GENERAL @ ELECTRIC ASBD-NDT 1101 l

coni en swer 2

en no.

1 og ng ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUAtlFICATIONANDCERTIFICATIONl CNOA 9.2 l

'. +.

PROCEDURE FIRST MADE FOR eens ou s=ur 2

en me.

i REVISIONS ASBD-NDT PERSONNEL TRAINING QUALIFICATION AND CERTIFICATION PROCEDURE NUMBER ASBD-NDT 1101 1.0 Scope h

1.1 Dis procedure establishes the requirements for the training, k

qualification, and certification of all ASBD personnel who are f

responsible for performance, administration or audit of Mondestructive Testing (NDT) for ASBD, General Electric Company.

g h

1.2 Dis pro'eedure has been designed to meet the requirements as a minimum, of the American Society for Nondestructive Testing b

Reconsnended Practice No, SNT-TC-1A, June,1975 Edition.

It describes the responsibilities and controls necessary to implement I

and administrate the ASBD-NDT personnel training, qualification and certification program.

1.2.2 ASBD-NDT, Schenectady, reserves the right to exceed the minimum requirements of SNT-TC-1A as specified herein in order to meet additional levels of skills and responsibilities for certain individuals in selected

{

methods.

2.0 Definitions

2.1 Qualification

Capability as indicated by skill, training and experience required for personnel to properly perform the duties of

-a specific job.

2.2 Certification

Written testimony of quali.fication based upon comparison to established standards of performance through written and practical examination.

i 2.3 Certification Agency:

ASBD, General Electric Company, Schenectady, shall e.yrtify ASBD-NDT personnel.

l

. 2.4 Experience:

We knowledge and skill derived from direct l

participation and observation in the performance of a nondestructive test.

+

(

3 9

~...

B404050310 840326 PDR ADOCK 05000373 G

PM 4

[yj

  • Otange ** Addition SfSl81 Pagps 1-2. 6 CRCA42 cco4 PRINTS TC ASBD on on ASBD-NDT 1101

_ awo

//.] "[*

Robert Smith


dyg-get.ay- - - _ * * " -

2 1

g

.u

_v.....:

m. :,;,;r '

gp 4

l l

3 c'

' GENERAL @ ELECTRIC ASBD-NDT 1101 E

A ME ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATIONI CNQA 9.2 l

h --

I~

PROCEDURE foanenemer 3

en me.

2 FIRST MADE FOR g.

REVISIONS

's

2.5 Training

The organized and controlled classroom and on-the-job training developed to impart the knowledge and skills necessary for gualification and certification.

s

2.6 Termination

when a certified individual is transferred to another k

division -within General Electric Company, or leaves employment of f

the General Electric Company.

c*2.7 Revocation: Rescind certification for failure to comply with amintenance requirements documented in this procedure.

3.0 Responsibilities

  • 3'.1 The Manager, ASBD-NDT, is responsible for the qualification and cert'ification of ASBD NDT personnel.

We responsibility ' includes assurance that the program described herein is implemented.

  • 3.2 De Manager, ASBD-WDT, shall be responsible for the appointment of NDT Level III examiner (s). The examiner (s) shall have been previously certified to Level III.

C*3.3 If the Level III examiner is not an employee of ASBD, General f

Electric Company, the certification must meet the requirements of I

l

~

this document. This shall be determined by the Manager, ASBD-NDT.

  • 3.4
  • The Level III examiner (s) for each NDT discipline shall provide guidance and direction for related training, qualification and certification for ASBD-NDT personnu.

Certificates shall be signed by the Level III examiner and the Manager, ASBD-NDT (Exhibit IV).

  • 3.5 ASBD-NDT personnel shall be responsible for recording all NDT work experience on the work experience record (Exhibit II). Such i

documents shall be forwarded *:o the ASBD-NDT ' headquarters in schenectady on a minimum of a bi-monthly basis.

3.5.1 Work experience will be included in the job summary on the

~

basis of when the data is received in Schenectady. The cumulative time will not be adjusted on the chronology of the work experience if the data is sent out of sequence.

l g, y,,

r

.1 i

o change ** Addition

)

PRINTS TO ASBD-NDI 1LOL mass er Roperc smita am0vaa ASBD w

- --- --- $1:h e.. w. dy---

2 3

/2/J///gy I. '" " *

  • tocation con,e saccr sei =0.

1 l

l C00t 30taf MO.

FF403Ce G.7el T

.I i

PRuefE)IN USA w n

c-l GENERAL @ ELECTRIC AsnD-NoT 1101 4

su no.

3 come on sass EE ASBD-NDT PERSONNEL TRAININCo E

A ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION lCNQA 9.2 l

PROCEDURE g

een, en once, 4

. en me.

3 FIRST MADE FOR

~~

REVISIONS 4.0 Nondestructive Testing Methods De Methods of testing which are specifically designated in this 4.1 procedure are:

(

4.1.1 Radiographic Testing (RT)

(

4.1.2 Magnetic Particle Testing (MT) 4-4.1.3 Ultrasonic Testing (UT) 4.1.4 Liquid Penetrant Testing (PT) 4.1.5 Eddy Current Testing (ET)

    • 4.1.6 Visual Testing (VT)

.w Y Y 5.0 Level of Qualification 5.1 Dere shall be three basic levels of qualification for each NDT

. method. Levels I and II have been subdivided to acknowledge necessary additional levels of skills and responsibilities.

NDT Level I-T (Trainee) - Ah individual in the process of being 5.2 qualified and certified to Level I.

  • 5.2.1 Level I-T meets education, training and examination requirements for applicable method but lacks minimum

['

  • experience requirements for Level I.

Imvel I-T may be certified to NDT Level I af ter obtaining experience requirements and a practical examination.

5.2.2 Level I-T shall work with or assist a certified Level II or Level III in the performance of a test.

Level I-T shall not conduct any test independently, interpret test results or write a report of test results.

5.3 NDT Level I 5.3.1 Level I individual meets education, training, examination and l

experience requirements for the applicable method.

