ML20099C170
| ML20099C170 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 04/08/2020 |
| From: | Michael Mahoney NRC/NRR/DORL/LPL2-1 |
| To: | Zaremba A Duke Energy Carolinas |
| References | |
| L-2020-LLS-0000 | |
| Download: ML20099C170 (3) | |
Text
From:
Mahoney, Michael Sent:
Wednesday, April 8, 2020 11:09 AM To:
Art Zaremba Cc:
Wasik, Christopher J
Subject:
Oconee Nuclear Station - Acceptance of Requested Licensing Action Re: MUR (L-2020-LLS-0000)
- Art, By letter RA-19-0144, dated February 19, 2020, as supplemented by letter dated April 6, 2020, Duke Energy submitted a license amendment request (LAR) for Oconee Nuclear Station, Units 1, 2, and 3 (Oconee). The proposed license amendment request (LAR) revises Technical Specifications (TSs) of Renewed Facility Operating License Nos. DPR-38, DPR-47 and DPR-55 (Oconee, Units 1, 2, and 3, respectively), to support a measurement uncertainty recapture (MUR) power uprate.
The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this LAR. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff has reviewed your application and supplement, and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.
Based on the information provided in your submittal, the NRC staff has estimated that this licensing request will take approximately 1,550 hours0.00637 days <br />0.153 hours <br />9.093915e-4 weeks <br />2.09275e-4 months <br /> to complete. The NRC staff expects to complete this review in approximately 9 months, which is December, 2020. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes in the forecasted hours, the reasons for the changes, along with the new estimates, will be communicated during the routine interactions with the assigned project manager.
These estimates are based on the NRC staffs initial review of the application and they could change, due to several factors including requests for additional information, unanticipated addition of scope to the review, and review by NRC advisory committees or hearing-related activities.
If you have any questions, please contact me.
Thanks Mike Michael Mahoney McGuire and Catawba Project Manager, Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission
Desk: (301)-415-3867 Email: Michael.Mahoney@NRC.GOV
Hearing Identifier:
NRR_DRMA Email Number:
516 Mail Envelope Properties (MN2PR09MB3517B04AB7EE9BC930093B39E5C00)
Subject:
Oconee Nuclear Station - Acceptance of Requested Licensing Action Re: MUR (L-2020-LLS-0000)
Sent Date:
4/8/2020 11:08:40 AM Received Date:
4/8/2020 11:08:41 AM From:
Mahoney, Michael Created By:
Michael.Mahoney@nrc.gov Recipients:
"Wasik, Christopher J" <Christopher.Wasik@duke-energy.com>
Tracking Status: None "Art Zaremba" <Arthur.Zaremba@duke-energy.com>
Tracking Status: None Post Office:
MN2PR09MB3517.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2980 4/8/2020 11:08:41 AM Options Priority:
Normal Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date: