Text
o 3
SOUTH CAROLINA ELECTRIC & GAS COMPANY POSr OFFICE 784 ColuusiA. south CAnoLINA 29218
@ M,\\a 2.6 AME bl,1985
. o rO~.
wu
. D r. J. Nelson Grace d
, Regional Administrator U.S. Nuclear Regulatory Commission Suite 2900 101 Marietta Street. NW Atlanta, GA 30323
SUBJECT:
Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 I&E Bulletin 83-03
Dear'Dr. Grace:
South Carolina Electric and Gas Company (SCE&G) responded to IEB 83-03 on June 8, 1983.
It was noted in the response that two check valves (XVC-3119A and XVC-3119B) were found to be applicable and that the valves.would be tested by the end of the scheduled refueling outage.
Testing of the valves was performed on December 8, 1984, and verified to be acceptable.
I declare the statements and matters set forth herein are true and correct to the best of my knowledge, information, and belief.
Very truly-yours,
~.
O. W.
ixon, Jr.
L l
RJB:OWD/dwf cc:
V.
C.
Summer C.
L. Ligon (NSRC)
T.
C. Nichols, Jr./O. W.
Dixon, Jr.
K. E. Nodland E. H. Crews, Jr.
R.
A.
Stough E. C. Roberts G.
Percival W. A.
Williams, Jr.
C.
W. Hehl D. A.
Nauman J.
B.
Knotts, Jr.
Group Managers I&E Washington O. S. Bradham Document Management Branch C.
A.
Price NPCF S.
R.
Hunt File A
sO 8504160052 850321 PDR ALDCK 05000395 PDR 0
1