (Y/N)
'8.
Personnel Injuries
,o
(,/
a)
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
t.
l:
d)
How many have been sent to hospital?
Which Hospitals?
l e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
D.a FORM (91372 22 3643
RERP-ISC Datasheet 1 Public FORT ST VRAIN NUCLEAR GENERATING STATION Issue 15 i
' ) SGIVICe PUBLIC SERVICE COMPANY OF COLORADO
\\w/ :
s PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
c 1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event 4
t ~.
V 4.'
Radiological Assessment (Attach screen printout from Radiological Assessment-if desired.)
Wind speed at 10 meters
. Stability Category
_ Location of Hazard: From degrees to degrees for miles.
Sectors Affected:
Release Rates (C1/Sec): Noble Gas Radioicdine Total Curies Released:
Noble Gas Radioiodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate o
FO8tM181372 22 3843
RERP-ISC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 O
SerVICO PUBLIC SERVICE COMPANY OF COLORADO V
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
L6.
Emergency Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries 7
a)'
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
l--
d)
How many have been sent to hospital?
l Which Hospitals?
l e)
Relatives of all injured persons notified? (Y/N)
[
If;not, who has not been notified?
l 9.
Plant Evacuation l
l Non-essential plant personnel evacuated from (location) at (time).
Oa l-l FORM (8)372 22 3643
RERP-1SC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
Service PUBLIC SERVICE COMPANY OF COLORADO
[.
PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NDTE:
Attach copies of notification forms complated by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event
()
4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees for miles.
Sectors Affected:
Release Rates (C1/Sec): Noble Gas Radiciodine Total Curiei Released:
Ncote Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate l'^
O FORMiB1372 22 3643
RERP-ISC Datashnet I Public FORT ST. VRAIN NUCLEAR GENERATING STATION lssue 15 Page 2 of 2 SerViCG PUBLIC SERVICE COMPANY OF COLORADO
.h
.x)
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
Emergency.
Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N)
,q -
8.
Personnel Injuries V
a)
Number of injured persons
.b)
Description of Injuries c)
How many of injured persons are also contaminated?
d)
How many have been sent to hospital?
Which Hospitals?
'e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
(3
. r.)
FORMig3372 22 3643
RERP-TSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15
- 9 3 service PUBLIC SERVICE COMPANY OF COLORADO
< (,
- . V PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies of notification ferms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event (J
~
4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees for miles.
Sectors Affected:
l l
Release Rates (Ci/Sec): Noble Gas l-Radioiodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate l
r V
l-l FORMi51372 22 3643
RERP-TSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 service PUBLIC SERVICE COMPANY OF COLORADO s,,
!,)
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the.RERP is": (Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
-6.
Emergency Repairs required (per.
discussion with Maintenance /Results).
7.
Personnel Accountabiiity completed (Y/N) 8.
Personnel Injuries (o.
a)
Number of injured persons
)
b)
Description of Injuries c)
How many of injured persons are also cor.taminated?
d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
FORM #81372 22 3643
RERP-1SC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 e) Service PUBLIC SERVICE COMPANY OF COLORADO
'[)
PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies of notification forms completed by the
- Control Room during initial notifications.)
1.
Date of Event Time of Event
~
2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event qb 4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees for miles.
Sectors Affected:
i.
. Release Rates (Ci/Sec): Noble Gas I
Radioiodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate FOAM t8:372 22-343
r RERP-TSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15
) Service PUBLIC SERVICE COMPANY OF COLORADO r3 N)
" Based upon the projected dose to 1.he population the Recommended Protective Action per Table 6.2-2 of the RERP is":.(Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
Emergency Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries
)
(d a).
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
O FORMt8 372 22 3643
RERP-lSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9
3 Service PUBLIC SERVICE COMPANY OF COLORADO
\\./
PRELIMINARY ASSESSMENT FACT SHEET (To.be given to TSC Director)
NOTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event
.AU
-4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From ___ degrees to degrees for miles.
Sectors Affected:
Release Rates (C1/Sec): Noble Gas Radiciodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate (3
g)
FOR'A t8# 372 *2 3643
l RERP-TSC Datasheet 1
~
Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15
- ) Service PUBLIC SERVICE COMPANY OF COtORADO L.)
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and' Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
quired (per discussion with 6.
Emergency Repairs re Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries
(.)
a)
Number of injured persons b)
Description of Injuries c)
' How many of injured persons are also contaminated?
d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
O f oPM(8i372 22 3643
RERP-ISC D:tasheet l' Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9'
) SerVICO PUBLIC SERVICE COMPANY OF CO:.ORADO
. ;.7
- e.. b PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NDTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY
-GENERAL EMERGENCY 3.
Description of Event oU 4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees ine miles.
Sectors Affected:
Release Rates (C1/Sec): Noble Gas Radiciodine Total Curies Released:
Noble Gas Radioicdine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate
.(
FORMIBl372 22 393
RERP-TSC Datasheet 1 gi Public FORT ST. VRAIN NUCLEAR GENERATING STATION I: sue 15
~
X.) service PUBLIC SERVICE COMPANY OF COLORADO
. e-) :
uJ
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per Radiological Assessment recommendation)
'5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
. Emergency Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries a)
Number of injured persons b)
Description of Injuries c)
.How many of injured persons are also contaminated?
d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of.all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
.O Fo4M t81372 22 3643
hERP-TSC Datasheet 1 5
. Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 J service PUBLIC SERVICE COMPANY OF COLORADO 3 -m
,D PRELI'MINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies o f.
notification forms completed by the Control-Room during initial notifications.)
1.
Date of Event Time of Event 2.
" Based:upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event W
4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10 meters
. Stability Category Location of Hazard: From degrees to degrees for miles.
Sectors Affected:
Release Rates (Ci/Sec): Noble Gas Radioiodine Total Curies Released:
Noble Gas Radioicdine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dose Rate Il
\\.J FORM 1813U D M43
RERP-TSC Datasheet 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 O
ServlCe PUBLIC SERVICE COMPANY OF COLORADO
' c\\
-sj
" Based upon the projected dose to the population the Recommended Protective Action per Table 6.2-2 of the RERP is": (Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
Emergency Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries (9
a)
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
d)
How many have been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
O V
FoRMtst372 22 3643
RERP-ISC Datasheet 1 i
Public FORT ST. VRAIN NUCLEAR GENERATING STATION lssue 15
~3
- 9'
) service PUEsLIC SERVICE COMPANY OF COLORADO I
6 PRELIMINARY ASSESSMENT FACT SHEET (To be given to TSC Director)
NOTE:
Attach copies of notification forms completed by the Control Room during initial notifications.)
1.
Date of Event Time of Event 2.
Based upon the current release and the potential for further release this emergency is classified as":
ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 3.
Description of Event fl v
4.
Radiological Assessment (Attach screen printout from Radiological Assessment if desired.)
Wind speed at 10. meters
. Stability Category
'ocation of Hazard: From degrees to degrees for miles.
Sectors Affected:
Release Rates (Ci/Sec): Noble Gas Radiciodine Total Curies Released:
Noble Gas Radiciodine Dose Rates At EAB (Rem /hr): Whole Body Dose Rate Thyroid Dese Rate
/9' V
FORM (813?2 22 3M3
RERP-TSC Datasheet I
/
Public FORT ST. VRAIN NUCt EAR GENERATING STATION Issue 15 SOTVICO PUBLIC SERVICE COMPANY OF COLORADO s,_
V
" Based upon the projected dose to th'e population the Recommended Protective Action per Table 6.2-2 of the RERP is":
(Reference RERP-PAG per Radiological Assessment recommendation) 5.
Current Plant and Core Status (refer to completed Datasheet 2, supplied by Senior Plant Engineer / Reactor Engineer).
6.
Emergency Repairs required (per discussion with Maintenance /Results).
7.
Personnel Accountability completed (Y/N) 8.
Personnel Injuries
- 7~)
a)
Number of injured persons b)
Description of Injuries c)
How many of injured persons are also contaminated?
d)
How many hate been sent to hospital?
Which Hospitals?
e)
Relatives of all injured persons notified? (Y/N)
If not, who has not been notified?
9.
Plant Evacuation Non-essential plant personnel evacuated from (location) at (time).
O U
FORM 19:372 22 3643
RERP-ISC Datasheet 2 Public FORT ST. VRAIN NUCLEAR GENE.7ATING STATION Issue 15 9
~ $ SefYlCe PUBLIC SERVICE COMPANY OF COLORADO t
't
~
- ( ')
v ASSESSMENT OF PLANT / CORE STATUS" TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER
- NOTE:-
Completion o'f all lines not required. The Datasheet is provided for guidance only, and should be utilized to the extent necessary.
Primary System Date/ Time 1.
Date/ Time of Event 2.
Current Reactor Power 3.
Primary Coolant Pressure psia 4.
Primary Coolant Flow 5.
Operating Circulators A B C D.
Motive Power: Steam Water
. /;
If water, which header? Emer. F.W.
Emer. Cond.
V 6.
Purification train in use A B:. Storage, PCRV, or Ventilation 7.
Indication of fuel damage (Y/N)
RT-9301 reading (RR 93256, pt 10) cpm RT-9301 trend 8.
Is heat removal capability adequate (Y/N) 9.
Can cold-shutdown conditions be met (Y/N)
(Refer to S0P I2-02 or SR 5.1.4-W-P)
- 10. Obtain Technical Advisor assessment sheet data, as required (/)
Secondary System 1.
Loops Operating I II 2.
Feed pumps operating A B C 3.
Feed to S/G's Norm F.W.
Emer. F.W.
I Emer. Cond.
g-~3 N) 4.
Secondary flow I K1b/hr.
II k1b/hr.
FopMit:34.u 3H3
RERP-TSC Datashest 2 FORT ST. VRAIN NUCLEAR GENERATING STATION issue 15
@ Public 9'
SerVICO PUBLIC SERVICE COMPANY OF COLORADO
- =
().
5.
Status of~ aux. boilers.
.v 4
l f
t O
l ronuisim.22.aus
RERP-TSC Datasheet 2
. Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 3 of 3 SerVICO PUBLIC SERVICE COMPANY OF COLORADO
',s
%s ASSESSMENT OF PLANT / CORE STATUS TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER Remarks Time Description
)
v L
FORM 181372 22 360
RERP-15C Datasheet 2 FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Public _
~
O service PUBLIC SERVICE COMPANY OF COLORADO m.) -
ASSESSMENT OF PLANT / CORE STATUS
- TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER
^
- NOTE:
Completion of all lines not required. The Datasheet is provided for guidance only, and should be utilized to the extent necessary.
Primary System Date/ Time 1.
Date/ Time of Event 2.
Current Reactor Power 3.
Primary Coolant Pressure psia 4.
Primary Coolant Flow 5.
Operating Circulators A B C D.
Motive Power: Steam Water g
If water, which header? Emer. F.W.
Emar. Cond.
t 6.
Purification train in use A B: Storage, PCRV, or Ventilation 7.
Indication of fuel damage (Y/N)
RT-9301 reading (RR 93256, pt 10) cpm RT-9301 trend 8.
Is heat removal capability adequate (Y/N) 9.
Can cold-shutdown conditions be met (Y/N)
(Refer to SOP 12-02 or SR 5.1.4-W-P) 10.'
Obtain Technical Advisor assessment sheet data, as required (/)
Secondary System 1.
Loops Operating I II 2.
Feed pumps operating A B C 3.
Feed to S/G's Norm F.W.
Emer. F.W.
Emer. Cond.
g 4.
Secondary flow I K1b/hr.
II kib/hr.
FORMttl372 22 3M3
,~
RERP-TSC Datasheet 2 g'An Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 f
- 9'
%)7 Service
' PUBLIC SERVICE COMPANY OF COLORADO 27 C/
\\
5.
Status of aux. boilers.
l 4
c i
O soavie m 22. sus
RERP-ISC Datasheet 2 r-PubllC FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Service PUBLIC SERVICE COMPANY.OF COLORADO V
ASSESSMENT OF PLANT / CORE STATUS TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER Remarks Time Description
[ )
%d A
FOAM 196372 22 3643
RERP-1SC Datasheet 2 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 s> Service PUBLIC SERVICE COMPANY OF COLORADO t
)
ASSESSMENT OF PLANT / CORE STATUS
- TECW'ICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER
- NOTE:
Completion o'f all lines not required. The Datasheet is provided for guidance only, and should be utilized to the extent necessary.
