ML20106G940

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Feb 1996 for Browns Ferry Nuclear Plant Units 1,2 & 3
ML20106G940
Person / Time
Site: Browns Ferry  
Issue date: 02/29/1996
From: Davenport J, Machon R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9603190365
Download: ML20106G940 (13)


Text

.

? g-IUA Tennessee VaPey Autnootv. Post Off<ce Box 2000. Decatar, Alabama 35609 2000 R. D. (Rick) Machon Vce Presecent. Orowns Ferry Nuclear Plant March 15, 1996 U.S.

Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 Gentlemen:

In the Matter of

)

Docket Nos. 50-259 Tennessee Valley Authority

)

50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) - MONTHLY OPERATING REPORT FOR THE MONTH OF FEBRUARY 1996 l

In accordance with the requirements of BFN Units 1, 2,

and 3 Technical Specifications, Section 6.9.1.3, TVA is submitting j

the Monthly Operating Report for the month of February 1996 1

in the enclosure.

1 If you nave any questions, please call me at (205) 729-2636.

Sincerely,

.s&0Y" R.

D.

M on Enclosure cc:

See page 2 190045

///

9603190365 960229 ADOCK0500ggg9 I

l PDR R

U.S.

Nuclear Regulatory Commission Page 2 March 15, 1996 Enclosure cc (Enclosure):

Mr. Mark S.

Lesser, Branch Chief U.S.

Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. Frederick J.

Hebdon, Director Project Directorate II-4 Division of Reactor Projects I-II office of Nuclear Reactor Regulation, Mail 13 H3 Washington, D.C.

20555 INPO Records Center Institute of Nuclear Power Operations 700 Galleria Parkway Atlanta, Georgia 30339-5957 Mr. Jim Lang Director of Engineering and Operations Electric Power Research Institute P.

O.

Box 10412 Palo Alto, California 94304 NRC Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road Athens, Alabama 35611 Regional Administrator U.S.

Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Ms. Elizabeth Hannon Utility Data Institute 1200 G Street, NW Washington, D.C.

20005-3802 l

i

_ - =.

ENCLOSURE TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 MONTHLY OPERATING REPORT FEBRUARY 1996 (SEE ATTACHED) 1 l

)

{

l OPERATIONAL

SUMMARY

FEBRUARY 1996 BROWNS FERRY 1 l

Unit i remains shutdown on administrative hold to resolve various TVA and NRC concerns.

Unit 1 has been on administrative hold since June 1, 1985.

As a result, TVA considers that accrual of reporting hours is suspended since the unit has a maximum dependable capacity of 0 MWe.

Accordingly, TVA does not consider cumulative reporting period hours for the period beginning June 1, 1985, when calculating the operating status variables.

BROWNS FERRY 2 During the month Unit 2 operated at a capacity factor of 92.2 percent and generated 701,330 megawatt hours gross electrical power.

As of February 29, 1996, Unit 2 has operated continuously for 193 days.

Unit 2 is presently in coast-down for the cycle 8 refueling outage scheduled to begin on March 22, 1996.

BROWNS FERRY 3 t

During the month Unit 3 operated at a capacity factor of 98.7 percent and generated 750,150 megawatt hours gross electrical power.

After 91 days of continuous operation, Unit 3 reactor scrammed at 0158 hours0.00183 days <br />0.0439 hours <br />2.612434e-4 weeks <br />6.0119e-5 months <br /> on February 29, 1996.

The initiating event was a failed turbine speed feedback card in the Electro-Hydraulic Control system.

The failed card caused fluctuations in the turbine control valves and turbine bypass valves, causing a reactor pressure spike, which in turn caused an Average Power Range Monitor high flux spike, scramming the reactor.

i l

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO:

50-259 UNIT:

BROWNS FERRY 1 PREPARED BY:

J.

W.

Davenoort TELEPHONE:

(205) 729-2690 MONTH FEBRUARY 1996 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 0

16 0

2 0

17 0

3 0

18 0

4 0

19 0

5 0

20 0

6 0

21 0

7 0

22 0

8 0

23 0

9 0

24 0

10 0

25 0

11 0

26 0

12 0

27 0

13 0

28 0

14 0

29 0

15 0

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO:

50-260 UNIT:

BROWNS FERRY 2 PREPARED BY:

J.

W.

Davenoort TELEPHONE:

(205) 729-2690 MONTH FEBRUARY 1996 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 1053 16 988 2

1023 17 984 3

1066 18 982 4

1073 19 943 5

1011 20 965 6

1028 21 932 7

1022 22 916 8

1036 23 963 9

1011 24 950 10 1016 25 958 11 1043 26 938 12 988 27 899 13 1018 28 861 14 980 29 831 15 992

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO:

50-296 UNIT:

BROWNS FERRY 3 PREPARED BY:

J.

