ML20098A019

From kanterella
Jump to navigation Jump to search
Third Interim Part 21 & Deficiency Rept Re Pipe Clamps Supplied by ITT-Grinnell.Initially Reported on 830406.Clamps Returned for Rework.Next Rept Expected by 841116
ML20098A019
Person / Time
Site: Bellefonte  
Issue date: 08/28/1984
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-84-445-000 PT21-84-445, PT21-84-445-000, NUDOCS 8409240223
Download: ML20098A019 (1)


Text

.

DRP TENNESSEE VALLEY AUTHORITY 3pFICIAL COP' CHATTANOOGA. TENNESSEE 374C1 400 Chestnut Street Tower II 84 AUG 30 Ppug28,1984 BLRD-50-438/83-30 BLRD-50-439/83-26 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator ~

101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - DEFECTS IN PIPE CLAMPS BY ITT:

GRINNELL - BLRD-50-438/83-30, BLRD-50-439/83 THIRD INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector Linda Watson on April 6,1983 in accordance with 10 CFR 50.55(e) as NCR 2318. This was followed by our interim report dated May 6,1983 i

Related NCR 2917 was later initiated and is now being reported on with NCR 2318. Our second interim report was submitted on May 24, 1983 Below is our third interim report. We expect to submit our next report by November 16, 1984. We consider 10 CFR Part 21 to be applicable to this deficiency.

1 TVA has scheduled a meeting with ITT-Grinnell at ITT-Grinnell's Warren, Ohio, facility to inspect the 64 four-inch clamps which TVA returned for rework. The intent of the meeting is to develop a consensus on the deficient condition and required corrective actions. TVA will document the results of this meeting in our next report.

If you have any questions, please get in touch with R. H. Shell at j

FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L.M. Mills,MNnager Nuclear Licensing cc:

Mr. Richard C. DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Comission Washington, D.C.

20555 Records Centar Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 i

8409240223 840828 g lo p 28, PDR ADOCK 05000438 jg S

PDR g

An Equal Opportunity Employer g