1901 Chouteau Avenue "M
Post off ce Box 143 St. Louis. M.ssouri 63166 314 554-2650 UuroN April 12, 1996 Donald F. Schnell Etucmc
?xyc ~"~
E U. S. Nuclear Regulatory Commission ATTN:
Document Control Desk Mail Station Pl-137 Washington, D. C.
20555-0001 Gentlemen:
ULNRC-3358 CALIAWAY PLANT DOCKET NUMBER 50-483 REVISION TO TECHNICAL SPECIFICATION 3/4.4 - REACTOR COOLANT SYSTEM
Reference:
Letter to K. R. Wichman from J. H. Taylor, dated March 26, 1996 Union Electric Company herewith transmits an application for amendment to Facility Operating License Number NPF-30 for Callaway Plant.
This application proposes to change Technical Specification 3/4.4,
" Reactor Coolant System" and associated Bases to l
address the installation of electrosleeves in the Callaway Plant steam generators.
]
Framatome Technologies Inc. has determined that information associated with the installation process for electrosleeves is proprietary.
The installation process for Callaway Plant is described in Topical Report BAW-10219P, Rev. 1 "Electrosleeving Qualification for PWR Recirculating Steam Generator Tube Repair," dated March 1996, which was transmitted to NRC by the referenced letter.
That letter references the original proprietary affidavit provided by Framatome for this process.
The ASME Code does not address the use of electrochemical material deposition for steam generator l
tube repair.
However, a special ASME task group was j
formed to develop a Code Case for this process, and L
Code Case developement is ongoing.
b 9604220200 960412 4
PDR ADOCK 05000483 1
P pnn e
I i
l The Callaway Plant On-Site Review Committee and the Nuclear Safety Review Board have reviewed and approved the amendment request.
Attachments 1 through 5 provide the Technical Specification changes, Safety l
Evaluation, _Significant Hazards Evaluation, and Environmental Consideration, respectively.
We have concluded that this amendment request does not involve an unreviewed safety question as defined in 10CFR50.59, l
nor a significant hazard consideration as determined i
per 10CFR50.92.
Pursuant to 10CFR51.22 (b), no l
environmental impact statement or environmental l
assessment need be prepared in connection with the issuance of this amendment.
i It is requested that this amendment be approved by August 1, 1996, to be effective on the date of issuance and to be implemented within 30 days of the date of issuance.
If you have any questions concerning the amendment application, please contact us.
Very truly yours, Donald F. Schnell I
fBe-I WEK/
Attachments: 1) Technical Specification Changes (marked-up)
- 2) Technical Specification Changes (re-typed)
- 3) Safety Evaluation
- 4) Significant Hazards Evaluation
- 5) Environmental Consideration I
l
I i.
STATE OF MISSOURI
)
l
)
SS COUNTY OF CALLAWAY
)
I I
Alan C.
Passwater, of lawful age, being first duly sworn j
upon oath says that he is Manager, Licensing and Fuels (Nuclear) for Union Electric Company; that he has read the i
foregoing document and knows the content thereof; that he has i
executed the same for and on behalf of said company with full L
power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.
~-
By l
Alan C.
Passwater Manager, Licensing and Fuels Nuclear SUBSCRIBED and sworn to before me this
//d day af 0 hall.
1996.
U i
l l
tbi44 4/A I
BARBARA J. PFAFF(/
6' Q t/ ~
l' NOTARY PUBLIC-STATE OF MISSOURI MY 00MMIS$10N EXPIRES APRIL 22,199Z ST. LOUIS COUNTY l
f' r-
I cc:
T. A. Baxter, Esq.
Shaw, Pittman, Potts & Trowbridge 2300 N. Street, N.W.
Washington, D.C.
20037 M. H. Fletcher Professional Nuclear Consulting, Inc.
19041 Raines Drive Derwood, MD 20855-2432 L. Joe Callan Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive Suite 400 Arlington, TX 76011-8064 Senior Resident Inspector i
Callaway Resident Office I
U.S. Nuclear Regulatory Commission 8201 NRC Road I
Steedman, MO 65077 Kristine M. Thomas (2)
Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 1 White Flint, North, Mail Stop 13E16 l
11555 Rockville Pike l
Rockville, MD 20852-2738 l
l Manager, Electric Department Missouri Public Service Commission i
P.O. Box 360 Jefferson City, MO 65102 Ron Kucera Department of Natural Resources P.O.
Box 176 Jefferson City, MO 65102 Don Woodlan TU Electric 1
1601 Bryan Street i
Dallas, TX 75201-3411 i
Pat Nugent Pacific Gas & Electric Regulatory Services P.O. Box 56 Avila Beach, CA 93424
1 l
1 bec: J. Brandt/A160.761
/QA Record (CA-758)
E210.01 DFS/ Chrono D. F. Schnell J. E. Birk' l
i J. V. Laux R. D. Affolter G. L. Randolph R. J. Irwin
'P. M. Barrett J. D. Blosser A. C. Passwater D. E. Shafer W. E. Kahl S. Wideman (WCNOC)
F.-C. Wilks, PE (Bechtel)
H. D. Bono NSRB (Patty Reynolds)
I l
1 f
l l
l L
l l
4 l
l l
--