.s REACTIVITY CONTROL SYSTEMS POSITION INDICATION SYSTEM - SHUTCOWN

. LIMITING CONDITION FOR OPERATION 3.1.3.3 One digital rod position indicator (excluding demani:Iposition indication) shall be OPERA 8LE and capable of determining the control rod position within 212. steps for each shutdown or control rod not fully inserted.

APPLICA8ILITY: MODES 3*#, 4*#, and 58#.

(

ACTION:

With less than the above required position indicator (s) OPERABLE, immediately open the Reactor Trip System breakers.

~

l SURVEILLANCE REQUIREMENTS 4.1.3.3 Each of the above required digital rod position indicator (s) shall be detarmined to be OPERA 8LE by verifying that the digital rod position indicator

' agrees with the demand position indicator within 12 steps when exercised over the full-range of rod travel at least once per 18 months. %e%gfoe 3;9

?

$ s{em br<bers can be closed in enlet-lcfe&nn f;3 Susveillanc e.

~

i I

  • With the Reactor Trip System breakers in the closed position.
  1. See Special Test Exceptions Specification 3.10.5 l

G410230019 841019 PDR ADOCK 05000413 P

PDR t

CATAWBA - UNIT 1 3/4 1-18

._. _. _ _ _ _ _. _ - -. _... _. ~., _