ML20099D564

From kanterella
Jump to navigation Jump to search
Forwards ,Revised Pages to Rev 2 & Revised Pages 17,18 & 22 to Rev 1 to Emergency Plan.W/O Revised Pages to Rev 2
ML20099D564
Person / Time
Site: 05000294
Issue date: 02/20/1985
From: Wilkinson R
MICHIGAN STATE UNIV., EAST LANSING, MI
To: Thomas C
Office of Nuclear Reactor Regulation
Shared Package
ML20099D565 List:
References
NUDOCS 8503130388
Download: ML20099D564 (1)


Text

_

MICHIGAN STATE UNIVERSITY COLLFGE OF ENGINEERING

  • DIVISION OF ENGINI ERING RESEARCll EAST LAN5tNG
  • StlCitIGAN
  • 4M24 February 20, 1985 U.S. Nuclear Regulatory Commission Division of Licensing Washington, D.C.

20555 ATTENTION: Mr. Cecil 0. Thomas, Chief Standardization and Special Projects Branch

Subject:

Docket 50-294 Revision of Emergency Plan

Dear Mr. Thomas:

In accordance with your 2/7/85 letter requesting classification of the MSU Emergency Plan items. Attached to this letter, please find:

1.

Copy of May 21, 1984 letter transmitting Revision 1 of the Plan which responds to the telephone request of Mr. Bates on May 8, 1984.

2.

The revised pages for Revision 1, dated 5/9/84.

3.

The revised pages for Revision 2, dated 10/17/84.

The items identified in the " Emergency Plan Review dated January,1985 have, we believe been responded to in these revisions.

Specifically, the specific items are identified as:

Section 3.7 1.

Describe protective measures for emergency personnel. Please see Section 7.4.3, pp. 17-18, Section 7.6, p. 19, Section 3.4, p. 13 Section 8.3, pp. 19-20.

2.

Provide evacuation routes and primary and alternate assembly areas.

Please see Section 2.13, p. 8 and Section 7.4.3. pp. 17-18.

Section 3.10 1.

Provide for critiques of all drills, including timely evaluation of observer comments and corrections of identified deficiencies.

Please see Section 10.2, p. 22.

If additional information is needed, we will be happy to supply it.

l l

Sincerely.

8503130388 850220 1

R.E. Wilkinson PDR ADOCK 0500 4

l Assistant Vice President F

for Business & Finance

/

,4M 2 cc: MWM LI Document Control Desk U.S. NRC Washington, D.C.

20555 L

%25Uis an Nfirneasiew ActeenetEqualOttertunity lastetutio'e y

I