Text
.
1 t
ENCLOSURE 1 SERIAL: NLS-84-062 i
BRUNSWICK STEAM ELECTRIC PLANT PROPOSED TECHNICAL SPECIFICATION PAGES - UNIT 1
' s..
(CP&L SERIAL 84TSB06) 1 i'
I B406120183 840606 PDR ADOCK 05000324 p-PDR t.
--w
-r-
s'*
4 s-Sif.cfARY LIST OF REVISIONS BRUNSWICK UNIT 1 PAGE COBE!ENT 1-10 Added Footnotes (#) and (##)
Revised Footnotes (*), (**),
and (***)
Changed Column Title to " AVERAGE REACTOR COOLANT TDiPERATURE" e
t 9
0 O
e I ~
I~
i I
l
+- - -,. - - - -,,
,...+
TABLE 1.2 OPERATIONAL CONDITIONS AVERAGE
.0PERATIONAL MODE SWITCH REACTOR COOLANT CONDITIONS POSITIONS TEMPERATURE 1.
POWER OPERATION Run Any temperature 2.
STARTUP Startup/ Hot Standby Any temperature 3.
HOT SHUTDOWN Shutdown #'***
> 212*F 4.
COLD SHUTDOWN Shu td own# ' # #' * *
- j( 212*F 5.
REFUELING
- Shutdown or Refuel ***#
< 212*F
- The reactor mode switch may be placed in the Run or Startup/ Hot Standby position to test the switch interlock functions provided that the control rods are verified to remain fully inserted by a second licensed operator or other technically qualified member of the unit technical staff.
- The reactor mode switch may be placed in the Refuel position while a single control rod drive is being. removed from the reactor pressure vessel per Specification 3.9.10.1.
- Fuel in the reactor vessel with the vessel head closure bolts less than
, fully tensioned or with the head removed.
- See Special Test Exceptions 3.10.1 and 3.10.3..
- The reactor mode switch may be placed in the Refuel position while a single control rod is being recoupled provided that the one-rod-out interlock is OPERABLE.
~
BRUNSWICK - UNIT 1 1-10 Amendment No.
i$',.1 i 9-a ENCLOSURE 2 SERIAL:
NLS-84-062 BRUNSWICK STEAM ELECTRIC PLANT PROPOSED TECHNICAL SPECIFICATION PAGES - UNIT 2 4.
(CP&L SERIAL 84TSB06) t 0
9 e
e O
':s_
Y
,d, s.
e-SIMtARY LIST OF REVISIONS BRUNSWICK UNIT 2 PAGE CO3DIENT 1-11 Added Footnotes (#) and (##)
Revised Footnotes (*), (**), and (***)
Changed. Column Title to " AVERAGE REACTOR COOLANT TDiPERATURE" e
9 O
e sama.
- .. i ' *,
g P
TABLE 1.2 OPERATIONAL CONDITIONS AVERAGE OPERATION.'4 MODE SWITCH REACTOR COOLANT CONDITIONS POSITIONS TEMPERATURE 1.
POWER OPERATION Run Any temperature 2.
STARTUP Startup/ Hot Standby Any temperature 3.
HOT SHUTDOWN Shutdown #'***
> 212'F 4.
COLD SHUTDOWN Shutdown #'##'***
1 212*F 5.
REFUELING
- Shutdown or Refuel **'#
1 212*F
- The reactor mode switch may be placed in the Run or Startup/ Hot Standby position to test the switch interlock functions provided that the control rods are verified to remain fully inserted by a second licensed operator or other technically qualified member of the unit technical staff.
- The reactor mode switch may be placed in the Refuel position while a single control rod drive is being removed from the reactor pressure vessel per Specification 3.9.10.1.
Fuel in the reactor vessel with the vessel head closure bolts less than fully tensioned or with the head removed.
- See Special Test Exceptions 3.10.1 and 3.10.3.
The reactor mode switch may be placed in the Refuel position while a single control rod is being recoupled provided that the one-rod-out interlock is OPERABLE.
BRUNSWICK.- UNIT 2 1-11 Amendment No.
.