Primary System Date/ Time 1.
Date/ Time of Event 2.
Current Reactor Power 3.
Primary Coolant Pressure psia
'4.
Primary Coolant Flow 5.
Operating Circulators A B C D.
Motive Power: Steam Water q
If water, which header? Emer. F.W.
Emer. Cond.
6.
Purification train in use A B: Storage, PCRV, or Ventilation 7.
Indication of fuel damage (Y/N)
RT-9301 reading (RR 93256, pt 10) cpm RT-9301 trend 8.
Is heat removal capability adequate (Y/N) 9.
Can cold-shutdown conditions be met (Y/N)
(Refer to SOP 12-02 or SR 5.1.4-W-P) 10.'
Obtain Technical Advisor assessment sheet data, as required (/)
Secondary System 1.
Lceps Operating I II 2.
Feed pumps operating A B C 3.
Feed to S/G's Norm F.W.
Emer. F.W.
Emer. Cond.
q 4.
Secondary flow I K1b/hr.
II kib/hr.
~
FORMIBl372 22 >A1
RERP-lSC Ditasheet 2 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0 Service 9
PUBLIC SERVICE COMPANY OF COLORADO s
V' 5.
Status of aux. boilers, b'
V).
FORMib)372 22 3643
RERP-TSC Datasheet 2 i
Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 O
) Service PUBLIC SERVICE COMPANY OF COLORADO
=
f N, i)
ASSESSMENT OF PLANT / CORE STATUS
-TECHNICAL' SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER Remarks Time Description s
\\
y,i
_/'
FOAM (81372 22 3043
RERP-ISC Datasheet 2-
) Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 S'
jfSerVICe PUBLIC SERVICE COMPANY OF COLORADO
, o V
ASSESSMENT OF PLANT / CORE STATUS
- TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER
- NOTE:
Completion o'f all lines not required. The Datasheet is provided for guidance only, and should be utilized to the extent necessary.
Primary System Date/ Time 1.
Date/ Time of Event 2.
Current Reactor Powei 3.
Primary Coolant Pressure psia 4.
Primary Coolant Flow 5.
Operating Circulators A B C D.
Motive Power: Steam Water
(-')
If water, which header? Emer. F.W.
Emer. Cond.
v 6.
Purification train in use A B: Storage, PCRV, or Ventilation 7.
Indication of fuel damage (Y/N)
RT-9301 reading (RR 93256, pt 10) cpm RT-9301 trend 8.
Is heat removal capability adequate (Y/N) 9.
Can cold-shutdown conditions be met (Y/N)
(Refer to SDP 12-02 or SR 5.1.4-W-P) 10.'
Obtain Technical Advisor assessment sheet data, as required (/)
Secondary System 1.
Loops Opertting I II 2.
Feed pumps operating A B C 3.
Feed to S/G's Norm F.W.
Emer. F.W.
Emer. Cond.
4.
Secondary flow I K1b/hr.
II k1b/hr.
FORM 181372 22 3643 i
RERP-TSC Datasheet 2 FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15
@ Public O'
SerVICO PUBLIC SERVICE COMPANY OF COLORADO 5.
Status of aux. boilers.
O 4
e p
FORM it 372 22 3443
RERP-TSC Datasheet 2 Public FORT' ST. VRAIN NUCLEAR GENERATING STATION Issue 15
@'. ServicePUBLIC SERVICE COMPANY OF COLORADO
/"%.
L.)
ASSESSMENT OF PLANT / CORE STATUS TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER Remarks Time Description t'N -
U f
l.
J FORM '6:372 3643
RERP-ISC Datasheet 2 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9'
service PUBLIC SERVICE COMPANY OF COLORADO
, (3i w
ASSESSMENT 0F PLANT / CORE STATUS
- TECHNICAL SERVICES ENGINEERING SUPERVISOR / SENIOR PLANT ENGINEER
- NOTE:
Completion o'f all lines not required. The Datasheet is provided for guidance only, and should be utilized to the extent necessary.
Primary System Date/ Time 1.
Date/ Time of Event 2.
Current Reactor Power
-3.
Primary Coolant Pressure psia 4.
Primary Coolant Flow 5.
Operating Circulators A B C D.
Motive Power: Steam Water
[3
. If water, which header? Emer. F.W.
Emer. Cond.
<>~
6.
Purification train in use A B: Storage, PCRV, or Ventilation 7.
Indication of fuel damage (Y/N)
RT-9301 reading (AR 93256, pt 10) cpm RT-9301 trend 8.
Is heat removal capability adequate (Y/N) 9.
Can cold-shutdown conditions be met (Y/N)
(Refer to 50P 12-02 or SR 5.1.4-W-P)
- 10. Obtain Technical Advisor assessment sheet data, as required (/)
Secondary System 1.
Loops Operating I II 2.
Feed pumps operating A B C 3.
Feed to S/G's Norm F.W.
Emer. F.W.
(l Emer. Cond.
'w; 4.
Secondary flow I
_,K1b/hr.
II
__ kib/hr.
FoRMtel372 22 3M3 1.
^
4 RERP-TSC Datasheet 2 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 2 of 3 Service rustic ssRviCE COMPANY OF COLORADO
(.y y 5.
Status of aux. boilers, k'.
i l-e n
I
(
i I
l A
c
's,1 -
FORM EBi372-l2 3043
- l...
_ ~. _...... _.. _ _ _ _ _ _ _ _. _., _, _ _ _ _ _ _ _ _ _,
RERP-TSC Datasheet 2
& Public FORT ST. VRAIN NUCLEAR GENERATING STAllON Issue 15 9
107 Service PUBLIC SERVICE COMPANY OF COLORADO OV ASSESSMENT OF PLANT / CORE STATUS TECHNICAL SERVICES ENGINEERING SUPEliflTOR/SENIT)R PLANT ENGINEER Remarks Time Description n
l
~n L.)
FORMi51372 22 3643
~
RERP-TSC Datashaet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15
@ SerViCO Page 1 of I PUBLIC SERVICE COMPANY OF COLORADO y
t
)
'/
-1J
..-t I :: r : :.
5-2 t
t t
E
..it1 a
.!!il-2 [ r.; :.
- E " 3 3 3 33-r 2
- II e s
.:.a 3~::
--er 8
i s
a I
s F
i.
g-g 3j 1
l I!!
i 5
!!H!
-1 m.
1.-
1 s-15 1
g e
.s O
-I l
5 v
o o
g a-I'j!-.
- .e!
s
}
[
3 e
t 5
2 12: ::
r 1:e
(
i s-a-
s
- 1
-)l. 8:ini r
.el.
e.s.
l 3
3 e
r 1
s.
3' fillII;"jil 8
I g:
s-: : e
- .eg
)::
I II; a
.2
- es 3
,!.!)e-r:
.i
.2
&I.2
- a a m e u y~&
~
Iw/
FORM t0 372 22 364
REie-15C Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Service PUBLIC SERVICE COMPANY OF COLORADb Page 1 of 1
/~N V
s:.
1.! : : :.
m1 t
- .I..
- 3 I
.!I,:ga n
- Err.=&=3 33
- 3-:
2 11
=
..r.i..
5
- r-1:
8 I
.s
.a s.
3 k
4
~.
---3 5
l
!!!1 2I s
[
I 75 :
g.e V g.
sa -
a s
a
.a
-3 3.
3 2
3 s
-s s
i
. -(v i
_1 5
3
=
o o
r 8
i e_
g
.e
)
l_!
l
_g
-_8 s
e l ::.g s: - : a:
l
_ p _- -
3:
a
--4 a
i
-.[. -
s1j
- _ 5 _E : :
2= r 2
r.=:
I 2!!3!!;"j31 I
8: E:
Ilg!
I g:
s-: : ese:,eg jm: l-3
- ::::=
3. a... ! ;= _r :....
.s i g !._g l. e y i
sm
\\
ku 4
FORM (Si372 22 3643
Rf.RP-15C Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of 1
\\
SerVICO PUBLIC SERVICE COMPANY OF COLORADO f'st
,v 1J 3 : : :: :.
- ,tt
, 8 1 : n. i
.; 13 s,-z."
n: :
- _g e r. = f u e
s ss
-_3
- p 8
s I
c 1
3 8
4
---I 5
8 l
55 l
-l I
5555
.-as :
!.E!
=
z a
r
.s
-p 1
s.
m
'8 11
- f e.
.s I
I
/^%
a
(
v o
o z
s z-
,j g
=
s
-I!
-[
_g
=
s e8:: I::::
,I I:
g :g-s--:
-a I
i e
s.ga.j2rri2 _ 5 _g - rI m
5
.r I
e s :! :
1 l
2*
- 2333f:
- . e.:;j31 8:
,5 :: I.
{ t :a I
tr _:
- s:1 s:: : : : I s 1 :: ! :I
! ! 5.g :r y. I e
e
-=
i i
e-
.i:::
=
V
=_
FORMi81372 22 3643
L RERP-15C Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of 1
) Service PUBLIC SERVICE COMPANY OF COLORADO
., -lV 4
4: :
2 : tt
- : [=
-1jt 32]:.
m
=
N: 22 Og
.*:*2o* I.1 1 2 l?:. *
- 2 l :
a.
=
s l
3 e
G 2
2 e
~
i s
- -3 111 8
a 2 z2:
a3
===-
s=. 2 x:ga w
1 c --
-1
=. 1 s
3
,i s
g I
I v
=
o o
a
=
5'i 5
I 3:
I, a
t je
.e:
28
-l i
- !:.. i : s :s.
n s
fue r:
y
- .g:-
=
- s s1 ag e
- e. 1. _. 8 :
a s
s r
s1 i
_ _ 2_ _: _=,
- a..
a 1:
j1!
I
!i gil!!!;"jil 8
- s. i. l.: __g 3
p2 s-: : e
- .eg se':
- : : : :=
......1a2 ej r
, a e
!m\\
V FORf.'tEl372 22 3643
RERP-1SC Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of I Service PUBLIC SERVICE COMPANY OF COLORADO 9
I
'\\)
I t.:
- I 3
..f*
1 <: 8 : -
.I 8
ily
. S ~: l
.a
- , ] t. h *,!. - -
- xx 2 lNN
- _l r Y 2
..r:**t*2oI.t.3 0-2
-1 m
I~
e a m E
g 1
E I
l l
p
[ :,
n 21 3
8 1
111 7
- 3 y
[
2 22:
2 t
- . I :..:
=, ;
g E
E
.t, Y E
- 2 5s e
i s
g,
-il a -
'I il 1
g e
a e
(,
.,s J
l u
e 2
5 a
a g
=
I 2*.
I 2
6 6
)
[
i y:
3
$-l3:r.e.l::
!5 l
g I
s:e_
s
--a.:
2 a
i E
.g -
s1]11 11 caj 5r 2
et==
1 s
2*
ns!!3.31:"j31 1
8 a
I:A If : E.23,g
- 1 eI 2
l g: .!: :Ig 2 32 X X: 2 2 2.g 5 I' ;f a 2 $j g :I }. 5 { .2 s - E y.A t \\ ' FORMl81372 22 3!,43
RERP-15C Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of I 4 Service PUBLIC SERVICE COMPANY OF COLORADO . gl \\v
- J 1 : : :: :.
.: : 1: ..; } } 8 1 : : =y =- 3
- 7":
= a 7 *::
- 11 2: ?:
- t"
-..r.. . _ j.i s : _g o_
=
i [ es 3 Ia
- : :1 s
1 a 2
- 3 31 l
..a : g.eV3 is : a z e 1 .- s_ -g
- 3. >
.-s t u l g (v) o o a 3 p = i ra_ - us a: t g l_! l g 3_ :;
- _g :.r : -
,r, = m g r 8 s_ --a m
- I sr salvris::
-c a 3-23 t: :: I
== 1 l 2* =2333!:"j!I 8: Ee 9 _: 2.:
- : eE 3 ::, 1 j
22. 3.: s
- : : 2 ::::!:
-l._ g ::
- 4 art:
g!8 8: !.1 i 5a e a t l. I a l FORMfB)372 22 3643
RERF-TSC Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of 1 SOTVICO PUBLIC SERVICE COMPANY OF COLORADO <p kx_s i .ee 3 : : :: :. .m: tt g. *[2 - j..e .21 ,s 5,: 3: 3 3 . U*2 til 2 t:. - - f" 3.l.T...J.= - 3 o!.: 3: 8 [ t: y } ia 8 m 8-l z= -l s1 2 s: : EE : E o .s 'i! 5" 11 1 -a I 6 f E, 5 (a) I -i o o I 5 ~ j e a I EE - 1 f: s s l 1 I l 2 s
- 8: -. ! : :: :: ::
fie r [ s: a-
- : s ge,g. 8::n r a,g s!
