Provides Assessment of Indications Detected in IGSCC Susceptible Stainless Steel Weldments in Reactor Recirculation Piping Sys & Transmits Weld Overlay Repair Designs & Flawed Pipe Evaluations,Per GL 88-01 & Suppl 1
ML20101Q012
Person / Time
Site: Quad Cities 
Issue date: 04/04/1996
From: Kraft E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20101Q015 List:
References
ESK-96-049, ESK-96-49, GL-88-01, GL-88-1, NUDOCS 9604100137
Download: ML20101Q012 (94)


Text

l nunnmnwealth I.de.on onnpany

]

Qiud Citics Generating $tation 22710 2cSth Asenue North cordova. II. 612424740 Ten ymM22 u ESK-9M49 April 4,1996 l

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555

Subject:

Quad Cities Nuv r ower Station Unit 1 Submittal of Welo Uveday Repair Designs and Flawed Pipe Evaluations

)

NRC Docket No. 50-254 l

References:

(a)

USNRC Generic Letter 88-01 and Supplement 1 (b)

NUREG-0313 Revision 2 The purpose of this letter is to provide Comed's assessment of the indications detected in eight (8) Inter Granular Stress Corrosion Cracking (IGSCC) susceptible stainless steel weldments in the reactor recirculation piping system and to transmit the weld overlay repair designs and the flawed pipe evaluations. In addition, we have included our response to the NRC's questions from the April 1,1996 teleconference between Comed and the NRC.

j Ultrasonic examinations (UT) on IGSCC susceptible weldments were performed during the current QlR14 refuel outage and resulted in eight (8) welds with indications that exceed the acceptance criteria in IWB-3500 of ASME Section XI 1989 Edition. Subsequently, the j

weldments were evaluated using the methodology and acceptance criteria specified in IWB-3640 of ASME Section XI,1989 Edition and/or were scheduled for weld overlay repairs during the current refuel outage. The repairs will consist of a " designed" weld overlay or a

" standard" weld overlay in accordance with Reference (b). The flawed pipe evaluations concluded that a minimum of five (5) hot operating years remain prior to exceeding the allowable flaw size for "wek'ments evaluated for continued service". The Engineering Change Notices (ECN) and Engineering Calculations are included as Attachments 1 and 2.

Weldments Scheduled for Weld Overlav Renair Durine OlR14 02AS-S6 A Recire Pump Suction ECN 04-01337M 02BS-S12 ("

B Recire Pump Suction ECN 04-01333M 02AS-S12 A Recire Pump Suction ECN 04-01345M 02AS-F14 A Recire Pump Suction ECN 04-01344M 02AS-F2 ")

A Recire Pump Suction ECN 04-01339M Weldments Evaluated for Continued Service 02AD-F12 A Recire Pump Discharge Calculation #NED-P-MSD-088 02AS-S4 A Recire Pump Suction Calculation #NED-P-MSD-090 i

02BS-F14 B Recire Pump Suction Calculation #NED-P-MSD-092 1

(" Weldment was evaluated as acceptable for continued service without repair.

.noh I

9604100137 960404 PDR ADOCK 05000254

. O6 P

PDR I \\

A tInicom comp.my

ESK-96 049 April 4,1996 In addition, the following are responses to the questions that the NRC asked during the April 1,1996 teleconference call between Comed and the NRC.

Question 1)

Why were Category D welds not included in the sample expansion based on the results from Category C weld inspections?

Response 1)

Quad Cities Station has committed to perform IGSCC inspections in accordance to the rules of Generic Letter 88-01. The NRC Position on Sample Expansion, which is found on page 5 of the Generic Letter, only requires additional welds of the same IGSCC Category (Category A, B, or C) as that of the flawed welds be selected for any additional samples. Supplement I to Generic Letter 88-01, issued in February 4,1992, provides clarification on the sample expansion rules applicable to IGSCC Category D welds. Supplement 1 does not discuss nor require a sample expansion to include welds in a different IGSCC Category than that of the flawed welds.

During the current refuel outage Q1R14, the Category C sample was expanded twice to include 100% of the Category C welds.

Question 2)

What is the population of Category D Welds?

Response 2)

The total population count for Category D welds in Quad Cities Unit 1 is seven (7) w ' Ids. They are: 02 A-S4, 02 AB-S 10A, 02 AD-S5, 02 BB-S 10, 02 BD-SS, 10HV-F1, and 10S-S3. These Category D welds are included in the original IGSCC UT sample for the current refuel outage, Q1R14.

In conclusion, per the requirements of Reference (a), Comed requests NRC review and acceptance of a return to operating mode of Quad Cities Unit 1 at the end of the scheduled refueling outage. NRC acceptance is requested by April 27,1996.

Please address any further comments or questions regarding this matter to this office.

Sincerely, Y.

f.a E. S. Kraft, Site Vice President Attachments (1)

Engineering Change Notices (2)

Engineering Calculations l

cc:

H. J. Miller, Regional Administrator - Rill (without attachments)

R. M. PulsiFx, Project Manager - NRR C. G. Miller, Senior Resident inspector - Quad Cities Station (without attachments)

Office of Nuclear Facility Safety - IDNS (without attachments)

D. C. Tubbs, R. J. Sir.Te. MidAmerican Energy Company (without attachments)

i l

l i

I (e

1 l

s Y

i

.a VECTRA March 21,1996 1598-00044.002

)

Mr. C. Conner Lead, Comed Inspections Group Commonwealth Edison Company Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, IL 61242-9700 l

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02BS-S12 i

Reactor Recirculation System,0200 "For Construction" ECN Transmittal Letter ECN No.: 04-01333M P.O.No.: 351285/YY-238 Function No.: 052306-3171

Dear Mr. Conner:

The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering Procedures. The following information related to the ECN is provided:

1.

SEC Cognizant Engineer:

T. Wojcik 2.

Modification Number: E04-1-96-023-A 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIlrrION 04-01333M Weld Overlay Repair of Weldment 02BS-S12 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this modification. This ECN may be completed independently of any other work and is being issued as a part of partial modification E04-1-96-023-A to support the Station's outage schedule.

VECTRA Tec"of:;es. Inc.

2'5 SLmo-M. :. e 200

  • Nopemlle..:05t3 Te 708) 7%9100

% ? ' 54343

y Mr. C. Conner Commonwealth Edison

.o 1598-00044.002 Page 2 VECTRA i

5.

Required Hardware Procurement Action:

This modification does not require' any inventory of spare parts. The j

materials are " Cobalt Free" (< 1% Cobalt).

l 6.

ECN Safety Classification:

The ECN is safety related.

7.

Other Related, Open Design Changes:

Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this modification.

8.

Fabrication of parts may proceed without the receipt of a Comed approval letter. However, installation activities shall not proceed until a Comed Authorization letter is received.

9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirem' nts Operability Statement:

e Examination and, acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained stress within a weldment is used to determine the weldment's NUREG-0313, Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repairs in not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

i An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

12.

Spare Parts List:

No spare parts are required.

..-.--r

-m

.- J.

a_k 4

a-t Mr. C. Conner y

Commonwealth Edison 1598-00044.002 Pare 3 VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved:

Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4'.6 FSAR Section 4.3 UFSAR Section 5.4 b.

Affects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections c.

were reviewed:

See Item 14 (a) d.

Is PDC Installation Outage related?

Yes (X)

No()

Work may be conducted during the Q1R14 or later outage.

Is New Design Compatible with Existing System?

c.

Yes. Weld overlay materials are compatible with the existing piping system. W:lding shall be in accordance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Examination of reactor recirculation system weldment 02BS-S12 at Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

Mr. C. Conner

.y Commonwealth Edison 1598-00044.002 Page 4 VECTRA The weldment is located on the suction side of recirculation pump 1-0202B on line 1-0202B-28"-A. In order to permit weld overlay implementation, existing caps, originally used to cover core sample holes, will be removed and filled with flush plugs.

b.

This minor plant change shall be installed in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic l

Stainless Steel Weldments", Latest Revision.

c.

Material requirements are specified in Document No. COE-107-500.

d.

All of the equipment and components associated with ECN l

04-01333M are safety related. No other interferences or interactions with Safety or Class 1E equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

e.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

l If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl Frochlich at (408) 629-9800.

Very truly yours,

{ w$&

ames A. Brown, P.E.

Project Manager JAB / lab Attachment i

y Mr. C. Conner Commonwealth Edison 1598-00044.002 Page5 VECTRA Copies:

S. Eldridge - Quad Cities i

MOD Design Supervisor - Letter only T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package M. Sullivan Site Construction Superintendent - w/1 ECN package M. Santic - Quad Cities System Engineer - w/1 ECN package i

T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture

)

A. Beveroth - Quad Cities SEC DCR Coordinator - w/1 ECN package G. J. Tagatz - Quad Cities Design Change Coordinator - w/ letter only G. Bathje - Quad Cities Materials Management Supervisor - w/1 ECN package Bob Larken - Quad Cities Site Construction - w/1 ECN package j

NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - Ietter only 1598-00044.F09 - 1 ECN Package DTR Book - Letter & ECN Parts 1 & 2 JAB-96-025 l

V ENGINEERING CHANGE NOTICE (Part 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT sCN No. mmm Page 1 of 9 Sianoa:

Ouad Chies N Safsey Rdeud Design Change No. R04-1-96423-A Affected Unit: 1

( ) Noo safety Rdated Project No. W appt) 1598 6 Changes to e previously Approved ECN t ]

[] bgulag Supp ID No &mppL) N/A Symem:

0200 o.cri,

.f D-ism chasseme-Weld overlay repair (WOR) of weldment 02BS-S12 on line 1-0202B-28" of the Reactor Recirculation System.

1 Reanne for Design Chassa: Change and action required (Provide reason for change, apui6c actions required, anach supporting documeess, a applicable).

A weld overlay repair will be applied to weldment 02BS-S12 on line 1-0202B-28" to repair intergranular stress corrosion cracking (IGSCC).

J DfrERFACING COMMENr5 by:

Design Group or Discipline Name of Commenter(Printed)

Signature of Commenter Date C or NC 9.

4Q k4l!96 dC ElectJ1&C bItT Mahanical

)A Vrn k brosb O

d

('.

.-r.,

unes e.,>acaa n gun alu/n ae wad a M.G.

VMEf A. BROW Mb 3/2/[96 N C.

Others

/

?/

1 Prepared by: /

M Review by:

  • 3 C orh Approved by:

7 3/ 4; 3-2f-94, s/2y'%

9 o.ne:

o..:

o.te.

All affected design documenu revised by (date):

verir.ed by:

D.ie:

Reproduced from: NEP 08-01, Issued 9/30/94

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part2)

Associated With:

DCD Number:

04-01333M O

ECN - Comment Station:

On=d Cities Unit: 1 l

E ECN - Construction Plant Design Change / Change Authority:

O- 'FCR Type:

EPC O

Other:

Number:

E04-1-96-023-A Part 1 - General Information - Opnonal for Fca Date Prepared:

3/16/96 A/E:

V006 Project No.:

1598-00044 W.O. or Function No.:

052306-3171 Originator:

Sierel. K.

Organization:

VECTRA Technolonies Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav r=mir of weldment 02BS-S12 on line 1-0202B-28" of the Ranctor Recirculation i

System.

i Part 2 - Related Desien Change Documents (i.e.. ECN. FCR)

Bri Ref.

Hg.

Iype Number No.

Iync Number 1.

5.

l 2.

6.

3.

7.

