KANSAS GAS AND ELECTRIC COMPANY TF4i ELECTRIC COMPANY

@LENN L MOESTER WsCE PHES* DENT NWCLE44 March 30, 1984 Mr. J.E. Gagliardo, Acting Chief

[

{J hh Reactor Project Branch 2 U.S. Nuclear Regulatory Commission i,

Region IV

};i AR-3M 611 Ryan Plaza Drive, Suite 1000

{p Arlington, Texas 76011 J UE L

KMLNRC 84-053 Re Docket No. STN 50-482 Subj: Potential 10CFR50.55(e) Interim Report -

Reactor Coolant System Power Operated Relief Valve Relays

Dear Mr. Gagliardo:

This letter provides an interim report on a potential 10CFR50.55(e) concerning reactor coolant system power operated relief valve relays.

This matter was initially reported by Mr. H.K. Chernoff of Kansas Gas and Electric Company (KG&E) to Mr. Johns Jaudon of the Nuclear Regulatory Commission, Region IV, on March 2,1984.

A potential design deficiency has been identified concerning the activating relays (AR3XBB5, AR3XBB6) for the reactor coolant system power operated relief valves (PORVs) at Wolf Creek Generating Station.

The relay contacts, specified in the design do not have sufficient load interrupting capacity for the PORV control circuit. If contact failure should occur during operation, the affected PORV may not reseat properly. The design of these PORV control circuits is currently under evaluation.

The status of this potential 10CFR50.55(e) will be carried on the monthly stetus update as file 53564-K125. The final report or any significant new information will be submitted by separate correspondence.

In the interim, please direct any questions concerning this subject to me or to Mr. Otto Maynard of my staff.

Yours very truly, 8404090210 840330

/

/

DR ADOCK 05000 g

g GLK:bb xc:RCDeYoung F

Q WSchum 201 N. Market - Wichita, Kansas - Mail Address: PO. Box 208 i H6chita, Kansas 67201 - Telephone: Area Code (316) 261-6451 l lO I