Advises That Temporary Repair Enclosure Removed from 3/4 Inch Vent Line on MSL & Flawed Pipe Section Replaced on 910923.Util 901221 Relief Request Withdrawn
ML20091D416
Person / Time
Site: North Anna 
Issue date: 04/03/1992
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
92-222, NUDOCS 9204100120
Download: ML20091D416 (2)


Text

- - -

. ~..

YlltOINIA ALilCTitlC AND l'OWillt COMi%NY Q

H ICil M O N I), Yllm !N I A 2112 61 April 3, 1992 U. S. Nuclear Regulatory Commission Serial No.

92 222 Attn.: Document Control Desk

~ NL&P/TAH: RO Washington, D.C. 20555 Docket No. 50 339 Lic9nse No. NPF-7 Gentlemen:

yJRGINIA - ELECTRIC - AND POWER COMPANY NORTH ANNA POWER STATION UNIT NO. 2 WITHDRAWAL OF ASME SECTION XI RELIEF REQUEST TEMPO 9ARY NON-CODE REPAIR TO A CLASS 2 COMPONENT On December 21,1990, Virginia Electric and Pcwer Company submitted a ASME Section XI relief request, pursuant to 10 CFR 50.55a(g)(5), associated with a temporary non-code repair of a 3/4-inch vent line on the "A" main steam line for North Anna Unit 2. A pin hole leak had developed between the main steam trip valve and the non return valve outside of containment. The relief request described that the flaw was discovered during power operation and that the Unit would have had to be shut down in order to perform a Code repair.

The relief request also described that the temporary repair was an engineered, mechanical enclosure filled with a hardened liquid sealant that is. fabricated from l

' safety related materials and designed for the pressure and temperature rating of the main steam system. The request further stated that the engineered, temporary repair I

enclosure.was intended for use until the first opportunity for completion of a Code repair.

On September 23,1991, the temporary repair enclosure was removed and the flawed section of piping was replaced in accordance with ASME Section XI requirements. As l

a result _ of this repair activity, our_ December 21,1990 relief request is no longer needed and is withdrawa.

If you have any questions, please contact us.

E Very truly yours, l)b W. L. Stewart

-Senior Vice President - Nuclear

}

9204300i20 920403

^

PDR ' ADOcK 0500o339

.P PDR

c.

Docket No. 50 339 Serial No.92-222 cc: U.S. Nuclear Regulatory Commission Region 11 101 Marietta Stre'et, N.W.

Suite 2900 Atlanta, Georgia 30323 Mr. M. S. Lesser -

NRC Senior Resident inspector North Anna Power Station 3