  • 5. 3.2 Level I shall be qualified to perform calibration, examinations and record results in accordance with written procedures under the direct supervision of a Level II or III individual. Level I shall not interpret test results for the l

L purpose of evaluating acceptability of unsterials or 1

components, unless otherwise specified in the specific procedure.

  • Change ** Addition

[g l

IV~..i l

PRINTS TO l

ASBD-NDT 1101 man av nouert sattn annova6.

ASBD 3


schenveney--- aa-4 i

g, s2/n/ro a,

. w l

l g,g.y;;> '

4.

l

-.=

6EN ER AL @ ELECTilIC A$80-toi 1101 sa no.

4 est a s.sn 3

E 4

! TITLE f

ASBD-NDT PERSONNEL TRAINING, AS8D-TOT 1101 QUALIFICATION AND CERTIFICATION l CNCA 9.2 l

FIRsT MNENb i-a=, = mese 5

sa ao.

4 i-

~~

REvlSloNS O

5.4 ICT Level II g

5.4.1 Level II individual meets education, training, examination

$( '

and experience requirements for the applicable method.

w M

5.4.2 Level II shall be qualified to direct and perform calibrations and examinations, interpret, evaluate'and report 5.

test results for determining acceptability of materials and components in accordance with applicable codes, standards and J

specification. Level II shall be familiar with scope and limitation of the method and shall have a practical back-ground in applicable materials and fabrication processes.

$ t Level II shall be qualified to prepare written instructions and procedures subject to the approval of the responsible Level III and the Manager, ASBD-NDT. Level II shall be qualified to provide on-the-job training and direction of Level I-T and Level I personnel.

~

.~

5.5 NDT Level III and NDT Level III Examiner

5. 5.,1 NDT Level III meets education, ' xperience, training and C.

e examination requirements for the applicable method when

[),

certified by examination.

5.5.2 Level III shall be responsible for designating the particular test method and technique to be used and for interpreting, evaluation, and reporting test results for determining acceptability of materials and fabrication processes, and/or product technology, as well as familiarity with other NDT -

methods, to establish techniques and written procedures, and assist the design engineer in establishing acceptance criteria as required.

    • 5,5.3 Level III examiner shall have met the requirements of Level III in sections 5.5.1 and 5.5.2 above, or be certified by an outside agency and meet equivalent requirements as specified above.

S.

i

~::

l-

/

o thange ** Addition i

PRINTS To Robert Smith ASBD

    • a ASBD-NOT 1101 Schenict'ady"~~~.

5 sa...

4

~~

~ ~ ~ ~ ~

i e gggg-co.,

s m l

l g,=s.. -

g l

- ~...

.s um

9 GENER At @ ELECTRIC 3333.g37 1101 ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION l CNQA 9.2 l

.g FlEST MADb 3'

c g

ows *= s en 6

su me, REVISIONS 6.0 Education, Training and Experience Personnel being certified in nondestructive testing shall have N

6.1 sufficient training to insure understanding of the principles and procedures in those NDT methods in which they are being considered q

Q for certification.

G %

k).L "k

Personnel shall complete organized classroom training in accordance

  • 6.2

(

with ASBD-NDT training courses.

a g

The Education and Dnployment Record Form shall be used to record the 6.3 information required by 6.1 and 6.2 above (Exhibit I).

y y

Training course for ASBD-NDT personnel shall be conducted by Level

  • 6.4 II or Level III ASBD-NDT personnel or bh recognized NDT schools within or outsida the General Electric Company. These training courses must -have prior approval of the Manager, ASBD-NDT.

6.5 On-the-job training should be used' to augment formal classroom training.

(

6.6. Education opticns for Levels I-T, I, and II 6.6.1 Option 1:

Successful completion of at least two years of college engineering or science study..

6.6.2 Option 2:

High school graduation, diploma or equivalent.

6.6.3 option 3:

Crammar school graduation or demonstrated proficiency or additional training.

~

6.7 Work experience options for Level III:

Craduate of a four-year accredited engineering or option 1:

6.7.1 science college or university with a degree in Engineering or I

science plus one year's experience in nondestructive.

examination in an assignment comparable to that of an NDT Level II in the applicable test method.

If the college or university degree is issued in nondestructive testing, the l

one.,' year's experience requirement may be reduced to six

,]

~

i l

months.

I l

I

[

  • Change ** Addition PRINTS Tt
    • on ASB:*-NDT 1101 ASBD Robert Smith

un.

l

...- -... -- - - - - d y 5

Schenecta

,,, m y g 1

F isawso e,::,w 4

I

GENERAL @ ELECTRIC ASBD-NDr 1101 7

6 en sacar

= no.

TITLE ASBD-NDT PERSONNEL TRAINING, A

ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION l CNQA 9.2 l

. PROCEDURE y

s= m 7 na me.

6 FIRST MADE FOR REVISIONS Option 2: Completion with a passing grade of at least two 6.7.2 years of science study at an accredited university, college i

or technical school, plus two years experience as a certified NDT Level II in the applicable test method.

b lu

  • 6.7.3 Option 3: Four years experience as..a certified NDT Level II I k in the applicable test method.

~%

  • 6.8 Training and experience requirements. Work experience is considered

. g to include all the time associated with performing an NDT h

inspection.. This includes time spent in preparation for testing, in for discussion and specific task

. procedure and technique ' review, instruction, during actual test time, for post-test clean up, and

' N-Y Y for reporting and record keeping. This does not include training

. time, which is a separate requirement, nor does it include travel time to the job site. Work experience shall be recorded as hours of experience on the NDT individual time report (Exhibit II).

  • 6.8.1 NDT Level I T (Minimum Training and Experience)

I Work Method Option 1 Option 2 Option 3 Experience Ig gs RT 12 Hrs.

20 Hrs.-

80 Ers.,

  • O Hr's.

MT 8 Hrs.

12 Hrs.

24 Hrs.

O Hrs.

UT 24 Hrs.

40 Ers.

40 Hrs.

O Hrs.

