Responds to IE Bulletin 84-03 Re Refueling Cavity Water seal.Pneuma-seal to Be Installed in Sept 1984.Evaluation of Accident Potential & Consequences Will Be Submitted to NRC Prior to Placing Seal in Svc
ML20097C584
Person / Time
Site: Robinson 
Issue date: 08/31/1984
From: Mcduffie M
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-84-03, IEB-84-3, NLS-84-396, NUDOCS 8409170155
Download: ML20097C584 (2)


Text

r-z-

  1. (.

' ' 1, _ s,,

r CD&L I'

Carolina Power & Light Company 4

SERIAL: NLS-84-396 gN.3p)gg4 SEP 1 pg 18 r.

Mr.l James P. O'Reilly, Regional Administrator United States Nuclear Regulatory Commission

~ Suite l2900 101 Marietta. Street, NW Atlanta, GA 30303' H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261/ LICENSE NO. DPR-23 IE BULLETIN NO. 84-03

' REFUELING CAVITY WATER SEAL i

i:

Dear Mr. 0Reilly:

Carolina Power &-Light Company (CP&L) has reviewed the subject bulletin and provides the following initial response..

'ThelH. B. Robinson Steam Electric Plant Unit No. 2 (HBR2) is currently in a

Steam Generator Replacement-Outage which includes refueling. -At this time, g

lall'of the fuel is stored in the Spent' Fuel Pit, the Spent Fuel Pit gate valve

=is closed, and the water level in the refueling cavity is below the reactor vessel flange..The refueling cavity water seal (pneuma-seal) is scheduled to

.be placed in service during the latter part of September. The installation of the pneuma-seal at HBR2'is different from the seal arrangement sketch provided in the subject. Bulletin. The pneuma-seal at HBR2 incorporates a backing ring

['

~

which acts both as physical protection and as an aid to hold the pneuma-seal

.in' place.

1

'An evaluation of the potential for and consequences of a pneuma-seal failure

-is in progress. A summary of this evaluation, as requested by the Bulletin,

[

will be provided to your office prior to placing the pneuma-seal in service.'

4 411 Fayetteville Street

  • P. O. Box 1551
  • Ra:eigh. N. C. 27602
  • 0 T 8409170155 840831 f H ADOW 05000

((pj

. e.

.Mr. James P. O'Reilly.If you have any. questions.concerning this response, please contact Mr. Sherwood R. Zimmerman at (919) 836-6242.

Yours very truly, M. A. McDuffie Senior Vice President Nuclear Generation ONH/CLW/cfr (5570NH)

Attachment M. A. McDuffie, having been first duly sworn, did depose and say that the infor. nation contained herein is true and correct to the best of his

' nformation, knowledge and belief; and the sources of his information are i

officers, employees, contractors, and agents of Carolina Power & Light Company.

dwo k.Voukw df/f!Q D##,

My commission expiree:

V.0TAny g(' g cc:

Mr. G. Requa (NRC)

Mr. S. Varga NRC Resident Inspector (RNP)

{

i

% PUBL\\C i l

.......... y

,00VNd.,,o w