Forwards Rev 5 to Response to NUREG-0588.Rev Incorporates New Parameters Due to Main Steam Line Break in Doghouse & Deletes Page EL40117H/6 & Page 7,Attachment 2 Re RCS Pressure Transmitters
ML20097C678
Person / Time
Site: Catawba  
Issue date: 09/12/1984
From: Tucker H
DUKE POWER CO.
To: Adensam E, Harold Denton
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0588, RTR-NUREG-588 NUDOCS 8409170203
Download: ML20097C678 (43)


Text

-_

s, g.

Dmm Powmt GOMPANY P.O. BOX 3318D

--s

[

)

CHARLOTTE, N.O. 28242 N._,/

IIAL II. TUCKER TELEPItONE

==commnen, (704) 373-4531 September 12, 1984

= = = = - - -

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention: Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: Catawba Nuclear Station Dr.Ket Nos. 50-413 and 50-414

Dear Mr. Denton:

Attached are five (5) copies of Revision 5 to Duke Power Company's response to NUREG-0588 for the Catawba Nuclear Station. This revision incorporates the following:

1.

New parameters in Attachment 3 due to a main steam line break in the Doghouse.

(~T 2.

Deletion of page EL40117H/6, response to NRC EQ Audit Items

- (,)

(Area Terminal Cabinet IEATC9A), as 1EATC9A component qualification is complete (page 60, Attachment 4).

3.

Deletion of page 7, Attachment 2, due to the RCS (WR) Pressure transmitters relocation to a mild environment.

Revision 5 pages should be inserted in accordance with the attached instructions.

Very truly yours, Y~b.

///g Hal B. Tucker ROS: sib Attachments h

P

%_ l M

memomea mom PDR ADOCK 05000413 P

PDR l

l

1

.Mr. HaroldL R. Denton, Director:

September 12, 1984 1

Page-Two I,)

~

cc:

(w/ attachment).

Mr. Tom.Humphry

-EG&G, Idaho

~

1520 Sawtrelle Street P. 0.. Box 1625

' Idaho Falls', Idaho 83401~

-(w/o attachments)

Mr. James P. '0'Reilly, Regional Administrator U!LS. Nuclear Regulatory Commission Region II

-101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 NRC Resident Inspector Catawba Nuclear Station Mr.-Robert Guild, Esq.

Attorney-at-Law P. O. Box 12097 Charleston, South Carolina. 29412 Palmetto Alliance Os 21351.Devine Street Columbia, South Carolina 29205 a.

Mr.-Jesse L. Riley Carolina Environmental. Study Group 1854 Henley Place Charlotte, North Carolina 28207 l.-

1-

~.... -

o..

. c

[

4 g ;.

IM Duke Power Company Catawba Nuclear Station Response to NUREG-0588 Revision 5 Instruction Sheet Remove These Pages Insert These Pages

'EL40117H/6-

.EL40117H/6 - L0EP - L0EP - L0EP - L0EP

- Page 6

- Page 6

- Page 32

- Page 32

- Page 33 Page 33 Page_34

- Page 34 Page 34a

- Page 36-

- Page 36

- Page 36a

- Page 40 Page 40 Page 40a

- Page 42

- Page 42

&)

Page 42a

(,

- Pa'ge 43

- Page 43

- Page 43a

- Page 44

-- Page 44 Page 44a

- Page 45'

- Page 45 Page 45a

- Page 46 Page 46 Page 46a

- Page 47

- - ~ Page 47 Page 47a

- Page 48-Page 48

- Page 48a

- Page 49

- Page 49

- Page 49a

- Page 50-

- Page 50

- Page 50a

.- Page 51-Page 41

- Page 52

- Page 52 Page 53

. Page 53

- Page 53a

- Page 54 Page 54

- Page 54a

- PRN-1 (Page 1)

PRN-1 (Page 1)

- PRN-1 (Page 2)

- PRN-1(Page2)

~ im - L0EP - L0EP

() -

- Page 60

- Page 60

=r W e'w

~

e e-c--,--cwe-w--*

--ieer+---9=--te-***v'-*-atetN-*e--v e-we s-w-

e - We w + r

  • e w+ w g - w v-w w 99m-e-* ee-m revem---+---

=*-*weTv-M-'-

4 i

4

{

Deleted by Revision 5 i

I i

f EL40117H/6

f r

fh ;

ATTACHMENT 2

SUMMARY

'0F ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT LOCATED IN THE ANNULUS Page_

Rev.

Page Rev.

Pace Rev.

. 1 3

. 2 --

4

.3 4~

~

4 D

5-

"4 6

0 7'

D 8

3 9

3

-10 3

11 3

-12 3

13-3-

- 14 3-15 3

16

. 3.

3

/c 18

-3 19

-1 20 3

21-

-3 22.

3 23-3 3 25 1

' 26-1~.

27 '-

2 AN-1.

3 AN-2

- 3

  • D - Deleted:

It has been determined that-this equipment is not in the scope of 10CFR50.49 due to plant / system design changes, relocation to a mild environment area, or review of function and failure I

mode with respect to the' event causing the harsh environment.

1 J-Revision 5 v

,w r,v.-,

-+oe---n---r-rN wn-,

-n

-w m,-,,

-,-,m--,-o.w-w w w,,,- orw?,,,,,-,,,-,,,,

m a

-,,--,--mww-e-w E ~ g g-

,g--

,-ws-m-w-e-py-we.-,-~

'(j f

ATTACHMENT 3

/

~

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT Page.

Rev.

Page Rev.

Page Rev.

1 2-35 4

63 2

2 D

36 5

64 1

3 4

36a 5

65 1

4

'4

-37 4

66 1

5 4

38 4

67 1

6 5.

39 0

68 1

7-4 40 5

69 1

8

.4 40a 5

70 1

9 4

41 D

71 1

10 3

42 5

72 1

11-J4-42a 5

73 1

12 D

43 5

74 1

13-

-4 43a 5

75 1

14 4

44 5

76 1

15 D

44a 5

77' D

16 0

45 5

78 D

'17 4

45a 5

79 1

_18 '

4 46 5'

PRN-1(Page1)5

-h.

19-

'4 46a 5

PRN-1(Page2)5 NJ 20-3' 47 5

21 3

47a 5~

22

4 48 5

23 4

48a 5

24~

4 49 5

25

'4 49a 5 1 50 5

27 4.

50a 5

28 D-51 5 '4 52 5

30

'4 53 5

31 D-53a 5

32 5

54-5 33 5-54a

-5 34 5

55 D

34a 5

56 4

57 2

58.

2 59 2

60 2

61 D

L 62 0

  • D - Deleted:

It-has:been. determined that this equipment is not in the scope D

of 10 CFR 50.59 due to plant / system design changes, relocation (h

to a mild environment area, or review of function and failure mode with respect to the event causing the harsh environment.

