Amends 57 & 26 to Licenses DPR-70 & DPR-75,respectively, Changing Tech Specs to Delineate Operating Restrictions When One MSIV Solenoid Vent Valve Isolated
ML20107H432
Person / Time
Site: Salem  
(DPR-70-A-057, DPR-70-A-57, DPR-75-A-026, DPR-75-A-26)
Issue date: 10/15/1984
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20107H433 List:
References
NUDOCS 8411090010
Download: ML20107H432 (12)


Text

.

!y *

  • o UNITED STATES

[]

j ~

NUCLEAR REGULATORY COMMISSION

,%v W ASHINGTON O. C. 20555

' y,e. E g lj 1,

,/

PUBLIC SERVICE ELFCTRIC AND GAS COMPANY PHILADELPHIA ELECiHIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANiiG CITY ELECIRIC COMPANY DOCKET NO. 50-272 SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 57 License No. DPR-70 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Public Service Electric and Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated October 5, 1982 and supplemented September 2, 1983, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-70 is hereby amended to read as follows:

8411090010 841015 PDR ADOCK 05000272 P

PDR

. (2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 57, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEA REGULATORY COMMISSION s

te arga 1

Operating Reactors \\ Branch #1 DivisionofLicensin?

Attachment:

Changes to the Technical Specifications Date of Issuance: October 15, 1984 4

ATTACHMENT TO LICENSE AMENDMENT NO. 57 FACILITY OPERATING LICENSE NO. OPR-70 00CKET NO. 50-272 Revise Appendix A as follows:

Remove Pages Insert Pages 3/4 3-18 3/4 3-18 3/4 3-19 3/4 3-19 3/4 3-20 3/4 3-20 t

i

-n--

~

e,

l TABLE 3.3 3 (Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENT?. TION us MINIMLM M

TOTAL NO.

CllANNELS CHANNELS APPLICABLE to 8

FUNCTIONAL UNIT OF CllANNELS TO TRIP OPERABLE MODES ACTION C

b.

Phase "B" Isolation

  • a
1) Hanual 2 sets of 2 1 set of 2 2 sets of 2 1,2,3,4

.18 t

2) Automatic 2

1 2

1,2,3,4 13 Actuation Logic

3) Containment 4

2 3

1,2,3 16 Pressure--liigh-High w

c.

Purge and Exhaust 3:

Isolation 8,

1) Manual 2

1 2

1,2,3,4 17 w

2) Containment Atmo-3 1

2**

1, 2, 3, 4 17 m

sphere Radioactivity-High

!f

    • The unit vent sampling monitor may also function in this capacity with lowered setpoints when the purge / pressure-j' vacuum relief isolation valves are open.

~

TABLE 3.3-3 (Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION y

e HINIMUH TOTAL NO.

CIIANNEIS CilANNELS APPLICABLE OF CllANNELS TO TRIP OPERABLE MODES ACTION FUNCTIONAL UNIT hy 4.

STEAM LINE ISOLATION a.

Manual 1/ steam line 1/ steam line 1/ operating 1, 2, 3 18 b.

Automatic Actuat ion Logic 2***

I 2

1, 2, 3 13 c.

Containment Pressure--

4 2

3 1, 2, 3 16 liigh-liigh J.

Steam Flow in Two d[

Steam Lines--liigh w

Four loops 2/ steam line 1/ steam line 1/ steam line 14*

.c.

b operating any 2 ateam lines e

Three Loops 2/ operating l###/any 1/operat ing steam l in'e operat ing steam line 15 steam line COINCIDElfr WITH EITilER 1

2, 3##

Tavg -Low-Low Four loops h

I Tavg/ loop I Tavg in any 1 Tavg in any g4, i

Operating' 2 loops 3 loops r,

?

      • The automatic actuat ion logic includes two redundant solenoid operated vent valves for each Main Steam

=

Isolation Valve. One vent valve on any one Main Steam Isolation Valve may be isolated without affecting d

the function of the automatic actuation logic provided the remaining seven solenoid vent valves remain operable. The isolated MSIV vent valve shall be returned to OPERABLE status upon the first entry into HODE 5 following determination that the vent valve is inoperable. For any condition where more than one of the eight solenoid vent valves are inoperable, entry into ACTION 13 is required.

~

TABLE 3.3-3 (Continu:d)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION m

J2 t*

HIN1 HUM to2 TOTAL No.

CilANNE LS CllANNELS APPLICABLE FUNCTIONAL UNIT OF CllANNELS TO TRIP OPERABLE HODES ACTION 15 c:

Three Loops 1 Tayg/ operating l### Tavg in 1 Tavg in any 2:

loop any operat ing two operat ing loop loops F'

OR, COINCIDENT WITil 1, 2, 3###

i Steam Line Pressure-Low 14*

Four Loops I pressure /

1 pressure 1 pressure 4

Operat ing loop any 2 loops any 3 loops Three Loops I pressure /

liff pressure I pressure in 15 Operating operating loop in any operating any 2 operating loop loops N

b us 5.

TilRBINE TRIP &

[3 FEEDWATER ISOLATION a.

Steam Generator 3/ loop 2/ loop in any 2/ loop in each 1, 2, 3 14*

o operating loop operating loop Water level--

liigh-Iligh 6.

SAFECUARDS EQUIPMENT 3

2 3

1,2,3,4 13 CONTROL SYSTEM (FEC) 7.

UNDERVO LTACE, VITAL BUS a

2 3

1, 2, 3 14*

a.

Loss of Voltage 3

5 2

3 1, 2, 3 14*

b.