PT 4 Hrs.

4 Hrs.

12 Hrs.

O Hrs.

ET 8 Hrs.

12 Hrs.

48 Hrs.

O Hrs.

VT 4_ Hrs.

4 Ers.

12 Hrs.

0 'Mrs.

f O Change ** Addition PRINTS To ASBD-NDI 1101 sinos et Robert Smith annovass ASBD 6


1chenect ady--- *"-

7

= ne.

seem ee n o

=rts

/2/,7f/po

ur:.=

t

.l l

~' -

\\

GENER AL @ ELECTRIC ASBD-NDT 1101 g

4 TITLE 8

7 ASBD-NDT PERSONNEL TRAINING.

ASBD-NDT 1101 QUALIFICATIONANDCERTIFICATIONI CNQA 9.2 I

FIRST MADb h

8

= no.

een, en REVISIONS
  • 6.8.2 HDT Level I (Minimum Training and Experience)

Work Hathod Option 1 Option 2 Option 3

, Experience RT 12 Hrs.

20 Hrs.

80 Hrs.

All Options: k 525 Hrs.

Q HT 8 Hrs.

12 Hrs.

24 Hrs.

All Options:

175 Hrs.

UT 24 Hrs.

40 Hrs.

40 Hrs.

All Options:

525 Hrs.

PT 4 Brs.

4 Hrs.

12 Hrs.

All Optio'ns:

p 175 Hrs.

ET 8 Hrs.

12 Hrs.

48 Hrs.

All Options:

  • 175 Hrs.

VT 4 Hrs.

4 Hrs.

12 Hrs.

All Options:

175 Hrs.

p

~

(-s j.

  • Change ** Addition s

PRINTS TO ASBD en on ASBD-NDT 1101

=^** *T Robert Smith

~ ~ ~~~~ ~~ 'e~c~taE~~~~

8 7

S hen g

p

.uwto rr e -- e u-rei J.

l l

coot icrav =o.

_m.*

- he ' -

  • j,*.

]-

' ' GENERAL @ ELECTRIC ASBD-NDT 1101 I

0

    • ""'""'T TITLE A5BD-NDT PERSONNEL TRAINING.

ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION l CNQA 9.2 l

(,(,!

PROCEDURE esat om set, 9

== =o.

8 FIRST MADE FOR v

REVISIONS

  • 6.8.3 NDT Level II (Minimum Trsining and Experience) pb work Method Option 1 Option 2 Option 3 Experience T

v

-4 RT 40 Hrs.

40 Hrs.

100 Hrs.

All Options:.

,g 1575 Hrs, g g tu MT 4 Hrs.

8 Hrs.

16 Hrs.

All Options:

Y. k 525 Hrs.

UT 40 Hrs.

40 Hrs.

80 Hrs.

All Options:

1575 Hrs.

O PT 4 Hrs.

8 Hrs.

16 Hrs.

All Options:-

350 Hrs.

{,

ET 8 Hrs.

8 Hrs.

24 Hrs.

All Options:

1575 Ers.

VT 4 Hrs.

8 Hrs.

16 Hrs.

All Options:

350 Hrs.

r

+.. ~ ~ _.

~

0 Change ** Addition-(,

PRINTS TO

~

maos s' Robert Smith amovau ASBD Absu-NUL L101


Setrene c tady--- **"-

8 r

.wa, /2./J//fo 9

= no.

tocate= coar en cri mei-j 4

l l

.o.....=,...

.. _ =,., - __- _;

3 GENERAL h ELECTRIC

e ASBD-NDT 1101 cow,en ents' 10 ' " " * -

9 ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101

' h, QUALIFICATION AND CERTIFICATION l CNOA 9.2 l

PROCEDURE

,f/

,,,,,,,,,,,,, 10 g

FIRST MADE FOR REVISIONS

  • 6.8.4 NDT Level III (Experience options outlined in Paragraph 6.7)

Method Option 1 Option 2 Option 3 k

to R

RT 2100 Hrs.

4200 Hrs.

8400 Hrs.

(

MT 2100 Hrs.

4200 Hrs.

8400 Hrs.

'k N

UT 2100ifrs.

4200 Hrs.

8400 Hrs, h

PT 2100 Hrs.

4200 Hrs.

8400 Hrs.

t, ET 2100 Hrs.

4200 Hrs.

8400 Hrs.

~

VT-2100 Hrs.

4200 Hrs.

8400 Hrs.

4-

  • 6.8.5 The training and experience listed on chart 6.8.3 shall consist of time at level I.

For exceptions to the normal progression from trainee to certification as Level II, the overall requirements of training and experience are the sum of hours on charts 6.8.2 and 6.8.3.

Two typical exceptions include, individuals who have been involved in NDT prior to a formal NDT program, and individuals who have had more than l

the required time at Level I-T before certification to I-Level I.

l

  • 6.8.6 Under special circumstances, credit for experience may be gained simultaneously in two or more disciplines. The candidate must spend at least 25% of the work time on each discipline for which experience is being clained.

Furthermore, this similar testing must meet the 25%

requirement during each calendar veek. These special circumstances must be reviewed and approved in advance by the Manager ASBD-NDT or the Level III Examiner.

f* '

  • Change ** Addition

~

\\...

PRINTS TO

"**8

Robert Smith ASBD

    • oa ASBD-NDT 1101

,.....---------.---een.

~

M

/J./g//gp Scheneetady 10 9

u,e,

co,..,. cc, n

...'4 6, A

l

[

a

.r--*--~--

ggO@@(jl g kLtC1 HIC ASBD-NDI 1101 E

TITI.E ASBD-NDT PERSONNEL TRAINING.

.e 11 ' " " ' '

10 QUALIFICATIONANDCERTIFICATIONl ASBD-NDT 1101 PROCEDURE CNQA 9.2

]

(.Q to 11 FIRST MADE FOR

.e

eau, e.

REVISIONS 7.0 Examinations

  • 7.1 An NDT Level III Examiner cr his selected representative shall conduct and grade examinations for all NDT Levels 1-T, I, and II.

