First Interim Deficiency Rept NCR 3102 Re Use of Incorrect Adaptors on Instrumentation Lines.Initially Reported on 840510.Investigation Expanded to Include 1-inch Adaptors. Next Rept Will Be Submitted by 840928
ML20091M573
Person / Time
Site: Bellefonte  
Issue date: 06/04/1984
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NCR-3102, NUDOCS 8406110349
Download: ML20091M573 (2)


Text

G.

~'

D

c _.

TENNESSEE -VALLEY AUTHORITY CHATTANOOGA TENNESSEE 374ol 400 Chestnut Street Tower II

$4 jUN k June 4, 1984 BLRD-50-438/84-35 BLRD-50-439/84-32 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator

.101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - USE OF INCORRECT ADAPTORS ON INSTRUMENTATION LINES - BLRD-50-438/84-35, BLRD-50-439/84 FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector P. E. Fredrickson on May 10, 1984 in accordance with 10 CFR 50.55(e) as NCR 3102. Enclosed is our first interim report. We expect to submit our next report by September 7.8, 1984.

If you have any questions, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY DSY m kL.M. Mills, Manager.

I Nuclear Licensing Enclosure cc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center (Enclosure)

Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Deorgia 30339 8406110349 840604 PDR ADOCK 05000438 6

..PDR 1983-TVA SOTH ANNIVERSARY p

An Equal Opportunity Employer j8 k

I ENCLOSURE I

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 e

g USE OF INCORRECT ADAPTORS ON INSTRUMENTATION LINES i

BLRD-50-438/84-35, BLRD-50-439/84-32 NCR 3102 10 CFR 50.55(e)

FIRST INTERIM REPORT

-Description of Deficiency A problem has been identified at Bellefonte which involves adaptors (sized 3/4-inch and under) used to connect instrument piping to instrument tubing.

For' tube-to-pipe adaptors with TVA Mark Nos.142, 155, 158, 690, 691, 692, and 778, the TVA mark number or schedule is not affixed to the adaptor (they are not required to be), and the proper schedule adaptor required by design drawings may not have been used in all cases.

.The apparent cause of this deficiency is the lack of schedule identifica-tion on the adaptors and the fact that documentation of inspection verification of the adaptor's schedule is not required by present quality control procedures.

Interim Progress TVA has expanded the investigation of this deficiency to include 1-inch adaptors, and we will provide additional information after the investi-gation is complete.