KANSAS GAS AND ELECTRIC COMPANY THE ELECTPC COMPANY OLENN L MOESTER WCE Pt.ES.OE9s? - NUCLEAR June 1, 1984 I

Mr. E.H. Johnson, Acting Chief Reactor Projects Branch 2 g

U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 1000 M

fg Arlington, Texas 76011 uI KMLNRC 84-083 2

Re:

Docket No. STN 50-482 Subj: Potential 10CFR50.55(e) Interim Report - Standby Diesel Generator "B" Left Bank Turbocharger

Dear Mr. Johnson:

This letter provides an interim report on a potential 10CFR50.55(e) concerning the "B" Standby Diesel Generator left bank turbocharger.

This matter was initially reported by Mr. H.K. Chernoff of Kansas Gas and Electric Company (KGEE) to Mr. Johns Jaudon of the Nuclear Regulatory Commission, Region IV, on May 4,1984.

During testing of the "B" Standby Diesel Generator (KJ-01-B) front and rear bearings on the left bank turbocharger failed. Inspection and preliminary investigation revealed the possible cause of failure as a loose lock nut on the turbocharger lube oil pump centrifuge.

The standby diesel generator turbochargers were assembled at Wolf Creek Generating Station.

The status of this potential 10CFR50.55(e) will be carried on the

. monthly status update as file 53564-K138. The final report or any significant new information will be submitted by separate correspondence.

In the interim, please direct any questions to me or to Mr. Otto Maynard of my staff.

Yours very truly,

{er*

Glenn L. Koester GLK:bb Vice President - Nuclear xc: RCDeyoung PO'Connor HBundy 8406110120 840601 i

PDR ADOCK 05000482

-[

l 8

PDR

)-

-- 201 N. Market -WicNta Kansas -Mail Address: RO. Box 200 i WVcNta, Kansas 67201 - Telephone: Area Code (316) 261645I lh

.