!r Rev. 5 7*

. - - + -

--y--

,-,c

..--,,-,.r.w--,--

ew rm,,--w.,,-

w e - t y wa w e,vwg ywam

- ' ~ - - ---=v-

--'- = + - -

--*,-*-y---wcerw-M

5 Q

U

- ~J m

CATAWDA NUCLEAR STATION - UNITS 1 AND~2.

SUMMARY

OF EllVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT-Page 6

.Rev. 5:

~

. LOCATED OUTSIDE CONTAlllMENT AND EXPOSED T0 PIPE RUPTURE.ENVIR0tlMENT EQUIPMENTID:

Transmitter-Mall 0FACTURER: Barton-

.MODEL #:

764 Aux. FW Flow (Doghouse) lj PIPE RUPTURE ENVIRONMENT CPERABILITY OPERABILITY

~ ACCURACY ACCURACY-EllVIRONMEllT TO WilICll REQUIRED Ill DEMONSTRATED ~

' REQUIRED

.DEM0tl51RA TED o i

'(1)-

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAH)'

ENVIRONMENT (2)

{.

i i

The Auxiliary Feedwater Flow transmitters are not' required to mitigate the consequences of a' main steam line break in the doghouse.

1 2

a j

QUALIFICATION REPORT:

N/A 1

(1ETil00:

N/A

^

{

REPLACEMENT INTERVAL:

N/A MPIC 1

i

y x,.

r%.

d w

k)l

~

~

,f N

CATAWBA NUCLEAR STATION

-UNITS'l AND 2

'Page 32 a:

SUMMARY

OF ENVIRONMENTAL: QUALIFICATION OF CLASS-1E EQUIPMENT

.Rev. 5'

~

LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT:

EQUIPMENT ID: Main Steam' Isolation

' MANUFACTURER:

Atwood and Morrill

'MODEL:#: 'MSI Valve Actuator-.

Valve (Doghouse).

Assembly PIPE RUPTURE

. ENVIRONMENT OPERABILITY OPERABILITY ACCURACY.

ACCURACY.

ENVIRONMENT TO WHICH

. REQUIRED-IN DEMONSTRATED REQUIRED-DEMONSTRATED..

(1)

-QUALIFIED-

' PIPE RUPTURE-(% OF SPAN)

(% OF SPAN)'

ENVIRONMENT (2)-

. Temp:

325 F*

Temp:

340 F 5.63 min.'

5.9 min.

N/A N/A-

~

Press:

8.85'psig Press:

110.psig RH: '100%-

RH:

100%.

  • 0oghouse environment at time safety. function completed _ Ref. CNC-1381.05-00-0156.

QUALIFICATION REPORT:

Procedure 201-39500, Test Report STR-060578-1 (CNM-1205.12-0009)

METHOD: Test

^

REPLACEMENT INTERVAL:

SLND & Elastomers.- 5 years MEQP

a

.- ~

m Y

CATAWBA NUCLEAR STATION.- UNITS 1.AND 2:

Page'33

SUMMARY

OF ENVIRONMENTAL. QUALIFICATION OF CLASSf1E EQUIPMENT'

.Rev. 51

' LOCATED OUTSIDE CONTAINMENT AND EXPOSED T0. PIPE RUPTURE ENVIRONMENT:

j EQUIPMENT.ID:

Feedwater ' Isolation.

MANUFACTURER:

Borg-Warner (NVD)'

.MODEL #:. Pneumatic-Hydraulic-

~

l

. Valve (Doghouse)

Operator'P/N.38991 i

I PIPE RUPTURE.

ENVIRONMENT = '

OPERABILITY:

OPERABILITY ACCURACY ACCURACY j

ENVIRONMENT TO WHICH

REQUIRED'IN DEMONSTRATED-REQUIRED DEMONSTRATED

-(1)

QUALIFIED

. PIPE RUPTURE.'

~(% OF SPAN)"

(% OF SPAN) j

. ENVIRONMENT (2) i Temp:

300 F*

. Temp:

340 F' 2.57 min.

5.9 min.

N/A

-N/A Press: 8.85 psig Press:'

110 psig RH:

100%

Ril:

100%.

i i

l

'?

j

  • Doghouse environment at time safety function. completed - Ref. CNC-1381.05-00-0156.

1 i

i i

j. QUALIFICATION REPORT:

1736 (CNM-1205.12-0014) r 1

METHOD:

Test 1

i I

j. REPLACEMENT INTERVAL: N/A MEQP.

I i

l 5

.]

r

~*

~

CATAWBA NUCLEAR. STATION - UNITS'1'AND'2 Page 34

SUMMARY

OF ENVIRONMENTAL'QllALIFICATION OF CLAS3 1E EQUIPMENT-LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT

- Rev. 5-

. EQUIPMENT ID:

Valve Motor Operators MANUFACTURER:

Limitorque MODEL #:

SMB RH' Insulation (Doghouse).

PIPE RUPTURE ENVIRONMENT' OPERABILITY OPERABILITY ACCURACY.

ACCURACY ENVIRONMEllT TO WHICH REQUIRED IN-DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

~ ENVIRONMENT (2) i The Limitorque Valve Motor Operators located in the Doghouse are not required for mitigation of the consequences of j

a MSLB in the Doghouse.

I l

i 1

i i

}

QUALIFICATION REPORT:

N/A 1

i METHOD:

i i

REPLACEMENT INTERVAL:

N/A MEQP d

4 CATAWBA NUCLEAR STATION - UNITS 1 AND 2.

Page 34a-

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Rev.,5 -

LOCATED-OUTSIDE CONTAINMENT.AND EXPOSED TO PIPE P.UPTURE ENVIRONMENT i

j LEQUIPMENT ID:

Valve Motor Operators-MANUFACTURER: :Limitorque

.MODEL #:

SMB RH' Insulation L

i i

4 PIPE' RUPTURE ENVIRONMENT OPERABILITY-OPERABILITY ACCURACY

' ACCURACY

-ENVIRONMENT TO VHICH REQUIRED IN'.

DEMONSTRATED REQUIRED ^

-DEMONSTRATED..

i (1)

, QUALIFIED PIPE RUPTURE

. % OF SPAN)

(% OF SPAN)'

(

i ENVIRONMENT (2);

l Temp:

262 F.

Temp:

340 F-Continuous Continuous N/A

'N/A

)

'RH:

100%

RH:

100%

i L

{

QUALIFICATION REPORT:

600-376-A, September 1972; 600-456,. December 1975 (CNM-1205.19-0001) i METHOD:

Test REPLACEMENT INTERVAL:

N/A MEQP 1

j

~

i

O v

v N-CATAWBA. NUCLEAR STATION - UNITS 1 AND 2 Page.36,

SUMMARY

OF ENVIRONMENIAL QUALIFICATION OF CLASS 1E EQUIPMENT Rev. 57

. LOCATED OUTSIDE CONTAINMENT AND EXPOSED T0 PIPE RUPTURE ENVIRONMENT EQUIPMENT.ID:

Valve Motor' Operators MANUFACTURER:

Rotork.

