ML20097D152

From kanterella
Jump to navigation Jump to search
Notice of G Miller 840925 Deposition in Harrisburg,Pa Re Restart.Related Correspondence
ML20097D152
Person / Time
Site: Crane 
Issue date: 09/10/1984
From: Bernabei L, Doroshow J
GOVERNMENT ACCOUNTABILITY PROJECT, THREE MILE ISLAND ALERT
To:
Shared Package
ML20097D126 List:
References
SP, NUDOCS 8409170402
Download: ML20097D152 (1)


Text

-

DCLHETEr

: n ::,-

5 5

M@ gpg8k9:31 UNITED STATES OF AMERICA

- NUCLEAR REGULATORY COMMI:SION tri-t.-

00CMiyiGX h p j.,

cHANCH Before the. Atomic Safety and Licensing Board In the Matter of

)

)

METROPOLITAN EDISION COMPANY

)

Docket No. 50-289

)

(Restart-Management (Three Mile Island Nuclear

)

Phase) 4 Station, Unit 1)

)

NOTICE OF DEPOSITION OF GARY MILLER PLEASE TAKE NOTICE THAT intervenor TMIA will take the deposition of Gary Miller currently within GPU/ Met Ed's employ, on Tuesday, September 25, 1984, at the Friends Meeting House, 6th and Herr Streets (1100 6th St.), Harrisburg, PA, 17102.

Said deposition will begin at 9:30 a.m. and will continue thereafter until completed.

Respectfully submitted, EDN' C4tt A

/-

anne Doroshow 324 North-Capitol Street Washington, D.C.

20002 (202)-797-8106

.{M

2. 2_A t.v 1" Lynnq Bernabei Government Accountability Project 156

' ConnecticutAve.

N.W.

Wds)hington, D.C.

20036 (202) 232-8550 Dated: September 10, 1984 Attorneys for Three Mile Island Alert 8409170402 840911 PDR ADOCK 05000289 o

PM

,