i GENE-T1500013-002 DRF No. T15-00013 March 1996 GIRAFFE TEST Apparent Test Results Report (ATR)

Helium Series Tests (H)

H-3 & H-4 Tests

'h J

Prepared by:

' [ HeMog, Senior EnginVerf h

SBWR Test Responsible Engineer 1

9603180329 960314 ADOCK052Og4 PDR

l GENE-T1500013-002 l

IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT PLEASE READ CAREFULLY The only undertakings of the General Electric Company (GE) respecting information in this document are contained in the contract between the customer and GE, as identified in the purchase order for this report and nothing in this document shall be construed as changing the contract. The use of this information by anyone other than the customer or for any purpose other than that for which it is intended, is not authorized; and with respect to any unauthorized use, GE and Toshiba make no representation or warranty, and assume no liability as to the completeness, accuracy, or usefulness of the information contained in this document.

i i

GENE-T1500013-002 TABLE OF CONTENTS Page 1.0. TEST

SUMMARY

I 2.0 TEST CONCLUSION 1

l 3.0 MAJOR TEST RESULTS 1

4.0 TEST ANOMALIES and FAILED INSTRUMENTS 2

5.0 REFERENCES

2 I

i I

ii

.~-

.=

GENE-T1500013-002 LIST OF FIGURES FIGURE PAGE j

1 TEST H-3 D/W and W/W Pressures 3

2 TEST H-3 Non-condensable Gas Vent and LOCA Vent Water Levels 4

3 TEST H-3 D/W Temperature 5

j 4

TEST H-3 PCC Tube Bulk Fluid temperature 6

5A TEST H-3 Suppression Pool Surface Temperature 7

5B Differential Pressure Measurement Locations in S/C 8

6 TEST H-3 PCC Inlet Flow Rate 9

j 7

TEST H-4 D/ N and W/W Pressures 10 8

TEST H-4 Non-condensable Gas Vent and LOCA Vent Water Levels 11 1

9 TEST H-4 D/W Temperature 12 10 TEST H-4 PCC Tube Bulk Fluid temperature 13 11 TEST H-4 Suppression Pool Surface Temperature 14 12 TEST H-4 PCC Inlet Flow Rate 15 iii

i GENE-T1500013-002 ABBREVIATIONS AND ACRONYMS J

D/W Drywell GE General Electric GIRAFFE Gravity-Driven Integral Full-Height Test for Passive Heat Removal LOCA Loss-of-Coolant Accident PCC Passive Containment Cooling (System)

SBWR Simplified Boiling Water Reactor S/C Suppression Chanber TOGE Toshiba/GE W/W Wetwell iv

GENE-T1500013-002 1.0 TEST

SUMMARY

The objectives of tests H-3 and H-4 are to demonstrate the operation of a passive containment cooling system with the presence of a high concentration oflighter-than-steam non-condensable gas and to provide a database for computer codes used to predict SBWR contaimnent system performance in the presence of a lighter-than-steam non-condensable gas.

Test H-3 and H-4 initial conditions are provided in Reference 1. The test procedures and instrument locations are proprietary information.

Test H-3 started with a mixture of nitrogen, helium and steam in the drywell. Helium is used to simulate the hydrogen that could be generated as the result of a fuel-clad metal water reaction. The total initial drywell pressure and all other initial test conditions for test H-3 were the same as those for the base case, test H-1.

Test H-4 started with the same initial test conditions as those for the base case, test H-1.

Helium was injected into the drywell at a constant rate for the Erst hour of the test. The mass of helium injected for test H-4 was equal to the initial mass of helium in the drywell for test H-3.

2.0 CONCLUSION

For both tests H-3 and H-4, the D/W peak pressures were confirmed to be well below the design limit. These tests demonstrated the successful operation of the PCCS with the presence of a heavier-than-steam and a high concentration of a lighter-than-steam non-condensable gas.

3.0 MAJOR TEST RESULTS 3.1 Test H-3 Results The test results provided in Figures 1 through 6 are proprietary information.

The figure 1 plots of the measured D/W and W/W pressures are proprietary information.

The figure 2 plots of the measured water levels in the non-condensable gas vent line and the LOCA vent line are proprietary information. The figure 5B locations of the differential pressure measurement locations are proprietary information.

The figure 3 plots of the measured D/W temperatures at the seven thermocouple locations are proprietary information.

The figure 4 plots of the measured PCC tube bulk fluid temperatures are proprietary information.

\\

J l

GENE-T1500013-002 3.1 Test H-3 Results(Continued) l The figure 5A plot of the measured suppression pool surface temperature is proprietary 3

information.

The figure 6 plot of the preliminary measured PCC inlet flow rate is proprietary

]

information.

1 i

3.2 Test H-4 Results The test results provided in Figures 7 through 12 are proprietary information.

The figure 7 plots of the measured D/W and W/W pressures are proprietary information.

The figure 8 plots of the measured water levels in the non-condensable gas vent line and the LOCA vent line are proprietary information.

i The figure 9 plots of the measured D/W temperatures at the seven thermocouple locations are proprietary information.

The figure 10 plots of the measured PCC tube bulk fluid temperatures are proprietary information.

The figure 11 plot of the measured suppression pool surface temperature is proprietary information.

The figure 12 plot of the preliminary measured PCC inlet flow rate is proprietary information.

4.0 TEST ANOMALIES and FAILED INSTRUMENTS There were no test anomalies or failed instruments

5.0 REFERENCES

1. GIRAFFE IIelium Test Specification, General Electric Company Specification 25A5677, rev.1, May 1995 7-

i.

GENE-T1500013-002 FIGURE I TEST H-3 D/W and W/W PRESSURES W

h

GENE-T1500013-002 FIGURE 2 TEST H-3 NON-CONDENSABLE GAS VENT and LOCA VENT WATER LEVELS

GENE-T1500013-002 FIGURE 3 TEST H-3 D/W TEMPERATURE i

A

l i

it O

2 00-3 1

000 5

1 T-E N

EG ER UT A

R EPM ET D

IU LF K

LU B

E B

U T

C C

P 3

H T

SE T

4 ERUG IF T

GENE-T1500013-002 FIGURE 5A TEST H-3 SUPPRESSION POOL SURFACE TEMPERATURE N

^

s

...L.e-,,

e GENE-T1500013-002 FIGURE SB DIFFERENTIAL PRESSURE MEASUIEMENT LOCATIONS IN S/C

200-3 1

0005 1

T-EN EG ETAR WO LF TELN I

CC P

3-H TSET 6

E R

U G

I F

o_

i p

i t

1 GENE-T1500013-002 I

FIGURE 7 TEST H-4 D/W and W/W PRESSURES 4

O i

200-3 1

0005 1

T-EN EG SLEVEL R

ETAW TN EV ACO L

dna TN EV SAG ELRA SN EDNO C-NON 4

-H TSET 8

ERUG IF C

GENE-T1500013-002 FIGURE 9 TEST H-4 D/W TEMPERATURE A

m-

I GENE-T1500013-002 FIGURE 10 TEST H-4 PCC TUBE BULK FLUID TEMPERATURE U

4 GENE-T1500013-002 FIGURE 11 TEST H-4 SUPPIESSION POOL SURFACE TEMPERATURE i

i

l i

i l

I GENE-T1500013-002 FIGURE 12 TEST H-4 PCC INLET FLOW RATE I

l l

i l

l i

l i

1 I

t