~MODEL #:

NA (Doghouse) i PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY

' ACCURACY-ACCURACY-ENVIRONMENT TO WHICH.

REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED 2

(1)

QUALIFIED PIPE RUPTURE.

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2)

Temp:

300 F*

Temp:.340 F

!3.77 min.

5.9 min.

N/A-

-N/A i

Press:

8.85 psig Press:

70 psig l

RH:

100%

RH:

100%

l

  • Doghouse environment at time safety function completed - Ref. CNC-1381.05-00-0156.

l I'

QUALIFICATION REPORT:

N 11/4, December 1970; TR116, October 1973; TR222, June 1975 (CNM-1205.19) r

]

METHOD:

Test

,i REPLACEMENT -INTERVAL:

N/A MEQP.

i a

4 i

CATAWBA NUCLEAR STATION - UNITS 1 ANDj2~

Page 36a

~

SUMMARY

OF ENVIRONMENTAL' QUALIFICATION OF CLASS 1E EQUIPMENT.-..

LOCATED OUTSIDE CONTAINMENT AND EXPOSED T0 PIPE RUPTURE ENVIRONMENT.

Rev.' 5 :

". EQUIPMENT ID:. Valve-Motor Operators'.

MANUFACTURER:

Rotork MODEL #:

NA-1

. PIPE RUPTURE ENVIRONMENT

' OPERABILITY OPERABILITY-ACCURACY ACCURACY-

' ENVIRONMENT' TO WHICH-REQUIRED IN~

DEMONSTRATED-

-REQUIRED:.

-DEMONSTRATED.

(1)

QUALIFIED

-PIPE RUPTURE

'(% OF SPAN)-

(% OF_ SPAN)<

ENVIRONMENT (2)-

~

Temp:

262 F Temp:

340*F Continuous Continuous N/A N/A-RH:

100%

Ril:

100%-

f QUALIFICATION REPORT:

N 11/4,. December 1970; TR116, October 1973; TR222,. June 1975 (CNM-1205.19)

METHOD:

Test REPLACEMENT INTERVAL:

N/A MEQP

._ _ m - --~

--m

-- ~ - *' ~ ~ ~ ' " ~ ~

' ' ~

[. t

'l u

[

,g; 3

V r

Y a

[

7 4

CATAWBANUCLEARSTATION-UNITSILANd2' Page 40

~,

SUMMARY

.0F' ENVIRONMENTAL QUALIFICATION OF. CLASS 1E EQUIPMENT.

Rev.-S' l.
LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE 1 RUPTURE'ENVIRONMENTE I

e EQUIPMENT ID:

Valve Solenoid Operators-MANUFACTURER:.Valcor-

MODEL'#:. V70900-21~3:

[

(Doghouse);

l i,

}

' PIPE RUPTURE'

. ENVIRONMENT.

OPERABILITY' 0PERABILITY ACCURACY.

-ACCURACY l

' ENVIRONMENT

-T0 WHICH cREQUIRED IN DEMONSTRATED REQUIRED.

DEMONSTRATED..

(1) l QUALIFIED-

' PIPE RUPTURF.

(% OF' SPAN)

-(% OF. SPAN):

}'

" ENVIRONMENT (2):

i t

1 j

Temp:

300 F*-

Temp: 346*F

2.57' min.

6.0 min.

N/A

- N/A Press': 8.85 psig Press:

87.psig'

.RH:

100%

RH:

100%~

l l

i.

i

  • Doghouse environment at time. safety function completed - Ref. CNC-1381.05-00-0156.

'i i

j

QUALIFIC TION REPORT
-QR-70900-21-1 Rev. A;-QR-52600-515 Rev. 8, MR-70905-21-3-1-(CNM-1210.04-253 254 & MCM-1210.04-11

. i 1

}

i L

e i

.: METHOD:

Test / Analysis I

l REPLACEMENT INTERVAL:' 5 Years -

EMPIC.

1 i

i 3

i f

+-

y-py f

r

%) -

-(

\\

t x

T.

.~

i I

' CATAWBA NUCLEAR STATION - UNITS 1=AND 2 1Page 40a L

SUMMARY

OF ENVIRONMENTAL' QUALIFICATION OF. CLASS 1EiEQUIPMENTt

.Rev.: 5 -

t.

LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO' PIPE: RUPTURE ENVIRONMENT EQUIPMENT ID:

Valve Solenoid Operators:

' MANUFACTURER:'

Valcor'

'MODEL #:

V70900-21-3

~

3 PIPE RUPTURE ENVIRONMENT.

OPERABILITY OPERABILITY' ACCURACY-ACCURACY.

l ENVIRONMENT

'T0:WHICH REQUIRED IN' DEMONSTRATED REQUIRED:

. DEMONSTRATED.

l (1)

QUALIFIED.

PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)-

1-ENVIRONMENT (2)

I

. Temp:

262 F Tempi 346 F' C'ontinuous Continuous

~N/A N/A j

Ril:.100%

Ril:

100%

1 i

l 1

}

QUALIFICATION REPORT: QR-70900-21-1 Rev. A;-QR-52600-515 Rev. B, MR-70905-21-3-1 (CNM-1210.04-253 254 & MCM-1210.04-119) 1 METil0D:

Test / Analysis'

.3 b.

!.REPLACEMENTINTERVAL:

5 Years l

MPIC I

i

.m.

. -~

pgl -

y -,

h s.

O l(u );

.-y st CATAWBA NUCLEAR STATION.- UNITS 1-AND 2-

.Page 42.

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E. EQUIPMENT.

' LOCATED OUTSIDE: CONTAINMENT AND-EXPOSED TO PIPE' RUPTURE ENVIRONMENT:

Rev..St JEQUIPMENT:ID:. Cable -

MANUFACTURER: Anaconda:

MODEL #: -FR-EPR

' Hookup Wire

-Insulation.(Procurement" (Doghouse)

-Spec:

CNS-1354.04-00-0006)'

' PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY-ACCURACY ~

ACCURACY ENVIRONMENT TO WHICH.

REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

~ QUALIFIED PIPE RUPTURE

'(% OF SPAN)

.(% OF. SPAN)

ENVIRONMENT (2)

Temp:

325 F*

. Temp:

385 F-5.63 min.

7.2 min.