W.

Davenoort

)

TELEPHONE:

(205) 729-2690 MONTH FEBRUARY 1996 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 1091 16 1069 2

1071 17 1089 3

1069 18 1084 4

1075 19 1093 5

1070 20 1090 6

1091 21 1093 7

1081 22 1089 i

8 1084 23 1090 9

1086 24 1086 10 1067 25 1089 11 1038 26 1087 12 1077 27 1087 13 1087 28 1071 14 1088 29 192 15 1088

m _.

m UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO:

50-259 REPORT MONTH:

FEBRUARY 1996 UNIT:

BROWNS FERRY 1 PREPARED BY:

J.

W.

Davenport TELEPHONE:

(205) 729-2690 Method of License Duration Shutting Event System Conponent Cause and Corrective Action to Prevent No.

Date Type' (Hours)

Reason' Down Reactor' Report No.

Code' Code' Recurrence 1

06/01/85 S

6%

F 4

Administrative hold to resolve various T.VA and NRC concerns.

l

'F-Forced

'A-Equipment Failure (Expla;n)

' Method:

  • Instructions for Preparation of Licensee S-Scheduled B-Maintenance or Test 1-Manual Event Reports (NUREG-1022)

C-Refueling 2-Manual Scram D Regulatory Restriction 3-Automatic Scram E-Operator Training and License Examination 4-Continuation of Existing Outage F-Administrative 5-Reduction G-Operational Error (Explain) 9-Other H-Other (Explain) t I

m

UNIT SHUTDOWNS AND POWER REDUCTIONS

' DOCKET NO:

50-260

~'

REPORT MONTH:

FEBRUARY 1996 UNIT:

BROWNS FERRY 2 PREPARED BY:'

J.

W.

Davenport TELEPHONE:

(205) 729-2690

-i i

,a Method of License 3

Duration Shutting Event System Component Cause and Corrective Action to Prevent No.

Date Type' (Mours)

Reason' Down Reactor

  • Report No.

Code"-

Code

  • Recurrence N/A I

i i

h i

ki i

'F-Forced

'A-Equipment Failure (Explain)

% thod:

" Instructions for Preparation of Licensee 3

S-Schedated B-Maintenance or Test 1-Manual Event Reports (NUREG-1022) i C-Refueling 2-Manual Scram

^

D-Regulatory Restriction 3-Automatic Scram-E-operator Training and License Examination 4-Continuation of Existing Outage

[

F-Administrative 5-Reduction I

G-Operational Error (Explain) 9-Other M-Other (Explain) b-P

)

.m...-

,, _,., ~ -

,---._,m_,_,---_...

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO: 50-296 REPORT MONTH:

NOVEMBER 1996 UNIT: BROWNS FERRY 3 PREPARED BY:

J.

W.

DavenDort TELEPHONE:

(205) 729-2690 Method of License Duration Shutting Event System Component Cause and Corrective Action to Prevent No.

Date Type' (Hours)

Reason' Down Reactor

  • Report No.

Code' Code

  • Recurrence 1

02/29/%

F 22 A

3 296/96001 JJ CNV A failed turbine speed fee 6 ack card in the Electro-Mydraulic Control system caused fluctuations in the turbine control and b mess valves. This caused a reactor pressure spike, which in turn caused an Average Power Range Monitor high flux spike that scrassed the reactor.

'F-Forced

'A-Equipment Failure (Explain)

' Method:

' Instructions for Preparation of Licensee S-Scheduled B-Maintenance or Test 1-Manual Event Reports (NUREG-1022)

C-Refueting 2-Manumt Scram D-Regulatory Restriction 3-Automatic Scram E-Operator Training and License Examination 4-Continuation of Existing Outage F-Administrative 5-Reduction G-Operational Error (Explain) 9-Other H-Other (Explain)

OPERATING DATA REPORT DOCKET:

50-259 UNIT:

BROWNS FERRY 1 PREPARED BY:

J.

W.

Davenoort TELEPHONES. (205) 729-2690 i

l OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 1
2. Reporting Period:

FEBRUARY 1996

3. Licensed Thermal Power (MWt):

3293

4. Nameplate Rating (Gross MWe):

1152

5. Design Electrical Rating (Net HWe):

1065

6. Maximum Dependable capacity (Gross MWe):

0

7. Maximum Dependable Capacity (Net MWe):

0 8.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A

9. Power Level To Which Restricted, If Any (Net MWe):

0 l

10. Reason For Restrictions, If Any: Administrative Hold l

THIS MONTH YEAR TO DATE CUNULATIVE*

I

11. Hours in Reporting Period 0

0 95743

12. Hours Reactor Was Critical 0

0 59521

13. Reactor Reserve Shutdown Hours 0

0 6997

14. Hours Generator On Line 0

0 58267

15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thermal Generation (MWh) 0 0