= e 5
- :13j
- sI 3
i a: 3.: -r8 '8: 1 18 o g ,5 ::,g.-. 1: -i. v:
- : e
! : e :: a:
- 2 :
- ! e. 8
- 8 :..
4
- : : :::sti: :
5a e a I \\ y Fr.RM tBl372 22 3H3
RERP-TSC Datasheet 3 I. Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of 1 \\ ) Serv. ice PUBLIC CERVICE COMPANY OF COLORADO , -s) C%. 1J m: 1: . ! ] :: :t. -3.. p$*,m
- 3
- xx
- 'l1
- !. 2 :
2
- rs:..
- ._iof.: :
2: g-5 3 E 2 Ia 2 5 23 2 l e 3.I3
=
2 8 I 2 i? -l.
- z. -
5. -3 g (._) - i 1 5 o o 2 5 = = 21. j:: l 3 s i j e .e si i s g i _. t : :: :5.. l:e r: [ l s: 1-
- =5 3::e
- i e
..s r
- e. : :
g 3 i ij slilil1 jii 1j!!5 j1i i g: 5: : e: e; 8. 3 .3 e==2 3. es: I
- 2 : : : :
.i : 8. .: e. J 3..... II:.: y a .i { s 4 b FORM (Bs372 22 393
kERP-15C D2tasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 / Page 1 of 1 service PUBLIC SERVICE COMPANY OF COLORADO <,.3 \\v) e ..er 1.: :I e. -
- =
- t tt t
- all i.
ra
- I :: 8, c: --
- o
<t[ eI:33 .Ee. a ! :: 4.,.: --gr -a B E S 3 3 3 E I*:, t ~. 1 = ? E 112 l 3j u 222
- .3
...=
== 2 .x : I a
- B
= = a gu -- ._i! ii
- 11 9
-R 33 J a t 6 f 4. 5 m e (v) E = o o z i I a: l' _ ! -l - l I g
- :g::t r
r g 3 :j. e-33 2 s i l 't r i m ; e m :l g s r
- 5. r a.:: m-c:::
I 3: =!!!31:"j31 1 g ::, 1-j _ :a: 3:. 3.: f:
- 3I m
e e-g ::
- : : s i :r : ::
! !. g :r i. l r. i
- a
.5a a 50RM t81372 22 3643
RERP-TSC Datasheet 3 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 Page 1 of 1 SerVICO PUBLIC SERVICE COMPANY OF COLORADO . r%, n (,/ 3 : : :: :. m: :: ,; }.t
- ..g,
.!!:,y I
- 7:
7: mx ..a s=1I 2 e:.= e s.i . !.. 21 s*{js: E E. 3 3 i e. 2 A g
- 1
{ 1 I .= 5 s n 1 11 2 * ,. I ge..m -.g-va ~ w d" - -t 5. 4. f ,,) .a di 5 5 l t = ~ = z 3 = = 5 'I :i 5 A I .e _i s_ j e g r _. t : :: :s ! a e r i 1:e ar .g : ) s1 5 J. 8: - ag --!'eI i 2: [? ii !!!:!j:js ir
- : l al 8: n-f.y_ :::
I eI 1:: 0: 2 .s !es::!=
- e-r 5I UI:::
I! 8:: I-.I 8 g :: i a 6 ) sonutss372 22 3643
RERP-TSC Checklist 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 b SerVICO PUBLIC SERVICE COMPANY OF COLORADO , (- ' \\) TSC CHECKLIST To be completed by Admi.nistration/ Logistics support personnel. TIME ~1. Habitability verified. 2. Sign-in sheet (Attachment 2) set up by door. 3. Dosimeter assigned to TSC general area to monitor overall personnel exposure. . 4. Control Room television set up. 5. Copy of-completed notification form obtained from Control Room. 6. Preliminary Assessment-Fact Sheet (Datasheet 1) completed and submitted to TSC Director. 7. Center' accountability complete: bp TSC Director Technical and Engineering Analysis Radiological Assessment Plant Condition Assessment Sr. H. P. Representative 4 Emergency Maintenance I&C Administration / Logistics Computer Support Technical Support - 8. TSC activated; initial staff briefing conducted. 9. Communications established Control Room Personnel Control Center e Forward Command Post
- 10. Plant Status' board updated.
- 11. Radiological Status Board updated.
O Fomuten372 22 3843 s_
RERP-lSC Checklist 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 0 Service 9 PUBLIC SERVICE COMPANY OF COLORADO '(3 %)
- 12. Personnel Accountability Status obtained Verify that Visitor's Center notified Initial (from' Shift Supervisor -
may pass through the CR Director) Continuing (from PCC Director)
- 13. Injury Reports transmitted to FCP.
- 14. PCC evacuation recommended.
- 15. Requests for Additional Personnel Made Site Personnel Other PSC Contract
- 16. In-Plant Survey Teams Status Dispatched Report Received
- 17. Site Survey Teams Status Dispatched Report Received
- 18. Exposure criteria for emergency workers being followed (see RERF-EXP) a
~ FORMfB)372 22 3843 L_,
RERP-TSC Checklist 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9 SeTVice PUBLIC SERVICE COMPANY OF COLORADO (~3 _ ' %.) TSC CHECKLIST To be completed by Admi.nistration/ Logistics support personnel. TIME 1. Habitability verified. 2. Sign-in sheet (Attachment 2) set up by door. 3. Dosimeter assigned to TSC general area to monitor overall personnel exposure. 4. Control Room television set up. 5. Copy of completed notification form obtained from Control Room. 6. Preliminary Assessment Fact Sheet (Datasheet 1) completed and submitted to TSC Director. 7. Center accountability complete: 'O TSC Director Technical and Engineering Analysis Radiological Assessment Plant Condition Assessment Sr. H. P. Representative Emergency Maintenance I&C Administration / Logistics Computer Support Technical Support 8. TSC activated; initial staff briefing conducted. 9.- Communications established Control Room Personnel Control Center Forward Command Post
- 10. Plant Status Board updated.
- 11. Radiological Status Board updated.
f-C FoRMiBP372 22 3643 L
RERP-TSC Checklist 1 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Issue 15 9 ) Service PUBLIC SERVICE COMPANY OF COLORADO V
- 12. Personnel-Accountability Status obtained Verify that Visitor's Center notified Initial (from' Shift Supervisor -
may pass through the CR Director) Continuing (from PCC Director)
- 13. Injury Reports transmitted to FCP.
- 14. PCC evacuation recommended.
- 15. Requests for Additional Personnel Made Site Personnel Other PSC Contract
.16. In-Plant Survey Teams Status (~~\\ v' Dispatched Report Received u
- 17. Site Survey Teams Status Dispatched Report Received
- 18. Exposure criteria for emergency workers being followed (see RERP-EXP) l l
I FORM 181372 22 3643
PUBLIC SERVICE COMPANY OF COLORADO RERP Phone Lists Issu2 26 FORT ST. VRAIN NUCLEAR GENERATING STATION Page 1 of 70 (A,PQRT;st..vaAmWW* ((; n ..a TITLE: RADIOLOGICAL EMERGENCY RESPONSE PLAN (RERP) PHONE LISTS Ntk . At,., , O, e - :"twv meus:_, ((h m4 ENTER. v.stARM M mty l (h k -[m sm,N-ISSUANCE 'i g;jj7, y AUTHORIZED / BY C ,b ~ 4 fys**E
- "L"w Q PORC y/ '
EFFECTIVE REVIEW M DATE 3-ll-$$ TABLE OF CONTENTS Pace 1. Fort St. Vrain Phone System 2 2. RERP Phone List Index 3 3. Company Operator's Call List 5 ,J 4. ECP Director's Call List 9 5. FCP (CED's) Call List 11 6. PCC Director's Call List 13 7. State EOC Call List 16 8. TSC Director's Call List 18 9. Command Centers / Posts Numbers 21 10. Outside Assistance Numbers 25 11. Visitor's Center 27 12. RERP Phone List 28 w/ 8 FORM 372 22 3642 l-
RERP Phone Lists Issue 26 0 SerVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 2 of 70 PUBLIC SERVICE COMPANY OF COLORADO , () FORT ST. VRAIN PHONE SYSTEM DIMENSION SYSTEM DIALING INSTRUCTIONS From Fort St. Vrain: Area to be Called Proper Dialing Prefix Denver Exchange PSCo number 8 + Number Outside PSCo 8 + 303 + Number Longmont Exchange 78 + Number Greeley Exchange 9 + Number All other areas in Colorado 8 + 303 + Number Outside the State of Colorado 8 + Area Code + Number (unless a toll free number) Paging Using Phone System: To Page: Dial 60-0 (all areas) or 62-@ (in plant only) (d @ = (1, 2, 3, 4, 5, 6, or 7) whichever "@" is used, annouice " CODE @" after page is complete, depress switch once, wait for answer. To Answer: Dial #7-@ @ = (1,2,3,4,5,6, or 7) in place of "@", use whichever code number was announced. O %d FORM tC)'J12 22 3643 L
RERP Phone Lists Issue 26 O Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 3 of 70 PUBLIC SERVICE COMPANY OF COLORADO V
RERP PHONE LIST INDEX A-Personnel Control Center Procedure (RERP-FCC), Checklist 1 B-Deleted C-Significant Event Notification to American Nuclear Insurers D-Control Room Procedure E-Control Room Procedure, Attachment #1 F-Control Room Procedure, Attachment #3 G-Control Room Procedure, Attachment #4 H-Control Room Procedure, Checklist #2 I-Personnel Control Center Procedure, Attachment #2 J-PSC Company Operator Call List' K-ECP Director's Call List
- q%.)
