NI AGARA MOH AWK POWER CORPORATION NI AG AR A MOHAWK Nine Mile Point Nuclear Station Post Office Box 32 Lycoming, New York 13093 August 1, 1972 Mr. Donald J. Skovholt Assistant Director for Reactor Operations Division of Reactor Licensing United States Atomic linergy Commission Washington, D. C.

20545

Dear Mr. Skovholt:

Re: Provisional Operating License: DPR-17 Docket No.:

50-220 On May 21, 1972, during the poison curtain removal outage at Nine Mile Point Nuclear Station, Unit #1, the main steam line isolation valves were leak tested.

Steam flow from the reactor to the turbine is thru two lines each with two isolation valves, one located inside the drywell, the other located outside the drywell. All four valves must meet the same time closure criteria as set forth in Technical Specification's Table 3.2.7.

revealed all valves except the outside valves in each line The first test were within the new leakage criteria of 12.9'SCFH.

Following repcirs to the outside isolation valves retesting of all four isolation valves on May 2S and 26, 1972 using a test of 22 psig air pressure revealed all within criteria.

Results for all valves follow:

  1. 11 Inside 6.3 SCFH
  1. 11 Outside 7.2 SCFH
  1. 12 Inside 0.0 SCFil
  1. 12 Outside 10.0 SCFil

{,sg 8303020158 720908 PDR ADOCK 05000 P

1

/

(3.

tm V#

()

Mr. Donald J. Skovholt Page 2 United States Atomic Energy Commission Details of the tests, calculations and procedures are on file at Nlnc Mile Point Nuclear Station, Unit #1 and may be examined or supplied to you if required.

Very truly yours,

_ma (d'. 42l.l. W, P. Allister Burt General Superintendent Nuclear Generation PAB:pw i