Q An NDT Level III Examiner shall conduct and grade examinations for g

candidate NDT Level III individuals. Written examinations shall be administered in accordance with paragraphs 7.1.2 and 7.1.3 of this q

procedure.

If the number of questions exceeds the minimum required

+

mumber, the allowable test time is increased proportionally.

ig N

  • 7.1.1 Physical:

All NDT personnel shall meet the vision requirements specified herein both as a prerequisite to training, qualification, and certification and as a

%g continuing requirement. Eye screening shall be performed at least annually by a qualified individual approved by the Manager ASBD-NDT. Eye screening results shall be recorded on Form NDT-F-102 Exhibit III and kept on file.

  • 7.1.1.1 visual uity (Uncorrected or corrected): The Jaeger No.1 Chart shall be read from a distance of 15.7 inches, plus or minus 1 inch. This requirement is for monocular as well as binocular vision. The ability to perceive an Ortho-Rate minimum of eight h.

or similar test pattern shall also be accpetable.

)

g

  • 7.1.1.2 Color Vision:

Personnel who are certified in MT, PT or other test methods requiring color discrimination shall pass a suitable color discrimination test such as that dictated by the Ishihara or American Optical

  • Color P1ates.

i l

?

Q,'...

~

O Change ** Addition l

l f.

PRINTS TO

= ass av Robert Smith ASBD

="

ASBD-NDT 1101

............__ __- - _- u n.

.asvu ggg Schenectady 11 10

..,,o.

f l

l pr.eos.we no.vei cut iocat ao.

PepITED M USA.

---g---"--***-

~-

.'.i.

~:

GENERAL @ ELECTRIC ASBD-NDT 1101 12 11 u,

ME ASBD-NDT PERSONNEL TRAININC, ASBD,NDT 1101 QUALIFICATION AND CERTIFICATIONl CNQA 9.2 l

[, $)

PROCEDURE 12

.= ne.

11 FIRST MADE FOR son, em.=n REVISIONS,

  • 7.1.1.3 Exceptions: When the requirements of Paragraphs 7.1.1.1 and 7.1.1.2 above are not met, the

- s individual shall be examined by a licensed vision

{

care practitioner. The information contained in 7.1.1 shall be made available to the practitioner and shall include a description of the NDT H

disciplines in relation to visual acui,ty and color g

discrimination.

After examination of the individual

'(

in question, the practitioner shall document his judgment as to the individuals' capability to g!

recognize the necessary patterns, including any s

N restrictions deemed pertinent. Such documentation shall form a part of the individual's permanent Y Y record.

Di's process for questions on color vision.

paragraph 7.1.1.2, is a one time requirement unless

', - the work scope adds additional color discrimination.

  • *7.1.1.4

%e eye screening is detailed in a separate procedure of ASBD-NDT procedure manual, Volume 29, 7.1.2 Ceneral

  • 7.1.2.1

% e general examinatica shall cover basic theory, principles, and practices relative to the applicable i

NDT method. This examination shall be administered without access to reference material (closed book) except that graphs, tables and other necessary data may be used.

l

(

7.1.3 Specific L

  • 7.1.3.1 h e specific examination shall cover equipment, operating procedures, test techniques, and codes that the examinee may encounter in specific assignments.

This examination shall be administered as an open book test..

r t

t

  • Change ** Addition PRINTS TC maos av KoDert setth arraow u A5BD ASBD-NDI 1101

mecurny--- ="-

11 l y

.... a./w /fo 12

-,,o.

co,.. u, 1

l n

.... ~,6, 4

i i

=

_:_,._:.w _

L.

L;w_ :L

.3

' SENER AL @ ELECTRIC ASBD-NDI 1101 l3 12 e2 3,' TITLE ASBD-NDT PERSONNEL TRAININC, j

ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION]

CNQA 9.2 l

h-(

PROCEDURE eenen en 13 no.

12 FIRST MADE FOR REVISIONS 7.1.4. Practical

  • 7.1.4.1 The person considered for certificaion shall sg l

demonstrate to the satisfaction of the NDT Level III A

l Examiner or his representative that he is familiar

% ('

with an can operate the necessary test equipment and 4" y analyze the test results to the degree required.

  • 7.1.4.2 At least one selected specimen shall be tested and 9

interpreted by the examinee. However, test

(%

interpretation is not a requirement for g

certification for NDT Level 1-T or NDT Level I.

N iu Y

Y

  • 7.1.4.3 The description of the test specimen, test procedure, check points and resulta of examination shall be graded and documented.

7.2. NDT Level I-T and',NDT Level I Examination D

7.2.1 General Examination:

The minimum number of questions and

  • related allowable test time for. each NDT method shall be as

{.

follows:

Number of A11o'wable W

Test Method Questions Test Time Radiographic Testing 40 1If2Mrs.

Msgentic Particle Testing 30 1 1/2 Hrs.

Ultrasonic Testing 40 1 1/2 Hrs.

Liquid Penetrant Testing 30 1 1/2 Hrs.

Eddy Current Testing 30 1 1/2 Hrs.

w s.

j Q Change ** Addition

(,

}

PRINTS T0 maec ev Robert Satch arraowau ASBD A55D-NDI 1101

,, e.


9thenectwdy--- '"-

12 e

/2/J//fo 73 a toen cowon =m sa ao.

==& > '

t

.I l

a-m.

e--um,y*

+ -,-..-

-w---w

-,.%w,w+-&

b w-.=+*-w*.-*

a v r

.'...'......:.......a..........~_......._._._.__

1

~

GENERAL @ ELECTRIC AsnD-NDr 1101 14 13 en.

coat en ccr TITLE ASBD-NDT PERSONNEL TRAINING, T

QUALIFICATION AND CERTIFICATIONI CNQA 9.2 l

ASBD-NDT 1101 PROCEDURE

.. v en er, 14' en me.

