II I

DukeIbwer Cornpany T C McMam McGuire Nuclear Generatton Department Vice hesident 12iOOHagers fenyRoad(MG0lW)

(7M)8754800 Huntermlie, NC280784985 (704)8754809 Fax

\\

DUKEPOWER December' 27,1995 Document Control Desk U S Nuclear Regulatory Commission Washington, DC 20555

Subject:

McGuire Nuclear Site, Docket Nos. 50-369,-370 Submission of Section D, McGuire Nuclear Site Emergency Plan Adoption of NUMARC/NESP-007, Rev. 2 Classification Scheme Duke Power Company is submitting the classification scheme provided in NUMARC/NESP-007, Rev. 2, for McGuire Nuclear Site. Approval of the submittal is requested prior to final implementation. A table showing the disposition of NUMARC/NESP-007, Rev. 2 Initiating Conditions and Emergency Action Levels (EAL) in the McGuire EAL submittal is enclosed. A B ASIS document is provided which cross-references the initiating conditions described in the NUMARC document. A copy of the classification procedure is also enclosed.

This procedure has been reviewed by the state and local governments within the plume exposure EPZ. Their concurrence letters are enclosed. If there are any l

questions regarding the submittal, please contact Becky Hasty at (704) 875-4662.

Yours truly, fG/d T. C. McMeekm TCM/emk

Enclosures:

1) Disposition of NUMARC/NESP-007, Rev. 2 Initiating i

Conditions and Emergency Action Levels (EAL)in the McGuire EAL submittal

2) McGuire Emergency Plan Section D
3) McGuire Procedure RP/0/A/5700/00 7
4) State and County concurrence letters ggggg I

9601030244 951227 k ')!

PDR ADOCK 05000369 F

PDR r.

, a, _

m

US Nuclear Regulatory Commission December 27,1995 Page - 3 bec:

R. L. Hasty (w/ attachment)

E. M. Kuhr (w/ attachment)

ELL EP File 9

1 ENCLOSURE 1 Disposition of NUMARC/NESP-007, Rev. 2 Initiating Conditions and Emergency Action Levels (EAL) in McGuire EAL submittal

McGuire Nuclear Site Disposition of NUMARC/NESP-007, Rev. 2 IC/EAL in McGuire EAL Submittal NUMARC IC/EAL McGuire EAL Recognition Category and EAL Number Recognition Category A AUl/l Abnormal Rad Levels / Radiological Emuent 4.3.U.1-1 and -2 AUl/2 Abnormal Rad Levels / Radiological Emuent 4.3.U.1-3 and -4 AUl/3 Deleted -- McGuire does not have perimeter monitors AUl/4 Deleted -- McGuire does not have real time dose assessment AU2/1 Abnormal Rad Levels / Radiological Emuent 4.3.U.2-1 AU2/2 Abnormal Rad Levels / Radiological Emuent 4.3.U.2-2 AU2/3 Deleted -- McGuire does not have dry fuel storage AU2/4 Abnormal Rad Levels / Radiological Emuent 4.3.U.2-3 AAl/l Abnormal Rad Levels / Radiological Emuent 4.3. A.1-1 and -2 AAl/2 Abnormal Rad Levels / Radiological Emuent 4.3. A.1-3 and -4 AAl/3 Deleted -- McGuire does not have perimeter monitors AAl/4 Deleted -- McGuire does not have real time dose assessment AA2/1 Abnormal Rad Levels / Radiological Emuent 4.3. A.2-1 AA2/2 Abnormal Rad Levels / Radiological Emuent 4.3. A.2-3 i

