6 Cf8&L Carolina Power & Ught Company SERIAL: NLS-84-203

..il4 P I : 5 2 g

y Mr. James P. O'Reilly, Regional Administrator United States Nuclear Regulatory Co*nnission Cuite 7900 101' Marletta Street, NW Atlanta,- GA 30303 37.UNSWICK LTEAM ELECTRIC PLAMf, UNIT NOS.1 AND 2 DOCKET NOS. 50-325 & 50-324) LICENSE NOS. DPR-71 & DPR-62

' RESPONSE TO IC BULLETIN E0-13

' EXAMINATION OF CORE SPRA! SYSTEM SPARGERS l

Dear Mr. O'Reilly:

By a letter dated May 12, 1980, you transmitted IE Bulletin 80-13 concerning cracking in core spray spargers. The bulletin requires that, during each refucIing, the results-of examinaticas of the core sprayf spargers and l

in-vessel piping be submitted to the NRC within 30 days of completing the examination.

. The Brunedick Steam Electric Plant Unit No. 2 core spray spargers and in-vessel piping have been visually inspected using Periodic Test 90.1.

No Indice,cion of additional cracking' was noted. The sparger clamp that was i

. Ipreviously installed was also inspected using Periodic Test 90.1 and was found i

to be satisfactory. This inspection was completed April 10, 1984.

If you have any questions concerning this matter, please contact our Licensing staff.-

Yours very t f

(

A. B. Cutter - Vice resident Nuclear Engineering & Licensing

. RM/pgp (990WRM)

W cc:

Mr. D. O. Myers (NRC-BSEP)

L Mr.'J. P. O'Reilly (NRC-RII)

[

Mr. M. Grotenhuis (NRC)

Mr. R. C. DcYoung (I&E) c 8406190246 840509 PDR ADOCK 05000324 i