13' FIRST MADE FOR

'5 REVISIONS Specific Examination: The minimum number of questions and related allowable test times for each NDT method shall be as

'7 2.2 s

I follows:

Number of Allowable

~ Questions Test Time Test Method 20 1 1/2 Hrs.

Radiographic Testing 20 1 1/2 Hrs.

Magentic Particle Testing 20 1 1/2 Hrs.

tiltrasonic Testing 20 1 1/2 Hrs.

g 1.iguid Penetrant Testing 20 1 1/2 Hr.,

Eddy Current Testing Proficiency shall be demonstrated in Practical Examination:

  • 7.2.3 performi'ng the applicable nondestructive examination and evaluation of the results obtained on one or more samples approved by the NDT Level III Examiner or his At least ten different check points representative.

requiring an understnaidng of test variables and procedural requir'ements shall be included in this practical examination.

e I4 7.3 NDT Level II Examinations 7.3.1 General Examination: The minimum number of questions and time for each NDT method shall be as i

related allowable test follows:

Number of Allowable Questions Test Time Test Method 40 2 Hrs.

Radiographic Testing l

30 1 1/2 Hrs.

Magentic Particle Testing l-40 2 Hrs.

Ultrasonic Testing 30 -

1 1/2 Hrs.

Liquid Penetrant Testing 30 1 1/2 Hr.

Eddy Current Testing t Change ** Addition

( '

PRINTS TO, A550-hDI 1101 A550 a av nopert smitn annovass 13


9chenn i h -- ','"-

14 sa ao.

see4 ion co, on s cce

/J./F///O p.n

GENER AL @ ELECTRIC ASBD-NIrr 1101 e"

co"' *" *"* "

15

.a no.

14 TITLE ASBD-NDT PERSONNEL TRAINING,

-ASBD-NDT 1101 QUALIFICATION AND CERTIFICATIONI CNQA 9.2 l

(.

PROCEDURE c--

een,en e.c, 15 14 FIRST MADE FOR R

REVISIONS

  • 7.3.2 Specific Examination: The minimum number of questions and related allowable test times for each NDT method shall be as s

follows:

s

)

Number of Allowable Test Method Questions Test Time k (

y x Radiographic Testing 20 1 1/2 Hrs.

k g

Hagentic Particle Testing 15 1 nrs.

'q O

Ultrasonic Testing 20 1 1/2 Hrs.

Liquid Penetrant Testing 15 1 Hrs.

Y Eddy Current Testing 20 1 1/2 Hrs.

  • 7.3.3 Practical Examination:

Proficiency shall be demonstrated in

' selecting and performing the applicable nondestructive examination and evaluating the reus1ts obtained on one or i

more samples approved by the NDT Level III Examiner. At least ten different checkpoints, requiring an understanding of test variables and procedural requirements shall be included

-.--)

in this practical examination.

4

  • 7.4 NDT Level III Examinations t.

{

Note: All Level III candidates must satisfy the following y

examination requirements. Level III examiners shall be appointed by the Manager, ASBD-NDT, af ter having met the requirements of Level III.

See. paragraph 5.6.3.

7.4.1 ceneral Examination: A minimum of 30 questions devised by the Examiner on the NDT method to be certified, plus 30 NDT

{

Invel II questions for other applicable NDT methods.

t j

7.4.2 Specific Examination:

'Ihe minimum number of question and

- related allowable test times for each NDT method shall be as follows:

v N.

O change ** Addition g.

PRINTS TO

= ass ev Robert Smith

    • rsome ASBD ASBD-NDT 1101 m e.

.....- gg g g -- otrt.

14

" /2[.Y/

15 O

acanom coat om satp FF.103CBsto 788 '

A l

l Coot sotut no.

T I

i pa:Tes as usa.-

._m..._

f GENERAL @ ELECTRIC' ASBD-NDT 1101 15

    • "' *" *"tcr 16 arv TITLE ASBD-NDT PERSONNEL TRAINING, ASBD,HDT 1101 QUALIFICATION AND CERTIFICATION l CNOA 9*2 l

PROCEDURE 16 sa me.

15 FIRST MADE FOR

.'[

oomt ou sacer REVISIONS Number of Allowable Test Method Questions Test Time sg Radiographic Testing 20 1 Hr.

AL to Magentic Particle Testing 20 1 Hr.

g 20 1 Hr.

j Ultrasonic Testing

, Liquid Penetrant Testing 20 1 Er.

Ak b

^

h Eddy Current Testing 20 1 Hr.

k

  • 7.4.3 Practical Examination:

Proficiency shall be demonstrated in selecting, specifying and writing specifications and/or procedures for the performance of the applicable mondestructive examination using appropriate reference material. We proficiency shall also be demonstrated by performing and evauliting the results on one or more samples approved by the NDT Invel III examiner. At least 10 different checkpoints requiring an understanding of test variables, and procedural requirements shall be included in this portion of the practical examination.

    • 7.4.4.

If the Level III candidate has been certified by examination administered by the America Society for Nondestructive Testing (ASNT), the general examination does not need to be administered.

7.5 Crading

The NDT Level III Examiner shall be responsible for the conducting and grading of examinations of all NDT personnel. The actual administration and grading of examinations m:y be delegated to the duly selected representative of the Level III Examiner and so recorded.

7.5.1 Minimum required percentile grades for NDT Levels I-T, I, II and III are detailed in Paragraph 7.5.2.

These grades shall be a composite grade based upon the general, specific and practical tests as weighed in Paragraph 7.5.3.

i l

i g*

  • Change ** Addition PRINTS TC ASBD-NDT 1101 ames av Robcrt Smith arraove ASBD

.. --..SthtN EW -- **"'

15 16 sn no.

tocenon come on satte

/

/

O j

i i

...w. s.,

I I

e,.

h

~~ t 2

.s.

4

-o.

.p e-w

SENER AL @ ELECTRIC ASnD-NDT 1101 17 10

    • ""'"8

so TIRE ASBD-NDT PERSONNEL TRAINING, A

ASSD,NDT 1101 QUALIFICATION AND CERTIFICATICNl CNQA 9.2 l

(-(,-

PROCEDURE 17 en me.