4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes

_X_ No (optional)

Part 3 - Affected Design Documents DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Code Code Page Up Rev Optional Date DWG-C C502 M-3103 3

E 2

D i

1

    • C' for Construction m 'R' for Record
    • 'F' for Functional g 'D' for Detailed Rrproduced from: NEP 08 01, Issued 9/30/94 Page 2_ of 9

B:ck-Up Calcul ti:n Listing (Part 2)

ECN No. 0441333M Design Change No.: E04-1-96-023-A Page 3 of 9 Calculation / Analysis No.

Revision No.

Description XCE042.0322 0

Weld Overlay Repair Design for Quad Cities Unit 1, Weld 02BS-S12 - 1996 Outage i

I l

l l

Reproduced from: NEP 08 01, Issued 900/94 l

CERTIFICATION PAGE (Part 3)

ECN No. 0441333M Design Change No.: E04-1-%423.A Page 4 of 9 Station:

Ouad Cities Affected Unit:

1 Page:

1 of I CERTIFICATION OF ECN NO.

04-01333M i

i I certify that this Engineering Change Notice was prepared by me or under my supervision and I am a registered Professional Engineer under the laws of the State of Illinois.

4 I

l Certified by:

b Date:

3/2i/9c,

/

f.. i n...,k*

i

.. " "A. B

.4 ih /'062-00931 **.

! REGISTERED %

i Seal i i PROFES3IONAL I i

1, * '. ENGINEER,I

  • 5
  • .,*s...O F.......e./

E

~,

/

%,,..L q y O f,,s'#

\\

........o' Reproduced from: NEP4841. Issued 9/30/94

SUPPORT INFORMATION (Part 4)

ECN No. 0441333M I

Design Change No.: E04-1-96423 A Page 5 of 9 l

4.1 General

]

l l

Note No.

Description I

4.1.1 Core sample plug repairs shall be in accordance with Section 4.2 of Part 4 of this ECN.

l l

4.1.2 Weld overlay application shall be in accordance with page 9 of this ECN (Sketch 1598-00044.010-0207) and shall comply with the technical requirements contained in-Document No. COE-107-500, Latest Revision.

4.1.3 Detailed joint configuration information and thickness data shall be reported to Engmeenng Dn9I to application of the overlay.

i 4.1.4 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, Latest Revision.

4.1.5 The base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler material used for the first layer be selected on the basis of its ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as-deposited). For the first layer, it may therefore be necessary to use filler material capable of producing an undiluted weld deposit double the minimum acceptable delta ferrite specified in COE-107-500.

4.2 Core Plug Renair 4.2.1 This Section describes requirements for the removal of existing plug connections (reference Typical Plug Connection Detail, this ECN page 8) originally installed to cover core samples removed from weldment 02BS-S12 in the mid-1980's. These plug connections will be removed and replaced with backing plugs (reference Backing Plug Installation Detail, this ECN page 8) which in turn will be covered by the weld overlay repair described in Sketch 1598-00044.010-0207 (this ECN page 9).

1 4.2.2

'Ihe work sequence shall be controlled through the use of a process control traveller l

detailing the steps required to perform this work. As a minimum, the following activity sequences shall be described:

4.2.2.1 Identification: Identify candidate weldment, identify core sample branch

)

connection (s), remove interferences, etc.

___m SUPPORT INFORMATION (Part 4)

ECN No. 0441333M Design Change No.: E04-1-96423-A Page 6 of 9 4.2.2.2 Removal: Verify that the run pipe is drained of water, remove plug connection by grinding /saw cutting such that run pipe wall thickness is not reduced, avoid the introduction of any material into the run pipe, use plant-approved tape to cover opening until backing plug welding is begun, etc.

4.2.2.3 Preparation: Obtain and prepare backing plug material, tack weld temporary handling device onto backing plug, dye penetrant (PT) examine backing plug machined surfaces, etc.

4.2.2.4 Welding: Identify appropriate welding procedure and qualified welder, obtain filler material, clean / prepare run pipe and backing plug (avoiding the introduction of any material into the run pipe), fit-up and tack weld backing plug, remove temporary handling device, seal weld backing plug, grind / flap finished seal weld and any remnants of temporary handling device flush with run pipe surface, perform PT and VT examination of welded areas, etc.

4.2.2.5 Overlay Application: Verify that backing plug installation and inspection are complete and that the run pipe is reflooded with water, perform weld overlay repair as described in this ECN.

'4.2.3 The existing run pipe material is type 304 stainless steel. The backing plug material shall be type 304L or 316L stainless steel meeting the requirements of ASME Code Section II and NB-2000 of ASME Section'III. Acceptable product forms from which the backing plugs are to be made include: ASME SA-182, SA-403, SA-240, or SA-479.

4.2.4 Welding filler materials shall be type 308L or 309L meeting the requirements of ASME Code Section II and NB-2000 of ASME Section III. Shielded metal are welding (SMAW) electrodes shall conform to ASME SFA-5.4; gas tungsten arc welding (GTAW) filler metal shall conform to ASME SFA-5.9. Chemical composition of filler material shall be determined in accordance with ASME Section III, NB-2432. Carbon content shall be limited to a maximum of 0.035%. Delta ferrite shall be determined in accordance with NB-2433 and shall not be less that 8 FN nor greater than 20 FN.

4.2.5 All materials shall be supplied with Certified Material Test Reports (CMTR's) from suppliers meeting the requirements of ASME Code Sectice III, NCA-3800.

4.2.6 Welding shall be performed using the SMAW and/or GTAW process (es) in accordance with station-approved welding procedures qualified in accordance with ASME Code Section IX, Welders shall be qualified in accordance with ASME Code Sections IX and XI.

~

SUPPORT INFORMATION (Part 4)

ECN No. 0441333M Design Change No.: E04-1-96423-A Page 7 of 9 4.2.7 The GTAW process, if used, shall be performed with welding grade (or better) argon shielding gas. Post weld heat treatment is not permitted for this repair.

4.2.8 All machined backing plug surfaces (prior to welding), the installation seal weld, and the affected backing plug area after removal of the temporary handling device, shall be PT examined in accordaree with station-approved procedures meeting the acceptance criteria cf ASME Code Section III, Articles NB-4000 and NB-5000.

4.2.9 A system pressure test shall be performed after completion of the weld overlay repair covering the backing plug in accordance with ASME Code Section XI, Article IWA-4400.

4.2.10 The repairs shall be documented on a Code Data Report (NIS-2 or equivalent).

SUPPORT INFORMATION (Part 4)

ECN No.:04 01333M Design Change No.: E04196-023 A Page 1 of 1 l

l l

"" " X

///

)

\\ \\\\

l l

l

/#//i/

\\!\\%

Y Y f Y/

fffffffff/b

/

_ __ s TYPICAL PLUG CONNECTION DETAR.

(TYPICAL 2 PLACES) 1 l

k l

l

,rs otAW WW4E l

l 2 /3===,,,

x

% =.._,

BACKNG PLUG INSTALLATIDN DETAIL

- - - - - - - ~

s AFTER WELD OVERLAY REPAIR 1

i

SUPPORT INFORMATION 0

(Part 4)

ELBOW ECN No.: 04 01333M PIPE Design Change No.: E04-1-96-023-A UPSTREAM Page 9 of 9 (Fina!)

DOWNSTREAM e wao N

/ //./,

, i i wN OVERLAP 1 BEAD (MAK) t-A B

=

=

ge unm l

Amummaw"~weassam

  1. // I l \\ \\%

/

/m NOTES:

)

(1)

This repair shall comply with the technical requirements contained in Document No.

COE-107-500, latest revision.

i (2)

  • t,'is the minimum required design thickness.

(3)

Extend overlay toward branch line as far as possible. 'B' dimension need not exceed 4.5* or shall not be less than 2.5".

DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTER 12ATION COMMENTS t

A B

o 02BS-S12 100% thru wall by 360* length 0.41*

4.S*

(3)

NUREG-0313 Rev.2

' Standard' Overlay Design 0

. f./r/7/ /(Mt /d/96, @d Nftk.,5 dMEk/it; [ -Yal/g issued for Construction.

'3 I

REV.

PREP. BY/

CHK. BY/

P.E. APPR1 E.M. APPR)

P.M. APPR1 DESCRIPTION DATE DATE DATE DATE DATE JOB NO.:

PLANT / UNIT:

REV.

y 1598-00044.010 Quad Cities Unit 1 SHT.

1 0

FILE NO.:

SKETCH NO.:

OF 1

XCE042.0207 1598-00044.010-0207

l l

V

  • e l

VECTRA l

March 23,1996 1598-00044.003 Mr. C. Conner l

1. mad, Comed Inspections Group l

Commonwealth Edison Company l

Quad Cities Nuclear Power Station 22710 206th Avenue North l

Cordova, IL 61242-9700 l

l

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02AS-S6 f

l Reactor Recirculation System,0200 "For Construction" ECN Transmittal Letter l

ECN No.: 04-01337M

]

P.O.No.: 351285/YY-238 Function No.: 052306-3171 l

i

Dear Mr. Conner:

'Ihe purpose of this letter is to transmit "For Construction" the attached Engineering Change l

Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering l

Procedures. The following information related to the ECN is provided:

l 1.

SEC Cognizant Engineer:

T. Wojcik 2.

Exempt Change Number: E04-1-96-023-B 3.

List of ECNs Contained in Package:

l ECN NO.

DESCRIPTION 04-01337M Weld Overlay Repair of Weldment 02AS-S6 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued i

as a part of partial exempt change E04-1-96-023-B to support the Station's outage schedule.

4 l

l 6 ':E' ~~E M i

VECTRA Technolog.es. inc.

215 Shuman SNd., see 200. N::peve, a C563 Te!. ~ E 778- 'Z I

y Mr. C. Conner Commonwealth Edison 1598-00044.003 Page 2 VECTRA I

5.

Required Hardware Procurement Action:

This exempt change does not require any inventory of spare parts.

I The materials are " Cobalt Free" (< 1% Cobalt).

i 6.

ECN Safety Classification:

The ECN is safety related.

7.

Other Related, Open Design Changes:

1 i

Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this exempt change.

8.

Fabrication of parts may proceed without the receipt of a Comed approval letter. However, installation activities shall not proceed until a Comed l

Authorization Letter is received.

i 9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirem'ents Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained j

stress within a weldment is used to determine the weldment's j

NUREG-0313, Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repairs in not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

12.

Spare Parts List:

No spare parts are required.

... ~. - - -

1 L

Mr. C. Conner y

Commonwealth Edison

'6 1598-00044.003 a

Page 3 i

VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved:

Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 b.

Affects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections c.

2 were reviewed:

See Item 14 (a) d.

Is PDC Installation Outage related?

Yes (X)

No()

i Work may be conducted during the Q1R14 or later outage, Is New Design Compatible with Existing System?

e.

Yes. Weld overlay materials are compatible with the existing piping system. Welding shall be in accordance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Examination of reactor recirculation system weldment 02AS-S6 at Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

w

Mr. C. Conner y

Commonwealth Edison 1598-00044.003 Page 4 VECTRA The weldment is located on the suction side of recirculation pump 1-0202A on line 1-0202A-28"-A.

b.

This minor plant change shall be installed in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments", Latest Revision.

c.

Material requirements are specified in Document No. COE-107-500, d.

All of the equipment and components associated with ECN 04-01337M are safety related. No other interferences or interactions with Safety or Class IE equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

e.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl Frochlich at (408) 629-9800.

Very truly yours, 4Ib

/ ames A. Brown, P.E.