N/A N/A Press:

8.85 psig Press:

66 psig RH:

100%

RH:

100%

  • Doghouse environment at time safety function completed - Ref. CNC-1381.05-00-0156.

QUALIFICATION REPORT:

80205-1 (CNM-1354.0'0-0019)

METHOD:

Test / Analysis

' REPLACEMENT INTERVAL:

N/A EPSS-

,i_

?

CATAWBA NUCLEAR. STATION:. UNITS'1 AND 2:

.Page 42a:

SUMMARY

OF' ENVIRONMENTAL QUALIFICATION OF. CLASS 1E-EQUIPMENT

'Rev.5~

LOCATED 0*JTSIDE CONTAINMENT AND EXPOSED ~n) PIPE RUPTURE ENVIRONMENT EQUIPMENT IDi Cable -'

MANUFACTURER:

Anaconda

.MODEL #:

FR-EPR-Hookup Wire Insulation:(Procurement Spec:

CNS-1354.04-00-0006) i PIPE RUPTURE ENVIRONMENT ~

OPERABILITY-OPERABILITY ACCURACY ACCURACY.

ENVIRONMENT TO WHICH REQUIRED IN DEMONSTRATED REQUIRED-DEMONSTRATED (1)

-QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

]

-ENVIRONMENT (2).

1 l-Temp:

252 F Temp:

385 F-Continuous Continuous N/A N/A RH:

100%

RH:

100%

I i

i H

QUALIFICATION REPORT:

80205-1 (CNM-1354.00-0019) p 4

METil0D:

Test / Analysis j

REPLACEMENT INTERVAL:

N/A EPSS I

(-.

f~

Q)

, ~)~

v CATAWBA NUCLEAR STATION - UNITS 1 AND 2.

Page 43'

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT

.Rev._5 LOCATED OUTSIDE CONTAINMENT AND EXPOSED.T0 PIPE RUPTURE. ENVIRONMENT EQUIPMENT ID:

Cable -

-MANUFACTURER: Anaconda MODEL #:

EPR Medium Voltage Power

' Insulation (Procurement' (Doghouse)

. Specs:

CNS-1354. 01-00-000F

& 0003)'

PIPE RUPTURE ENVIRONMENT-OPERABILITY OPERABILITY ACCURACY ACCURACY ENVIRONMENT TO WHICH REQUIRED IN DEMONSTRATED

. REQUIRED DEMONSTRATED (1)

QUALIFIED-

. PIPE RUPTURE

-(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2)-

-Temp:

325 F*

Temp: ~346 F

5.63 min.-

6.0 min.

N/A N/A Press:

8.85 psig Press:

113'psig RH:

100%

RH:

100%-

  • Doghouse environment at time safety function completed - Ref. CNC-1381.05-00-0156.

QUALIFICATION REPORT:

80205-1 (CNM-1354.00-0019)

METHOD:

Test / Analysis REPLACEMENT' INTERVAL:

N/A EPSS

..y.7 O

Cr O

r.

. ' CATAWBA NUCLEAR STATION - UNITS l'AND 2 Page'43a

~

SUMMARY

. 0F ENVIRONMENTAL-QUALIFICATION OF. CLASS '1E EQUIPMENT Rev.5L LOCATED OUTSIDE CONTAINMENT AND EXPOSED T0 PIPE RUPTURE ENVIRONMENT:

EQUIPMENT ID:

Cable -

MANUFACTURER:

Anaconda MODEL #:

EPR Medium Voltage Power

. Insulation (Procurement-

. Specs: JCNS-1354.01-00-000]

& 0003)

PIPE RUPTURE-

. ENVIRONMENT OPERABILITY OPERABILITY-ACCURACY ACCURACY-ENVIRONMENT TO WHICH.

. REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED:

-(1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2).

Temp:

262 F Temp:

346 F Continuous Continuous N/A N/A Rit:

100%

Ril:

100%

QUALIFICATION REPORT:

80205-1 (CNM-1354.00-0019)-

4 METi100:

Test / Analysis REPLACEMENT INTERVAL:

N/A EPSS

., - ~ - - _,-

j.

1 a.

CATAWBA: NUCLEAR STATION - UNITS 1 AND 2 Page;44-

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS'IE EQUIPMENT l.

Rev. 5 -

LOCATED OUTSIDE' CONTAINMENT AND EXPOSED T0 PIPE RUPTURE ENVIRONMENT:

4 1 EQUIPMENT'ID:. Cable -

MANUFhCTURER:Anaconda

'MODEL'#:

FR-EPRs

~"

Control.

Insulation'(Procurement (Doghouse)

Specs:

CNS-1354.02-00-0001 1

&.0002) i PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY;

. ACCURACY ACCURACY.'

j ENVIRONMENT TO WHICH REQUIRED IN DEMONSTRATED:

REQUIRED

. DEMONSTRATED'-

(1)

-QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2).

Temp:

325 F*

Temp:

385*F-5.63 min.

7.2 min.-

N/A N/A l

Press:

8.85 psig Press:

113 psig-RH:

100%

RH:

100%

i i

l

  • Doghouse environment at time safety function completed - Ref. CNC-1381.'05-00-0156.

l

-l 1

l QUALIFICATION REPORT:

80205-1 (CNM-1354.00-0019) l 1

1 METHOD:' Test / Analysis-i 1

l

~ REPLACEMENT INTERVAL:

N/A EPSS' l

i

_ (-~

,~

/

I CATAWBA NUCLEAR STATION - UNITS 1 AND 2 Page 44a

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS IE EQUIPMENT Rev. 5 LOCATED OUTSIDE CONTAIllMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT EQUIPMENT ID:

Cable -

MANUFACTURER:

Anaconda MODEL #:

FR-EPR Control Insulation (Procurement Specs:

CNS-1354.02-00-0001

& 0002)

PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY ACCURACY Et4VIRONMENT TO WillCli REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFILD PIPE RUPTURE

(% OF SPAN)

(% OF SPAtl)

ENVIRONMENT (2)

Temp:

262 F Temp:

385 F Continuous Continuous N/A N/A Ril:

100%

Ril:

100%

QUALIFICATION REPORT:

80205-1 (CilM-1354.00-0019)

METil0D:

Test / Analysis REPLACEMENT INTERVAL:

N/A EPSS

.~.

~ -

7 d

4-CATAWBA NUCLEAR STATION - UNITS 1 AND 2 Page '45

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS-IE EQUIPMENT.-

.Rev. 5' LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT

. EQUIPMENT ID:

Cable -

MANUFACTURER: Anaconda MODEL #: - FR-EPR

-Instrumentation and Control-

~(Doghouse)

Insulation (Procurement' Specs:

CNS-1354.03-00-0001 0002 & 0003) i PIPE RUPTURE -

ENVIRONMENT OPERABILITY..

