ML20099K349

From kanterella
Jump to navigation Jump to search
Responds to Request for Addl Info Re Single Loop Operation. Info Provided by GE
ML20099K349
Person / Time
Site: Pilgrim, 05000000
Issue date: 05/06/1976
From: Andognini G
BOSTON EDISON CO.
To: Ziemann D
Office of Nuclear Reactor Regulation
Shared Package
ML20099K024 List:
References
FOIA-84-105
  1. 76-40, NUDOCS 8411290395
Download: ML20099K349 (2)


Text

k.jk.

u.e _a

~

.3 g

-~, _,

  • ~ ~.

' ~ ~

7 Q.,

l ROSTON EDISON COMPANY Ga.se.6 cmcas eco Savssvam stesse goston. MaseAcMuscTTs o2199 p

~,

'.D

/

May 6, 1976 g{

0[9 -

BECo. Ler. #76-40 Director of Nuclear Reactor Regulation 9

o.**

e

^

ATTN:

D. L. Ziemann, Chief Operating Reactors Branch #2 CO G

Division of Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D. C.

20555 Docket No. 50-293 License No. DPR-35 Additional Information on Single Loop Operation

Dear Sir:

In response to a verbal request from your staff we hereby submit the following infor=ation which has been provided by General Electric Company.

1.

Provide justification of the use of 0.10 second for single-loop boiling transition.

With regard to the decaying core flow after LOCA, the DBA pipe break in the single-operating recirculation loop is analogous to the DBA recirc-ulation break in a non-jet pump BWR.

In both cases the core flow decays rapidly which results in early boiling transition. For evaluation of the boiling transition time for non-jet pump plants the conservative cor-relation for no-flow conditions described in Section II.B of NEDE-20566 is used. Typically, the predicted boiling transition time is approximately 1.3 seconds. Since the core thermal-hydraulics are quite similar (i.e.,

rapidly decaying core flow after LOCA) immediately after the LOCA for both non-jet pump BWR's and jet pump BUR's with single loop operation the boiling transition time is essentially identical. Therefore, the assumption of boiling transition at 0.1 seconds for single loop operation ECCS analysis is conservative by a factor of approximately 10 for the single loop opera-I tion DBA.

2.

Justify that the single loop ECCS analysis is consistent with 10CFR50.46 and Appendix K.

I The ECCS analysis for single loop operation is performed using the accepted analytical models for Appendix K conformance calculations for jet pump BWR plants. The only exception is the assumption of boiling transition at 0.1 seconds. The justification of the conservatism of this assumption is ad-dressed in the response to Question #1.

MM 8411290395 840419 PDR FOIA BELL 84-105 PDR

-