Project Manager JAB / lab Attachment v

w

Mr. C. Conner y

Commonwealth Edison 1598-00044.003 Page S VECTRA Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package M. Sullivan - Quad Cities Site Construction Superintendent - w/1 ECN package M. Santic - Quad Cities System Engineer - w/1 ECN package j

T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture A. Beveroth - Quad Cities SEC DCR Coordinator - w/1 ECN package G. J. Tagatz - Quad Cities Design Change Coordinator - w/ letter only G. Bathje - Quad Cities Materials Management Supervisor - w/1 ECN package Bob Larken - Quad Cities 1

Site Construction - w/l ECN package NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - Letter only 1598-00044.F09 - 1 ECN Package DTR Book - Letter & ECN Pans 1 & 2 JAB-96-032

V ENGINEERING CHANGE NOTICE (Part 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT ECN No. mmm Page 1 of 6 I'*

[X] Safety Related Design Change No. E04-1-96423-B Mocted M: I

[ ] Non-Safety Related Prtiect No. & appl) 1598 40044 Changes to a prenously Approved ECN ( l

[] gegulatory supp ID No. g appt)

N/A Syssam:

0200 Danesiption of Design Change Regemt:

)

Weld overlay repair (WOR) of weldment 02AS-S6 on line 1-0202A-28" of the Reactor Recirculation System.

4 Rennes for Design Change: Change and action required (Provide reason for change, specific actions required, attach supportang docums A weld overlay repair, will be applied to weldment 02AS-S6 on line 1-0202A-28" to repair intergranular stress corrosion Craebng (IGSCC).

f l

~

DfrDtFACW COMMEffr5 by:

Design Group or Disepline Name of Commenter (Printed)

Signature of Commenser Dois C or NC muulnC Ai/g Ai/g 4/R.

4 cu r>amsu M = s,L w & % stulu a

es.e w usti A6#W-s /zs/n oc wm M.o.

a. 4. s<ou G= &

2/z.34 c a c.

}

os.r.

/

Prepared by:

[-

k Cor[

Approved by:

-r>

Review by:,

//// la'

/

shs/w r/m/94 a/uAc-o:

o.

o.t. :

/ /

2 All effected design documents revised by (date):

v.rirad by:

D.t.:

I R: produced from: NEP4841. Issued 9/30/94

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2)

Associated With:

DCD Number:

0441337M O

ECN - Comment Station:

On=d Cities Unit:

1 E

ECN - Construction Plant Design Change / Change Authority:

O FCR Type:

EPC O

Other:

Number:

E04-1-96-023-B Part 1 - General Informatinn - Opuonal for FCR Date Prepared:

3/21/%

A/E:

V006 Project No.:

1598-00044 W.O. gr Function No.:

052306-3171 Originator:

Sienel. K.

Organization:

VFfrRA Technal<wien Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav repair of weldment 02AS-S6 on line 1-0202A-28" of the Danetar Paeirculatinn System.

Part 2 - Retsted Desien Channe Documents (i.e.. ECN. FCR)

Eri Ref.

Et Iyg Number No, Iyg Number 1.

5.

2.

6.

3.

7.

4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes _ X._No (optiona0 Part 3 - ARected Design Documents DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark o

Cd Ne Ne Up R"

@dd Date DWG-C C502 M-3103 3

E R

D

    • C' for Construction m 'R' for Record
      • F' for Functional m 'D' for Detailed Reproduced from: NEP48 01, Issued 9/30/94 Page __2__ of 6

B ck-Up Cricult.ti:n Listing (Part 2)

ECN No. 04-01337M Design change No.: E04-196412:R Page 3 of 6 Calculation / Analysis No.

Revision No.

Descriotion XCE042.0323 0

Weld Overlay Repair Design for Quad Cities Unit 1, Welds 02AS-S6,02AS-F2, 02AS-S4,02AD-F12 - 1996 Outage Reproduced from: NEP-08-01, luued 9/30/94

e CERTIFICATION PAGE (Part 3)

ECN No. 0441337M Design Change No.: E04-1-96-023-B Page 4 of 6 Station:

Ouad Cities Affected Unit:

1 Page:

1 of 1 CERTIFICATION OF ECN NO.

04 01337M I certify that this Engineering Change Notice was prepared by me or under my supervision and I am a registered Professional Engineer under the laws of the State of Illinois.

Cenified by:

e_- =Ik Date: s/2d%

's.iisine,,j*

iii A. B

./062 040931 *. 't.

E

! REGISTERED i

! PROFESSIONAL I

~

Seal i

  • 1. ENGINEER /*'

%,*o,,*,*,*. 0F....* ',/

/

'o, ee.I N.O),7 '

L r

...ii' Reproduced from: NEP-08-01, Issued 9/30/94

~-

SUPPORT INFORMATION (Part 4)

ECN No. 0441337M Design Change No.: E04-1-96 023 B Page 5 of 6 4.1 General Note No.

Description 4.1.1 Weld overlay application shall be in accordance with page 6 of this ECN (Sketch 1598-00044.010-0208) and shall comply with the technical requirements contained in Document No. COE-107-500, Latest Revisica.

4.1.2 Detailed joint configuration information and thickness data shall be reported to Engineering pIigt to application of the overlay.

4.1.3 During weld overlay implementation, the "as-buil " configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, I.atest Revision.

4.1.4 The base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler material used for the first layer be selected on the basis of its ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as deposited). For the first layer, it may therefore be nereamry to use filler material capable of producing an undiluted weld deposit double the mindmum acceptable delta ferrite specified in COE-107-500.

SUPPORT INFORMATION

's (Part 4)

PIPE ECN No.: 041337M PIPE Desegn Change No.: E04 1 96-023.B UPSTREAM Page 6 of 6 (Final)

DOWNSTREAM q WELD t* ~

A B

=

/'

W MIN UYP )

U Akl'd$2dni.%g4MtSM&MM?/?&2@?M/PRR@i,

/

/,

/

/

/

NOIES:

(1)

This repair shall comply vnth the technical requirements contained in Document No.

COE-107 500, latest tewston.

(2)

  • t,"is the minimum design thickness.

DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTERIZATION COMMENTS t.

A B

02AS-SS 100% thru wall by 360* length 0.45' 4.5' 4.5" NUREG-0313, Rev. 2

' Standard" Overlay Design I

i D_

0 (e M /g @ M6 f${dkb sh6,bd3/9G issued for Construction.

REV.

PREP.BY/

CHK. BY/

P.E. APPR1 E.MYAPPR) k.M.APPR1 DESCRIPTION DATE DATE DATE DATE DATE JOB NO.:

PLANT / UNIT:

y REV.

1598-00044.010 Quad Cities Unit 1 SHT. 1 FILE NO.:

SKETCH NO.:

0 OF 1

XCE042.0208 1598-00044.010-0208

?

(

'T e

VECTRA i

March 26,1996 1598-00044.004 Mr. C. Conner Lead, Comed Inspections Group Commonwealth Edison Company Quad Cities Nuclear Power Station 22710 206th Avenue North l

Cordowa, IL 61242-9700 l

l

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02AS-F2 i

Reactor Recirculation System,0200 "For Construction" ECN Transmittal letter ECN No.: 04-01339M P.O.No.: 351285/YY-238 Function No.: 052306-3171

Dear Mr. Conner:

The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering Procedures. The following information related to the ECN is provided:

1.

SEC Cognizant Engineer:

T. Wojcik 2.

Exempt Change Number: E04-1-96-023-C 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIPTION 04-01339M Weld Overlay Repair of Weldment 02AS-F2 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued as a part of partial exempt change E04-1-96-023-C to support the Station's outage schedule.

fcx: (708) 778-4343 VECTRA Technolog;es. Inc.

215 Shuman Blvd., Suite 200 Napemiile, IL 60563 Tel: (708) 778 0100

Mr. C. Conn:r 7

Commonwealth Edison 1598-00044.004 Page 2 VECTRA 5.

Required Hardware Procurement Action:

This exempt change does not require any inventory of spare parts.

The materials are " Cobalt Free" (< 1% Cobalt).

6.

ECN Safety Classification:

The ECN is safety related.

7.

Other Related, Open Design Changes:

Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this exempt change.

8.

Fabrication of parts may proceed without the receipt of a Comed approval letter. However, installation activities shall not proceed until a Comed Authorization Letter is received.

9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirements Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," Latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained stress within a weldment is used to determine the weldment's NUREG-0313, Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repairs is not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

12.

Spare Parts List:

No spare parts are required.

)

Mr. C. Conner 7

Commonwealth Edison 1598-00044.004 Page 3 VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved-Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 l

b.

Effects of PDC on Tech. Spec /FSAR/UFSAR Sections:

J 1

Nor.c If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections c.

were reviewed J

See Item 14 (a) d.

Is PDC Installation Outage related?

Yes rX)

No()

Work may be conducted during the Q1R14 or later outage.

e.

Is New Design Compatible with Existing System?

Yes. Weld overlay materials are compatible with the existing piping system. Welding shall be in accordance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Examination of reactor recirculation system weldment 02AS-F2 at Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

o Mr. C. Conner

~7 Commonwealth Edison 1598-00044.004 Page 4 VECTRA The weldment is located on the su'etion side of recirculation pump 1-202A on line 1-0202A-28"-A.

b.

This minor plant change shall be installe.3 in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments", Latest Revision.

c.

Material requirements are specified in Document No. COE-107-500.

j d.

All of the equipment and components associated with ECN 04-01339M are safety related. No other interferences or interactions

]

with Safety or Class 1E equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

l c.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

If you have any questions, please call Rob Choromokos'or me at (708) 778-0100, or Carl Frochlich at (408) 629-9800.

Very tmly yours, IW w

ames A. Brown, P.E.

Project Manager JAB / lab Attachment O

O Mr. C. Conner

-y Cemmonwealth Edison 1598-00044.004 Page5 VECTRA 1

Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package M. Sullivan Sita Construction Superintendent - w/1 ECN package M. Santic - Quad Cities 4

System Engineer - w/1 ECN package T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture A. Beveroth SEC DCR Coordinator - w/1 ECN package G. J. Tagatz - Quad Cities Design Change Coordinator - w/ letter only A. Lynch - Quad Cities Materials Management Supervisor - w/1 ECN package Bob 12rken Site Construction - w/1 ECN package NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - 12tter only 1598-00044.F09 - 1 ECN Package DTR Book - Letter & ECN Parts 1 & 2 JAB-96-033

V ENGINEERING CHANGE NOTICE (Part 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT ECN No. om339M Page 1 of 6 Station:

Ouad Cities N Safety Rehted Design Change No. E04-1-964234 Affected Unit: 1 t ] Non-Safety Related Project No. Or oppt) 1598-00044 Changes to a previously Approved ECN [ ]

[] Reguhtory Supp ID No. Of appl)

N/A System:

0200 Decription of Deign Change Be*

Weld overlay repair (WOR) of weldment 02AS-F2 on line 1-0202A-28" of the Reactor Recirculation i

System.

i Reason for Design Change: Change and action required (Provide reason for change. specific actions required, anach supporttag documents, as applicable).

A weld overlay repair will be app) lied to weldment 02AS-F2 on line 1-0202A-28" to repair intej stress corrosion cracking (IGSCC.

l DfTERFACING COMMENTS by:

Dcaign Group or Discipline Narne of Commenter (Pnnted)

Signature of Commenser Date C or NC Elect./IAC M/4

, A//4 Michanical C/.,of MD4*/.fiW

( d*

k-Mb 3.e 4cu m rcr O fiuma i 3/zu/M, tJ C.

