ML20092A056

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Re Removal of Autoclosure Interlock from Sdcs Suction Valves
ML20092A056
Person / Time
Site: Millstone 
Issue date: 01/30/1992
From:
NORTHEAST NUCLEAR ENERGY CO.
To:
Shared Package
ML20092A051 List:
References
B14005, NUDOCS 9202060499
Download: ML20092A056 (2)


Text

- _ - - _ _ - _ _ _ _ _ _.

4 Docket No. 50-336 EliOM h

Millstone Nuclear Power Station, Unit No. 2 Proposed Revision to Technical Specifications Shutdown Cooling Systi.a Autoclosure Interlock 4

9

?

January 1992 JgRo2060499 920130 p

ADOCK 05000336 PDR l

.I

~

EMERGENCY CORE COOLING SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) 10.~

Verifying that_the following valves are in the indicated position with power to the valve operator removed:

l Valve Number.

Valve Function Valve Position 2-SI-306 Shutdown Cooling Open Flow Control 2-SI-659 SRAS Rec.irc.

Open*

1 2-SI-660-3 RAS Recirc.

Open*

2-CH-434 Thermal Bypass Closed **

}

b.

By a visual inspection which verifies that no loose debris-(rags, trash, clothing, etc.)'is~present in the containment which could be-transported to the containment sump and cause restriction-of-the pump suctions _during LOCA conditions. This visual inspection shall-be performed:

1.

For-all accessible areas of the containment prior to establishing CONTAINMENT INTEGRITY, and 2.

0f the areas affected within containment at-the completion of.

containment entry when CONTAINMENT INTEGRITY is established.

c.

At least'once pe* 18 months by:

1.

Verifying automatic interlock action of the shutdown cooling-system from the reactor coolant system by er.suring that with a simulated reactor _ coolant system pressure signal greater than or-equal to 300 psia the interlock prevents the shutdown cooling systcm suction valvestfrom being opened.

1

-2.-

A visual.--inspectior, of the containment sump and-verifying that the subsystem suction inlets;are not restricted by debris and S

that the sump components (trash racks, screens,-etc.) show no evidenceL of structural-distress or corrosion.-

__o 3.

-Verifying that-a: minimum total of.110 cubic feet of trisodium phosphate dodecahyditte (TSP) is contained within the TSP storage baskets.

p 4.

Verifying that when a representative sample of 0.35 i 0.65:lbs of TSP from a TSP storage basket is submerged, without~

agitation, in 50 5 gallons of 180 i 10*F borated water from

.the RWST, the pH of the' mixed solution is raised to'1 6 within'

~4 hours.

  • To be closed prior to recirculation following LOCA.
    • 2-CH 434, a manual valve, shall be locked closed a

MILLSTONE - UNIT 2 3/4 5-5 AmendmentNo;7,#,M,/d/

0049.

h*

-d..

.i-

,m

.,,y y

y