ML20094M355
| ML20094M355 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 11/20/1995 |
| From: | Keaten R GENERAL PUBLIC UTILITIES CORP. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| 5000-95-0094, 5000-95-94, C321-95-2331, GL-92-01, GL-92-1, NUDOCS 9511270023 | |
| Download: ML20094M355 (2) | |
Text
1 GPU Nuclear Corporation r%
g yn One Upper Pond Road
'i wSEE Parsippany, New Jersey 07054 201-316-7000 TELEX 136-482 Writer's Direct Dial Number.
November 20,1995 5000-95-0094 C321-95-2331 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Gentlemen:
Subject:
Oyster Creek Nuclear Generating Station (OCNGS)
Operating License No. DPR-16 Docket No. 50-219 Response to Supplement I to Generic Letter (GL) 92-01, Revision 1
" Reactor Vessel Structural Integrity" Supplement 1 to the subject Generic Letter was issued on May 19,1995 and requested certain information concerning reactor vessel structural integrity. The requests are divided into four parts.
GPU Nuclear letter dated August 16,1995 endorsed a report entitled "BWRVIP Action Plan For RPV Integrity Data" which was submitted on behalf of the BWR licensees on August 10, 1995 by the BWR Vessel and Internals Project (BWRVIP) Group in response to Part 1 of the
" Required Information" in Supplement I to the Generic Letter. GPU Nuclear is a member of the BWRVIP Group.
o-eME The purpose of this letter is to inform you that on November 15, 1995, the BWRVIP N 8"-
submitted a report entitled, " Bounding Assessment of BWR/2-6 Reactor Pressure Vessel
'y@
Integrity issues" responding to Part 2 through Part 4 of the " Required Information." Prior to D'O the submittal, GPU Nuclear reviewed and concurred with the responses. Therefore, the
.Q November 15, 1995 BWRVIP submittal referenced above provides the remaining OCNGS gg responses to Supplement I to GL 92-01, Revision 1.
nc Ng As indicated in the BWRVIP report, no near term actions are needed in response to the issues g
raised in Supplement 1. Longer term efforts are being formulated and pursued with other industry groups through NEI. Based on the results of those longer term efforts, the BWRVIP will make appropriate recommendations to its member utilities.
gf n *l'r ? Q ff "Quu<>
f 0 GPU Nuclear Corporation is a subsidiary of General Public Utihties Corporation
i 6
C321-95-2331 Page 2 If you have any questions concerning this letter, please contact Mr. Yosh Nagai, of Regulatory Affairs at (201) 316-7974.
Sincerely,
)
}R. W. Keaten Vice President and Director Technical Functions RWK/YN/cb i
c: Administrator, Region I OC Senior Resident Inspector OC Senior Project Manager i
I Sworn and subscribed to before me thisJ d day of[0 VDMA6X 1995.
WntA O
6
'A Notary Public [INew Jerle(/
JULIENNE J. SCHOFFSTALL NOTARY PUBUC OF NEW JERSEY My Commission Expires June 24.1997