Su aumi we,d a usa.

J.s.uom O!da'r s/zs/n uc Others

/

Prep: red by: Y

-Y Review by:

>>Cor[

Approved by:

d-

/

- y 3!2D!%

Date: 3 U

Date:

O 0 @d Date:

/

/

l All affected design documents revised by (date):

Varified by:

Date:

Reproduced from: NEP-08-01, Issued 9/30/94

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2)

Associated With:

DCD Number:

04-01339M O

ECN - Comment Station:

Onad Citiae Unit: 1 E

ECN - Construction Plant Design Change / Change Authority:

O

'FCR Type:

EPC O

Other:

Number:

E04-1-96-023-C Part 1 - General Information - Optional for FCR Date Prepared:

3/25/96 A/E:

V006 Project No.:

1598-00044 W.O. or Function No.:

052306-3171 Originator:

Siegel. K.

Organization:

VELTRA Technoloeies Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav renair of weldment 02AS-F2 on line 1-0202A-28" of the Danetar Darirculatian System.

Part 2 - Reinted Design Change Documents (i.e. ECN. FCR) l Ecf Ref.

EL Iygn Humher Em Iygn Number 1.

S.,

2.

6.

3.

7.

4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes __ X_No (optional)

Part 3 - Affected Dacien Doc =nents DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or J

R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Code Code Page Up Rev Optional Date I

DWG-C C502 M-3103 3

E R

D 1

    • C' far Construction m 'R' for Record

"*F' for Functional m 'D' for Detailed Reproduced from: NEP48-01, Issued 9/30/94 Page _l._of 6

-rr-er+

e w

e m

Back-Up Calculati:n Listing (Part 2) s BCN No. 04-01339M Design Change No.: E04-1-96-023 C Page 3 of 6 r=1ctitation/ Analysis No.

Revision No.

Description XCE042.0323 1

Weld Overlay Repair Design for Quad Cities Unit 1 - Welds 02AS-56,02AS-F2, 02AS-S4, 02AD-F12 - 1996 Outage Reproduced from: NEP-08-01, lasued 9/30/94

i CERTIFICATION PAGE (Part 3)

ECN No. 04-01339M Design Change No.: E04-1-%.023-C l

Page 4 of 6 Station:

Ouad Cities Affected Unit:

1 Page:

1 of 1 I

CERTIFICATION OF ECN NO.

04-01339M I certify that this Engineering Change Notice was prepared by me or under my supervision and I am a registered Professional Engineer under the laws of the State of Illinois.

Certified by:

h Date:

3/2s./96

/

/

s.A.

/**,062 040931 -fd E

l REGISTERED \\

1-Seal 5 * { PROFESSIONAL li 1,

ENGINEER 1.,*,

,**,*. OF,f': *l

.~

'o,h,,L...IN o.\\,f. '

r Reproduced from: NEP-08-01, Issued 9/30/94

SUPPORT INFORMATION (Part 4)

D ECN No. 0441339M Design Change No.: E04-1-96-023-C Page 5 of 6 4.1 General Note No.

Description 4.1.1 Weld overlay application shall be in asideiice with page 6 of this ECN (Sketch 1598-00044.010-0209) and shall comply with the technical requirements contained in Document No. COE-107-500, Latest Revision.

4.1.2 Detailed joint configuration information and thickness data shall be reported to Engineering gigt to application of the overlay.

4.1.3 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, latest Revision.

1 4.1.4

'Ihe base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler material used for the first layer be selected on the basis of its ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as-deposited). For the first layer, it may therefore be necessary to use filler mMal capable of producing an undiluted weld deposit double the minimum acceptable delta ferrite specified in COE-107-500.

l

'i

)

(

-w-

SUPPORT INFORMATION (Part 4) e SAFE END ECN No.: 04-1339M PIPE Design Change No.: E04-1-96-023-C UPSTREAM Page 6 of 6 (Final)

DOWNSTREAM

( WELD d

A

'

B

=

t' ~

=

[

A ' MIN. (TYP.)

45

\\

v i

  1. 2AMNMMMMdkN#'NOMMDMMMMMMM24

/f

,A

/

A I

NOTES:

(1)

This repair shall comply with the technical requirements contained in Document No.

COE-107-500, latest revision.

(2).

't," is the minimum design thickness.

DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTERIZATION COMMENTS t

A B

o 02AS-F2 100% thru wall by 360* length 0.45" 4.5" 4.5" NUREG-0313, Rev. 2

" Standard' Overlay Design

/g/fg7(A /zs/g d9kf6 N YZY/$g, N/2c,/g 3

0 issued for Construction.

REV.

PRhP.'BY/

CHK. BY/

P.E. APPR1 E.M. APPR1 P.M. APPR1 DESCRIPTION DATE DATE DATE DATE DATE JOB NO.:

PLANT / UNIT:

y REV.

1598-00044.010 Quad Cities Unit 1 SHT.

1 0

FILE NO.:

SKETCH NO.:

OF 1

XCE042.0209 159B-0004 4.010-0209 a

s

+

c VECTRA March 26,1996 1598-00044.005 Mr. C. Conner Lead, Comed Inspections Group Commonwealth Edison Company Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, IL 61242-9700

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02AS-S4 Reactor Recirculation System,0200 "For Construction" ECN Transmittal I.etter ECN No.: 04-01340M P.O.No.: 351285/YY-238 Function No.: 052305-3171

Dear Mr. Conner:

The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering Procedures. The following information related to the ECN is provided:

1.

SEC Cognizant Engineer:

T. Wojcik 2.

Exempt Change Number: E04-1-96-023-D 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIPTION 04-01340M Weld Overlay Repair of Weldment 02AS-S4 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued as a part of partial exempt change E04-1-96-023-D to support the Station's outage schedule.

Noperville, IL 60563. Tel (708) 778-0100 Fax: (708) 778 4343 VECTP.A Technologies, Inc.

215 Shuman Blvd., Suite 200

Mr. C. Conner Commonwealth Edison 1598-00044.005

-o Page 2 VECTRA 5.

Required Hardware Procurement Action:

This exempt change does not require any inventory of spare parts.

The materials are " Cobalt Free" (< 1% Cobalt).

6.

ECN Safety Classification:

The ECN is safety related.

7.

Other Related, Open Design Changes:

Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this exempt change.

8.

Fabrication of parts may proceed without the receipt of a Comed approval i

letter. However, installation activities shall not proceed until a Comed Authorization Letter is received.

9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirements Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, "Tochnical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," I.atest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained i

stress within a weldment is used to determine the weldment's NUREG-0313, Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repairs is not considered an l

ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

1 12.

Spam Parts List:

No spare parts are required.

Mr. C. Conner Commonwealth Edison 1598-00044.005 Page 3 VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved:

Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 b.

Effects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections c.

were reviewed:

See Item 14 (a) d.

Is PDC Installation Outage related?

Yes (X)

No()

Work may be conducted during the Q1R14 or later outage.

Is New Design Compatible with Existing System?

c.

Yes. Weld overlay materials are compatible with the existing piping system. Welding shall be in accordance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Enmination of reactor recirculation system weldment 02AS-S4 at Quad Cities Unit 1 has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

+

s Mr. C. Ccnner Commonwealth Edison i

e 1598-00044.005 Page 4 VECTRA The weldment is located on the suction side of recirculation pump 1-0202A on line 1-0202A-28"-A.

b.

This minor plant change shall be installed in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic j

Stainless Steel Weldments", Latest Revision.

c.

Material requirements are specified in Document No. COE-107-500, d.

All of the equipment and components associated with ECN 04-01340M are safety related. No other interferences or interactions with Safety or Class 1E equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

e.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl Frochlich at (408) 629-9800.

Very truly yours,

%Ib

< ames A. Brown, P.E.

Project Manager JAB / lab Attachment

Mr. C. Conner Commonwealth Edison 1598-00044.005 Page5 VECTRA Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package M. Sullivan Site Construction Superintendent - w/1 ECN package M. Santic - Quad Cities System Engineer - w/1 ECN package T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture A. Beveroth SEC DCR Coordinator - w/1 ECN package G. J. Tagatz - Quad Cities Design Change Coordinator - w/ letter only A. Lynch - Quad Cities Materials Management Supervisor - w/1 ECN package Bob Larken Site Construction - w/1 ECN package NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - Letter only 1598-00044.F09 - 1 ECN Package DTR Book - Letter & ECN Parts 1 & 2 JAB-96-034 4

V i

ENGINEERING CHANGE NOTICE (Part 1) j VECTRA l

ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT sCN No. o4-oi34oM Page 1 of 6 I

statica:

Ouad Cities

[X) Safety Related Desien Change No. E04-1-9M)23-D

[ ] Nos4fetyReissed Project No. & appi.)

1598 00044

}

  • 8 y APPmMN ( )

[] Regulatory supp ID No. & syyi.)

N/A Syslaan:

0200 i

l Descripties of Design Change BW:

I Weld overlay repair (WOR) of weldment 02AS-S4 on line 1-0202A-28" of the Reactor Recirculation i

System.

Reeses for Design Change: Change and action required (Provide reason for change, specific actions required, suech supporting docusasats, as applicable).

l A weld overlay repair will be applied to weldment 02AS-S4 on line 1-0202A-28" to repair intergranular j

stress corrosion cracking (IGSCC).

l l

INTERFACING COMMEPrrS by:

3 Design Group or 1

Dix pline Nerne of Conunenier(Pnnied) signature of Canunesser Date C or NC i

l ElectJIAC X.//,4 N/A Michanical C o# I*JD f82$5d k

5 I

a. c. rJcuuurta 9 T,buud 3/ u. l c< u a

4 s= =->

weid a M i.

s. e. see wrs d4 A--

3/2Vec, ac Others b

l

/

C or h Approved by:

Prepared by:

Review by:

f Dene:

Mb 8b b

k%

Dais:

Date:

/

[

f i

l All effected design docuenents revised by (date):

Vcrifad by:

Dete:

J 4

Reproduced from: NEP-08-01, Issued 9/30/94

-=

.. _ - _ ~ - - - _ -

j DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2) l l

Associated With:

DCD Number:

04-01340M 0

ECN - Comment Station:

Onad Cities Unit:

1 l

I E

ECN - Construction Plant Design Change / Change Authority:

i O'

FCR Type:

EPC

)

O Other:

Number:

E04-1-96-023-D Part 1 - General Information - Opdonal for FCR Date Prepared:

3/25/96 1

A/E:

V006 Project No.:

1598-00044 W.O. QI Fungtion No.:

052306-3171 l

Originator:

Sienel. K.

Organization:

VECTRA Technolonies j

Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav 1.pir of weldment 02AS-S4 on line 1-0202A-28" of the Rametor Recirenintion System.

Part 2 - Ratated Desien Channe Documents (i.e.. ECN. FCR)

Ret Ref.

Iygg Number h

Iype Number 1.

5.

2.

6.

3.

7.

4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes._.X_ No (optional).

Part 3 - Affected Dacien Documents DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Optional Code Code Page Up Rev Date DWG-C C502 M-3103 3

E R

D

  • 'C' for Construction g 'R' for Record
    • 'F' for Functional g 'D' for Detailed Page

_2_ of 6

Reproduced from: NEP-0841, Issued 9/30/94 i

Back-Up Criculatisn Listing (Part 2)

ECN No. 04-01340M D isa chanse No.: E04-1-96-023-D Page 3 of 6 l

Calculation / Analysis No.

Revision No.