L-Corporate Emergency Director's Call List
- M-PCC Director's Call List
- N - State EOC Call List
- O-TSC Director's Call List
- P -' Centers / Posts Phone Numbers Q - Outside Assistance Phone Numbers R-Visitor Center Phone Numbers S-Fort St. Vrain Medical Emergency Plan T-Oil Spill Prevention, Control and Countermeasure Plan (SMAP-10)
U-Automatic Dialing System (Shift Supervisor's Office and Control Room) These call lists are found in both RERP-PHONE LISTS and RERP-HOME. FORM (Cl372 22 3643 L
RERP Phone Lists Issue 26 0 Service" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 4 of 70 - PUBLIC SERVICE COMPANY OF COLORADO ,b,__ ~ V-Home Packet For Off-Shift Notifications (RERP-HOME), Table #1 l W-Home Packet For Off-Shift Notifications (RERP-HOME) Attachment #3 X-Home Packet For Off-Shift Notifications (RERP-HOME), Attachment #4 Y-Home Packet For Off-Shift Notifications (RERP-HOME), Attachment #10 Z-Home Packet for Off-Shift Notifications (RERP-HOME), Checklist #1 . (- U O FORM (Cl372 22-3643 L'
RERP Phone Lists Issue 26 0'SerVlCe* . Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 5 of 70 PUBUC SERVICE COMPANY OF COLORADO 'U RADIOLOGICAL EMERGENCY RESPONSE PLAN PSC COMPANY CPERATOR CALL LIST A. Obtain the following information from your contact at Fort St. Vrain. a. Name and identity of caller: b. Date/ Time of event: c. Classification of event (circle one): Radiological Alert ~/ Site Emergency General Emergency d. At the present time, a radiological release (circle one) IS/IS NOT occurring. mb e. Location of the Personnel Control Center B. Your Name: Date/ Time call was received: l l l L FORMIC)372-22 3643 -
RERP Phone Lists Issue 26 0 ServlCG" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 6 of 70 PUBLIC SERVICE COMPANY OF COLORADO , 7. s $.] PSC COMPANY OPERATOR CALL LIST (continued) C. Fill in the blanks of the following statement which will be read verbatim to the individuals on your call list using the above information. READ SLOWLY At approximately (b) this date at the ~ Fort St. Vrain Nuclear Generating Station near Platteville, Colorado, an event believed to involve a potential radiological hazard occurred. This event has been classified as a (c) At the present time, a . L.')i radiological release (circle one) IS/IS NOT occurring. The Personnel Control Center is to be established at (e) l I D. IMMEDIATELY, (day or night) contact the following individuals and read them your prepared statement verbatim. Log the time each is reached. 1. Call Fort St. Vrain and verify the report: a. Call '5-785-1220. Read your prepared statement VERBATIM. 2. Colorado State Health Department: a. Duty Hours: 320-8333, Ext. 6246. () FORM (C)372 22 3643
RERP Phone Lists Issue 26 0 Public FORT-ST. VRAIN NUCLEAR GENERATING STATION Page 7.of 70 $9tVICe* PUBLIC SERVICE COMPANY OF COLORADO U,s b. After duty hours: 320-1465 (this is an answering service and they will contact the on-duty person at the State Health Department). .s (G i O. V FORM tC)372 22-3643
,_ _ _ _. ~ 4 ~
- 1 j~m e
lY^ ~ N.) l P s RERP Pil0NC" LISTS issuo 26 i. Page 8 or 70-. i PSC COMPANY OPERATOR CALL LIST-IContinued) D. .(Continued) 3. Contact one oLeach of the following groups or primeries/ alternates. Extension City-Hong Time a. Prima ry: J. W. Cahm' 5-785-1200 - No rthg lenn 5-303-452-0507 Alternate: C. H. Fuller 5-785-1202' - Loveland 5-303-663-2363-b. Prima ry: W. J. F ranek 5-785-1218 Berthoud 5-303-532-3489 Alternate: D. P.' Hood 5-785-1347-Longmont 5-303-776-1843 c. Prima ry: J. Class' 5-785-1253 Brighton 5-303-659-4118-Al te rna te: S. R. Wi l l fo rd 5-785-1450 Brighton - 5-303-659-5258 d. Prima ry: F. J. Novachek 5-785-1201 Thornton' 5-303-457-8034 At le rna te: D. W. Warenbourg 571-8419 rede rick 5-303-833-4092 Al te rna te: L. W. Singleton. 5-785-1350 Longmont 78-772-1018 e. Prima ry: 0.'R. Lee 571-7105 Brighton 9-659-1180 t Al te rna te: J. K. Fuller-329-1104 Denve r 9-779-1109 j r. Prima ry: R. F. Walker $71-7333 Denve r - 9-234-9298 j Alternate: B. O'Donnell 571-7381 Denve r 9-388-0211 g. Prima ry: D. McNollis 571-7254 Denve r 9-321-3142 l Alternate: H. L. Brey 571-8404 B roomfie ld 9-469-4238 3 4. Contact America.. Nuclear insurers 1-800-243-3172, (203) 677-7305, or (203) 67F-7315 (Day or Night) 5. Contact Ceneral Atomic Technologies, Inc. (619) 455-2010 a 1 6. Contact one or the rollowing et the Colorado State University Radiation Biology Department. Work City. Hong lino 6 i a. Dr. James E. Johnson 5-303-491-5380 ft. Collins 5-303-482-3029 b. Harlon Mcdonald 5-303-491-5094 Ft. Collins 5-303-484-0084 c. Depa rtment' Orrico 5-303-491-5222 It. Collins j 7. Contact American Nuclear Society 1-800-323-3044, (312) 352-6611, or (312) 352-6814 (24-hour emergency) 8. NRC Resident inspector - Orrice 5-785-1490 or 5-303-785-2282 - G. L. Plumloe, III 303-776-9541 or 890-2225 ( Page Number) } 9. Contact institute of Nuclear Power Operations (INPO) (404) 953-0904 or 953-0922. . Contact PSC Inrt St. Vrain Shirt Supervisor at 5-785-1219 to report results of telephone contacts above. i d
e RERP Phone Lists Issue 26 O SerVICO* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 9 of 70 PUBUC SERVICE COMPANY OF COLORADO V ECP DIRECTOR'S CALL LIST INTRUCTIONS In the event that you are. notified by the PSC operator that a Radiological ALERT or higher classification event has occurred at Fort St. Vrain, complete the following telephone calls: 1. If you are the response center / post Director: a. Call your response center / post Alternate Director (and the alternate will complete the calls on the attached list). b. If you cannot contact your Alternate Director, call the first person on the attached list and inform him to complete the call list. 2. If you are the response center / post Alternate Director and are contacted by the Director: a. Complete the attached call list. 3. If you are the response centar/ post Alternate Director and are contacted by the PSC Operator: -b' a. Call the first person on the attached list and inform him to complete the call list. I l O FORMICI372 22 3643 i
RERP Phone Lists Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 10 of 70 PUBLIC SERVICE COMPANY OF COLORADO
.p,V ECP DIRECTOR'S CALL LIST First call all primaries, then call all alternates. PSC Extension Home Time Manager - Technical Support l Alternate - J. R. Reesy 571-8406 755-1720 l Primary - M. E. Niehoff 785-1403 690-3879 Manager - Media Relations Primary - R. T. Person, Jr. 571-7323 753-9292 Alt. - W. D. Fitzmaurice 571-7713 424-8053 (~\\ -)/ m Manager. Resources Primary - D. D. Hock 571-7211 394-3063 Alternate - J. Bumpus 571-7821 388-7645 Manager - Security l Primary - E. O'Neal 571-7709 757-0038 Alternate - E. Lane 571-8533 321-4016 l Alternate - D. Amick 571-7898 772-9378 Note: Any change to this call list requires a change be made to RERP-HOME, Attachment #5. AV FORM tCl372 22 3643
r REk/ Phone Lists Issue 26 0 SOTVICO Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page II of 70 PUBLIC SERVICE COMPANY OF COLORADO ,(/ CORPORATE EMERGENCY DIRECTOR'S CALL LIST INSTRUCTIONS In the event that you are notified by the PSC operator that a Radiological ALERT or higher classification event has occurred at Fort St. Vrain, complete the following telephone calls: 1. If you are the response center / post Director: a. Call your response center / post Alternate Director. b. If you cannot contact your Alternate Director, call the first person on the attached list - inform and him to complete the call list. 2. If you are the response center / post Alternate Director and are contacted by the PSC Operator or the center / post Director: a. Call the first person on the attached list and -inform him to complete the call list. 3. If you are the first person on the attached list and are (~)' contacted by the Alternate Director or the Director: x. a. Complete the attached list. l b) \\.) FOAM (C)372 22-3643
RERP Phone Lists Issue 26 0 service Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 12 of 70 PUBUC SERVICE COMPANY OF COLORADO Ig CORPORATE EMERGENCY DIRECTOR'S CALL LIST (FCP) First contact all primaries, then call all alternates. Extension Home Time Station Technical Liaison (One of the Station fechnical Liaisant is also contacted by the PSC Operator.) Orimary - F. Novachek 785-1201 457-8034 Alternate - D. Warembourg 571-8419 833-4092 Alternate - L. Singleton 785-1350 772-1018 Radiological Assessment Primary - T. Borst 785-1203 663-1230 (Pager) 890-1775 Clerical Assistance Primary - D. Merritt 785-1271 737-2339 Primary - D. Reichardt 785-1272 776-7435 ,-(}) Alternate - S. Katcher 786-1212 356-0351 Media Relations Primary - M. Mora 571-8462 694-2369 Alternate - S. Volsted 571-7242 750-1785 l Security Support l The following individuals report to the ECP but require access .l to the FCP. One of these individuals will then report to the l FCP, in most cases. If assistance is needed, call the ECP at l 571-8461. l D. Amick 571-7898 772-9378 l E. Lane 571-8533 321-4016 Note: Any change to this call list requires a change i made to RERP-HOME, Attachment #6. f~U) FORM (C)372 22 3643
RERP Phone Lists Issue 26 0SerVlCe* Public FORT ST, VRAIN NUCLEAR GENERATING STATION Page 13 of 70 PUBUC SERVICE COMPANY OF COLORADO ud PCC DIRECTOR'S CALL LIST INSTRUCTIONS In the event that you are notified by the PSC operator that a Radiological ALERT or higher classification event has occurred at Fort St. Vrain, complete the following telephone calls: 1. If you are the response center / post Director: a. Call your response center /past Alternate Director (the alternate will complete the calls on the attached list). b. If you cannot contact your Alternate Director, call the first person on the attached list and inform him to complete the call list. 2. If you are the response center / post Alternate Director and are contacted by the Director: a. Contact persons to set up the facility by calling those individuals denoted by asterisks (*) after their names and four (4) Health Physics Technicians l (,j. PCC. Notify the remainder of personnel upon your listed. Inform all persons of the location of the arrival at the PCC. (This responsibility may be delegated.) 3. If you are the response center / post Alternate Director and are contacted by the PSC Operator: a. Call the first-person on the attached list and inform him to complete the call list as specified in Z.a. above. B i N.] FORMICl372 22 3643
RERP Phone Lists Issue 26 0 Service Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 14 of 70 PUBUC SERY:CE COMPANY OF COLORADO ,N). PCC DIRECTOR'S CALL LIST NOTE: The following are preferred assignments only; actual personnel assignments at the PCC may differ, Plant Extension Home Time Personnel Assignment Controller R. Rivera* 453 8-303-667-1906 Recorder / Communications S. Lehr 451 8-303-422-1280 T. Shafer 457 8-303-663-4862 D. Horihan* 250 78-776-7976 l D. Belgard* 445 78-678-0355 Personnel Accountability M. Blossom
- 261 9-785-6302 l
G. Powers 252 9-356-5256 ~~s 'J Decontamination R. Hooper
- 458 8-303-452-3614 M. Murphy 454 8-303-279-6726 Drivers P. Bearly*
455 8-303-669-6636 R. Hamblin* 254 8-303-667-1703 H. Wiedrich 452 8-303-732-4497 First Aid C. Harding-311 9-785-2398 J. Switzer* 452 9-587-4134 D. Reed 314 9-785-2159 Friskers R. Moler* 456 78-772-9354 W. Holcomb*. 319 8-303-778-7702 K. Hays 312 9-330-2068 -L) FORM (C)372 22 3843
Y RERP Phone Lists Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 15 of 70 PUBLIC SERVICE COMPANY OF COLORADO
%l Access Control R. Erwin* 315 9-330-7178 R. Teel
- 261 8-303-288-1959 R. Widows 314 8-303-663-1080 Maintenance, Repair, and Damage Control R. Webb*
299 78-667-8219 (Pager) 855-7257 R. Lamb
- 336 78-772-0757 C. Schmidt*
286 8-303-666-6955 Monitoring Teams - Health Physics (Notify four of the following initially.) J. Brown 245 9-339-3972 P. Glahn 245 8-303-450-5292 L. Hutchins 245 9-330-7187 G. Madison 245 8-303-833-2278 K. Morse 245 9-353-6163 K. Nasveschuk 245 78-651-6254 E. J. O'Donoghue 245 8-303-452-3514 S. Sherrow 245 9-353-1338 ,_s / ) S.' Sieg 245 8-303-663-3468 G. Valentine 245 8-303-223-7674 Radiochemistry V. McGaffic (P)* 278 9-587-2752 l D. Miller (A)* 348 8-303-663-3595 S. Poet (A) 279 78-652-2297 l M. Prochownik (A) 280 9-785-6010 S. Rima (A) 279 78-772-4068
- 7s
%. _,l FORM (C)372 22 M
RERP Phone Lists Issue 26 0Public FORT ST. VRAIN NUCLEAR GENERATING STATION page 16 of 70 service
- PUBUC SERVICE COMPANY OF COLORADO
.,,3 LJ STATE EOC CALL LIST INSTRUCTIONS (For Contacts by PSC) In the event you are notified by the PSC operator that a Radiological ALERT or higher classification event has occurred at Fort St.
