GENE-T1500013-001 DRF No. T15-00013 March 1996 l
\\
l l
I GIRAFFE TEST Apparent Test Results Report (ATR) i Helium Series Tests (H)
H-1 & H-2 Tests
- lM,<44~
Prepared by: ' M. hog, Senior Engfnfe[/
i SBWR Test Responsible Engineer I
9603180325 960314 PDR ADOCK 05200004 A
.h i
GENE-T1500013-001 IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT PLEASE READ CAREFULLY The only undertakings of the General Electric Company (GE) respecting information in this document are contained in the contract between the customer and GE, as identified in the purchase order for this report and nothing in this document shall be construed as changing the contract. The use of this information by anyone other than the customer or for any purpose other than that for which it is intended, is not authorized; and with respect to any unauthorized use, GE and Toshiba make no representation or warranty, and assume no liability as to the completeness, accuracy, or usefulness of the information contained in this document.
)
\\
k
GENE-T1500013-001 TABLE OF CONTENTS 1
Page 1.0 TEST
SUMMARY
1 l
2.0 TEST CONCLUSION 1
3.0 MAJOR TEST RESULTS 1
4.0 - TEST ANOMALIES and FAILED INSTRUMENTS 2
5.0 REFERENCES
2 l
r t
i j
ii
i GENE-T1500013-001 LIST OF FIGURES j
FIGURE PAGE 1
TEST H-1 D/W and W/W Pressures 3
2 TEST H-1 Non-condensable Gas Vent and LOCA Vent Water Levels 4
3 TEST H-1 D/W Temperature 5
4 TEST H-1 PCC Tube Bulk Fluid tempcrature 6
)
5A TEST H-1 Suppression Pool Surface Temperature 7
5B Differential Pressure Measurement Locations in S/C 8
6 TEST H-1 PCC Inlet Flow Rate 9
7 TEST H-2 D/W and W/W Pressures 10 8
TEST H-2 Non-condensable Gas Vent and LOCA Vent Water Levels 11 9
TEST H-2 D/W Temperature 12 10 TEST H-2 PCC Tube Bulk Fluid temperature 13 11 TEST H-2 Suppression Pool Surface Temperature 14 12 TEST H-2 PCC Inlet Flow Rate 15 iii
i
.~
l GENE-T1500013-001 ABBREVIATIONS AND ACRONYMS d
i j
D/W Drywell.
i GIRAFFE Gravity-Driven Integral Full-Height Test for Passive Heat Removal i
a j
. Loss-of-Coolant Accident PCC Passive Containment Cooling (System) 3 i
SBWR Simplified Boiling Water Reactor 1
S/C Suppression Chamber 2
TOGE Toshiba/GE F
f W/W Wetwell
?
i 1
i 1
i l
i
,I f
I
~
.IV f
I GENE-T1500013-001 1.0 TEST
SUMMARY
The objectives of tests H-1 and H-2 are to demonstrate the operation of a passive containment cooling system with the presence of a lighter-than-steam non-condensable gas and to provide a database for computer codes used to predict SBWR containment system performance in the presence of a lighter-than-steam non-condensable gas.
The H-1 and H-2 test initial conditions are provided in Reference 1. The test procedures and instrument locations are proprietary information.
Test H-1 is a base case with nominal initial conditions for the SBWR containment at one hour from the initiation of a LOCA caused by a guillotine rupture of one of the main steam lines. At the start of Test H-1, the drywell contains a mixture of steam and nitrogen at a total pressure of approximately 0.3 MPa. Test H-2 is a repeat of Test H-1, except helium replaces the total volume of nitrogen in the drywell.
2.0 CONCLUSION
For both tests H-1 and H-2, the D/W peak pressures were confirmed to be well below the design limit. These tests demonstrated the successful operation of the PCCS with the presence of a heavier-than-steam and a lighter-than-steam non-condensable gas.
3.0 MAJOR TEST RESULTS 3.1 Test H-1 Results The test results provided in Figures 1 through 6 are proprietary information.
The figure 1 plots of the measured D/W and W/W pressures are proprietary information.
)
The figure 2 plots of the measured water levels in the non-condensable gas vent line and the LOCA vent line are proprietary information. The figure SB locations of the differential pressure measurement locations are proprietary information.
The figure 3 plots of the measured D/W temperatures at the seven thermocouple locations are proprietary information.
The figure 4 plots of the measured PCC tube bulk fluid temperatures are proprietary information.
The figure 5A plot of the measured suppression pool surface temperature is proprietary information.
The figure 6 plot of the preliminary measured PCC inlet flow rate is proprietary information.
\\
GENE-T1500013-001 3.2 Test H-2 Results The test results provided in Figures 7 through 12 are proprietary information.
The figure 7 plots of the measured D/W and W/W pressures are proprietary information.
The figure 8 plots of the measured water levels in the non-condensable gas vent line and the LOCA vent line are proprietary information.
The figure 9 plots of the measured D/W temperatures at the seven thermocouple locations are proprietary information.
l The figure 10 plots of the measured PCC tube bulk fluid temperatures are proprietary information.
The figure 11 plot of the measured suppression pool surface temperature is proprietary information.
The figure 12 plot of the preliminary measured PCC inlet flow rate is proprietary information.
l 4.0 TEST ANOMALIES and FAILED INSTRUMENTS There were no test anornalies or failed instruments
5.0 REFERENCES
- 1. GIRAFFE Helium Test Specification, General Electric Company Specification 25A5677, rev.1, May 1995
?--
1 00-3 1
0005 1T-EN EG SERU S
SER P
VAW dna VAD 1
-H T
SET I
ERUG IF W
GENE-T1500013-001 FIGURE 2 TEST H-1 NON-CONDENSABLE GAS VENT and LOCA VENT WATER LEVELS i
GENE-T1500013-001 FIGURE 3 TEST H-1 D/W TEMPERATURE 9
e e
GENE-TI500013-001 FIGURE 4 TEST H-1 PCC TUDE BULK FLUID TEMPERATURE e
4 e
GENE-T1500013-001 FIGURE 5A TEST H-1 SUPPRESSION POOL SURFACE TEMPERATURE I
l GENE-T1500013-001 FIGURE 5B DIFFERENTIAL PRESSURE MEASUREMENT LOCATIONS IN S/C j
l 7
GENE-T1500013-001 FIGURE 6 TEST H-1 PCC INLET FLOW RATE i
g,
1 00-3 1
0005 1
T-ENE G
SERU S
SER P
W
/W dna W
/D 2-H TSET 7
ERUG IF o
GENE-T1500013-001 FIGURE 8 TEST H-2 NON-CONDENSABLE GAS VENT and LOCA VENT WATER LEVELS
~