Description XCE042.0323 1

Weld Overlay Repair Design for Quad Cities Unit 1 - Welds 02AS-S6,02AS-F2, 02AS-S4,02AD-F12 - 1996 Outage Reprodrced from: NEP-08-01, Issued 9/30/94

r CERTIFICATION PAGE (Part 3)

ECN No. 04 01340M Design Change No.: E04-1-96 023-D Page 4 of 6 i

Station:

Onad Cities Affected Unit:

1 Page:

1 of I l

1 i

CERTIFICATION OF ECN NO.

04-01340M i

1 i

I certify that this Engineering Change Notice was prepared by me or under my supervision and I am a registered Professional Engineer under the laws of the State of Illinois.

1 b

3/2C/9 s Date:

Certified by:

,,.........,/p*

5."A. B

+ +....,,

./,062 040931 I

! REGISTERED

't i.

i PROFES$10NALli *l i

E Seal 5, * \\g 0F,/ /

ENGtNEER 1,

  • 'o$,.L..Y..$,,,o,,fl s

i Reproduced from: NEP-08-01, Issued 9/30/94

_ ~ -

i o

SUPPORT INFORMATION (Part 4)

ECN No. 04-01340M Design Change No.: E04-196 023-D Page 5 of 6 4.1 General Note No.

Description 4.1.1 Weld overlay application shall be in accordance with page 6 of this ECN (Sketch 1598-00044.010-0210) and shall comply with the technical requirements contained in Document No. COE-107-500, latest Revision.

4.1.2 Detailed joint configuration information and thickness data shall be mported to Engineering gior to application of the overlay.

4.1.3 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, Latest Revision.

4.1.4 The base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler matenal used for the first layer be selected on the basis of its ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN -

as-deposited). For the first layer, it may therefore be necessary to use filler material capable of producin; an undiluted weld deposit double the minimum acceptable delte.

ferrite specified in COE-107-500.

i

SUPPORT INFORMATION (Pan 4)

ELBOW ECN No.: 04-1340M.

PIPE Design Change No.: E04-1-96 023-D UPSTREAM Page 6 of 6 (Final)

DOWNSTREAM q, WELD NOTE (3)

\\

t* -

A B

\\\\

[

F MIN. (TYP.)

u

h

/ >hh/Y/YY/Y/Y

'/Y/hh/Y/Y/YY/hhh VV /

/

/

/

/

I NOTES:

(1)

This repair shall comply with the technical requirements contained in Document No.

COE-107-500, latest revision.

(2)

  • t,"is the minimum design thickness.

(3)

Extend overlay towards whip restraint as far as possible. "B" dimension need not exceed 4.5" nor shall be less than 4.0".'

DESIGN DIMENSIONS WELD NUMBER Fl.AW CHARACTERIZATION COMMENTS t

A B

o 02AS-S4 100% thru wall by 360* length 0.45" 4.5" (3)

NUREG-0313 Rev.2

" Standard" Overlay Design

/gg/g MM gg f/ygd W V25/g hs/g 0

issued for Constructon.

/

REV.

PREP. BY/

CHK. BY/

P.E. APPR1 E.M. APPR1

' P.M. APPR1 DESCRIPTION DATE DATE DATE DATE DATE JOB NO.:

PLANTAJNIT:

y REV.

1598-00044.010 Quad Cities Unit 1 SHT.

1 0

FILE NO.:

SKETCH NO.:

OF 1

XCE042.0210 1598-00044.010-0210

1

.t

~~7 VECTRA March 26,1996 l

1598-00044.006 Mr. C. Conner I.ead, Comed Inspections Group l

Commonwealth Edison Company i

Quad Cities Nuclear Power Station l

22710 206th Avenue North Cordova, IL 61242-9700 l

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02AD-F12 l

Reactor Recirculation System,0200 l

"For Construction" ECN Transmittal I.etter ECN No.: 04-01341M P.O.No.: 351285/YY-238 l

Function No.: 052306-3171

Dear Mr. Conner:

l The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering i

Procedures. The following information related to the ECN is provided:

l 1.

SEC Cognizant Engineer:

T. Wojcik 1

l 2.

Exempt Change Number: E04-1-96-023-E 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIPTION 04-01341M Weld Overlay Repair of Weldment 02AD-F12 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued l

as a part of partial exempt change E04-1-96-023-E to support the Station's I

(

outage schedule.

Fax: l708) 778 4343 Noperville, IL 60563. Tel: (708) 778-0100 VECTRA Technologies, Inc.

215 Shuman Blvd., Suite 200

Mr. C. Conn::r

~

7 Commonwealth Edison 1598-00044.006 Page 2 VECTRA 5.

Required Hardware Procurement Action:

This exempt change does not require any inventory of spare parts.

The materials are " Cobalt Free" (< 1% Cobalt).

6.

ECN Safety Classification:

The ECN is safety related.

7.

Other Related, Open Design Changes:

Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this exempt change.

8.

Fabrication of parts may proceed without the receipt of a Comed approval letter. However, installation activities shall not proceed until a Comed Authorization Letter is received.

9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirements Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," Latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained stress within a weldment is used to determine the weldment's NUREG-0313, Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repaira is not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

12.

Spare Parts List:

No spare parts are required.

. - _ =

1 Mr. C. Conner

~

i

-7 Commonwealth Edison 1598-00044.006 Page 3 i

VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

i a.

List of Systems Involved:

0 Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 i

b.

Effects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None U

If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections c.

were reviewed:

4 See Item 14 (a) d.

Is PDC Installation Outage related?

Yes (X)

No()

Work may be conducted during the Q1R14 or later outage.

c.

Is New Design Compatible with Existing System?

Yes. Weld overlay materials are compatible with the existing piping system. Welding shall be in accordance with ASME Scctions IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Examination of reactor recirculation system weldment 02AD-F12 at Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

Mr. C. Conner y

Commonwealth Edison 1598-00044.006 Page 4 VECTRA The weldment is located on the discharge side of recirculation pump 1-0202A on line 1-0202A-28"-A.

b.

This minor plant change shall be installed in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments", Latest Revision.

Material requirements are specified in Document No. COE-107-500.

c.

d.

All of the equipment and components associated with ECN 04-01341M are safety related. No other interferences or interactions with Safety or Class IE equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

c.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl Frochlich at (408) 629-9800.

Very truly yours, Y

m James A. Brown, P.E.

Project Manager JAB / lab Attachment

t

)

7 Mr. C. Conner Ccmmonwealth Edison 1598-00044.006 Page5 VECTRA Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package l

M. Sullivan - Quad Cities Site Construction Superintendent - w/1 ECN package M. Santic - Quad Cities l

System Engineer - w/1 ECN package i

T. Dismukes - Quad Cities l

Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture A. Beveroth - Quad Cities l

SEC DCR Coordinator - w/l ECN package l

G. J. Tagatz - Quad Cities j

i Design Change Coordinator - w/ letter only l

A. Lynch - Quad Cities Materials Management Supervisor - w/1 ECN package Bob Larken - Quad Cities j

Site Construction - w/1 ECN package i

NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package l

File:

1598-00044.D01 - letter only 1598-00044.F09 - 1 ECN Package l

DTR Book - Letter & ECN Parts 1 & 2 l

JAB-96-035 l

l l

I

+

[

-~ -

^

^-

V ENGINEERING CHANGE NOTICE (Part 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT sCN No. o44is4:u 4

Page 1 of 6 Station:

Ouad Cities 4

N Safety Rehud Danign Change No. E041-96423-E Affected Unit:' 1

[ ] Non-Safety Related Project No. Of appt) 1598-00044 Changes to a provmaly Approved ECN t ]

[] Regulatory Supp ID No. Of syPL)

N/A System:

0200 Decripden of Duism Change Be*

j j

Weld overlay repair (WOR) of weldment 02AD-F12 on line 1-0201A-28" of the Reactor Recirculation System.

i Rennen for Design Change: Change and action requimd (Provide reason for change, specific actions required, anach suppostang documenta, as applicable).

]

A weld overlay repair will be applied to weldment 02AD-F12 on line 1-0201A-28" to repair intergranular stress corrosion cracking (IGSCC).

DrrERFACING COMMENTS by:

Desi n Group or Dischline Name of Commenter (Printed)

Signature of Commenter Date C or NC Elect /IAC d//A A//4 Mechanical O.us dnO4CSSOM

(&

3/ '/b A[d Structural

.,J. C.

McetitAurCf(

h,pf;,gg j, 3 h [ C (,

dC f

we:d n uatl.

J. A. BMo w k

3/2&/9 C tv c Others

/

Review by:

Cor[

Approved by:

I Prepared by-Date: k M k[

Date:

I0 b

Date:

2-90

(

/

All affected design documents revised by (date):

Verifad by:

Date:

Reproduced from: NEP-084t, Issued 9/30/94

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2)

Associated With:

DCD Number:

04-01341M O

ECN - Comment Station:

Onnd Cities Unit:

1 G3 ECN - Construction Plant Design Change / Change Authority:

O FCR Type:

EPC O

Other:

Number:

E04-1-96-023-E Part 1 - General Information - Optional for FCR Date Prepared:

3/25/36 A/E:

V006 Project No.: ___1598-00044 W.O. gr Function No.:

052306-3171 Originator:

Sierel. K.

Organization:

VECTRA Technolories s

Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav reoair of weldment 02AD-F12 on line 1-0201 A-28" of the Reactor Recirculation System.

Part 2 - Related Desien Chance Documents (i.e.. ECN. FCR) l Ecf

Ref, j

NRL Iygg Number Iygg Number l

1.

5.

2.

6.

=

3.

7.

i 4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes X No (optional)

Part 3 - Affected Desien Documents

)

DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Code Code Page Up Rev Optional Date DWG-C C502 M-3103 2

E, R

D 1

    • C' for Construction g 'R' for Record
      • F' for Functional m 'D' for Detailed Reproduced from: NEP 0841, Issued 9/30/94 Page 7 of 6

?

Back-Up Calculation Listing (Part 2)

ECN No. 0441341M Design Change No.: E04-196-023-E Page 3 of 6 Onlenindan/ Analysis No.

Revision No.

Descrigion XCE042.0323 1

Weld Overlay Repair Design for Quad Cities Unit 1 - Welds 02AS-S6, 02AS-F2, 02AS-S4,02AD-F12 - 1996 Outage l

Reproduced from: NEP 08-01, Issued 9/30/94

CER,TIFICATION PAGE (Part 3)

ECN No. 0441341M Design Change No.: E04-1-96-023-E Page 4 of 6 Stati:n:

Onnd Cities Affected Unit:

1 Page:

1 of 1 CERTIFICATION OF ECN NO.

04-01341M I certify that this Engineering Change Notice was prepared by me or under my supervision and I am a registered Professional Engineer under the laws of the State of Blinois.

b Date: 7/26/94 Certified by:

e

/

, sienee,,

/

Nif1h I, f REGISTERED iPROFESS I

i t

Seal Q%,*,, \\**. ENGINEER

/ *f OF j'

b,,L,,,IN O\\f /p e

Rrproduced from: NEP-08-01, Issued 9/30/94

SUPPORT INFORMATION (Part 4)

,e BCN No. 04-01341M Demgn Change No.: E04-1-96-023-E Page 5 of 6 4.1 General Note No.

Description 4.1.1 Weld overlay application shall be in m:cordance with page 6 of this ECN (Sketch 1598-00044.010-0211) and shall comply with the tehnial requirements contained in Document No. COE-107-500, Latest Revision.

4.1.2 Detailed joint configuration information and thickness data shall be reported to Engineering gigt to application of the overlay.