- Vrain, complete the following telephone calls:
1. If you are the PSC primary contact: a. Call the PSC alternate contact and instruct him to complete the call list. b. If you cannot reach the PSC alternate contact, call the first person on the attached list and inform him to complete the call list. 2. If you are the PSC alternate contact and are notified by the PSC primary contact: a. ' Complete the attached call list. ,m 3. If you are the PSC alternate contact and are notified by () the PSC operator: a. Call the first person on the attached list ag inform him to complete the call list. .,a ./ FORM (C)372 22 3643
RERP Phone Lists Issue 26 ,.gs. 0 Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 17 of 70 PUBUC SERVICE COMPANY OF COLORADO V
STATE EOC CALL LIST (For Contacts by PSC) Extension Home Time Technical Assistance H. L. Brey (Primary) 571-8404 469-4238 M. H. Holmes (Alt.) 571-8409 988-4522 Radiological Consultant I,F.. Ward Whicker 491-5343 221-3870 Media Relations R. A. Burns (Primary) 571-7726 759-9740 G. Reeves (Alt.) 571-7726 424-4958 _g U Note: Any change to this call list requires a change be made to RERP-HOME, Attachment #8. l l l ' O l FORMICl372 22 3643 a ,.,. ~ - -.,,,. -,, -.,, ,w..- -n._,.-
RERP Phone Lists Issue 26 3 0 ServlCe* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 18 of 70 PUBLIC SERVICE COMPANY OF COLORADO ' (~). v TSC DIRECTOR'S CALL LIST INSTRUCTIONS In the event that you are notified by the PSC operator that a Radiological ALERT or higher classification event has occurred at Fort St. Vrain, complete the following telephone calls: 1. If you are-the response center / post Director: a. Call your response center / post Alternate Director (the alternate will complete the calls on the attached list). b. If you cannot contact your Alternate Director, call the first person on the attached list and inform him to complete the call list. 2. If you are the response center / post Alternate Director and are contacted by the Director: a. Complete the attached call list. '3, If you are the response center / post Alternate Director and .(): are contacted by the PSC Operator: 7 a. Call the first person on the attached list and inform him to complete the call list. s_- 5 e FORMtC1372 22 3643
i RERP Phone Lists Issue 26 O SerVlCO* Page 19 of 70 Public FORT ST. VRAIN NUCLEAR GENERATING STATION PU3LIC SERVICE COMPANY OF COLORADO 3 kj TSC DIRECTOR'S CALL LIST First call all primaries, then call all alternates. Engineering and Plant Technical Analysis Extension Home Time Primary - J. Eggebroten 270 651-1253 (Pager) 890-2220 Alternate - R. Heller 284 772-1093 Radiolocical Assessment Primary - J. Sills 265 221-5059 (Pager) 890-2223 l -Alternate - S. Johnson 285 587-4278 Technical Support Contact three persons listed below in order of preference: A. Reed
- 325 772-5312 (Pager) 890-1942
.,-w M. Joseph
- 275 465-1248 3
(Pager) 890-2835 ,/ l .0. Clayton 277 663-3939 s D. Stuart 274 651-1927 R. Gappa 283 484-2306 l J. Wojtisek 268 364-2855 Plant Condition Assessment Call two off-duty Shift Supervisors M. Denisten 219 776-3776 D. Evans 219 776-9672 J. Hak 219 776-1904 D. Hood ** 219 or 347 776-1843 J. Hunter 219 330-1411 -H. O'Hagan 219 'i16-8232 G. Reigel 219 330-4235 l J. Vandyke 444 772-2476 Reed or Joseph may not be available if either is the on-duty Technical Advisor. Also contacted as alternate to Control Room Director by PSC operator. 7s. Cl FORMtCa372-22 3643
RERP Phone Lists Issue 26 0SerVlCO* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 20 of 70 PUBLIC SERVICE COMPANY OF COLORADO ,_.s () Emeroency Maintenance Primary - W. Craine 222 667-5427 Alternate - J. Petera 233 427-6273 Instrument anc Control Primary - B. Burchfield 249 351-0373 . Alternate - J. McCauley 248 667-0635 Senior Health Physics Representative Primary - T. Schleiger 242 785-6314 Alternate - B. Woodcrd 244 678-0818 Administration / Logistics Primary - A. Kitzman 206 737-2578 Primary - P. Collins 207 587-2172 Primary - P. Bollig 204 339-3972 Alternate - D. Connelly 210 353-4575 Telechone Console Operators ,,k) Primary - D. Edwards 214 669-1680 l Alternate - D. Libal 208 651-1404 Computer Support
- Primary - D. Klaus 437 466-5046
- Alternate - D. Haloin 376 353-1993
- Computer Services Page Number: 855-3234 Note: Any changes made to this call list requires a change be made to RERP-HOME, Attachment #9.
FORM (C)372 22 3643
RERP Phone Lists Issue 26 0 Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 21 of 70 PUBUC SERVICE COMPANY OF COLORADO
.,~d CENTERS / POSTS PHONE NUMBERS
- Phone Control Room (CR)
Lists Affected Denver Line 571-7436 P Greeley Line 785-2223 P Longmont Line 776-6710 P Site Extension-220 P Site Extension 221 P Executive Command Post (ECP) Headquarters Building - Room 620 Denver Line 571-8459 P Denver Line 571-8460 P Denver Line 571-8461** P Lookout Center - Golden Denver - Line 278-2222 P Denver Line 278-0287 P (G _/ Emeroency Operations Center - State (SEOC) Camp George West Denver Line 279-2511 P Denver Line 279-8855 D,P,U,W Forward Command Post (FCP) Fort Lupton Denver Line 571-7053 571-7070 571-7096 571-7061 P 571-7062 Ft. Lupton Line 857-6238 857-6246 857-6239 857-6022 P 857-6247 857-6248 857-6249 857-6001 857-6230 For any call into FSV from another PSC dimension phone, dial 8-785-1xxx, where xxx is the three digit FSV extension. This line reserved for conferencing between the FCP AND ECP. Il W./ FORM (Cl372 22 3643 -, - ~
RERP Phone Lists Issue 26 O service
- Public FORT ST.. VRAIN NUCLEAR GENERATING STATION Page 22 of 70 PUBLIC SERVICE COMPANY OF COLORADO Governor Off1ce 866-2471 F,P,W Mansion 837-8350 F,P,0,W O
O FonMtC1372 22 3M3
RERP Phone Lists Issue 26 0 SerVlCe* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 23 of 70 PUBUC SERVICE COMPANY OF COLORADO (_) CENTERS / POSTS PHONE NUMBERS Phone Personnel Control Centers Lists Affected Onsite Training Center Site Extension 450 0 Engineering /QA Complex Site Extension 362 P Offsite Johnstown County Shop Greeley Line 587-4508 P County Engineer, Drew Scheltinga 356-4000 P Ext. 4750 <-3 Maintenance Supervisor, Bud Schmuhl 587-2431 P '\\._,) (Home) Production Manager, Dave Becker 356-0177 P (Home) Maintenance Support Supervisor, 284-5451 P Jack Slife (Home) longmont PSC Service Center Denver Line (Louisville) 665-5511 P Longmont Line 776-0933 P Platteville Fire Department l Greeley Line 785-2232 P,Q Contact Cliff Wright, Greeley Line 785-2835 P,Q Weld County, Maintenance 356-4000 ext. 777 P Q,j FORMIC 1372 22 3843
RERP Phone Lists Issue 26 OSerVICe* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 24 of 70 PUBLIC SERVICE COMPANY OF COLORADO G CENTERS / POST; PHONE NUMBERS Phone Technical Support Cen:.er' Lists Affected Site Extension 290 P Site Extension 291 E,P Site Extension 292 P Site Extension 293 0,E,H,P Site-Extension 294 E,P Site Extension 295 P Visitor Center Site Extension 475 A,P Lunchroom Site Extension 2f? A,P -O rJ FORMICl372 22 3843 m
, = -. RERP Phone Lists Issue 26 0 service
- Public FORT ST VRAIN NUCLEAR GENERATING STATION page 25 of 70 PUBUC SERVICE COMPANY OF COLORADO
,_s ^L) OUTSIDE ASSISTANCE PHONE NUMBERS Phone Ambulance Services Lists Affected Platteville Fire Department (Platteville) 785-2232 Q (Greeley Line) 911 Q Professional Ambulance Service (Longmont) 776-1211 Q . Weld County Ambulance Service (Greeley) 353-5700 Q St. Lukes Helicopter (ask for Admitting) 869-2012 Q 869-2013 Q or 869-2014 Emergency: 869-2111 Q Fire Departments Fort Lupton 857-6619 P,Q Johnstown 587-4477 Q Platteville 705-2232 P,Q Medical Facilities ) St. Luke's Hospital (Denver) 839-1000 Q,S 869-2111 0,S 869-2112 Q,S North Colorado Medical Center-(Greeley) 352-4121 0,S Memorial Hospital (Greeley) 352-3123 Q,5 .Longmont United Hospital (Longmont) 651-5111 Q,5 Emergency: 651-5000 Q,5 National Weather Service l-Ask for LEAD Forecaster 844-4207 Q l l or 844-3611 Q Institute of Nuclear Power Operations (INPO) (404) 953-0904 Q,J i (404) 953-0922 0,J l Rapicon: (404) 953-9208 Q l Telecopy Verification: (404) 952-6728 Q NRC Operations Center (202) 951-0550 E,F,G, 0,0,W,x (301) 427-4056 E,0 (301) 427-4259 E,Q (301) 492-8893 E,Q (301) 492-7000 E,0 ,V. FORMIC 1372 22 3643 o.
RERP Phone Lists Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 26 of 70 PUBUC SERVICE COMPANY OF COLORADO V
DUTSIDE ASSISTANCE PHONE NUMBERS Phone Lists Affected Backup Meteorological Tower Data (NOAA) Bob Clark 497-6987 Q Dick Garrelts 497-6972 Q Aucrene Brown 497-6159 Q Silent 700-300 Baud Modem
- 447-0992 0
Laboratory 497-6792 Q Adciinistrative Office 497-6116 Q To have line cleared when busy, call Mr. Val Swarcz (SERI) at 231-1816. County 5,eriff 356-4000 Q City Police a Johnstown 587-4664 Q Platteville 785-2215 Q (O/ State Fatrol 353-1151 Q or 9-911 Q Coast Guard 1-800-424-8802 Q,T Colorado State Health Department 320-8333 J,Q,T L Environmental Protection Agency 234-2259 Q,T or 234-6069 Q,T American Nuclear Insurers (ANI) 1-800-243-3172 C,J,Q,U (203) 677-7305, ext. 245 C,J,Q,U (203) 677-7315 C,J,Q (203) 677-6989 C,Q (203) 677-7715 C,Q American Nuclear Society (312) 352-6611 J,Q 1-800-323-3044 J,Q 24 hour emergency only: (312) 352-6814 J,Q fl a t FORM (C)372 22 3643 b
RERP Phone Lists Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING bTATION Page 27 of 70 PUBLIC SERVICE COMPANY OF COLORADO
.. O x/ VISITOR CENTER PHONE NUMBERS Phone Lists Affected Site Extension 475 R 476 785-1475 R Persons Living Within Property Boundary
- 1.
Ben Houston 785-2408 R,I 2. Randy Russell 785-6326 R,I 3. Bill Pitt 785-6274 R,I 4. Raymond Marin 785-2862 R,I 5. Vacant No Phone 6. Scott Houston 785-2358 R,I 7. Keith Russell 785-2589 R,I 8. Dave LaChance 785-6303 R,I rm V When these telephone numbers are verified, updates must be' reflected in the PCC Procedure, Attachment 2. O FORMICl372 22 3643
h RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION - Page 28 of 70 PUBUC SERVICE COMPANY OF COLORADO s,3V ADMINISTRATIVE Phone Lists Affected l AMICK, D.B.