OPERABILITY ACCURACY-ACCURACY' ENVIRONMENT TO WilICH

-REQUIRED IN.

DEMONSTRATED REQUIRED-DEMONSTRATED.

{

(1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN) l ENVIRONMENT (2) l 1

.i Temp:

325 F*

Temp:

385 F

'5.63 min.

7.2 min.

N/A N/A 1

Press: 8.85 psig Press:

66 psig Ril:

100%

Ril:

100%

9 l

  • Doghouse environment at time safety function completed - Ref. CNC-1381.05-00-0156.

l I

j QUALIFICATION REPORT:

F-C4836-2 (CNM-1354.00-0020)

)

HETil00: Test / Analysis i

l REPLACEMENT INTERVAL:

N/A EPSS

/

~

y

[]'

W s'~

,' Q )J ~

.s

.*r r

f 4'

i-a 7

CATAWBA NUCLEAR [ STATION'- UNITSl AND 2' Page 45a

' SUPMARY. OF ENVIRONMENTAL QUALIFICATION OF CLASS.1E EQUIPMENTi

- Rev. 5

+

4.

LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ~ ENVIRONMENT:

EQUIPMENT.ID:

Cable ~'-

MANUFACTURER: Anaconda

.MODEL #:

FR-EPR'.

-Instrumentation and Control InsulationL(Procurementt '

l Specs:..CNS-1354.03-00-000]:

.0002 & 0003)'

l i

l PIPE RUPTURE ENVIRONMENT

-0PERABILITY-OPERABILITY ACCURACY ACCURACY-i ENVIRONMENT TO WHICH.

' REQUIRED IN:

DEMONSTRATED REQUIRED DEMONSTRATED-

{

(1)

' QUALIFIED PIPE RUPTURE:

(% OF SPAN)

(% 0F SPAN)

. ~

' ENVIRONMENT (2) i Temp:

262 F

. Temp:

385*F-Continuous Continuous N/A-N/A

}

RH:' 100%'

RH: 100%

i i

j

)

QUALIFICATION REPORT:

F-C4836-2 (CNM-1354.00-0020)

(

i METHOD:

Test / Analysis i

i i.

REPLACEMENT INTERVAL: N/A

?

EPSS i

6 a

et

~ ~ ~

m.

3 f,,*~

4

~

CATAWBA: NUCLEAR STATION - UNITS:1 AND~2 Page 46 SUF9tARY-0F ENVIRONMENTAL' QUALIFICATION OF CLASS IE.~ EQUIPMENT-Rev.;5 LOCATED OUTSIDE' CONTAINMENT: AND EXPOSED.T0. PIPE RUPTURE ENVIRONMENT 3

j

. EQUIPMENT.ID:

Cable -'

MANUFACTURER:

Anaconda

.-MODEl. #:.

FR-EPR:

Low Voltage Power-j (Doghouse)

-:InsulationE(Procurement.

Specs:. CNS-1354.'01-00-000]

& 0003) i b

PIPE RUPTURE-

. ENVIRONMENT OPERABILITY.-

OPERABILITY ACCURACY ACCURACY ENVIRONMENT TO WHICH.

REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1).

QUALIFIED PIPE ~ RUPTURE'

(% OF SPAN)

(% OF. SPAN)~

ENVIRONMENT (2)-

i l

. Temp:

325 F*

Temp:

385*F' 5.63 min.

7.2 min.

N/A

,N/A-Press:

8.85 psig Press:

113 psig RH:

100%

RH:

100%

I I

1

  • Doghouse environment at time safety function completed.- Ref. CNC-1381.05-00-0156.

t QUALIFICATION REPORT:

80205-1 (CNM-1354.00-0019) a i

HETH00:

Test l

{

REPLACEMENT INTERVAL:

N/A'.

3 EPSS I

4

i-.

y

~

f):

l-

~

v.

p --
s.. -

'l

.g CATAWBA NUCLEAR STATION - UNITS 1 AND 2.

.Page 46a

~

SUMMARY

'0F ENVIRONMENTAL. QUALIFICATION OF CLASS 1E EQUIPMENT-Rev. 5 LOCATED OUb1DE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT EQUIPMENT ID:

Cable' -

MANUFACTURER:. Anaconda MODEL #:

FR-EPR.

-Low Voltage Power

-Insulation.(Procurement Specs:

CNS-1354.01-00-0001

& 0003)

~

t PIPE RUPTURE ENVIRONMENT ~

OPERABILITY OPERABILITY ACCURACY ACCURACY ENVIRONMENT T0.WHICil REQUIRED IN Deft 0NSTRATED REQUIRED

. DEMONSTRATED (1)

QUALIFIED-PIPE RUPTURE

(% OF SPAN)~

.(% OF SPAN)

ENVIRONMENT (2) l Temp:

262 F Ter.

?% T Continuous-Continuous N/A N/A

-l RH:

100%

RH-x QUALIFICATION REPORT:

80205-1 (CNM-1354.00-0019)

METHOD:

Test REPLACEMENT INTERVAL:

N/A EPSS

y.

[-(-

Y j-s

.QJ Ag y.

' CATAWBA NUCLEAR STATION - UNITS 1 AND 2..

.Page 47' s

SUMMARY

OF. ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Rev.LS-

' LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTU E ENVIRONMENT.

r R

. EQUIPMENT ID:

Cable -

MANUFACTURER: ' Brand-Rex.

MODEL #:

XLPE Control Insulation ~(Procurement (Doghouse)

Specs:

CNS 1354.02-00-000]

& 0002) 4 d

l PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY ACCURACY

't ENVIRONMENT TO WHICH' REQUIRED IN DEMONSTRATED

. REQUIRED l DEMONSTRATED j

(1)

QUALIFIED. ',

PIPE RUPTURE

.(% OF SPAN)

(% OF SPAN)

-ENVIRONMENT (2) t.

s Temp:

325 F*

Temp:

385 F.

.5.63 min.

7.2 min.

N/A N/A Press:

8.85 psig Press:

113 psig RH:

100%

RH:

100%

)

j I

  • Doghouse environment at time safety function completid Ref. CNC-1381.'05-00-0156.

I i

QUALIFICATION REPORT:

FC-5120-1 and FC-5120-3 (CNM-1354.00-0023) and CNM-1354.00-0024

~

l METHOD:

Test REPLACEMENT INTERVAL:

N/A EPSS 1

i ij

k]

L [f,"

,n,

.r.;

p CATAWBA NUCLEAR STATION. UNITS 1 AND 2 Page 47a.

