y 3'4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS

/

3/4.0 APPLICABILITY LIMITING CONDITION FOR OPERATION Y

i 3.0.1 Limiting Conditions for Operation and ACTION requirements shall be applicable during the OPERATIONAL MODES or'other conditions specified for each specification.

3.0.2 Adherence'to the' requirements of the Limiting Condition for-Operation and/or associated ACTION within the specified time interval shall constitute compliance with the specification..In the event the Limiting Condition for Operation is restored prior to expiration of the specified time interval, completion of.the ACTION statement is not required.

3.0.3 In the event a Limiting Condition for Operation and/or associated ACTION requirements cannot be. satisfied because of circumstances 'in excess of those addressed in the specification, the facility shall be placed in at.least HOT STANDBY within I hour and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> unless corrective measures are completed that permit operation under the permissible ACTION statements for the specified time interval as measured from initial discovery.

Exceptions to these requirements shall be stated in the individual specifications.

3.0.4 Entry into an OPERATIONAL MODE or other specified applicability condition shall not ce made unless the conditions of the Limiting Condition for Operation are met without reliance on provisions contained in the ACTION statements unless otherwise excepted. This provision shall not prevent passage through OPERATIONAL MODES as required to

~

comply with ACTION statements.

SURVEILLANCE REQUIREMENTS 4.0.1 Surveillance Requirements shall be applicable during the OPERA-TIONAL MODES or other conditions specified for_ individual Limiting Conditions for Operation unless otherwise stated in an individual Surveillance Requirement.

4.0.2 Each Surveillance Requirement shall be performed within the specified time interval with:

a.

A maximum allowable extension not to exceed 25% of the surveillance interval, and i

4 P

l CALVERT CLIFFS - UNIT 1 3/4 0-1 8502190060 850212

'~

PlJR ADOCK 05000317 P

PDR

g. y w

.f y n'

u-]'

1 APPLICABILITY' 7

/

SURVEILLANCE RECUIREMENTS'(Continued)

L

.b.

. A' tota 1Lmaximum combined interval-time for any 3 consecutive

~

surveillance intervals: not to exceed 3.25-times the specified surveillance interval..

4 4.0.3. Performance of a Surveillance Requirement within-the.specified 4

time-interval. shall constitute compliance with OPERABILITY requirements for a Limiting Condition for Operation'and associated. ACTION. statements unless otherwise required by-the specification.

Surveillance Requirements" do not have.to be performed on inoperable equipment.

4.0.4 Entr.yintoanOPERATIONALMODEorotherspecifiedapplicability condition shall' not be made unless the Surveillance Requirement (s) l associated with the Limiting Condition for Operation have been performed within the stated surveillance interval or as otherwise specified.

3 ASME Code C1 s%quirements for inservice inspection.an'd test 4.0.5 Surveillance Re and,Lcomponertts-sh b,e_ app cabl follow -

4 a.

For the time period from' issuance of Amendment No. 20 to the l

Facility Operating License to the inservice inspection interval.

starting September 8,.1978, inservice testing of ASME Code Class 1, 2, and 3 pumps and valves shall be.perfomed in accordance l

with Section XI of the. ASME Boiler and Pressure Vessel Code.

1971 Edition, and Addenda through Winter 1973, except where j

specific written relief has been granted by.the Commission.

/t-l b.

For the time period following the start of the inservice -

inspection interval starting September 8,1978, inservice inspection of ASME Code Class 1, 2, and 3 components and '

i inservice testing of ASME Code Class 1, 2, and 3 pumps.and valves shall be performed in accordance with Section XI of the i

ASME Boiler and Pressure Vessel Code and applicable Addenda as required by 10 CFR Part 60, Section 50.55a(g), except where 3

specific written relief has been granted by the Comission pursuant to 10 CFR 50, Section 50.55a(g)(6)(i).

Perfomance of be' 6Tpectt6n and7esttifg Ns -

4 shall be in addition to other specified Surveillance Requirements. The provisions of Specification 4.0.2 are not applicable to surveillance intervals associated with inservice inspection and testing activities required by Section XI of the above ASME Boiler and Pressure Vessel Code l

and applicable Addenda.

i CALVERT CLIFFS - UNIT I 3/4 0-2 i

..