Safety Evaluation Supporting Amend 100 to License DPR-49
ML20091J718
Person / Time
Site: Duane Arnold 
Issue date: 05/22/1984
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20091J716 List:
References
NUDOCS 8406060126
Download: ML20091J718 (2)


Text

M

[\\

UNITED STATES

^

NUCLEAR REGULATORY COMMISSION j (W)nj YC ~ %/,}

WASHINGTON, D. C. 20555 yv

)

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUPPORTING AMENDMENT N0.100 T0 LICENSE NO. DPR-49 IOWA ELECTRIC LIGHT AND POWER COMPAtlY CENTRAL IOWA POWER COOPERATIVE 1

CORN BELT POWER COOPERATIVE DUANE ARNOLD ENERGY CENTER DOCKET NO. 50-331 1.0 Introduction The staff position letter dated November 28, 1978, req'uested licensees to cease purging (or venting) of containment or limit purging (or venting) to an absolute minimum. Licensees who elected to purge (or vent) the containment were requested to demonstrate that the containment purge (or vent) system design met the criteria outlined in the Standard Review Plan (SRP) Section 6.2.4, Revision 1, and the associated staff Technical Position (BTP) CSB 6-4, Revision 1.

The licensee, by letter dated March 15, 1982, responded to our request by providing infonnation related to purge / vent system design and operation. Subsequently, by letter dated June.10, 1982, the licensee submitted a request for Technical Specification changes arising out of the resolution of issues related to staff Technical Position CSB 6-4, 2.0 Evaluation The purging and venting operation at the Duane Arnold Energy Center (DAEC) is performed through redundant 18-inch butterfly-type isolation valves in both supply and exhaust headers of the drywell and suppression pool. The 18-inch valves are bypassed by 2-inch globe valves which are used to inert and deinert the containment with nitrogen.

By letter dated June 10, 1982, the licensee proposed the following changes to the DAEC Technical Specifications dealing with operation of the purge / vent system:

1.

The operation of purge / vent systems will be restricted to 90 hours0.00104 days <br />0.025 hours <br />1.488095e-4 weeks <br />3.4245e-5 months <br /> per year not including a 24-hour. period prior to shutdown and a 24-hour period after placing the reactor in run mode; 2.

Purge / vent system leakage integrity tes'.s are to be conducted at intervals not to exceed once every three months; and 3.

Purge / vent isolation valve seal is to be replaced at intervals not to exceed four years.

~

8406060126 840522 PDR ADOCK 05000331 p

PDR t.

J,

c l

On March 29, 1984, we issued a Safety _ Evaluation for the conta'inment purge / vent-system design and operation practices for DAEC, In that Safety

. Evaluation we found the purge / vent system operating frequency (item 1) and leakage integerity testing frequency (item 2) to be acceptable. We have reviewed the frequency of purge valve seal replacement (item 3) and found that the frequency of replacement of the purge isolation valve seal is acceptable, since it meets our guidance provided in the sample Technical Specifications included in our letter dated November 24, 1981.

3.0 Environmental Considerations We have determined that the amendment does not authorize a change in effluent types or total amounts nor an increase in power level and will not result in any significant environmental impact. Having made this determination, we have further concluded that the amendment involves an action which is insignificant from the standpoint of environmental impact, and pursuant to 10 CFR 551.5(d)(4), that an environmental impact statement, or negative declaration and environmental impact appraisal need not be prepared in connection with the issuance of this amendment.

4.0 Conclusion We have concluded, based on the considerations discussed'above, that (1) there is reasonable assurance.that the health and safety of the public will not be endangered by operation in the proposed manner, and (2) such 3;tivitics_will be conducted.in compliance with the Commission's regulations, and the issuance of this amendment will not be. inimical to the common defense and' security or to the health and safety of the public.

Principal Contributor: R.-Hall Dated: !1ay 22,1S84 J