AA2/3 Abnormal Rad Levels / Radiological Emuent 4.3. A.2-3 l

AA2/4 Abnormal Rad Levels / Radiological Emuent 4.3.A.2-2 AA3/1 Abnormal Rad Levels / Radiological Emuent 4.3. A.3-1 AA3/2 Abnormal Rad Levels / Radiological Emuent 4.3.A.3-2 ASl/l Abnormal Rad Levels / Radiological Emuent 4.3.S.1-1 ASl/2 Deleted -- McGuire does not have perimeter monitors ASI/3 Abnormal Rad Levels / Radiological Emuent 4.3.S.1-2 ASl/4 Abnormal Rad Levels / Radiological Emuent 4.3.S.1-3 AG1/l Abnormal Rad Levels / Radiological Emuent 4.3.G.1-1 AGl/2 Deleted -- McGuire does not have perimeter monitors AGl/3 Abnormal Rad Levels / Radiological Emuent 4.3.G.1-2 AGl/4 Abnormal Rad Levels / Radiological Emuent 4.3.G.1-3

McGuire Nuclear Site Disposition of NUMARC/NESP-007, Rev. 2 IC/EAL in McGuire EAL Submittal NUMARC IC/EAL McGuire EAL Recognition Category and EAL Number Recognition Category F FPB Fuel /l Fission Product Barrier 4.1.F.I FPB Fuel /2 Fission Product Barrier 4.1.F.2 FPB Fuel /3 Deleted -- Core exit thermocouples are monitored as part of Critical Safety Function (CSF) status. If the OAC is not available, manual monitoring is done per EP/1 or 2/A/5000/10 and will be used to classify.

FPB Fuel /4 Deleted -- Reactor Vessel level is monitored as part of CSF status. If the OAC is not available, manual monitoring is done per EP/l or 2/A/5000/10 and will be used to classify.

FPB Fuel /5 Fission Product Barrier 4.1.F.3 FPB Fuel /6 Deleted -- McGuire does not believe additional indications are needed to determine Fuel Clad Barrier status. Air sampling (PAGS) results are not used, is containment monitors can be used to determine Fuel Clad status.

FPB Fuel /7 Fission Product Barrier 4.1.F.4 FPB RCS/l Fission Product Barrier 4.1.N.1 FPB RCS/2 Fission Product Barrier 4.1.N.2 l

FPB RCS/3 Fission Product Barrier 4.1.N.3 Note: The classification procedure does not provide site specific criteria that a steam generator is mptured. Duke Power's philosophy is that diagnostic information of this type belongs in the Emergency Operating Procedures. Once the Emergency 1

Coordinator / EOF Director determines that a steam generator is mptured, the classification procedure can be used to determine the correct classification.

FPB RCS/4 Fission Product Barrier 4.1.N.4 FPB RCS/5 Deleted -- McGuire does not believe additional indications are needed to determine Reactor Coolant System Barrier status. Air sampling (PAGS) results are not used, as containment monitors can be used to determine Reactor Coolant System Barrier status.

FPB RCS/6 Fission Product Barrier 4.1.N.5 FPB Containment /l Fission Product Barrier 4.1.C.1 FPB Containment /2 Fission Product Barrier 4.1.C.2 FPB Containment /3 Fission Product Barrier 4.1.C.3 FPB Containment /4 Fission Product Barrier 4.1.C.4 FPB Containment /5 Fission Product Barrier 4.1.C.5 FPB Containment /6 Fission Product Barrier 4.1.C.6 Core exit thermocouples are monitored as part of CSF status. If the OAC is not available, manual monitoring is donc per EP/l or 2/A/5000/10 and will be used to classify.

FPB Containment /7 Deleted -- no additional indications needed FPB Containment /8 Fission Product Barrier 4.1.C.7

McGuire Nuclear Site Disposition of NUMARC/NESP-007, Rev. 2 IC/EAL in McGuire EAL Submittal NUMARC IC/EAL McGuire EAL Recognition Category and EAL Number Recognition Category H HUl/l Nattiral Disasters, Hazards, etc. 4.7.U.1-1 and -2 i

HUl/2 Natural Disasters, Hazards, etc. 4.7.U.1-3 HUl/3 Deleted -- McGuire considers this redundant to Emergency Director Judgement j