16 FIRST MADE FOR esas en enerv REVISIONS O

  • 7.5.2 Examination for NDT Levels I-T, I, and II requires a s.

composite grade of 80% or greater.

In addition, each grade for the general, specific and practical examiations shall be 70% or greater. Test objects shall be used in the prac.tical examinations of NDT Levels I-T, I and II and at least 90% of N

the known indications shall be found. For NDT Level III, a o

composite grade of 90% is required and no grade shall be less

(,*

than 80%.

If the ASNT Level III examinations have been passed, the minimum grade, 80%, will be used for the general o

examination.

N 7.5.3 A percentile weight factor shall be applied to the percentage grades of the various examinations. The percentile weight Y

k assigned any particular examination shall be as listed. -

below. The total of _ the three percentile weights shall equal 1.0.

  • 7.5.3.1 NDT Level I-T and I, Examination Grades 1.

General

-0.5 2.

Specific

-0.2

{-

3.

Practical

-0.3

  • 7.5.3.2 NDT utvel II, Examination Grades 1.

General

-0.3 i

2.

Specific

-0.4 3.

Practical

-0.3

  • 7.5.3.3 NDT Level III Examination Crades 1.

General

-0.4 2.

Specific

-0.4 3.

Practical

-0.2

  • 7.5.3.4 The composite grade (cc) is deterined as follows:

Cc= (Cg x Wg) + (Gs x Ws) + (Cp x Wp) r i.

,., m.

C Change ** Addition f-

' PRINTS TO ASBD-NDI 1101 ASBD w.m aa*. sv Robert Smith aceewe 16


Schitnecruty--- **"-

17

/2./J/[fo w ear a cour on sutti see wgg.,

{

j

.j

.~3,,~-.-~---

~

=-

SENER AL @ ELECTRIC ASBD-NDT 1101 17 I8 cone ou :=act E

ME ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION l CNOA 9.2 l

PROCEDURE T*

18 sw me.

17 FIRST MADE FOR soar em =en REVISIONS i

Where:

s Oc = Composite grade Cg = Actual grade from general examination in percent k

Ug = Percentile weight of general examination Cs = Actual grade from specific examination in percent Ws = Percentile weight of specific examination

( +

Cp = Actual grade from practical examination in percent Up = Percentile weight of practical examination y

g

  • i.5.3.5 Example:

1.

Test results obtained for Level I examination General (Cg)

= 87%

Specific (Cs)

= 93%

., Practical (cp) = 90%

2.

Percentile weight assigned for each examination General (Wg)

=03

[

Specific (Ws)

= 0.4 Practical (Wp) = 0.3 1.0 3.

'Iben:

Ce = (87 x 0.3) + (93 x 0.4) + (90 x 0.3)

Ce = 26.1 + 37.2 + 27.0 Ce = 90.3%

7.5.4 Re-examination

Those failing to attain the required grades must wait at least 30 days and/or show evidence of having received suitable additional training, as determined by the NDT Level III Examiner.

7.5.5 Additionally, all written exams shall be generated by the Manager, ASBD-NDT or the level III Examiner and shall be controlled such that they are available to other NDT

~

personnel only as required while NDT personnel are being examined.

6...

z[

  • Change ** Addition 4

PRINTS TC A5BD-NDI 1101

.aos av Robert Smith aream A5BD 17

schneet ady--- "-

18 gE.nuce

,,,,,o.

/

iment.o. co=, o= s <c,

  1. ,jU /O 7 /

l

_l

__ TN 2 '* * ", ' ",

.,h coee ec=, =c

. m

GEllER AthELECTRIC ^

AsBD-tiDT 1101 Fe' a

TITLE 19 18 ASBD-NDT PERSONNEL TRAINING, i

ASBD-POT 1101 QUALIFICATION AND CERTIFICATION l CNOA 9.2 l

FIRST MANEN een en saca - 19 m me.

REVistoNS 8.0 Certification

'8.1 Certification of all NOT personnel is the responsibility of the Manager, ASBD-NDT with approval by NDT Level III Examiner'.

b 8.2 Certificion of NDT personnel shall be based on demonstration of Y

satisfactory qualification as determined by procedures outlined in g

Paragraphs 6.0 and 7.0.

8.3 On the basis of ability, achievement, education, training, and experience, as described in Paragraphs 5.5 and 6.7, the

,k certification by examin'ation may be waived for the ICT Level III O

individual.

However, in such cases, the Letter of Appointment by

,the Manager, AS9D-NDT, shall state that certification was e

established without examination.

Written certification and evidence' supporting the certification shall be held in the ASBD-NDT, Schenectady Office and made available when vertification is required.

8.4 At the option of ASBD-NDT, Schenectady, an outside agency may be engaged to provide NDT Level III services.

In such instances, the reponsibility of certificaion shall be retained by ASBD-NDT, Schenectady.

(~,')

e 8.5 ASBD-10T, Schenectady, shall be responsible for auditing the outside

. agency providing NDT Level III services to assure that their training examination and certificaton procedures are in accordance with this document. A written record of the audit shall be maintained at ASBD-NDT, Schenectady.

'8.'6 Dertification records shall be kept on file in the ASBD-NDT, Schenectady Office. The certification records shall consist of the following:

i

'8.6.1 Education and employment record, Form NDT-F-106 (Exhibit I).

  • 8.6.2 Individual NDT work experience record, Form DOT-F-103 (Exhibit II).

'8.6.3 Vision Tests, Form NDT-F-102 (Exhibit III).

~~ :.

'W Change ** Addition l PRINTS To

~~

Robert Smith

,,,,,.,,__ASBD,,,,,,,,,*"J ASBD-NDT 1101 l

/2/gf/fo Schenectady usation coat on w rv 19 > ao.

18

' EIo"EN' '

f l

l

.o

8ENER AL @ ELECTRIC '

ASBD-NDT 1101 ME cut on sam 20

s..