4.1.3 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Dmment No. COE-107-500, Latest Revision.

4.1.4 The base materials to which this WOR is to be applied contain low levels of dcita ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the sv ld filier material used for the first layer be selected on the basis of its ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as-deposited). For the first layer, it may therefore be necessary to use filler material capable of producing an undiluted weld deposit double the minimum secchle delta ferrite specified in COE-107-500.

l j

e

SUPPOPJr INFORMATION (Part 4) 1 i

PIPE ECN No.: 041341M PUMP Design Change No.: E04-1-96-023-E DOWNSTREAM Page 6 of 6(Final)

UPSTREAM

]

Q WELD A

:

B

=

t' ~

=

[

45' MIN. (TYP.)

NOTE (3) fhfl92Q$&k&g>$$f>>M>VMMb&$$)>%%'^"'

//

l NOTES:

f (1)

This repair shall comply with the technical requirements contained in Document No.

COE-107-500, latest revision.

4 (2)

%"is the minimum design thickness.

(3)

Extend overlay toward pump casing as far as possible. *B" dimension need not exceed 4.5".

Toe of overlay to blend smoothlyinto pump transition..

DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTERIZATION COMMENTS t

A B

o 02AD-F12 100% thru wall by 360' length 0.49' 4.5" (3)

NUREG-0313, Rev. 2 i

" Standard" Overlay Design 4

Shg 7(m W hl f f t $/Z fr/y b WLS/$4 nW3h&G 0 /

luued tw Contu&n.

<i REV.

PREP. BY/

CHK. BY/

P.E. APPR1 E.M. APPR1 P.M. APPR1 DESCRIPTION DATE DATE DATE DATE DATE JOB NO.:

PLANT / UNIT:

y REV.

1598-00044.010 Quad Cities Unit 1 SHT.

1 FILE NO.:

SKETCH NO.:

OF 1

XCE042.0211 1598-00044.010-0211 i

i

3.

V i

l VECTRA March 29,1996 1598-00044.008 Mr. C. Conner Lead, Comed Inspections Group i

Commonwealth Edison Company Quad Cities Nuclear Power Station 22710 2%th Avenue North Cordova, IL 61242-9700 j

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02AS-F14 Reactor Recirculation System,0200 "For Construction" ECN Transmittal letter ECN No.: 04-01344M P.O.No.: 351285/YY-238 Function No.: 052306-3171

Dear Mr. Conner:

The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering Procedures. The following information related to the ECN is provided:

1.

SEC Cognizant Engineer:

T. Wojcik 2.

Exempt Change Number: E04-1-96-023-G 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIPTION 04-01344M Weld Overlay Repair of Weldment 02AS-F14 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued as a part of partial exempt change E04-1-96-023-G to support the Station's outage schedule.

Fen 708) 776 4343 VECTRA Techno;ogies, Inc.

215 Sn.~r 5 c. Sw'e 200 Noperviile, il 60563 Tei- (708) 778 0100

I Mr. C. Conner

)

gy Commonwealth Edison 1598-00044.008 Page 2 VECTRA I

5.

Required Hardware Procurement Action:

This exempt change does not require any inventory of spare parts.

j The materials are " Cobalt Free" (< 1% Cobalt).

6.

ECN Safety Classification:

l The ECN is safety related.

l l

7.

Other Related, Open Desig. Changes:

l Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this exempt change.

8.

Fabrication of pans may proceed without the receipt of a Comed approval I

letter. However, installation activities shall not proceed until a Comed i

Authorization Letter is received.

I 9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirements Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the l

Application ard Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," Latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained stress within a weldment is used to determine the weldment's NUREG-0313 Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repairs is not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

12.

Spare Parts List:

i i

\\

No spare parts are required.

1 i

y Mr. C. Conner Commonwealth Edison 1598-00044.008 Page 3 VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved:

Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 b.

Effects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None c.

If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections were reviewed:

l l

See Item 14 (a) d.

Is PDC Installation Outage related?

Yes (X)

No()

Work may be conducted during the Q1R14 or later outage, e.

Is New Design Compatible with Existing System?

Yes. Weld overlay materials are compe.nble with the existing piping system. Welding shall be in acccrdance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

i 14.

Other Information:

i Enf neenng Synopsis:

a.

Examination of reactor recirculation system weldment 02AS-F14 at Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

1 l

y Mr. C. Conner Commonwealth Edison 1598-00044.008 Page 4 VECTRA The weldment is located on the suction side of recirculation pump 1-0202A on line 1-0202A-28"-A.

b.

'Ihis minor plant change shall be installed in accordance with l

Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments", Latest Revision, i

l c.

Material requirements are specified in Document No. COE-107-500.

d.

All of the equipment and components associated with ECN i

04-01344M are safety related. No other interferences or interactions with Safety or Class IE equipment exist. Weld overlay axial l

shrinkage will be evaluated by Engineering, see item 10.

l l

e.

No interfaces with other A/Es are required.

l 15.

No engineering assumptions were used in preparing this ECN.

l l

l If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl l

Frochlich at (408) 629-9800.

l l

Very truly yours,'

l b

b

~

ames A. Brown, P.E.

Project Manager JAB / lab Attachment e

3

Mr. C. Conner y

Commonwealth Edison 1598-00044.008 Page 5

)

VECTRA l

Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities i

SEC Cognizant Engineer - w/1 ECN package M. Sullivan Site Construction Superintendent - w/l ECN package i

M. Santic - Quad Cities System Engineer - w/1 ECN package T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture A. Beveroth SEC DCR Coordinator - w/l ECN package G. J. Tagatz - Quad Cities Design Change Coordinator - w/ letter only A. Lynch - Quad Cities Materials Management Supervisor - w/1 ECN package Bob Larken Site Construction - w/1 ECN package NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - Letter only 1598-00044.F09 - 1 ECN Package DTR Book - Letter & ECN Parts 1 & 2 JAB-96-039 i

4

1 Y

ENGINEERING CHANGE NOTICE

^

(Pan 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT ECs NomouM Page 1 of 6 Station:

Ouad Cities N safety Related Design Change No. E04-1-96423-0 ANected Unit: I l ) Non-Safety Related Project No. W ay,L) 1598 N Changes to a previously Approved ECN ( )

[] Regulatory Supp ID No. W aryL) N/A System:

0200

'l Description of Design Change Request:

Weld overlay repair (WOR) of weldment 02AS-F14 on line 1-0202A-28" of the Reactor Recirculation System.

l Renaos for Design Change: Change and action required (Provde reason for change, specific, actions required, anach supporung documents, as applicable).

A weld overlay repair will be applied to weldment 02AS-F14 on line 1-0202A-28" to repair intergranular stress Corrosion Cracking (IGSCC).

DUDLFACING COMMENTS by:

Design Group or Discipline Name of Commenter(Printed)

Signature of Commenur Date C or NC acctanC Ai/A At/A me vn du?&KL/

3/es/%

uc M-h-a, Suuctural

l. E. Acu.a.a64 rsR Mhd Mte /9L MC r

Weld & Matt.

d.A.BRoww QM 7/29/9G ac Ms,

A,//

Prepared by Review by:

/ hC or h Approved by:

r-3/29/96 Date:

[

Date:

/f S

De

/

/

All affected design documents revised by (date):

Verified by:

Date:

Reproduced from: NEP48-01, Issued 9/30/94

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2)

Associated With:

DCD Number:

04-01344M O

ECN - Comment Station:

Ouad Cities Unit: 1 DD ECN - Construction Plant Design Change / Change Authority:

O FCR Type:

EPC O

Other:

Number:

E04-1-96-023-G Part 1 - General Information - opnonal for FCR Date Prepared:

3/28/96 A/E:

V006 Project No.:

1598-00044 W.O. or Function No.:

052306-3171 Originator:

Siegel. K.

Organization:

VECTRA Technolonies i

Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav reoair of weldment 02AS-F14 on line 1-0202A-28" of the Reactor Recirculation System.

Part 2 - Related Design Change Documents (i.e. ECN. FCR)

Est Ref.

NA Iypc Number Iyg; Number 1.

5.

2.

6.

3.

7.

l 4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes X No (op6onal) s i

Par 13 - Affected Desien Documents l

DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Code Code Page Up Rev Optional Date 4

DWG-C C502 M-3103 3

E R

D

C' for Construc6on m 'R' for Record

"*F' for Func6onal m 'D' for Detailed Reproduced from: NEP4841, Issued 9/30/94 Page 2 of 6

B:ck-Up Cdcut:ti:n Listing (Part 2)

ECN No. 0441344M Design Change No.: E04-1-964234 Page 3 of 6 Calculation / Analysis No.

Revision No.

Descriotion XCE042.0325 0

Weld Overlay Repair Design for Quad Cities Unit 1 - Welds 02AS-S12, 02AS-F14 - 1996 Outage Reproduced from: NEP4841, Issued 9/30/94

CERTIFICATION PAGE (Part 3)

ECN No. 0441344M 4

Design Change No.: E04-1-%423-0 Page 4 of 6 1

Station:

Ouad Cities Affected Unit:

1 Page:

1 of I CERTIFICATION OF ECN NO.

04-01344M J

I certify that this Engineering Change Notice was prepared by me or under my supervision 4

and I am a registered Professional Engineer under the laws of the State of Illinois.

4 I

i Certified by:

Mb Date: 3/29/%

's..........,k -

h. B

....**....,*5

~

! [/'062 040931 *.

l' i.

REGISTERED i i, i

PROFESSIONAL :

Seal i * \\ ENGINEER /*$

.....,,,/

's,,,'*'.,...O F,.L...i N R1 produced from: NEP48-01, luued 9/30/94

b SUPPORT INFORMATION (Part 4)

ECN No. 0441344M Design Change No.: E04-1-96423-0 Page 5 of 6 4,1 General Note No.

Description 4.1.1 Weld overlay application shall be in accordance with page 6 of this ECN (Sketch 1598-00044.010-0214) and shall comply with the technical requirements contained in Document No. COE-107-500, Latest Revision.

4.1.2 Detailed joint configuration information and thickness data shall be reported to Engineering yngI to application of the overlay.

4.1.3 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, Latest Revision.

4.1.4 The base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler material used for the first layer be selected on the basis ofits ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as-deposited). For the first layer, it may therefore be necessary to use filler material capable of producing an undiluted weld deposit double the minimum acceptable delta ferrite specified in COE-107-500.

SUPPORT INFORMATION (Part 4)

PIPE ECN No.: 04-1344M ELBOW Design Change No.: E04-196-023-G UPSTREAM Page 6 of 6 (Final)

DOWNSTREAM

{ WB.D CMRAP18EAD pX)

Hil l t \\ \\M A

B g

=

emm t, -

,e n o) o M

\\ \\% auwam>~~~wysygy

/-

/

NOTES:

(1)

This repair shall comply with the technical requirements contained in Document No.

COE-107-500,!atest revision.

(2)

"t,"is the minimum required design thickness.

(3)

Extend overlay toward elbow and branch line as far as possible. 'A' and 'B' dimensions l

need not exceed 4.5". "A" dimension shall not be less than 2.5". Toe of overlay to blend smoothlyinto elbow transition.

i DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTERt2ATION COMMENTS t,

A B

02AS-F14 100% thru was by 360' length 0.48' (3)

(3)

NUREG-0313, Rev. 2

  • Standard" Overlay Design

)pg&#l '/t4/K N4 3/M/94 Y'/% <f3/21/9 0

Issued for Construction.

REV.

