A j# "*'4k UNITED STATES e"

NUCLEAR REGULATORY COMMISSION ch j

WASHINGTON, D. C. 20555 o-CAROLINA POWER & LIGHT COMPANY 4

DOCKET NO. 50-324 BRUNSWICK STEAM ELECTRIC PLANT, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 96 License No. DPR-62 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Carolina Power & Light Company (thelicensee)-datedJanuary 10, 1984, complies with the standards 3

and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the' provisions of the Act, and the rules and regulations of the i

Commission; e

C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the i

.public; and

{

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations -and all applicable requirements have been satisfied.

2.

Accordingly, the-license is anended by changes to the Technical

-Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-62 is

'hereby amended to read as follows:

K O! b 4 PDR

. 2.

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 96, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Domenic B. Vassallo, Chief Operating Reactors Branch #2 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: May 8,1984

e i

i

ATTACHMENT TO LICENSE AMEN 0 MENT NO. 96 FACILITY OPERATING LICENSE NO. DPR-62 l

DOCKET NO. 50-324 Revise the Appendix A Technical Specifications by removing page 3/4 5-6 and inserting revised page 3/4 5-6.

The changed area is indiceted by vertical line.

i I

l l

s' ?

i

EMERGENCY CORE COOLING SYSTEMS 4

c

. SURVEILLANCE REQUIREMENTS (Continued) 4'

~ 2.

Verifying that each valve (manual, power-operated, or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

e c.

At least once per 92 days

  • by:

j 1.

Verifying that each CSS pump can be started f rom the control room and develops a flow of at least 4625 gpm on recirculation flow against a system head corresponding to a reactor vessel pressure of > 113 psig.

2.

Performing a CHANNEL CALIBRATION of the core spray header AP instrumentation (E21 dPIS-NOO4A,B) and verifying the setpoint to be 5, +1.5, psid greater than the normal indicated oP.

d.

At least once per 18 months by performing a system functional test which includes simulated automatic actuation of the system throughout its emergency operating sequence and verifying that each automatic-valve in the flow path actuates to its. correct position. - Actual injection of coolant into the reactor vessel is excluded from this test.,

\\

i j

=

I 4

s' I

1

  • The surveillance test required by this license in Appendix.A, paragraph i

4.5.3.1.C.1, regarding the flow test of the core spray system may be postponed during the current refueling outage (Reload 5) until.within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> af ter, restoration of the suppression chamber to 6perable ' status

~

1 but in any case no later than November 15,'1984.

4 BRUNSWICK

, UNIT 2 3/4l5 Amendment: No. 96

' l