t REVISED COPY OPERATING DATA REPORT DOCKET NO. 50-369 DATE 08-15-84 COMPLETED BY
.T a - naavis TELEPHONE 704-373-7567 i
OPERATING STATUS
- 1. Unit Name:
McGuire 1 Notes.
- Nameplate Rating
- 2. Reporting Period:.Tutv 1.
1gaa. int, 31, tggg (Gross MWe) calculated as
' 3. Licensed Thermat Power (MWt):
3411 1450.000 MVA x.90 power
~
- 4. Nameplate Rating (Gross MWe):
1305*
factor per Page 111, NUREG-0020.
1180
- 5. Design Electrical Rating (Net MWe):
- 6. Maximum Dependable Capacity (Gross MWe):
- 7. Maximum Dependable Capacity (Net MWe):
11R0
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:
None
- 9. Power Level To which Restricted. lf Any (Net MWe):
None
~
]
- 10. Reasons For Restrictions.If Any:
This Month Yr to.Date Cumulative I1. Hours in Reporting Period 744.0 5 111.0 23 375.0
- 12. Number Of Hours Reactor Was Critical 698.3 3 374.5 15 447.5
- 13. Resetor Reserve Shutdown Hours
- 14. Hours Generator On.Line 695.4 3 315.4 15 264.5
- 15. Unit Reserse Shutdown Hours
~Z-l
- 16. Gross Thermal Energy Generated (MWH)
.*2 320 680
- 10 694_430
- 38 131 499
. 17. Gross Electrical Energy Geaerated (MWH) 802 409 3 745 694 13 262 859
- 18. Net Electrical Energy Generated (MWH) 771 332 3 382 496 12 538 751
- 19. Unit Service Factor 93.5 64.9 65.3
- 20. Unit Availability Factor 93.5 64.9 65.3
- 21. Unit Capacity Factor (Using MDC Net) 87.9 59.4 U.3
- 22. Unit Capacity Factor (Using DER Net) 86.9 59.4 45.5 i
- 23. Unit Forced Outage Rate 6.5 4.7 17.6
- 24. Shutdowns Scheduled Over Next 6 Months (Type.Date and Duration of Eschi:
l None I
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
- 26. Units in Test Status t Prior to Commercial Operation):
Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
- Revised 9/15/84 (9/77) 8409260342 840914 PDR ADOCK 05000369 R
F S
a i
REVISED COPY OPERATING DATA REPORT DOCKET NO.
50-370 DATE 08-15-84
' CO>lPLETED BY J.A. Reavis TELEPHONE vnd-173-7567 OPERATING STATUS Notes
- Nameplate Rating
- 1. Unit Name:
McGrira 2 (Gross MWe) calculated as
- 2. Reporting Period:
July 1. 1984 - July 31. 1984 1450.000 MVA x.90 power
- 3. Licensed Thermal Power (5fWt):
3411 factor per Page lii,
- 4. Nameplate Rating (Gross 5fWe):
1305*
S. Design Electrical Rating (Net 31We): _ 1180
- 6. Staximum Dependable Capacity (Gross alWe):
1180
- 7. Staximum Dependable Capacity (Net alwe):
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report.Give Reasons:
- 9. Power Level To Which Restricted. If Any (Net alWe):
- 10. Reasons For Restrictions. If Any:
This alonth Yr to.Date Cumulative i
!!. Hours in Reporting Period 744.0 3 671.0 3 671.0
- 12. Number Of Hours Reactor Was Critical 44C 4 1 ?;A ?
1 95A 9
- 13. Reactor Reserve Shutdown Hours
~~~
~
- 14. Hours Generator On.Line 492.9 3 234.1 3 234.1
- 15. Unit Reserve Shutdown Hours
- 16. Gross Thermal Energy Generated (51WH)
- 1 558 247
- 10 680 976
- 10 680 976
.17. Gross Electrical Energy Generated (NIWH) 545 101 3 800 131 3 800 131
- 18. Net Electrical Energy Generated (31WH) 517 564 3 655 155 3 655 155 66.3 88.1 88.1
- 19. Unit Service Factor
- 20. Unit Availability Factor 66.3 88.1 88.1
- 21. Unit Capacity Factor (Using 31DC Net) 59.0 84.4 84.4 59.0 84.4 84.4
- 22. Unit Capacity Factor (Using DER Net)
- 23. Unit Forced Outage Rate 33.8 9.8 9.8
- 24. Shutdowns Scheduled Over Next 6 Stonths (Type. Date,and Duration of Each):
Refueline - January. 1985 - 8 weeks
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup: Aunust 20. 1984
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIA L CRITICALITY INITIAL ELECTRICITY Coil 5tERCIAL OPERATION I.
- Revised 9/15/84 (9/7 3 I
e
..-r...,
,,w,-
---mm.---,--..
- - - - -, -., _, ~,
,-_,--,__w wr..,.,.,y.-,
,.-,g
-