19 as e

'86 ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATIONANDCERTIFICATIONb CNOA 9.2 l

_[%,

PROCEDURE M/

20 eene ea := m su m 19 FIRST MADE FOR REvistONS

  • 8.6.4 certificate of Qualification, Form NDT-F-104 (Exhibit IV.)
  • 8.6.5 Formal Training Certificate, Form NDT-F-105 or a classroom s

training certificate from an approved non-ASBD school, k

(Exhibit V).

lu

  • 8.6.6 Documents showing the results of practical exams,, including descriptions of items tested.

t

  • 8.6.7 copies of current examinations and grades of previous Q

examinations.

A

\\W 8.7 Re-Certification 8.7.1 All levels of NDT personnel shall be re-certified at least once every three years in accordance with the following criterii:

  • 8.7.1.1 Evidence of continuing satisfactory performance.

['

  • 8.7.1.2 Re-examination in accordance with Paragraphs 7.0 and A-8.0.

+

4

  • 8.7.1.3 Upon re-certification a 104 form is issued t-(Exhibit IV).

t 8.7.2 NDT personnel may be re-examined any time at the discretion of the NDT Level III Examiner and have their certification extended or revoked.

7

~~ ?:' -

~.

l l

f C Change ** Mdition k.. y PRINTS TO

- M sv Robert Smith arenovats ASBD A5BD-NDI 1101 mm lE


sctane c t ady--- *"-

19

  • * * * * /2/J///o 20 men,.o=

co, o ar, es m we'e en A

a s'_

... ~ ~.

l l

eene inca, no

'~:-

' * * ~

LT K

GENERAL @ ELECTRIC AsBD-NDT 1101 20 21 sa sio.

eent on enter

  • E ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATI0l CNQA 9.2 1

{, ;,..

PROCEDURE ea an.

20 FIRST MADE FOR 21

'n sont eu sees, REVISIONS 8.7.3 NDT Level I and II personnel who have not been actively h

engaged in 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> of nondestructive testing activity per certified discipline for a period of six months shall require g 4

%qNk{

re-examination and re-certification. Re-examination shall be The accomplished by administering a practical examination.

N m

I individual must score a minumum grade of 80% on the k

k examination to be eligible for re-certification.

\\o %

8.8 Revocation of Certification l

8.8.1 he Manager ASBD-NDT shall revoke the certification of any S

individual:

e Y,$

  • 8.8.1.1. whose certifications in any given NDT method have expired.
  • 8.8.1.2 whose eye examination has expired.
  • 8.8.1.3 who meets the requirements of Paragraph 8.7.3 l

above.

j-

  • 8.8.1.4 who is judged to lack evidence of satisfactory performance.

4 Acceptance of NDT Certifications from Other General Electric Company 9.0 Components 9.1 Individuals holding current NDT certifications from other Ge eral Electric components may be certified by ASBD-NDT, Schenectady, without re-examination provided the D110 wing criteria has been met:

9.1.1 Documented evidence of prior certification is presented and approved by the Manager, ASBD-NDT.

i De individuals have been actively engaged in nondestructive l

9.1.2 examination within the last six months, in their applicable certification.

he NDT Personnel Qualification and Certification Program 9.1.3 from the General Electric component issuing the certification i-

  1. meets the. requirements of SNT-TC-1A, and satisfies the intent of this procedure as determined by the Manager, ASED-NDT.

(

o change ** Addition PRINTS TO ASBD-NDI 1101 meet av Robert Satch aremova6s A5BD 20


Schenecendy---

88"-

21

~~

tocation coat on enact e -... [2-/8/

d coot notat ao-f, pr<os we no-?si

. _ y mrto a us { --

__9_

GENER AL @ ELECTRIC-AsBD-NDT 1101 22 sa no.

21 cour on sacc, me, TITLE ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATIONI CNOA 9*2 l

PROCEDURE

.h 22 21 FIRST MADE FOR sent on saccr sa no.

REVISIONS 10.0 Acceptance of NDT Certifications from Other Companies

  • 10.1 Individuals holding current NDT certifications from other

'A companies may be certified by ASBD-NDT provided all of the

'L following criteria have been met:

10.1.1 Documented evidence of prior certification is presented and approved by the Manager, ASBD-NDT.

%(

10.1.2.. Satisfactory completion of the general, specific and practical examiations for the method in which certificaton S

is to be given.

g 10.1.3 De NDT certification program from the company meets the requirements of SNI-TC-1A and satisfies the intent of this procedure as determined by the Manager, ASBD-NDT.

~

10.1.4 De individual was actively engaged in the methods to which he is being certified at ler.st six months prior to his termination.

10.1.5 The individual is being certified within six months of his termination.

+

11.0 Termination 11.1 All certifications shall be automatically terminated when an employee leaves the Apparatus Service Business Division.of the General Electric Company.

Approved by: ~ William J/jLe aiih,

/

.m i

j'.

Manager <%SBD-NDT y

4 David B. King Q 1Avel III Examiner

~

c f**

  • Change ** Addition l

PRINTS TO

_not av nocept smitn aersoms A5BD ASBD-NDT 1101 21

/2/1//74


sch e rrecraty--- ','"'

22

,pg.mco a ea.o.

co., e. s.<r, sa ao.

l

.._.___...r '

a' ' a a A

..I

~m n="

m

GENER AL @ ELECTRIC ASBD-NDT 1101 23 22

?

cow on succ, en.

TITI.E ASBD-NDT PERSONNEL TRAINING, me.

ASBD-NDT 1101 QUALIFICATION AND CERTIFICATIONj 9*2 l

PROCEDURE g

Ig een, en one, 23 22 FIRST MADE FOR t

REVISIONS 1

~

CDIERAL ELECTRIC COMPANY

. Q AFFARAIUS SERTICE BUSINESS DIVISION IDUCATION AND DeLOYMENT RECORD RANE JOB TITLE DAIE h

30 1

1.~ EDUCATIDit SCB00LS, COLUCES, AND NDT COURSES g

MANE AND LOCATI0tt OF SCHOOL DATE TYPE OF COURST.