K,L l Longmont l 772-9378 (Home) l-571-7898 (Work) l. Assigned To: ECP BORST, F.J. C,E,L, S,U,V,Z Loveland 663-1230 (Home) 203 (Work) 890-1775 (Page Number) Assigned To: FCP p. l BOUTON, JAMES C. S V l Englewood l 796-9712 (Home) l 571-3501 (Work) l Assigned To: NONE BREY, H.L. J,Y Broomfield 469-4236 (Home) 571-8404 (Work) Assigned To: SEOC BUMPUS, J.N. K Denver 388-7645 (Home) 571-7821 (Work) Assigned To: ECP BURNS, R.A. N,S,Z Denver 759-9740 (Home) 571-7726 (Work) Assigned To: SEOC O FoMMIC)372 22 3643
RERP PHONE LISTS Issue 26 0 Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 29 of 70 PUBLIC SERVICE COMPANY OF COLORADO (3
V ADMINISTRATIVE Phone Lists Affected l BUZICK, GEORGE S l Lakewood l 985-0655 (Home) l 571-2912 (Work) l Ass *gned To: NONE l CARROLL, JOHN S l Wheatridge l 422-3600 (Home) l 571-3200 (Work) l Assigned To: NONE l CROLEY, BILL S l Westminister l 469-1676 (Home) nU l 571-7771 (Work) l Assigned To: NONE l DONOVAN, RONALD E. S l Denver l 399-8696 (Home) l 571-7042 (llork) l Assigned To: NONE FITZMAURICE, W. K,5 Denver 424-8053 (Home) 571-7713 (Work) Assigned To: ECP FULLER, C. H. C,E,J, S,T,U, V,Y,Z Loveland 663-2363 (Home) 202 (Work) 890-0810 (Page Number) Assigned To: TSC g%J' FORMIC 1372 22 3643
RERP PHONE LISTS Issue 26 0*SerVlCe* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 30 of 70 PUBUC SERVICE COMPANY OF COLORADO V ADMINISTRATIVE Phone Lists Affected FULLER, J.K. J,Y Denver 779-1109 (Home) 329-1104 (Work) Assigned To: FCP GAHM, J. W. C,E,J, S,T,U, V,Y,Z Northglenn 452-0507 (Home) 200 (Work) 890-6359 (Page Number) Assigned To: TSC O sock. o.o. x Denver-394-3063 (Home) 571-7211 (Work) Assigned To: ECP HOLMES, M.H. N Lakewood 988-4522 (Home) 571-8409 (Work) Assigned to: SE0C LANE, E. K,S Denver 321-4016 (Home) 571-8533 (Work) Assigned To: ECP LEE, 0.R. C,E,J, S,T,V, Y,Z Brighton 659-1180 (Home) 571-7105 (Work) l 890-2834 (Page Number) Assigned To: FCP O t ks' =. FORM (C)372-22 3643
RERP PHONE LISTS Issue 26 0 Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 31 of 70 PUBLIC SERVICE COMPANY OF COLORADO e
U ADMINISTRATIVE Phone Lists Affected l McCARTER, PATRICK W. S l Broomfield l 466-3460 (Home) l 797-4178 (Work) l Assigned To: NONE McNELLIS, D. J,Y Denver 321-3142 (Home) 571-7254 (Work) Assigned To: SEOC MORA, MARILY L,S,Z Denver Ce. 694-2369 (Homt.) 571-8462 (Work) Assigned To: FCP NIEHOFF, M. E. K Aurora 690-3879 (Home) 403 (Work) Assigned to: ECP NOVACHEK, F. C, E,J, L,S,U, V,Y,Z Thornton 457-8034 (Home) 201 (Work) 890-1941 (Page Number) Assigned To: FCP 0'DONNELL, B. J,Y Denver 388-0211 (Home) 571-7381 (Work) Assigned To: ECP (G _) FORMICI372 22 3b43 ..n,----,---
RERP PHONE LISTS Issue 26 FORT ST. VRAIN NUCLEAR GENERATING STATION Page 32 of 70 0Public SerVICO* PUBLIC SERVICE COMPANY OF COLORADO = ADMINISTRATIVE Phone Lists Affected O'NEAL, E. E. K,S Denver 757-0038 (Home) 571-7709 (Work) Assigned To: ECP l PARK 0, JERRY F. S l Westminster l 466-6367 (Home) l 797-4111 (Work) l Assigned To: NONE PERSON, R.T., JR. K Englewood 753-9292 (Home) O 571-7323 (Work) U Assigned To: ECP REESY, JACK R. K Denver 755-1720 (Home) 571-8406 (Work) Assigned T:,: ECP REEVES, G.D. N,S,Z Arvada 424-4958 (Home) 571-7726 (Work) Assigned To: SEOC SINGLETON, L.W. J,L,Y Longmont 772-1018 (Home) 350 (Work) Assigned To: FCP l SNAPP, DONALD R. S -l Denver l 756-9180 (Home) ? l 571-7445 (Work) l Assigned To: NONE /D V FORMICl372 22 3643 l
RERP PHONE LISTS Issue 26 0 Servlee'" Public FORT ST. VRAIN NUCLEAR GENE 9ATING STATION Page 33 of 70 PUBLIC SERVICE COMPANY OF COLORADO n L.) ADMINISTRATIVE Phone Lists Affected VOLSTAD, STEPHEN A. L Denver 750-1785 (Home) 571-7242 (Work) Assigned To: FCP WALKER, R.F. J,Y Denver 234-9298 (Home) 571-7333 (Work) Assigned.To: ECP WAREMBOURG, D.W. J,L,Y Frederick 833-4092 (Home) ,r'g 571-8419 (Work) V Assigned To: FCP l i. l l v FORMfCl372 22 3643
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 34 of 70 ) SerVICO PUBLIC SERVICE COMPANY OF COLORADO ~- CHEMISTRY Phone Lists Affected ADAMSKI, HANK Boulder 444-3533 (Home) 226 (Work)' Assigned To: NONE l ALBERT, DEBBIE l Frederick l 833-2372 (Home) l 226 (Work) l Assigned To: NONE BRUNGARDT,. JESSE Fort Collins 493-9272 (Home) A 226 (Work) U Assigned To: NONE FETTER 0LF, DAVE L. Greeley l 356-8483 (Home) 226 (Work) Assigned To: NONE LUCERO, VICTOR A. l Fort Collins l 223-3163 (Home) 225 (Work) 855-5504 (Page Number) Assigned To: NONE FORM fC)372 22 3843
q RERP PHONE LISTS Issue 26 O Service" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 35 of 70 PUBLIC SERVICE COMPANY OF COLORADO = r-'S i L.! COMPUTER SERVICES Phone Lists Affected BILSTEIN, DON Berthoud 532-2546 (Home) 333 (Work) Assigned To: NONE HALOIN, DON Greeley 0 353-1993 (Home) 376 (Work) Assigned To: TSC KLAUS, DON L. O Broomfield 466-5046 (Home) (t/~3 437 (Work) Assigned To: TSC METCALFE, DOUG Westminster 425-1695 (Home) 344 (Work) Assigned To: NONE ' i U FMM1C1372 22 3643
RERP PHONE LISTS Issue 26 0Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 36 of 70 service
- PUBLIC SERVICE COMPANY OF COLORADO i
(3 V ELECTRIC Phone Lists Affected BRUXV00RT, MARVIN J. Loveland 669-7175 (Home) 233 (Work) Assigned To: NONE CRUZ, DAN Westminster .428-0157 (Home) 233 (Work) Assigned To: NONE HARTSOUGH, PATRICK J. Fort Lupton 785-2463 (Home) (3 233 (Work) 't ' Assigned to: NONE JARRETT, MICHAEL S. Thornton 451-7145 (Home) 233 (Work) Assigned to: NONE LAMB, ROBERT E. M Longmont 772-0757 (Home) 336 (Work) Assigned To: PCC PETERA, JAMES 0,U Westrir. ster 427-6273 (Home) 233 (Work) 890-0832 (Page Number) A signed To: TSC FORM tC)372 22 3643
V RERP PHONE LISTS Issue 26 0 SGIVlC9 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 37 of 70 PUBUC SERVICE COMPANY OF COLORA"i0 O ELECTRIC Phone Lists Affected QUINTANA, MARK R. Northglenn 452-4818 -(Home) .233 (Work) Assigned To: NONE i 4
- O i
O > FORM (Cl372 22 3843
RERP PHONE LISTS Issue 26 0 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 38 of 70 Service" PUBUC SERVICE COMPANY OF COLORADO (v MAINTENANCE Phone Lists Affected ADAMS, DENNIS R. Longmont 772-7759 (Home) 232 (Work) Assigned To: NONE AMEN, TOM Greeley 330-9868 (Home)
- 232 (Work)
Assigned To: NONE l BANNICK, DARYL l Denver l 288-3451 (Home) (m l. 232 (Work) el l Assigned To: NONE BASS, ROY J., JR. Northgicnn 452-2716 (Home) 232 (Work) Assigned To: NONE BATES, G. DEXTER Greeley 356-1894 (Home) l 255 (Work) Assigned To: NONE BISHARD, LEVI V. Brighton 452-7245 (Home) 343 (Work) 855-7257 (Page Number) Assigned To: NONE .BURNETT, RANDALL Brighton 659-0787 (Home) 228 (Work) Assigned To: NONE ( FORM (C)372 22 3643 , _ _. _. _.. ~.....
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 39 of 70 service
- PUBLIC SERVICE COMPANY OF COLORADO
%] MAINTENANCE Phone Lists Affected l BURROW, MARK l Northglenn l 457-8452 (Home) l 232 (Work) l Assigned To: NONE CAMP, MICHAEL Fort Lupton 857-4770 (Home) 228 (Work) Assigned To: NONE CLARK, ARTHUR L. Berthoud 532-4081 (Home) O 228 (Work) ~ Assigned To: NONE l CLAYTON, DWIGHT Johnstown 587-4700 (Home) 232 (Work) l. Assigned To: NONE COGDILL, LARRY Johnstown 587-4825 (Home) 232 (Work) Assigned To: NONE CRAINE, WARD A. 0,U Loveland 667-5427 (Home) 222 (Work) 890-0804 (Page Number) Assigned To: TSC DAVIS, JENNIFER Evans l l 330-6304 (Home) .231 (Work) ] Assigned To: NONE FORM (C)372-22 3643
RERP PHONE LISTS Issue 26 0 SerVICO* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 40 of 70 PUBLIC SERVICE COMPANY OF COLORADO .() MAINTENANCE Phone Lists Affected DESANTI, ROCKY Brighton 659-3942 (Home) 232 (Work) Assigned to: NONE l DILLER, EDWARD l Fort Lupton l 785-6319 (Home) l 232 (Work) l Assigned To: NONE DIXON, GEORGE D. Longmont 776-2634 (Home) O 228 (Work) 855-7257 (Page Number) Assigned To: NONE l GARCIA, JOHN l Denver l 650-9834 (Home) l 232 (Work) i l l Assigned To: NONE GUILLEN, ANTHONY l Longmont l 772-3191 (Home) l 232 (Work) l-Assigned To: NONE HALVORSON, JOHN Johnstown 587-2226 (Home) 232 (Work) Assigned To: NONE HOOD, GREG Longmont 776-9804 (Home) 232 (Work) - (] Assigned To: NONE FORMIC)372 22 3643
RERP PHONE LISTS Issue 26 0 Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 41 of 70 PUBLIC SERVICE COMPANY OF COLORADO
%) MAINTENANCE Phone Lists Affected JUDSON, RICK Johnstown 587-4120 (Home) 232 (Work) Assigned To: NONE KARICH, JACK Plattwille 785-2959 (Home) 232 (Work) Assigned To: NONE KRUSE, QUENTIN L. Brighton 451-1901' (Home) be 232 (Work) Assigned To: NONE LEWIS, ORVAL A. Commerce City 288-4370 (Home) 232 (Work) Assigned To: NONE LLANAS, FRANK Fort Lupton 857-2583 (Home) 232 (Work) Assigned To: NONE MANENTI, THOMAS Greeley 330-0978 (Home) 228 (Work) Assigned To: NONE MEDBERY, GERALD D. s Greeley 330-6119 (Home) 232 (Work) Assigned To: NONE FORM (C)372 22 3643
RERP PHONE LISTS Issue 26 0$9TVIC9" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 42 of 70 PUBUC SERVICE COMPANY OF COLORADO $gd MAINTENANCE Phone Lists Affected MEIER, EDWARD J. Denver 355-2988 (Home) 230 (Work) Assigned To: NONE MONTOYA, JOHN P. Platteville 785-2961 (Home) 228 (Work) Assigned To: NONE MORGAN, GREGORY R. Greeley 353-2693 (Home) gv< 389 (Work) Assigned To: NONE OWEN, JON E. Johnstown ~ 587-2385 (Home) 340 (Work) 855-7257 (Page Number) Assigned To: NONE RHOTON, MICHAEL A. l Johnstown l 587-4083 (Home) 232 (Work) Assigned To: NONE l ROBERTS, MIKE J. l Thornton l 457-9145 (Home) l 232 (Work) l Assigned to: NONE ROWELL, ROBERT L. Platteville 785-6268 (Home) O 232 (Work) V Assigned to: NONE FORMICI372 22 3643
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 43 of 70 0ServicG* PUBUC SERVICE COMPANY OF COLORADO %s MAINTENANCE Phone Lists Affected -SCHUYLER, TIMOTHY LEE Brighton 659-1183 (Home) 235 or 232 (Work) . Assigned To: NONE SKAGGS, EDWARD ROY Greeley ,(Home) 352-6334 i 232 (Work) Assigned To: NONE SKELLY, GREGORY J. Arvada 426-5661 (Home) O 232 < Work) Assigned To: NONE SLABY, RICKY H. Denver 287-0675 (Home) 232 (Work) Assigned To: NONE SMOOT, GREGORY ALAN Longmont 776-0338 (Home) 232 (Work) Assigned To: NONE SNYDER, JERRY Greeley 352-3032 (Home) 232 (Work) Assigned To: NONE STEPHENS, DEAN . Denver 296-4073 (Home) 232 (Work) Assigned To: NONE FohM (C) 372-22 + 3643
RERP PHONE LISTS ' Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 44 of 70 0 service
- PUBLIC SERVICE COMPANY OF COLORADO a p) b MAINTENANCE Phone Lists Affected TREGONING, WILLIAM E.