168066787

17. Cross Electrical Generation (MWh) 0 0

55398130

18. Net Electrical Generation (HWh) 0 0

53796427 l

19. Unit Service Factor 0

0 60.9

20. Unit Availability Factor 0

0 60.9

21. Unit Capacity Factor (MDC Net) 0 0

52.8

22. Unit Capacity Factor (DER net) 0 0

52.8

23. Unit Forced Outage Rate 0

0 25.6 l

24. Shutdowns Scheduled over Next 6 Months l

(Type, Date, and Duration of Each): N/A i

i

25. If Shut Down At End Of Reporting Period, l

Estimated Date of Startup: To Be Determined

  • Excludes hours under administrative hold (June 1, 1985 to present)

I OPERATING DATA REPORT DOCKET:

50-260 UNIT:

BROWNS FERRY 2 PREPARED BY J.

W.

Davenport TELEPHONE:

(205) 729-2690 OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 2
2. Reporting Period:

FEBRUARY 1996

3. Licensed Thermal Power (MWt):

3293

4. Nameplate Rating (Gross MWe):

1152

5. Design Electrical Rating (Net HWe):

1065

6. Maximum Dependable capacity (Gross MWe):

1098.4

7. Maximum Dependable Capacity (Net MWe):

1065 I

8.

If Changes occur in capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A

9. Power Level To Which Restricted, If Any (Net MWe): N/A
10. Reason For Restrictions, If Any: N/A l

THIS MONTH YEAR TO DATE CUMULATIVE *

11. Hours in Reporting Period 696.0 1440.0 132271
12. Hours Reactor Was Critical 696.0 1440.0 92219
13. Reactor Reserve Shutdown Hours 0.0 0.0 14200
14. Hours Generator On Line 696.0 1440.0 89928
15. Unit Reserve Shutdown Hours 0.0 0.0 0
16. Gross Thermal Generation (MWh) 2142864.0 4566432 263906764 l
17. Gross Electrical Generation (MWh) 701330.0 1506600 87671918
18. Net Electrical Generation (MWh) 683269.0 1469115 85255986
19. Unit Service Factor 100.0 100.0 68.0
20. Unit Availability Factor 100.0 100.0 68.0
21. Unit Capacity Factor (MDC Net) 92.2 95.8 60.5
22. Unit capacity Factor (DER net) 92.2 95.8 60.5
23. Unit Forced Outage Rate 0.0 0.0 15.7
24. Shutdowns Scheduled over Next 6 Months (Type, Date, and Duration of Each): Refueling Outage, March 22, 1996, 35 days
25. If Shut Down At End Of Reporting Period, Estimated Date of Startup: N/A
  • Excludes hours under administrative hold (June 1, 1985 to May 24, 1991)

]

OPERATING DATA REPORT i

DOCKET:

50-296 i

UNIT:

BROWNS FERRY 3 PREPARED BY:

J.

W.

Davenport TELEPHONE:

(205) 729-2690 OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 3
2. Reporting Period:

FEBRUARY 1996

3. Licensed Thermal Power (MWt):

3293

4. Nameplate Rating (Gross MWe):

1152

5. Design Electrical Rating (Net MWe):

1065

6. Maximum Dependable Capacity (Gross MWe):

1098.4

7. Maximum Dependable capacity (Net MWe):

1065 8.

If Changes occur in capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A

9. Power Level To Which Restricted, If Any (Net MWe): N/A
10. Reason For Restrictions, If Any: N/A THIS MONTH YEAR TO DATE CUNULATIVE*
11. Hours in Reporting Period 696.0 1440 75515
12. Hours Reactor Was Critical 674.0 1418 47713 1
13. Reactor Reserve Shutdown Hours 0.0 0

5150

14. Hours Generator On Line 674.0 1418 46423
15. Unit Reserve Shutdown Hours 0.0 0

0

16. Gross Thermal Generation (MWh 2213520.0 4644864 138915145
17. Gross Electrical Generation (MWh) 750150.0 1571540 45835730
18. Net Electrical Generation (MWh) 731352.0 1533633 44412260
19. Unit Service Factor 96.8 98.5 61.5
20. Unit Availability Factor 96.8 98.5 61.5
21. Unit Capacity Factor (MDC Net) 98.7 100.0 55.2
22. Unit Capacity Factor (DER net) 98.7 100.0 55.2
23. Unit Forced Outage Rate 3.2 1.5 20.8
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each): N/A
25. If Shut Down At End Of Reporting Period, Estimated Date of Startup: N/A
  • Excludes hours under administrative hold (June 1, 1985 to November 19, 1995)

!