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS IE EQUIPMENT Rev. ' 5 LOCATED OUTSIDE CONTAINMENT AND EXPOSED T0-PIPE. RUPTURE ENVIRONMENT EQUIPMENT ID:

Cable'-

MANUFACTURER:

Brand-Rex MODEL #:

XLPE Control Insulation (Procurement-Specs:

CNS-1354.02-00-000]

& 0002)

PIPE RUPTURE ENVIR0iG1ENT OPERABILITY OPERABILITY-ACCURACY ACCURACY ENVIRONMENT TO WHICH

-REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED

. PIPE RUPTURE

(% 0F SPAN)

(% OF SPAN)

ENVIRONMEiT(2)

Temp:

262 F Temp:

385 F Continuous Continuous N/A N/A RH:

100%

RH:

100%

QUALIFICATION REPORT:

FC-5120-1 and FC-5120-3 (CNM-1354.00-0023) and CNM-1354.00-0024 METHOD:

Test REPLACE!1ENT INTERVAL:

N/A-EPSS

.-...r-e g" g g

. -o w. '

4 C

-CATAWBA NUCLEAR STATION - UNITS 1 AND 2.

.Pagel48

SUMMARY

.'0F: ENVIRONMENTAL' QUALIFICATION 0F CLASS 1E EQUIPMENT-Rev.'5:

LOCATED OUTSIDE CONTAINMENT: AND EXPOSED.T0 PI:PE-RUPTURE ENVIRONMENT:

,L EQUIPMENT ID: - Cable -

MANUFACTURER: -Breed-Rex MODEL #:

XLPE a

Coaxial-Insulation (Procurement (Doghouse)

Spec:

CNS-1354.04-00-0004) s

. PIPE RUPTURE-ENVIRONMENT OPERABILITY' OPERABILITY

. ACCURACY ACCURACY ENVIRONMENT TO WHICH

. REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED.

-(1)

QUALIFIED PIPE RUPTURE

(% OF-SPAN)

(% OF SPAN)

ENVIRONMENT (2)

Temp:

325 F*

Temp:

385*F 5.63 min.

7.2 min.

N/A-N/A:

Press: 8.85 psig

. Press:

113 psig RH:

100%

RH:

100%

4

  • Doghouse environment.at time safety function completed - Ref. CNC-1381.05-00-0156.

QUALIFICATION REPORT:

FC-5120-2 and FC-5120-3 (CNM-1354.00-0021 and CNM-1354.00'-0024) e METHOD:

Test REPLACEMENT INTERVAL: N/A EPSS

gp fx f')

. ('~'y Q

q 1-q) t CATAWBA NUCLEAR STATION;- UNITS 1 AND 2 Page 48a

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT

Rev. 5 :

LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT EQUIPMENT ID:

Cable -

MANUFACTURER:

Brand-Rex

'MODEL #:

XLPE' Coaxial Insulation (Procurement Spec:

CNS-1354.04-00-0004)-

4 PIPE RUPTURE ENVIRONMENT

~ ENVIRONMENT-OPERABILITY OPERABILITY ACCURACY ACCURACY TO WHICH REQUIRED IN -

DEMONSTRATED.

REQUIRED-DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2)

Temp:

262 F Temp:

385 F Continuous Continuous N/A N/A Ril:

100%

RH:

100%

4 QUALIFICATION REPORT:

FC-5120-2 and FC-5120-3 (CNM-1354.00-0021 and CNM-1354.00-0024) itETH00: Test REPLACEMENT INTERVAL:

N/A EPSS

d

~

V

-(u

()

,e,

CATAWBA NUCLEAR STATION - UNITS 1 AND 2' Page '49

SUMMARY

OF ENVIRONMENTAL' QUALIFICATION OF CLASS 1E EQUIPMENT LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT..

Rev. 5' EQUIPMENT ID:

Cable -

.MANUFACTURERi Eaton.

_MODEL #:

FR-EPDM Instrumentation and Control Insulation (Procurement Specs:

(Doghouse)

CNS-1354.03-00-0001,.0002 & 0003 PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY-ACCURACY ENVIRONMENT TO.WHICH REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED

. PIPE RUPTURE-(% OF SPAN)

(% OF SPAN) j

. ENVIRONMENT (2) 4 Temp:

325 F*

Temp:

430 F ~

5.63 min.

7.4 min.

N/A N/A Press: 8.85 psig Press:

15 psig j

RH:

100%

RH:

100%

4

)

  • Doghouse environment at time safety function completed - Ref. CNC-1381.05-00-0156.

~

i j

QUALIFICATION REPORT:

Qualification test of electrical cables by Isomedix (CNM-1354.00-0035).

4 V

l' METHOD: Test / Analysis 1

j REPLACEMENT INTERVAL:

N/A EPSS i

l

=

'O

I, n.

k

^..

\\s}

(

]-

CATAWBA NUCLEAR. STATION - UNITS ~1 AND"2-Page 49a

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT'.

Rev. 5 LOCATED OUTSIDE CONTAINMENT AND' EXPOSED.T0 PIPE RUPTURE-ENVIRONMENT EQUIPMENT ID:

Cable -

MANUFACTURER:

Eaton MODEL #:

FR-EPDM.

Instrumentation and Control Insulation (Proc'urement Specs:

CNS-1354.03-00-0001;'0002 & 0003 PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY ACCURACY ENVIRONMENT TO WHICH REQUIRED IN' DEMONSTRATED.

REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)-

. (% OF SPAN)-

ENVIRONMENT (2)

Temp

262 F Temp:

430 F.

Continuous Continuous N/A N/A RH: '100%

RH:

100%

QUALIFICATION REPORT:

Qualification test of electrical cables by Isomedix (CNM-1354.00-0035).

~

3 METHOD:

Test / Analysis REPLACEMENT INTERVAL:

N/A EPSS

.py fM (Ml

.' (

A L.

CATAWBA NUCLEAR STATION,- UNITS 1 AND 2 Page.50-

SUMMARY

0F ENVIRONMENTAL. QUALIFICATION OF CLASS 11E EQUIPMENT.

LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENTi.

Rev.::5' EQUIPMENT 10:

Cable -

MANUFACTURER: Okonite.

MODEL #:

EPR.