Johnstown 587-2133 (Home) 232 (Work) Assigned To: NONE l WALKER, STEVE l Lakewood l 237-5726 (Home) l 232 (Work) l Assigned To: NONE WEBB, RONALD W. U,M Longmont q 776-8219 (Home) V 229 (Work) 855-7257 (Page Number) Assigned To: PCC WEILNAU, LARRY L. Platteville 785-6050 (Home) 232 (Work) Assigned To: NONE WERNESS, STEPHEN J. Berthoud 532-2577 (Home) 232 (Work) Assigned To: NONE WINDHORST, WILLIAM Platteville 785-6420 (Home) 232 (Work) Assigned To: NONE YODER, FRED Johnstown 587-4107 (Home) p 232 (Work) U Assigned To: NONE FORMICl372 22 3643
RERP PHONE LISTS Issue 26 0 SerVICG" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 45 of 70 PUBUC SERVICE COMPANY OF COLORADO . b MISCELLANEOUS Phone Lists Affected JOHNSON, JAMES E. J Ft. Collins 482-3029 (Home) 491-5380 (Work) Assigned To: NONE l JOHNSON, JANET Ft. Collins 482-3029 (Home) 491-5930 (Work) l Assigned To: NONE MCDONALD, MARION J Ft. Collins 484-0084 (Home) Il 491-5094 (Work) V Assigned To: NONE OLSON, HILDING G. Fort Collins 493-8797 (Home) 491-6558 (Work) 491-5450 (Work) Assigned To: NONE PLUMLEE, G.L., III E,J,Z Longmont 776-9541 (Home) 490 (Work) l 785-2282 (Work) 890-2225 (Page Number) Assigned To: NONE l WHICKER, F. WARD N l Fort Collins l 221-3870 (Home) l 491-5343 (Work) l Assigned To: SE0C ( FoRMtCl372 22 3643
RERP PHONE LISTS Issue 26 O service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 46 of 70 PUBLIC SERVICE COMPANY OF COLORADO
= Y NUCLEAR DOCUMENTS Phone Lists Affected BELGARD, DIANNE M Longmont 678-0355 (Home) l 445 (Work) Assigned To: PCC BOLLIG, PATRICIA L. O Evans 339-3972 (Home) 204 (Work) Assigned To: TSC l BREWER, MARGOT l .Johnstown l 587-2474 (Home) ('; l 216 (Work) \\s l Assigned To: NONE CONNELLY, DANA 0 Evans 353-4575 (Home) 210 (Work) Assigned To: TSC COLLINS, MARGARET 0. O Johnstown 587-2172 (Home) 207 (Work) Assigned to: TSC EDWARDS, DONNA 0 Loveland 669-1680 (Home) 214 (Work) Assigned To: TSC FLORES, ABBY l Evans l 339-5018 (Home) l 205 (Work) Assigned To: NONE O NJ FORM (C)372 22 3643
RERP PHONE LISTS Issue 26 0 SOTVlCG Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 47 of 70 PUBLIC SERVICE COMPANY OF COLORADO G G7 NUCLEAR DOCUMENTS Phone Lists Affected FOSTER, BARB Longmont 772-5552 (Home) 209 (Work) Assigned To: NONE KATCHER, SUE M. L Greeley ..s 356-0351 (Home) 212 (Work) Assigned To: FCP KITZMAN, AUDREY L. O Platteville 737-2578 (Home) O zos (wor') Assigned To: TSC LEHR, SUSAN M Westminster 422-1280 (Home) 451 (Work) Assigned To: PCC LIBAL, DEBBIE O Longmont 651-1404 (Home) l 208 (Work) Assigned To: TSC SHAFER, TERRI M Loveland 663-4862 (Home) 457 (Work) Assigned To: PCC STROH, CARLENE Johnstown 587-2150 (Home) 238 (Work) Assigned To: SAS FORM (C)372 22 3643
t RERP PHONE LISTS Issue 26 O SerVICO'" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 48 of 70 PUBUC SERVICE COMPANY OF COLORADO O NUCLEAR DOCUMENTS Phone Lists Affected i. TAYLOR, MICHELLE Fort Collins 484-6705 (Home) 337 (Work) Assigned To: CAS J t 4 i O FORM (Cl372 22 + 3643
RERP PHONE LISTS Issue 26 0 SerVICG* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 49 of 70 PUBUC SERVICE COMPANY OF COLORADO f% G OPERATIONS Phone Lists Affected ASHMORE, WILLARD J. Platteville-785-6344 (Home) 221 (Work) Assigned To: NONE DAHLSTROM, JOHN Grealey 353-6536 (Hone) 221 (Work) Assigned To: NONE DECATOIRE, DAVID A. Johnstown .O-587-4038 (Home) 222 (work) Assigned To: NONE DENISTON, MARTIN E. 0,0 Longmont 776-3776 (Home) 219 (Work) Assigned To: TSC DICE, THOMAS J. Loveland 669-e950 (Home) 327 (Work) Assigned To: NONE EINIG, KENNETH J. Longmont 651-1279 (Home) 221 (Work) Assigned To: NONE EVANS, CHRISTOPHER J. Milliken 587-2418 (Home) 221 (Work) Assigned To: NONE l FonM(C)372 22-3643 I_
RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 50 of 70 PUBUC SERVICE COMPANY OF COLORADO
[l v OPERATIONS Phone Lists Affected EVANS, DENNIS W. 0,U Longmont 776-9672 (Home) 219 (Work) Assigned To: TSC FIELDS, M.D. Greeley 352-6976 (Home) 221 (Work) Assigned To: NONE FISHER, JEFFREY Greeley O_ 330-6130 (Home) 221 (Work) -Assigned To: NONE FOSTER, KENT E. Longmont 772-5552 (Home) 221 (Work) Assigned To: NONE FRANEK, WILLIAM J. C,E,J, Berthoud T,U,V, 532-3489 (Home) Y,Z 218 (Work) 890-0558 (Page Number) Assigned To: CR FRAZIER, MICHAEL S. Northglenn 457-3719 (Home) 221 (Work) Assigned To: NCNE FROST, BRIAN C., Greeley 351-7430 (Home) 221 (Work) Assigned To: NONE - FORMICl372 22 3643 ~.......
RERP PHONE LISTS Issue 26 0 Service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 51 of 70 PUBUC SERVICE COMPANY OF COLORADO 0,
v OPERATIONS Phone Lists Affected HACKETT, LANE L., JR. Greeley 330-1063 (Home) 221 (Work) Assigned To: NONE HAK, JOHN P. 0,U Longmont 776-1904 (Home) 219 (Work) Assigned To: TSC HANLON, JOSEPH E. Windsor 686-9169 (Home) 'Q-221 (Work) Assigned To: NONE HANSEN, ERIC Greeley 356-3539 (Home) 220-(Work) Assigned To: NONE l HASERMAN, MARK F. l Greeley l 353-0254 (Home) i 221 (Work) I l Assigned To: NONE l HOLMES, DAVID B. l Greeley 330-0757 (Home) 327 (Work) Assigned To: NONE HOOD, DONALD P. E,J, Longmont 0,Y 776-1843 (Home) 219 or 347 (Work) Assigned To: TSC O FORMtCl372 22 3643
RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 52 of 70 PUBUC SERVICE COMPANY OF COLORADO
= ,a (_) OPERATIONS Phone Lists Affected HOOVER, JAMES A. Loveland 663-1835 (Home) 221 (Work) Assigned To: NONE HUNTER, JOE J. 0,U Greeley 330-1411 (Home) 219 (Work) Assigned To: TSC JOHNSON, DARRELL E. Platteville 785-6089 (Home) 'O 221 (Work) Assigned To: NONE KASTEN, MICHAEL D. Platteville 785-2377 (Home) 221 (Work) Assigned To: NONE KEVA>l, ROBERT L. Longmont 772-3922 (Home) 221 (Work) Assigned To: NONE KOLESKI, STANLEY V. Northglenn 457-3572 (Home) 221 (Work) Assigned To: NONE LAWLOR, BRUCE Evans 330-3312 (llome) 221 (Work) Assigned To: NONE FORM 1C)372 22+3643
f RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 53 of 70 PUBLIC SERVICE COMPANY OF COLORADO U
OPERATIONS Phone Lists Affected LOPKOFF, WILLIAM W. Greeley 330-0230 (Home) 221 (Work) Assigned To: NONE MAGNINIE, WAYNE H. Frederick 833-4224 (Home) 221 (Work) Assigned To: NONE MAYNARD, JOHN H. Longmont 772-3634 (Home) f') 221 (Work) Assigned To: NONE MOORE, GAROLD E. Greeley 355-5378 (Home) 220 (Work) Assigned To: NONE MORGAN, PHILIP C. Greeley l 330-5269 (Home) l 221 (Work) Assigned To: NONE MURPHY, SHAWN Evans 330-0431 (Home) 221 (Work) Assigned To: NONE NETZEL, KEN Longmont 772-4618 (Home) 2?O (Work) l Assigned To: NONE l n m FORMtC1372 22 3643 L
r: RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 54 of 70 PusuC SERVICE COMPANY OF COLORADO
'w. i OPERATIONS Phone Lists Affected O'HAGAN, HUGH J. 0,U Longmont 776-8232 (Home) 219 (Work) Assigned To: TSC REIGEL, GLEN V. 0,U Greeley 330-4235 (Home) 219 (Work) Assigned To: TSC SHAFER, STEVEN Platteville C,- 785-6042 (Home) 220 (Work) Assigned To: NONE l SHERON, EMIL S. l Broomfield l 469-0948 (Home) l 221 (Work) l Assigned To: NONE TRUMBLEE, DENNIS Platteville 785-2593 (Home) 221 (Work) Assigned To: NONE VANDENB00GAARD, W. J. Longmont 651-3732 (Home) 221 (Work) Assigned To: NONE VAN DYKE, JEROME G. 0,0 Longmont 772-2476 (Home) l 444 (Vork) Q Assigned To: TSC or CR Fo4MIC1372 22 3843
r~ RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 55 of 70 PusuC senv CE COMPANY OF COLORADO OPERATIONS Phone Lists Affected VIGIL, ANTHONY L.
Gilcrest 737-2753 (Home) 221 (Work) Assigned To: NONE WEIDERSPON, GARY L. Greeley 356-7038 (Home) 221 (Work) Assigned to: NONE WELLER, JACK R. Johnstown 587-2984 (home) O 222 (wark) Assigned To: NONE i i a ' O i FORMICl372 22.M
RERP PHONE LISTS Issue 26 OService* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 56 of 70 Pusuc senveCE COMPANY OF COLORADO b RADIATION PROTECTION Phone Lists Affected GLAHN, PAUL R. M Northglenn 450-5292 (Home) 245 (Work) Assigned To: PCC HUTCHINS, LESTER C. M Greeley 330-7187 (Home) 245 (Work) Assigned To: PCC MADISON, GORDON S. M Firestone 833-2278 (Home) D 245 (Work) b Assigned to PCC McGAFFIC, VERNON J. M Johnstown 587-2752 (Home) 278 (Work) Assigned To: TSC l MILLER, DONALD D. M Loveland 663-3595 (Home) l 348 (Work) Assigned To: TSC MORSE, KEITH M Greeley 353-6163 (Home) 245 (Work) Assigned To: PCC NASVESCHUK, KENT L. M Longmont 651-6254 (Home) 245 (Work) Assigned To: PCC O FORMtCl372 22 3643 _. _ _. _ _ _.. _., _ _ _ ~. _ _. _ _. _ _.. -. _ _ _. _
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 57 of 70 0ServlCe* PUBUC SERVICE COMPANY OF COLORADO - q -U RADIATION PROTECTION Phone Lists Affected O'DONOGHUE, E. JOHN M Northglenn 452-3514 (Home) 245 (Work) Assigned To: PCC POET, STEWART M Longmont 652-2297 (Home) 279 (Work) Assigned To: TSC PROCHOWNIK, MICHAEL R. M Platteville 785-6010 (Home) C'-' l 280 (Work) Assigned To: TSC RIMA, STEVEN D. M Longmont 772-4068 (Home) 279 (Work) Assigned To: TSC SCHLEIGER, TIMOTHY E. 0,5 Platteville 785-6314 (Home) 242 (Work) Assigned To: TSC SHERROW, STEVEN S. M Greeley 353-1338 (Home) 245 (Work) Assigned To: PCC SIEG, STEVEN E. M Loveland 663-3468 (Home) 245 (Work) Assigned To: PCC d FORMtCl372 22 3643
7.- RERP PHONE LISTS-Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 58 of 70 0 service
- PusuC SERVICE COMPANY OF COLORADO RADIATION PROTECTION Phone Lists Affected VALENTINE, GRANT D.