PREh.dY/

CHK. BY/

P.E. APPR1 E.M. APPR1 P.M. APPR1 DESCRIPTION I

DATE DATE DATE DATE DATE JOB NO.:

PLANT / UNIT:

y REV.

1598-00044.010 Quad Cities Unit 1 SHT.

1 0

FILE NO.:

SKETCH NO.:

OF 1

VECTRA XCE042.0214 1598-00044.010-0214

v 1,,

VECTRA March 29,1996 1598-00044.007 Mr. C. Conner Lead, Comed Inspections Group Commonwealth Edison Company Quad Cities Nuclear Power Station 22710 2%th Avenue North Cordova, IL 61242-9700

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02AS S12 Reactor Recirculation System,0200 "For Construction" ECN Transmittal Letter ECN No.: 04-01345M P.O.No.: 351285/YY-238 Function No.: 052306-3171

Dear Mr. Conner:

l The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering Procedures. The following information related to the ECN is provided:

1.

SEC Cognizant Engineer:

T. Wojcik 2.

Exempt Change Number: E04-1-96-023-F 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIPTION 04-01345M Weld Overlay Repair of Weldment 02AS-S12 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued as a part of partial exempt change E04-1-96-023-F to support the Station's outage schedule.

Teh (702; 776 0100 NopeMlle, IL 60563 S 08) 778 4343 VECTRA Technologies, Inc.

215 Shsman Bi,d.. Su e 200

y Mr. C. Conner Commonwealth Edison s

1598-00044.007 Page 2 1

VECTRA i

1 5.

Required Hardware Procurement Action:

i i

This exempt change does not require any inventory of spare parts.

1 The materials are " Cobalt Free" (< 1% Cobalt).

6.

ECN Safety Classification:

I l

The ECN is safety related.

i j

7.

Other Related, Open Design Changes:

i i

Comed Station Central File has been contacted and VECTRA has I

determined that no open DCDs are related to this exempt change, 8.

Fabrication of parts may proceed without the receipt of a Comed approval letter. However, installation activities shall not proceed until a Comed Authorization letter is received.

9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirements Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," Latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained stress within a weldment is used to determine the weldment's NUREG-0313, Revision 2, inspection category / frequency. Changes in piping system stress due to weld overlay repairs is not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For Construction" ECN in accordance with VECTRA's Procedures.

12.

Spare Parts List:

No spare parts are required.

y Mr. C. Conner Commonwealth Edison 1598-00044.007 Page 3 VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved:

Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 b.

Effects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None c.

If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections were reviewed:

See Item 14 (a) d.

Is PDC Installation Outage related?

Yes (X)

No()

Work may be conducted during the QlR14 or later outage.

e.

Is New Design Compatible with Existing System?

Yes. Weld overlay materials are compatible with the existing piping system. Welding shall be in accordance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Examination of reactor recirculation system weldment 02AS-S12 at Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

y Mr. C. Conner Commonwealth Edison 1598-00044.007 Page 4 VECTRA 1

)

The weldment is located on the suction side of recirculation pump i

1-0202A on line 1-0202A-28"-A.

i b.

This minor plant change shall be installed in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments", Latest Revision, c.

Material requirements are specified in Document No. COE-107-500.

d.

All of the equipment and components associated with ECN 04-01345M are safety related. No other interferences or interactions with Safety or Class IE equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

c.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl

)

Frochlich at (408) 629-9800.

Very truly yours, m

James A. Brown, P.E.

Project Manager JAB / lab Attachment 4

.a

~

a Mr. C. Conner y

Commonwealth Edison 1598-00044.007 Page 5 VECTRA Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package M. Sullivan Site Construction Superintendent - w/1 ECN package M. Santic - Quad Cities System Engineer - w/1 ECN package T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture 1

A. Beveroth SEC DCR Coordinator - w/l ECN package G. J. Tagatz - Quad Cities i

Design Change Coordinator - w/ letter only A. Lynch - Quad Cities Materials Management Supervisor - w/l ECN package Bob Larken Site Construction - w/1 ECN package NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - 12tter only 1598-00044.F09 - 1 ECN Package DTR Book - Iztter & ECN Parts 1 & 2 JAB-96-038 1

V ENGINEERING CHANGE NOTICE

.e (Part 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR. COMMENT EcN No. wiusM i

Page 1 of 6 Station:

Ouad Cities N safety Relawd Denge Change No. E04-1.M-F Affected Unit: 1

[ ] Noo-SafetyRelated Project No. s areia 1598 N Changes to a previously Approved ECN [ ]

() Regulatory supp ID No. g syyt.)

N/A j

Sysiam:

0200 l

i D.uripcio..f pois. ch se Rw-Weld overlay repair (WOR) of weldment 02AS-S12 on line 1-0202A-28" of the Reactor Recirculation System.

Re.no for Design Change: Change and action tsquired (Provide reason for change, specific actions required, anach supporting documents, as applicable).

A weld overlay repair will be applied to weldment 02AS-S12 on line 1-0202A-28" to repair intergranular stress corrosion cracking (IGSCC).

DUERFACING COMMENTS by:

Design Group or Discipline Name of Commenter (Prinsed)

Signature of Comtnenser Dets C or NC Elect /IAC A//A A//4 h, f, ghgu$y

( W//

3/SV&

kh Mechanical strucimi J. E,. M e u g a u u n.

%E Nw.M 3/1e l %

Wald & Matt.

). A. SR.OWN hjb 3[2T[TG

^/ C Ai/A n/A Review by:

W4'

+,Coch Approved by:

Prepared by; v

fv Data:

N/

Dets: 3[M h

Date: 3 di 96 i

/

i All affected design documents revised by (date):

verified by:

Date:

Rcproduced from: NEP-08-01, Issued 9/30/94

)

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2)

Associated With:

DCD Number:

04-01345M O

ECN - Comment Station:

On=d Cities Unit:

1

[E ECN - Construction Plant Design Change / Change Authority:

O FCR Type: _

EPC O

Other:

Number:

E04-1-96-023-F Part 1 - General Information - Optional for FCR Date Prepared:

3/28/96 A/E:

V006 Project No.:

1598-00044 W.O. p.t Function No.:

052306-3171 Originator:

Siegel. K.

Organization:

VECTRA Technologies Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlav reoair of weldment 02AS-S12 on line 1-0202A-28" of the Reactor Recirculation System.

Part 2 - Related Design Change Documents (i.e. ECN. FCR)

ECL Ref.

NA Iypc Number NA Iygg Number 1.

5.

2.

6.

3.

7.

4.

8.

Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes X No Part 3 - Affected Deslan Documents DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Code Code Page Up Rev Optional Date DWG-C C502 M-3103 3

E R

D

    • C' for Construction s 'R' for Record
      • F' for Functional m 'D' for Detailed Riproduced from: NEP-08-01, Issued 9/30/94 Page 2 of 6

r Brck-Up Cdcul:tirn Listing (Part 2) l ECN No. 04-01345M l

Design Change No.: E04-1-96 023-F Page 1 of 6_

Calculation / Analysis No.

Revision No.

Descriotion t

l XCE042.0325 0

Weld Overlay Repair Design for Quad Cities Unit 1 - Welds 02AS-S12, l

02AS-F14 - 1996 Outage l

l l

l i

l l

l l

I l

l i

}

f Reproduced from: NEP-08-01, Issued 9/30/94

o SUPPORT INFORMATION (Part 4) l ECN No. 0441345M Design Change No.: E04-1-96423-F Page 5 of 6 4.1 General Note No.

Description 4.1.1 Weld overlay application shall be in accordance with page 6 of this ECN (Sketch 1598-00044.010-0213) and shall comply with the technical requirements contained in Document No. COE-107-500, I.atest Revision.

4.1.2 Detailed joint configuration information and thickness data shall be reported to j

Engineering plioI to application of the overlay.

4.1.3 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, I.atest Revision.

4.1.4 The base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler material used for the first layer be selected on the basis of its ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as-deposited). For the first layer, it may therefore be necessary to use filler material capable of producing an undiluted weld deposit double the minimum acceptable delta ferrite specified in COE-107-500.

SUPPORT INFORMATION (Pan 4)

ELBOW ECN No.: 04-01345M PIPE Design Change No.: E04-196-023-F UPSTREAM Page 6 of 6 (Fina0 DOWNSTREAM N

s wao

/ // / / I \\ \\ \\\\ N OVERtAP 10EAD(MAK)

^

B t*

[

wun(M1 manaawm a*>&aama#~l K YI

/

/

1 NOTES:

(1)

This repair shall comply with the technical requirements contained in Document No.

COE-107-500, latest revision.

(2)

"t,'is the minimum required design thickness.

(3)

Extend overlay toward branch line as far as possible. '8' dimension need not exceed 4.5" por shall be less than 2.5".

DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTERtZATION COMMENTS t.

A B

02AS-S12 100% thru was ty 360' length 0.50" 4.5' (3)

NUREG-0313, Rev. 2

' Standard' Overlay Design

/29h $5Ihl% 5 3lZfl9C ON5 #5/3C.

3/24}4t,,

issued for Construction.

0 I

REV.

PdEP./BY/

CHK. BY/

P.E. APPR1 E.M. APPR)

P.M. APPR1 DESCRIPTION DATE DATE DATE DATE DATE JOB NO.:

PLANT / UNIT:

REV.

y 1598-00044.010 Quad Cities Unit 1 SHT.

1 0

FILE NO.:

SKETCH NO.:

OF 1

VECTRA XCE042.0213 1598-00044.010-0213

i o

.c VECTRA April 2,1996 1598-00044.013 Mr. C. Conner Izad, Comed Inspections Group Commonwealth Edison Company Quad Cities Nuclear Power Station 22710 206th Avenue North 4

Cordova, IL 61242-9700

Subject:

Quad Cities Nuclear Power Station Unit 1 Weld Overlay Repair of Weldment 02BS-F14 Reactor Recirculation System,0200 "For Construction" ECN Transmittal Ietter ECN No.: 04-01346M P.O.No.: 351285/YY-238 Function No.: 052306-3171

Dear Mr. Conner:

The purpose of this letter is to transmit "For Construction" the attached Engineering Change Notice (ECN) in accordance with Commonwealth Edison Company's Nuclear Engineering Procedures. The following information related to the ECN' is provided:

1.

SEC Cognizant Engineer:

T. Wojcik 2.

Exempt Change Number: E04-1-96-023-H 3.

List of ECNs Contained in Package:

ECN NO.

DESCRIPTION 04-01346M Weld Overlay Repair of Weldment 02BS-F14 in the Reactor Recirculation System.

4.

Additional ECNs may be required to complete this exempt change. This ECN may be completed independently of any other work and is being issued as a part of partial exempt change E04-1-96-023-H to support the Station's outage schedule.

VECTRA Tecmolog.es, Inc, 215 SL : 5.:. :,ee 200 Nocerviiie. Il 60563 Tel: {708) 778 0100 For.'7081778 4343

Mr. C. Conner y

Comm:nwealth Edison

+

1598-00044.013 Page 2 VECTRA 5.

Required Hardware Procun: ment Action:

This exempt change does not require any inventory of spare parts.

The materials are " Cobalt Free" (< 1% Cobalt).

6.

ECN Safety Classification:

The ECN is safety related.

7.

Other Related, Open Design Changes:

Comed Station Central File has been contacted and VECTRA has determined that no open DCDs are related to this exempt change.

1 8.

Fabrication of parts may proceed without the receipt of a Comed approval letter. However, installation activities shall not proceed until a Comed Authorization letter is received.

9.