HU1/4 Natural Disasters, Hazards, etc. 4.7.U.1-4 HUI/5 Fire and Security 4.6.U.1-2 HUl/6 Natural Disasters, Hazards, etc. 4.7.U.1-5 1

HUl/7 Deleted -- McGuire believes no additional items are needed based on currently approved EALs i

HU2/1 Fire and Security 4.6.U.1-1 1

HU3/1 Natural Disasters, Hazards, etc. 4.7.U.2-1 HU3/2 Natural Disasters, Hazards, etc. 4.7.U.2-2

)

HU4/1 Fire and Security 4.6.U.2-1 HU4/2 Fire and Security 4.6.U.1-2 and -3 HU5/1 Natural Disasters, Hazards, etc. 4.7.U.3-1 HAl/l Natural Disasters, Hazards, etc. 4.7. A.1-1 HAl/2 Natural Disasters, Hazards, etc. 4.7. A.1-2 H A l.3 Natural Disasters, Hazards, etc. 4.7. A.1-3 HAl/4 Natural Disasters, Hazards, etc. 4.7. A.1-3 HAl/5 Natural Disasters, Hazards, etc. 4.7. A.1-3 HAl/6 Natural Disasters, Hazards, etc. 4.7.A.1-3 HAl/7 Natural Disasters, Hazards, etc. 4.7. A.1-3 HA2/1 Fire and Security 4.6.A.1-1 HA3/1 Natural Disasters, Hazards, etc. 4.7. A.2-1 HA3/2 Natural Disasters, Hazards, etc. 4.7. A.2-2 HA4/1 Fire and Security 4.6.A.2-1 HA4/2 Deleted -- McGuire believes no others necessary based on currently approved EALs HA5/1 Natural Disasters, Hazards, etc. 4.7. A.3-1 HA6/1 Natural Disasters, Hazards, etc. 4.7. A.4-1 HSl/l Fire and Security 4.6.S.1-1 HSl/2 Fire and Security 4.6.S.1-2 and -3 HS2/1 Natural Disasters, Hazards, etc. 4.7.S.1-1 HS3/1 Natural Disasters, Hazards, etc. 4.7.S.2-1 HGl/l Fire and Security 4.6.G.1-1 HGl/2 Fire and Security 4.6.G.1-2 HG2/1 Natural Disasters, Hazards, etc. 4.7.G.1-1

McGuire Nuclear Site Disposition of NUMARC/NESP-007, Rev. 2 IC/EAL in McGuire EAL Submittal NUMARC IC/EAL McGuire EAL Recognition Category nnd EAL Number Recognition Category S SUl/l Loss of Power 4.5.U.1-1 SU2/1 System Malfunction 4.2.U.1-1 SU3/1 System Malfunction 4.2.U.2-1 SU4/1 Deleted -- McGuire has no failed fuel monitor. Reactor coolant sampling is used to determine fuel clad degradation.

SU4/2 System Malfunction 4.2.U.3-1 SU5/1 System Malfunction 4.2.U.4-1, -2, and -3 SU6/1 System Malfunction 4.2.U.5-1 and -2 SU7/1 Loss of Power 4.5.U.2-1 sal /l Loss of Power 4.5. A.1-1 SA2/1 Loss of Shutdown Function 4.4. A.1-1 SA3/1 Loss of Shutdown Function 4.4.A.2-1 and -2 SA4/1 System Malfunction 4.2. A.1-1 SAS/l Loss of Power 4.5. A.2-1 SS1/1 Loss of Power 4.5.S.1-1 SS2/1 Loss of Shutdown Function 4.4.S.1-1 SS3/1 Loss of Power 4.5.S.2-1 SS4/1 Loss of Shutdown Function 4.4.S.2-1, -2, and -3 SS5/1 Loss of Shutdown Function 4.4.S.3-1, -2, and -3 SS6/1 System Malfunction 4.2.S 1-1 SGl/l Loss of Power 4.5.G.1-1 SG2/1 and 2 Loss of Shutdown Function 4.4.G.1-1

_