M Fort Collins 223-7676 (Home) 245 (Work) Assigned To: PCC WOODARD, WILLIAM E. O Longmont 678-0818 (Home) 244 (Work) Assigned To: TSC O i l i O I I FORMtCl372 22 3643 1
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 59 of 70 O Service
- PUBUC SERVICE COMPANY OF COLORADO r%
!v/ RESULTS t Phone Lists Affected ANDERSON, BARNEY J. Greeley 351-0722 (Home) 286 (Work) Assigned To: NONE BALL, JOSEPH W. Denver 477-6013 (Home) 286 (Work) Assigned To: NONE BARTA, BRADLEY G. Denver 426-1832 (Home) O 256 (Work) V Assigned To: NONE BROWN, DANIEL J. Lyons 823-6127 (Home) 286 (Work) Assigned To: NONE BURCHFIELD, ROBERT S. O Greeley 351-0373 (Home) 249 (Work) Assigned To: TSC BURGESS, CHARLES R. Platteville 785-2154 (Home) 286 (Work) Assigned To: NONE COLE, JAMES W. Johnstown 587-2989 (Home) 286 (Work) Assigned To: NONE O FORMIC 1372 22 3643
RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 60 of 70 PUBLIC SERVICE COMPANY OF COLORADO
'\\ (G RESULTS Phone Lists Affected CROWE, CURTIS W. Lafayette l 665-7957 (Home) 247 (Work) Assigned To: NONE DUNHAM, DARYL Keensburg 732-4342 (Home) 288 (Work) Assigned To: NONE l EMBREY, BRAD l Estes Park l 586-4534 (Home) _ (",l l 286 (Work) l Assigned To: NONE l FERRARA, VINCE l Louisville l 666-7747 (Home) l 286 (Work) l Assigned To: NONE GALE, MIKE Gilcrest 737-2521 (Home) 286 (Work) Assigned To: NONE l GARCIA, KEN l Loveland l 663-4878 (Home) l 286 (Work) l Assigned To: NONE JOHNSON, THOMAS Lafayette 665-9507 (Home) 258 (Work) Assigned To: NONE FORM (Cl372 22 3043
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page-61 of 70 Service PUBUC SERVICE COMPANY OF COLORADO L.) RESULTS Phone Lists Affected JOHNSON, TINA Denver 452-5436 (Home) 257 (Work) Assigned To: NONE McCAULEY, JERRY 0 Loveland 667-0635 (Home) 248 (Work) Assigned To: TSC l MEADE, Doran l Fort Collins l 484-2306 (Home) m'b) l 281 (Work) l Assigned To: NONE NELSON, 00N M. Johnstown 587-4189 (Home) 246 (Work) Assigned To: NONE 0' CONN 0R, JAMES P. Denver 457-4882 (Home) 259 (Work) Assigned To: NONE ODENBAUGH, KATHY Platteville 737-2306 (Home) 286 (Work) Assigned To: NONE PETTINGER, ALBERT J. Brighton 536-4333 (Home) 288 (Work) Assigned To: NONE V FORM Cl372 22 3643
RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 62 of 70 service
- PUBLIC SERVICE COMPANY OF COLORADO
= tj RESULTS Phone Lists Affected PINNER, R.S. JOE Greeley 330-9075 (Home) 286 '(Work) Assigned To: NONE -SCHMIDT, A.C. M Louisville 666-6955 (Home) 286 (Work) Assigned To: PCC SHIBATA, BRAD l Thornton l 450-6785 (Home) (q/ 286 (Work) Assigned To: NONE l SMITH, MARK l Northglenn l 457-4470 (Home) l 286 (Work) l Assigned To: NONE TELAROLI, JOHN Loveland 669-0267 (Home) 282 (Work) Assigned To: NONE WEBER, DAVID LEE Johnstown 587-4186 (Home) 286-(Work) Assigned To: NONE O FORM C 372 22 3643
RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 63 of 70 PUBLIC SERVICE COMPANY OF COLORADO G
SCHEDULING / STORES Phone Lists Affected BLOSSOM, MIKE M Platteville 785-6302 (Home) 297 (Work) Assigned To: PCC ERWIN, RICHARD W. M Greeley 330-7178 (Home) 321 (Work) Assigned To: PCC GLASS, GERALD L. J,Y n Brighton () 659-4118 (Home) 253 (Work) Assigned To: PCC HAMBLIN, RICHARD D. M Loveland 667-1703 (Home) 254 (Work) Assigned To: PCC HARDING, CLIFF M Platteville 785-2398 (Home) 311 (Work) Assigned To: PCC HAYS, KAREN M Denver 778-7702 (Home) 319 (Work) Assigned To: PCC HOLCOMB, WALTER E. M Greeley 330-2068 (Home) 312 (Work) O ^=>4 med To: ecc 9 FonMICl372 22 3643
RERP PHONE LISTS Iss'ie 26 0* $9fVlCe* Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 64 of 70 PUBLIC SERVICE COMPANY OF COLORADO SCHEDULING / STORES Phone Lists Affected HORIHAN, DARLENE Longmont M 776-7976 (Home) 250 (Work) Assigned.To: PCC POWERS, G. M l ..Areeley l 356-5256 (Home) 252' (Work) Assigned To: PCC REED, DALE L. M Platteville q-785-2159 (Home) L/ 314 (Work) Assigned To: PCC TEEL, RICHARD M Henderson 288-1959 (Home) 26. (Work) Assigned To: PCC WIDOWS, RICHARD M Loveland 663-1080 (Home) 314 (Work) Assigned To: PCC Ov FoRMtC)372 22 3643 . - -.,,. -. - -. _. ~. - _.. -. - -. -. - - - - -. - - - -,
l RERP PHONE LISTS Issue 26 0 service" Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 65 of 70 PUBLIC SERVICE COMPANY OF COLORADO ,7',) SECURITY Phone Lists Affected ALPS, DONALD R. Longmont 772-9075 (Home) 298 (Work) Assigned To: NONE l BARBERO, BRIAN J. l-Denver l 292-2028 (Home) l 299 (Work) l . Assigned To: NONE BATES, WILLIAM S. Ft. Collins r-484-2966 (Home) i,s) 299 (Work) Assigned To: NONE BENNETT, MICHAEL B. Longmont 776-8311 (Home) 299 (Work) Assigned To: NONE HART, W. DARRIEL Loveland 663-4799 (Home) 299 (Work) Assigned To: NONE HOLLAND, CHARLES C. ' Aurora 344-1327 (Home) 299 (Work) Assigned To: NONE VANH00SER, DENNIS A. Littleton 973-1890 (Home) 299 (Work) Assigned To: NONE FORM tC)372 22 3643 .m.
F RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 66 of 70 0 Service
- PUBUC SERVICE COMPANY OF COLORADO U
TECHNICAL SERVICES Phone Lists Affected BANAGAS, LAURIE Boulder 442-2898 (Home) 273 (Work) Assigned To: NONE BURROWS, RICHARD Fort Collins 493-4258 (Home) l 267 (Work) Assigned To: NONE CLAYTON, OWEN J. O Loveland O" 663-3939 (Home) 277 (Work) Assigned To: TSC DAUM, MICHAEL J. Aurora 690-9652 (Home) 269 (Work) Assigned To: NONE DICKERSON, ROBERT A. Thornton 287-6089 (Home) 273 (Work) Assigned To: NONE l EGGEBROTEN, JAMES 0,U Longmont 651-1523 (Home) 270 (Work) 890-2220 (PageNumber) Assigned To: TSC GAPPA, ROBERT Fort Collins 0 482-2306 (Home) O 283 (Work) V Assigned To: TSC FORMIC 1372 22 3643
RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 67 of 70 Pusuc SERVICE COMPANY OF COLORADO
=hs. TECHNICAL SERVICES Phone Lists Affected HELLER, ROGER A. O Longmont 772-1093 (Home) 284 (Work) Assigned To: TSC HILL, JIM F. Johnstown 587-2553 (Home) 276 (Work) Assigned To: NONE JOHNSON, SHARILYN 0 Johnstown 587-4278 (Home) s) 285 (Work) Assigned To: TSC l JOSEPH, MARK E,0,U Westminster 465-1248 (Home) 275 (Work) l 890-2835 (Page Number) Assigned To: TSC MERRITT, DARLA L Gilcrest 737-2339 (Home) 271 (Work) Assigned To: FCP REED, ASA B. E,0,U Longmont 772-5312 (Home) 325 (Work) 890-1942 (Page Number) Assigned To: TSC REICHARDT, DIANA L Longmont 776-7435 (Home)' (-)s 272 (Work) Assigned To: FCP FORM (C)372 22 3643 e
RERP PHONE LISTS Issue 26 0 service
- Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 68 of 70 PUBLIC SERVICE COMPANY OF COLORADO O
TECHNICAL SERVICES Phone Lists Affected SILLS, JUDD M. E,0,U Fort Collins 221-5059 (Home) 265 (Work) 890-2223 (Page Number) Assigned To: TSC l STUART, DAVID 0 Longmont 651-1927 (Home) 274 (Work) Assigned To: TSC l l WOJTISEK, JOE O l Aurora f} l 364-2855 (Home) N-l 268 (Work) l l Assigned to: TSC r l i l l FORM (C)372 22-3643
r RERP PHONE LISTS Issue 26 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 69 of 70 0 Service PUBUC SERVICE COMPANY OF COLORADO AV TRAINING Phone Lists Affected BEARLY, PHILIP B. M Loveland 669-6636 (Home) 455 (Work) Assigned To: PCC HOOPER, RON 0. M Northglenn 452-3614 (Home) 458 (Work) Assigned To: PCC MOLER, ROBERT M Longmont 772-9357 (Home) (-) 456 (Work) Assigned To: PCC MURPHY, MIKE M Golden 279-6762 (Home) 454 (Work) Assigned To: PCC RIVERA, RICHARD M Loveland 667-1906 (Home) 453 (Work) Assigned To: PCC SWITZER, JOSEPH R. M Johnstown 587-4134 (Home) 452 (Work) Assigned To: PCC WIEDRICH, HENRY M l Keensburg 732-4494 (Home) 452 (Work) Assigned To: PCC O FORMtC)372 22 3643
c: RERP PHONE LISTS Issue 26 0 Public FORT ST. VRAIN NUCLEAR GENERATING STATION Page 70 of 70 ServlCe PUBUC SERVICE COMPANY OF COLORADO O TRAINING Phone Lists Affected WILLFORD, STEVE R. J,Y Brighton 659-5258 (Home) 450 (Work) Assigned To: PCC O O FORM (Q372 22 3643
.g a.: t. Public Service Company 9 Odands - V 16805 WCR 19 1/2, Platteville, Colorado 80651 March 12, 1985 Fort St. Vrain Unit No. 1 P-85080 Regional Administrator $_@ $ []M @ 'h Region IV-U.S. Nuclear Regulatory Commission 22g 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011 g Attention: Mr. Eric H. Johnson Docket No.: 50-267
Subject:
Radiological Emergency Response Plan (RERP)
Dear Mr. Johnson:
We are transmitting herein revisions to Fort St. Vrain's Station RERP Implementing Procedures. One copy of the RERP-TSC, Issue 15 and RERP-PHONE LISTS, Issue 26 procedures is being transmitted for filing. Attachments, data sheets, checklists, and control lists should immediately follow the procedure. If difficulties or questions arise in filing this procedure, please contact Ms Sharilyn Johnson at (303) 785-2224, extension 285-Sincerely, J. W. Gahm Manager, Nuclear Production i JWG/dal 8 i .>i 9 h ktTUW olllkl %5C&/ ro R.1Y -}}