ML20097J988

From kanterella
Jump to navigation Jump to search
Fourth Interim Deficiency Rept Re Improper Use of Alternate Analysis Elbolets.Initially Reported on 821118.All Cases of Elbolets Qualified by Alternate Criteria Identified.Next Rept Expected by 841207
ML20097J988
Person / Time
Site: Bellefonte  
Issue date: 08/29/1984
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8409240151
Download: ML20097J988 (1)


Text

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II 84 AIJG 31 P l ; q 3 ugust 29,1984 A

BLRD-50-438/82-78 BLRD-50-439/82-72 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - IMPROPER USE OF ALTERNATE ANALYSIS ELBOLETS - BLRD-50-438/82-78, BLRD-50-439/82 FOURTH INTEFIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector P. E. Fredrickson on November 16, 1982 in accordance with 10 CFR 50.55(e) as NCR BLN BLP 8231. This was followed by our interim reports dated December 17, 1982 and March 22 and December 14, 1983 Below is our fourth interim report. We expect to submit our next report by December 7,1984.

TVA is still in the process of resolving the subject deficiency. All cases of elbolets being qualified by alternate criteria have been identified and new piping routes deleting the elbolets have been incorporated into revised drawings, but TVA is still determining the actions to prevent recurrence.

l If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TE ESSEE VALLEY AUTHORITY

[

L. M. Mills, Manager Nuclear Licensing oc:

Mr. Richard C. DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 MU 8409240151

$40$M PDR ADOCK 05000438 s

PDR g/ c 4 s

g g An Equal Opportunity Employer g y

.-