1 Medium Voltage

. Insulation (Procurement (Doghouse)

Specs:

CNS-1354.01-00-000:

& 0003)

PIPE RUPTURE ENVIRONMENT OPERABILITY

.0PERABILITY ACCURACY ACCURACY' ENVIRONMENT TO WilICH

. REQUIRED IN DEMONSTRATED

-REQUIRED DEMONSTRATEDL (1)

QUALIFIED

-PIPE P.UPTURE

(% OF SPAN)

-(% OF SPAN)

ENVIRONMENT (2)

. Temp:

440 F Temp:

455 F Contin ~uous Continuous' N/A N/A Press:

8.85 psig Press:.32 psig RH:

100%

RH:

100%

QUALIFICATION REPORT:

Okonite Report #355 (CNM-1354.00-0022)

METHOD:

Test REPLACEMENTINTERVA[.: N/A EPSS

(.. s~%.)I "

4);

CATAWBA NUCLEAR STATION - UNITS-1 AND 2

Page.50a

SUMMARY

OF ENVIRONMENTAL-QUALIFICATION OF CLASS 1E EQUIPMENT ~

.Rev.5

. LOCATED OUTSIDE CONTAINMENT AND EXPOSED T0' PIPE RUPTURE ENVIRONMENT.

EQUIPMENT ID:

Cable -

MANUFACTURER:

Okonite MODEL'#:

EPR..

Medium Voltage

. Insulation (Procurement-Specs:

CNS-1354.01-00,0001

& 0003)

PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY ACCURACY ENVIR0flMENT T0 WHICH REQUIRED IN:

DEMONSTRATED REQUIRED DEMONSTRATED..

(1)-

QUALIFIED PIPE RUPTURE

(% OF SPAN)'

(% OF SPAN)

ENVIRONMENT (2)

Temp:

262 F Temp: 455 F Continuous Continuous N/A' N/A-RH:

100%

RH:

100%

QUALIFICATION REPORT:

Okonite Report #355 (CNM-1354.00-0022) e

!!ETHOD: Test REPLACEMENT INTERVAL:

N/A.

EPSS

,m 7y f~'y

/

()

L/ ' >

f.-.

.i

. CATAWBA NUCLEAR STATION -' UNITS-1 AND 2.

Page 51-

SUMMARY

.OF ENVIRONMENTAL QUALIFICATION OF' CLASS 1E' EQUIPMENT Rev. 5' LOCATED OUTSIDE CONTAINMENT AND'EXPOSEDLTO PIPE RUPTURE ENVIRONMENT.

. EQUIPMENT ID:

Cable ~-

MANUFACTURER: 'Okonite'

.MODELi#:

FR-EPR Control.

Insulation (Procurement

.(Ooghouse)

Specs:

CNS-1354.02-00-0001

'& 0002)'

PIPE RUPTURE ENVIRONMENT OPERABILITY-OPERABILITY ACCbRACY

. ACCURACY.

ENVIRONMENT TO WHICH.

REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

.(% OF.' SPAN)

ENVIRONMENT (2)

Temp:

440 F Temp: 455 F Continuous' Continuous N/A N/A Press:

8.85 psig Press:

32 psig RH:

100%

RH:

100%

'I

(

s t

QUALIFICATION REPORT:

Okonite Report #355 (CNM-1354.00-0022) e METHOD:

Test REPLACEMENT INTERVAL:

N/A EPSS

ym

(~}

-(}n LJ

+

CATAWBA NUCLEAR' STATION - UNITS 1 AND 2

.Page 52

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Rev. 5 LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE. RUPTURE ENVIRONMENT-

, EQUIPMENT-ID:

Cable -

MANUFACTURER:

Okonite MODEL #:

Tefzel' Hookup Wire

.(Doghouse)

Insulation-(Procurement Spec:

CNS-1354.04-00-0006)'

PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY

. ACCURACY ENVIRONMENT TO WHICH

-REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2)

Temp:

440 F Temp:

455 F Continuous Continuous N/A N/A Press: 8.85 psig Press:

32, psig RH:

100%

RH:

100%

QUALIFICATION REPORT:

Okonite Report #344 (CNM-1354.00-0026)

METHOD:

Test REPLACEMtNT INTERVAL: N/A EPSS

~.

,a Id

(

k)

~

. CATAWBA NUCLEAR STATION - UNITS 1 AND.2 Page 53.

~~

SUMMARY

OF ENVIRONMENTAL. QUALIFICATION OF CLASS 1E EQUIPMENT-Rev. 5' LOCATED 0UTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT.

EQUIPMENT ID:

Cable Termination' MANUFACTURER:

Ray Chem.

MODEL.#: WCSF-N ~

Splice Material (Doghouse)

PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY' ACCURACY ACCURACY-ENVIRONMENT TO WHICH REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF. SPAN).

(% OF SPAN)

ENVIRONMENT (2)

Temp:

325 F*

Temp:

360 F 5.63 min.

6.3 min.

N/A N/A Press: 8.85 psig Press:

70 psig RH:

100%

Ril:

100%

  • Doghous e envirrnment at time safety function completed - Ref. CNC-1381.05-00-0156.

QUALIFICATION REPORT:

71100 & F-C4033-3 (CNM-1367.01-0001 & 2)

METHOD: Test REPLACEMENT INTERVAL:

N/A EPSS

.y. _

c qs ;

P ~

CATAWBANUCLNARSTATION-UNITS 1AND2' Page 53ai SUP91ARY OF ENVIRONMENTAL QUALIFICATION OF CLASS IE EQUIPMENT ~

' LOCATED OUTSIDE CONTAINMENT AND-EXPOSED T0 PIPE RUPTURE ENVIRONMENT..

-:Rev. 5 EQUIPMENT ID: -Cable Termination

-MANUFACTURER:

Ray Chem MODEL #: WCSF-N' Splice Material l

l PIPE RUPTURE.

ENVIRONMENT

-OPERABILITY'-

OPERABILITY ACCURACY ACCURACY ENVIRONMENT TO WHICH REQUIRED IN

. DEMONSTRATED REQUIRED l

(1)

QUALIFIED

-PIPE' RUPTURE _

,(% OF SPAN).

DEMONSTRATED.

(% OF SPAN)

-ENVIRONMENT (2)

-Temp: 262 F Temp:

360*F Continuous Continuous

.N/A

'N/A-

RH:

100%

. RH:

100%

l I

QUALIFICATION REPORT:

71100 & F-C4033-3 (CNM-1367,01-0001 & 2)

METHOD: Test

-REPLACEMENT INTERVAL:

N/A EPSS l

~

i j

CATAWBA NUCLEAR STATION - UNITS 1 AND 2 Page 54

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Rev. 5' LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT EQUIPMENT ID:

Seal Material for Cable MANUFACTURER:

3M MODEL #:

Scotch Cast 9 Epoxy Entrance Fittings (XR-5240)

(Doghouse)

PIPE RUPTURE ENVIRONMENT OPERABILITY OPERABILITY ACCURACY ACCURACY ENVIRONMENT TO WHICH REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2)

Temp:

325 F*

Temp:

350*F 5.63 min.

6.15 min.

N/A N/A Press:

8.85 psig Press:

18 psig RH:

100%

RH:

100%

  • Doghouse environment at time safety function completed - Ref. CNC-1381.05-00-0156.

