Part 21 & Interim Deficiency Rept Re Defective Parker-Hannifin Co Airline Check Valves in MSIV Actuators. Initially Reported on 850319.Valves Failing Initial Testing Will Be Inspected.Next Rept within 60 Days
ML20100D114
Person / Time
Site: Byron 
Issue date: 03/21/1985
From: Querio R
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
REF-PT21-85, REF-PT21-85-170-000 85-0426, 85-426, BYRON-85-426, PT21-85-170, PT21-85-170-000, NUDOCS 8504020310
Download: ML20100D114 (2)


Text

7

/

[

% Commonwealth Edison

'4 f Byron Nuct:ArSt tion i

\\

4450 North German Church Roid L.

Byron, Illinois 61010 March 21, 1985 LTR:

BYRON 85-0426

SUBJECT:

Notification of Possibly Defective Airline Check Valves in Byron Unit One (Docket Number 50-454) Main Steam Isolation Valve Actuators Mr. James G. Keppler Regional Administrator Region III U.S. Nuclear. Regulatory Conunission 799 Roosevelt Road Glen Ellyn, IL 60157

Dear Mr. Keppler:

This letter is to confirm our initial (3-19-85) notification cor.cerning possibly defective check valves within the air systems of our Main Steam Isolation Valve (MSIV) actuators (Anchor-Darling Co. Drawing Numbers 94-14060 and 94-14061). This report is submitted pursuant to 10CFR 21.21(b)(2).

On 3-14-85, two of Byron's Unit One Anchor-Darling Valve Co; double disc gate, Main Steam Isolation Valves failed to fully close upon receipt of a steamline isolation signal. This event occurred approximately 30-40 minutes af ter the Station Air / Instrument Air Compressor tripped during the loss of offsite power startup test. This loss of Instrument Air resulted in a slow depressurization of the air supply to the MSIV actuators. More information regarding this event will be supplied in License Event Report Number 85-027-00.

Subsequent investigation (documented on 3-18-85 by CECO Discrepancy Record Number 06-85-0106) showed that several of the MSIV actuator airline check valves failed to seat when subjected to a slow supply side pressure drop.

These check valves are manufactured by Parker-Hannifin Co. and supplied by Anchor-Darling Valve Co. (Anchor-Darling Co. Part Number W30261) as a basic component of the MSIV actuators.

In the event that instrument air supply pressure is lost, these check valves must seat in order to maintain the actuator's stored air charge which is necessary to achieve MSIV closure.

Working in conjunction with an Anchor-Darling Valve Co. Field Service Representative, the immediate corrective action taken after this discovery was to bench test the eight installed airline check valves along with eleven new check valves from Byron's spare parts inventory. Although all nineteen check valves successfully seated when subjected to a rapid supply side pressure drop, only eight seated when subjected to a slow depressurization. These eight have been installed on the Unit One MSIV actuators. These check valves are identified in Parker-Hannifin Co. literature as "Barstock Inline Check Valves, C Series, Catalog 2502".

A general description of the check valve is that it's a Barstok Inline Check Valve with soft elastomer poppet seal and a 5 psi cracking pressure.

8504020310 850321 MAR 2 51985 PDR ADOCK 05000454 S

PDR 0

IER

BYRON 85-0426 Followirg the installation of the bench tested check valves, each MSIV was subjected to a full stroke test. The test 1) isolated the instrument air supply, 2) initiated a slow depressurization of the air system between the supply isolation valve and airline check valves for one (1) hour, then 3) closed the valve. All four Main Steam Isolation Valves stroked fully closed in less than two seconds.

All four Unit One MSIV actuators will be retested following the 25% power, plant trip startup test, or one month from the previous test, whichever is sooner. Thereafter, they will be tested monthly until a permanent resolution is agreed upon. This testing will initiate a slow depressurization of the actuator air system between the check valves and supply valve and then verify seating of the airline check valves by either 1) MSIV closure, or 2) direct nonitoring of the MSIV actuators stored air charge pressure.

Plans are currently being made to have Commonwealth Edison's Operational Analysis Department inspect some of the check valves that failed the initial bench testing. These inspections should help determine what, if any, failure mode exists.

A followup meeting has been scheduled with representatives of Anchor-Darling Valve to review this event on March 25, 1985. As of this date, Commonwealth Edison knows of thirty-two (32) such airline check valves in use at Byron and Braidwood Stations (eight check valves per unit).

We recommend that utilities review the application of Parker-Hannifin check valves to determine if a slow, depressurization could prevent the safety actuator from performing its intended safety function.

A supplemental report will be provided within 60 days describing progress that has been made in our investigation of this event.

Sincerely, I

l l

R. E. Querio Station Superintendent Byron Nuclear Power Station REQ /CB/bg (0696Z) cc: Director, Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 (3 copies)

J. Hinds, NRC Resident Inspector i