Sustained Degraded 3

=r

?

Voltage U

/,,v 4%,

UNITED STATES o,

[ '*,"4-g' j NUCLEAR REGULATORY COMMISSION i

r E

WASHINGTON. D. C. 20555

-/

ha,//!

% i PUBLIC SERVICE ELECTRIC AND GAS COMPANY PHILADELPHIA ELEGIKIC CUMPAl4Y DELMARVA F0WER AND LIGHT COMPANY ATLAHilG GilY ELEL6KlG COMPANY DOCKET NO. 50-311 SALEM NUCLEAR GENERATING STATION, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 26 License No. DPR-75 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Public Service Electric and Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated October _5,1982 and supplemented September 2,1983, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activir.ies authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be

. conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Spec.fications as indicated in the attachment to this license am(niment, and paragraph 2.C.(2) of Facility Operating License No. DPR-75 is hereby amended to read as follows:

~

. (2) Technical Specifications The Technical Specificctions contained in Appendices A and B, as revised through Amendment No. 26, are hereby incorporated in the license. The if censee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION e

~\\

~4'9as%d%%

Operating Reactors B anch #1 Division of Licen

Attachment:

Changes to the Technical Specifications Date of Issuance: October 15, 1984 s

e ATTACHMENT TO LICENSE AMENDMEllT f 0. 26 FACILITY OPERATING LICENSE NO. DPR-75 00CKET NO. E0-311 Revise Appendix A as follows:

Remove Pages Insert Paces 4

3/4 3-18 3/4 3-18 3/4 3-19 3/4 3-19 3/4 3-20 3/4 3-20 t

e i

a b

m-.

s' TABLE 3.3-3 (Continued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION MINIMUM P'

E TOTAL NO.

CHANNELS CHANNELS APPLICABLE FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION i

N b.

Phase "B" Isolation N

1) Manual 2 sets of 2 1 set of i 2 sets of 2 1,2,3,4 18 n
2) Automatic 2

1 2

1, 2, 3, 4 13 4

Actuation Logic

3) Containment 4

2 3

1,2,3 16 Pressure--High-High 4[

c.

Containment Ventilation Isolation h

1) Manual 2

1 2

1,2,3,4 17 w

m

2) Automatic Actuation 2

1 2

1,2,3,4 13 Logic

3) Containment Atmo-1**

1 1

1,2,3,4 17 sphere Gaseous Radioacti vity-High sampling monitor nay also function in this capacity with lowered setpoints when the purge / pressure-

((

    • The unit vent vacuum relief isolation valves are open.

g[

M=

ct b

- - - - - - - -. ~.. _. _

TABLE 3. 3-3 (Cont inued)

ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION U>>

t*

HINIMUM y

TOTAL NO.

CilANNELS

- CllANNELS APPLICABLE FUNCTIONAL UNIT OF CIIANNELS TO TRIP OPERABLE HODES-ACTION Three Loops 1 Tavg/ operating l### Tavg in i Tavg in any 15 C

2:g loop any operat ang two operating toop loops M

OR, COINCIDENT WITH 1, 2, 3##

Steam Line Pressure-tow 14*

Four Loops -

1 pressure /

1 pressure in I pressure in Operat ing loop any 2 loops any 3 loops I pressure ic 15 4d Three 1 oops I pressure /

If## pressure, any 2 operating 4

Operating operat ing loop in any operating loop loops ta 5.

TURBINE TRIP &

FEEDWATER ISOLATION a.

Steam Generator 3/ loop 2/ loop in any 2/ loop in each 1, 2, 3 14*

Water level--

operating loop operating loop liigh-liigh 6.

SAFEGilARDS EQUIPMENT 3

2 3

1, 2, 3, 4 13-CONTROL SYSTEM (SEC) f 7.

UNDERVOLTACE, VITAL BUS a.

Loss of Voltage 3

2 3

1, 7, 3 14*

a S

P b.

Sustained Degraded 3

2 3

1, 2, 3 14*

=

Voltage os

TABLE 3.3-3 (Continued)

ENCINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION t*

HINIMUM TOTAL NO.

CllANNEl.S CilANNELS APPLICAh!.E FUNCTIONAL UNIT OF CilANNEl.S TO TRIP OPERABLE MODES ACTION i

g Zy 4.

STEAM LINE IS01.ATION a.

Manual 2/ steam line 1/ steam line I/ ope rat ing 1, 2, 3 21 u

steam line b.

Automatic Actuat ion logic 2***

1 2

1, 2, 3 20 c.

Containment Pressure--

4 2

3 1, 2. 3 16 liigh-High d.

Steam Flow in Two Steam Lines--Iligh ta N

Four loops 2/ steam line 1/ steam line 1/ steam line 14*

.t-i Operating any 2 steam g

lines o"

COINCIDENT WITil EITilER 1, 2, 3##

Tavg -low-Low Four 1. oops Oper at ing i Tavg/ loop I Tavg in any 2 1 Tavg in any 14*

g loops 3 loops m:s To

      • The automatic actuation logic includes two redundant solenoid operated vent valves for each Hain Steam 5

Isolation Valve. One vent valve on any one Main Steam Isolation Valve may be isolated without affecting function of the automatic actuation logic provided the remaining seven solenoid ve.it valves remain the P

operable. The isolated HSIV vent valve shall be returned to OPERABLE status upon the first entry into MODE 5 following determination that the vent valve is inoperable. For any condition diere wre than one of the eight solenoid vent valves are inoperable, entry into ACTION 20 is required.

u*

f

- - - - - - _ _ - _ _ _ _ _ _,