QUALIFICATION REPORT:

CNC-1381.05-00-0039 and Wy'le Report #44390-1, Rev. A (CNM-1364.00-0001) r METHOD:

Test / Analysis EPSS

a l

9 3

CATAWBA NUCLEAR STATION - UNITS 1 AND 2 Page 54a SUf11ARY OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Rev. 5 LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO PIPE RUPTURE ENVIRONMENT EQUIPMENT ID:

Seal Material for Cable MANUFACTURER:

3M MODEL #:

Scotch Cast 9 Epoxy Entrance Fittings (XR-5240)

PIPE RUPTURE ENVIRONMEtiT OPERABILITY OPERABILITY ACCURACY ACCURACY ENVIR0" MENT TO WilICH REQUIRED IN DEMONSTRATED REQUIRED DEMONSTRATED (1)

QUALIFIED PIPE RUPTURE

(% OF SPAN)

(% OF SPAN)

ENVIRONMENT (2)

Tez:

262 F Temp:

350 F Continuous Continuous N/A N/A Ril:

' 0%

Ril:

100%

QUALIFICATION REPORT:

CNC-1381.05-00-0039 and Wyle Report #44390-1, Rev. A (CNM-1364.00-0001)

METil00:

Test / Analysis EPSS

c n

PRM-1 (Page1) o Rev. S f

a.

6 CATAWBA NUCLEAR STATION - UNITS 1 AND 2

/

~ ENVIRONMENTAL QUALIFICATION OF CLASS 1E ELECTRICAL EQUIPMENT LOCATED OUTSIDE CONTAINMENT EXPOSED TO PIPE RUPTURE ENVIRONMENT

- Note 1 The methods employed to evaluate pipebreaks and to determine the resulting environmental parameters are discussed in Section 3.6 of the Catawba FSAR.

Note 2 The pipe rupture environment is assumed to exist for 2 1/2 hours (except for one area of the Auxiliary Building, Elevation 543' which exists for 2 5/6 hours) based on 30 minutes at the peak temperature after which action by the operator isolated the break and allows the Auxiliary Building temperature to decrease to normal in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

Use of the term " Continuous" indicates operability required /

demonstrated throughout the pipe rupture period.

The pipe rupture environmental analysis for the Doghouse was conducted seperately taking into consideration different sizes of ma'a steam line breaks, The equipment summary sheet parameters are based on the " worse case" size break with respect to actuation time of the equipment and the time when the Doghouse temperature reaches the qualification temperature of the equipment.

All equipment located in the Doghouse is identified under " Equipment ID".

s

')

Pressure:

Not a signiff. cant qualification parameter for pipe rupture outside the containment since all locations outside containment are open areas not susceptable to pressure build-up.

It should be noted that the pressure in the doghouse is a spike (8.85 psig) of less than 1 sec. duration.

Relative Humidity:

For outside containment ruptures of piping systems operating at temperatures less than 200 F, area relative humidity is not a significant qualification parameter.

This pipe rupture temperature precludes flashing of the liquid which could significantly increase area relative humidity. Additionally, evaporation of the liquid does not significantly increase area relative humidity due to the large open areas in which the pipe rupture occurs and the relative short duration of the pipe rupture.

Radiation:

There is no significant increase in radiation levels outside the containment as a result of a pipe rupture outside the containment.

Chemical Spray:

Not a qualification parameter for pipe rupture outside the contaiment since there is no chemical spray outside the containment.

(

)

_/

~

.------------.w

PRN-1 (Page2)

Rev. 5

-. n

. Submergen'ce:

Based on analysis 'erformed by Duke Power Company,.it has been p

1,

~ determined that there is no safety related electrical equipment, required to mitigate.the event causing the flood (e.g.', pipe rupture) or required to bring the plant to a safe shutdown-condition given a flood event, located below the postulated flood levels.

Note'3

~

The equipment listed is a NEMA 4 enclosure containing general application devices (e.g., relays ~,. switches, terminal blocks, etc.).-

The qualified environment is

-dictated by the single' limiting device contained in the enclosure.

The enclosure and device qualification is documented in calculation CNC-1381.05-00-0054.

V O

Y.

gf.fA se r t

+

-p ATTACHMENT 4

^

SUMMARY

OF ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT LOCATED OUTSIDE. CONTAINMENT AND EXPOSED TO THE i

~ POST-LOCA RECIRCULATION RADIATION ENVIRONMENT 7

- Paste.

Rev.

~ h Rev.

Page Rev.

1 :-

1 36

-- I

' 70 3

'2~

1-37 1

71 3

3-

'1 38 1

-72 3

~~

4 1

39 2

73 3

5 1

40 4-74 0

6

'D

7-1

~ 41 1

75 0

42 1

76 0

I 8

D.

43 1

77 0

.9.

3 44 1

78 0

10

.D 45 1

79 0

11 D

46 1~

80-0

'12 4

47 1

RN-1 1

13 4

48

.1 1

14" 2-49-1

'15 2

50 1

0 16 4

51 1

17
D 52 3-18 4

53 1

19 3'

54 1

20' 1.

55-1

-21 1;

56 2

22.

D

' 57-2 23 2-58

,1 i

24 3

-59 3

25

,3 60 5-26' 3

61 3

27 3

62-4 28 3

63 0

i 29 3

64 3

29A 3

65 4

30' 3

66 3

131 D

67 3-32 1

68 3

33 1.

69.

3

~34,

-1 35--

1

- *D - Deleted:

It has been determined that this equipment is not in the scope of 10CFR50.49 due to plant / system design changes, relocation to a mild environment area, or review of function and failure mode

(

with respect to the event causing the harsh environment.

t Revision 5 i

a

. ~... -

j-CATAWBA NUCLEAR STATION - UNITS 1 AND 2'

Page 60-

SUMMARY

OF-ENVIRONMENTAL QUALIFICATION OF CLASS 1E' EQUIPMENT '

.. Rev. 5 l

LOCATED OUTSIDE CONTAINMENT AND EXPOSED TO THE POST-LOCA RECIRCULATION RADIA l

I EQUIPMENT ID:

IEATC9A

. MANUFACTURER:. Duke MODEL df:. N/A -

(1) l (3) 4 RECIRCULATION.

RADIATION i

RADIATION-LEVEL TO WilICH

)

ENVIRONMENT QUALIFIED i

(TID) (2)

(TID) 1 3

i

{

1.2X104 RAD 1.24X104 RAD i

i i

l l

l

. QUALIFICATION REPORT: Ci,C-1381.05-00-0054

.e METHOD: Test / Analysis REFi.ACEMENT INTERVAL:.N/A~

ECSE

'