VECTRA requests that Comed submit a DCR after the ECN is installed to update the affected design documents.

10.

Acceptance Criteria / Interfacing Requirements Operability Statement:

Examination and acceptance criteria shall be in accordance with Document No. COE-107-500, " Technical Requirements for the Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments," Latest Revision. This application document requires the measurement of weld overlay axial shrinkage which is used by Engineering to determine the state of sustained stress at unrepaired weldments in the system. The magnitude of sustained stress within a weldment is used to determine the weldment's NUREG-0313, Revision 2, inspection category / frequency. Piping system stress due to weld overlay repairs is not considered an ASME BPVC load case.

11.

Interdisciplinary Review:

An interdisciplinary review (IR) has been conducted on the "For 1

Construction" ECN in accordance with VECTRA's Procedures.

1 12.

Spare Parts List:

l No spare parts are required.

Mr. C. Conner y

Csmmonwealth Edison 1598-00044.013

.c Page 3 VECTRA 13.

Technical Specification /FSAR/UFSAR Document Review Verification.

a.

List of Systems Involved:

1 Reactor Recirculation System 0200 Applicable Tech. Spec /FSAR/UFSAR Sections:

Tech. Spec. Sections 3.6/4.6 FSAR Section 4.3 UFSAR Section 5.4 b.

Effects of PDC on Tech. Spec /FSAR/UFSAR Sections:

None If no Tech. Spec /FSAR/UFSAR Sections affected, which Sections c.

were reviewed:

See Item 14 (a) d.

Is PDC Installation Outage related?

1 Yes (X)

No()

1 Work may be conducted during the QlR14 or later outage.

e.

Is New Design Compatible with Existing System?

Yes. Weld overlay materials are compatible with the existing piping system. Welding shall be in accordance with ASME Sections IX, XI, and Document No. COE-107-500. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

14.

Other Information:

a.

Engineering Synopsis:

Examination of reactor recirculation system weldment 02BS-F14 at

)

Quad Cities Unit I has identified intergranular stress corrosion cracking (IGSCC). To ensure the integrity of the weldment and the recirculation piping system, a weld overlay repair will be performed.

Mr. C. Conner y

Commonwealth Edison 1598-00044.013 Page 4 j

VECTRA The weldment is located on the suction side of recirculation pump 1-0202B on line 1-0202B-28"-A.

b.

This minor plant change shall be installed in accordance with Document No. COE-107-500, " Technical Requirements for the l

Application and Examination of Weld Overlay Repairs to Austenitic Stainless Steel Weldments", Latest Revision.

c.

Material requirements are specified in Document No. COE-107-500.

I d.

All of the equipment and components associated with ECN 04-01346M are safety related. No other interferences or interactions with Safety or Class 1E equipment exist. Weld overlay axial shrinkage will be evaluated by Engineering, see item 10.

c.

No interfaces with other A/Es are required.

15.

No engineering assumptions were used in preparing this ECN.

i If you have any questions, please call Rob Choromokos or me at (708) 778-0100, or Carl Frochlich at (408) 629-9800.

1 Very truly yours, am YW ames A. Brown, P.E.

Project Manager JAB / lab Attachment l

i

Mr. C. Conner y

Ccmmonwealth Edison 1598-00044.013 Pagd 5 VECTRA Copies:

S. Eldridge - Quad Cities MOD Design Supervisor - w/1 ECN package T. Wojcik - Quad Cities SEC Cognizant Engineer - w/1 ECN package M. Sullivan - Quad Cities Site Construction Superintendent - w/1 ECN package M. Santic - Quad Cities System Engineer - w/1 ECN package T. Dismukes - Quad Cities Station Central File Supervisor - w/2 ECNs & 1 Silver Aperture A. Beveroth - Quad Cities SEC DCR Coordinator - w/l ECN package G. J. Tagatz - Quad Cities Design Change Coordinator - w/ letter only A. Lynch - Quad Cities Materials Management Supervisor - w/1 ECN package Bob 12rken - Quad Cities Site Construction - w/1 ECN package NETS /CHRON System Supervisor C. H. Frochlich - w/1 ECN Package File:

1598-00044.D01 - Letter only 1598-00044.F09 - 1 ECN Package DTR Book - Letter & ECN Parts 1 & 2 JAB-96-040 9

Y ENGINEERING CHANGE NOTICE (Part 1)

VECTRA ISSUANCE: [ X ] FOR CONSTRUCTION [ ] FOR COMMENT ECN No. m*w Page 1 of 6 l

Station:

Ouad Cities

[X] Safety Related Design Change No. E04-1-96-023-H Affected Unit: 1

[ ] Non-Safety Related Project No. or sopl.)

1598 6 Changes to a previously Approved ECN [ ]

[] Regulatory Supp ID No. Of appl)

N/A Syssem:

0200 D=crim of D-ig. Chang. R c:

Weld overlay repair (WOR) of weldment 02BS-F14 on line 1-0202B-28" of the Reactor Recirculation System.

Ranson for Design Change: Change and action requireri (Provide rosson for change, specific actions required, anach supporung documents, as applicable).

l A weld overlay repair will be applied to weldment 02BS-F14 on line 1-0202B-28" to repair intergranular stress corrosion Cracking (IGSCC).

INTERFACING COMMENrS by:

Design Group or Diecipline Name of Commenter (Printed)

Sigmture of Commesser Data CorNC f//A Al/A ElectJ1&C kg hgygg A

Michanical i

s="'

CHARLE6 G. PKOYUM Pf

+f2-l%

NC Wald & Mati.

J. 4. M CAAJ>4 hw _

1

(,

NC l

~"

N/A N/A Prepared by:

750 b

I Corh Approved by:

Review by:

/

)

Date:

Dois:

2-b Date:

2-0 All affected design documeau revised by (date):

Verified by:

Date:

R: produced from: NEP-08-01, luued 9/30/94

DESIGN CHANGE DOCUMENT - AFFECTED DOCUMENT LIST (Part 2)

Associated With:

DCD Number:

04-01346M O

ECN - Comment Station:

On=A Cities Unit:

1 DD ECN - Construction Plant Design Change / Change Authority:

O FCR Type:

EPC O

Other:

Number:

E04-1-96-023-H Part 1 - General Information - Optional for FCR Date Prepared:

4/02/96 A/E:

V006 Project No.:

1598-00044 W.O. gr Function No.:

052306-3171 Originator:

Siegel. K.

Organization:

VECTRA Technolonien Department:

N/A Phone No./ Ext:

(708) 778-4266

==

Description:==

Weld overlay reonir of weldment 02BS-F14 on line 1-0202B-28" of the Danctor Dacirenistion System.

Part 2 - Related Desien Channe Documents (i.e. ECN. FCR)

EfL Ref.

NA Iyps Number h

Iyps Number 1.

5.

2.

6.

3.

7.

l 4.

8.

l Control Room Drawings Affected?

Yes X No P & ids Affected:

Yes

_X_._No (optional)

Part 3 - Affected Desien Documents DESIGN DOCUMENT (DD)

C F

Crit.

Related DCDs Incorp.

/

/

Drwg.

(Ref # from Rev. or R*

D Part 2)

Date Type Vndr Number Sheet /

Mark Code Code Page Up Rev Optional Date DWG-C C502 M-3103 3

E R

D

    • C' far Construction pI 'R' for Record

"'F' for Functional pr 'D' for Detailed Reproduced from: NEP 08-01, Issued 900/94 Page _ 2_ of 6

i

Back-Up Calculati:n Listing (Pan 2)

.=

ECN No. 04-01346M Design Change No.: E04-1-96-023-H Page 3 of 6 Calenistion/Annivsis No.

Revision No.

Description XCE042.0324 0

Weld Overlay Rept'a Design for Quad Cities Unit 1 - Weld 02BS-F14 - 1996 Outage l

l 4

Reproduced from: NEP-08-01, Issued 9/30/94

CERTIFICATION PAGE (Part 3)

ECN No. 04-01346M Design Change No.: E04-1-%023-H Page 4 of 6 Station:

Ouad Cities Affected Unit:

1 Page:

1 of 1 i

CERTIFICATION OF ECN NO.

04-01346M I certify that this Engineering Change Notice was prepared by me or under my supervision and I am a registered Professional Engineer under the laws of the State cf Illinois.

b-Date:

4h G

Certified by:/

~

w l

i "d..... n s a, '

A. Bj l

. 062 040931 *.

5

! REGISTERED i i

l Seal i

i PROFESSIONAL i !

i

  • I. ENGINEER /*!

.,s,,

.*...OF....*,,/ j p~

,.L...I N O.), +

Reproduced from: NEP-08 01. Issued 9/30/94

~

SUPPORT INFORMATION (Part 4)

ECN No. 04-01346M Desigo Change No.: E04-1-96-023-H Page 5 of 6 4.1 General Note No.

Description 4.1.1 Weld overlay application shall be in accordance with page 6 of this ECN (Sketch 1598-00044.010-0212) and shall comply with the tar hair al requirements contained in Document No. COE-107-500, Latest Revision.

i 4.1.2 Detailed joint configuration information and thickness data shall be reported to Engineering gig to application of the overlay.

4.1.3 During weld overlay implementation, the "as-built" configuration shall be recorded on a Weld Overlay Data Sheet as specified in Document No. COE-107-500, I.atest Revision.

4.1.4 The base materials to which this WOR is to be applied contain low levels of delta ferrite (<5 FN). In an effort to compensate for the dilution effect this low ferrite material will have on deposited weld metal, it is recommended that the weld filler j

material used for the first layer be selected on the basis ofits ability to produce a deposit meeting the requirements of Document No. COE-107-500 (minimum 7.5 FN as-deposited). For the first layer, it may therefore be necessary to use filler material capable of producing an undiluted weld deposit double the minimum acceptable delta ferrite specified in COE 207-500.

~i

SUPPORT INFORMATION (Part 4)

.O PIPE ECN No.: 04-1346M ELBOW Design Change No.: E041-96-023-H UPSTREAM Page 6 of 6 (Final)

DOWNSTREAM q, WELD A

'

B

=

t* ~

=

[

4' MIN. (TYP.)

NOTE (3) y A&W&&&i@&R@me^&&&&&W'?

W

/s

//

l NOTES:

(1)

This repair shall comply with the technical requirements contained in Documer:t No.

COE-107-500, latest revision.

(2)

"t,"is the minimum required design thickness.

(3)

Extend overlay toward elbow as far as possible. 'B' dimension need not exceed 4.5". Toe of overlay to blend smoothly into elbow transition.

DESIGN DIMENSIONS WELD NUMBER FLAW CHARACTER!ZATION COMMENTS t

A B

o 02BS-F14 100% thru wall by 360* length 0.43' 4.5" (3)

NUREG-0313, Rev. 2

  • Standard' Overlay DesiDn

$ fh/94 ffg' V///g g 4//[fG @ Nt/% kg/2/9(,

0 lesued for Construction.

l.M.APPR1 DESCRIPTION REV.

PREP. BY/

CHK. BY/

P.E. APPR1 E.M. APPR1 P

DATE DATE DATE DATE DATE JOB NO.:

PLANTA > NIT:

y REV.

1598-00044.010 Quad Cities Unit 1 SHT.

1 0

FILE NO.:

SKETCH NO.:

OF 1

XCE042.0212 1598-00044.010-0212

__.._.___.___.-_.._._._____m..

'l i

J t

r W

e 1

4 f

i l

l I

't T

f 1

1 t

t 9

'I 4

e 1

a d

T 1

+

4 h

4 1

-. -