50. OF GRADE BOURS COMPLETED g

n Y

1 II. NDT CERTIFICATION (5)

COMPANY METHOD LEVEL BY TEST CODE OR SPEC.

DATE REC'D YES NO 4

am a

~

i III. MDT EIFERIENCE JOB TITLE WORE FRIORNE FROM To e_

va.

Mo.

YR.

~

f.

EDT.F-106 ExgIBIT I PRINTS TO A5BD-NDI 1101 Mass av.

hw^vs a 6 5mi6u

. _;.us Ahnu


--- Scirettectady --- *-

22 23 sn...

e

/J./J//fp ummon co=,om saccr P'

,r4 3 4.

f.,

4 l

l co. ie< > a.

n.

~%

.,.-q-e

j

,s e'

f I

Li:1 l

E

> @ memn$"

ga8-o*

t g l

.An 4

5

. m y=N MNozi s5;-

5

,e s

l i

o.c lhnE gaa b csEF nz

.'~

g.ygs caw a

wW w 0h t

~

mi a

[: I5 IJ

=D s

i L

g, ~

=E a

s

=54$

O e m E = =M

  • ': m Vm eqE-S f
g<

c" b 6d=" 2!) aE%M" a

at

/

Y zg-

,I Q

~

3 5"1< pgo 2l f

Wi \\=5-c i

mq

'H U

t

, ~"^

T 6

s tA a

M e f

=$

, cm n

U y

S 0

c I

gm ag * ] m=

0 V

h V ~C$/Y

  • Nk l

d j

1

~.

! ' e,m9

\\

/

sgG.g. AE sgG. 5;Gn" O g.M "n

ayG.- a2G" <&p N=

M

/

i n g? E -

t*

$.4n'S>*g

>E

,2 i

3 sR f li M*

!l u$43\\

l9 g"

I5 y-

~

?.

9 e.

=$k;c 2~

5

. e 1

ei i

. lJ. : ' :

t t'

I.'

' GENER AL @ ELECTRIC ASBD-NDT 1101 ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION l CNQA 9.2 l

g (f.g PROCEDURE FIRST MADE FOR u,

25 96 REVISIONS GENERAL ELECTRIC COMPANY APPARATUS SERVICE BUSINESS DIVISION EYE TEST CERTIFICATION L

4 Name Pin Number

. Location Da'te v

(r4 T:st Without Glasses _

1.

(Cover left eye)-

Right' Eye Chart No.

%.g 2.

(Cover right eye)

Left Eye Chart No.

3.

Both Eyes Chart No.

Tnst With Glasses (If Applicable)

If bif,ocal, use lower set of lenses.

1.

(' Cover left eye)

Right Eye Chart No.

~

2.

(Cover right eye)

Left Eye Chart No.

A 3.

Both Eyes Chart No.

Color Vision The following color discrimination test has been administered in accordance with the specific instructions accompanying the test.

S. Ishihara O ^=erican optical I certify that the above individual has been given the above eye tests and has/has not met the Jaeger No. I requirement and has p'assed/ failed the indicated color vision test.

Comments:

f Signed Title Date Note: These tests compry with the American Society for Nondestructive Testing Recommended Practice No. SNT-TC-1A, June,1975 Edition.

l 1

f l

NDT-F-102 EXHIBIT III

'1 PRINTS TO Robert Smith ASBD sw ea ASBD-NDT 1101

-~~~ ~


- mtasy 25 24 sehe x

toe,.o-co, a s~n, s.<

o-n/31/9o emg-;.,

4

,j

.l

m...

c GENER AL @ ELECTRIC AsBD-NDT 1101 26 25 c,

  • E ASBD-NDT PERSONNEL TRAINING, ASBD-NDT 1101 QUALIFICATION AND CERTIFICATION l CNQA 9.2 l

t PROCEDURE

!6.

so=,

cc, 26

.=

25 FIRST MADE FOR Q')

REVISIONS GENER AL h ELECTRIC

^ " ^ " ^ * -

SERVICE s

D8 VISION sensnAL suctac coeAPANY. oNE AlvtR ROAD. SCNENECTADY. NEW Yonet tasas L

et (sien ass.arti v

nu l

R CERTIFICATE OF QUALIFICATION hg E

THIS IS TO CERTIFY THAT 4 g is qualified in accordance with the ASBD-NDT Training, Qualification and Certification Procedure No.1101 which complies with the requirements of the American Society for Nondestructive Testing Recommended Practice No. SNT-TC-1A (June 1975 Edition). Certification is based on background, training, examination and evaluation of experience and f.

performance in the NDT method indicated.

M NDT Method Level Date Expires Examination Results Test Scores Weight Pr'oduct

=

General -

X X

=

Specific -

=

Practical -

X 4

Composite Grade j*,CertifiedNDTLevelIIIExaminer*

Date j

L Manager, Nondestructive Testing Date EXHIBIT IV NDT-F-104 PRINTS TO

        • sv Robert Smith
    • aome ASBD ASBD-NDI 1101

Tchu s c ritfy--- "-

25 26

s....

pg

,s. - /2/.Jf/f a sacation coat on sacc, l

l

,, n.. r

.t'ei coociocar.e

GENERAL #fe ELECTRIC-ASBD-NDT 1101 E

~^ '

TITLE

    • ""'"t" 2t ASBD-NDT PERSONNEL TRAINING,

,'ASBD-NDT 1101 QUALIFICATIONANDCERTIFICATIONl CNQA 9.2 l

PROCEDURE C

east *= tater '. t. sn ao.

26 FIRST MADE FOR d%

. yj

',~

REVISIONS GEN ER AL h EI.ECTRIC

^ " ^ " ^ " "

7 SERVICE s

l SENERAL ELECT 7.:C cONANY. oNE ANER ROAD. SCHENECTADY. NEW ioPF 17345 DIVISION b

Phone Esta) saast ti i

i

/*'

E

'j

}

m THIS IS TO CERTIFY THAT

- /

has counpleted a heul-course in testing in accordance with the ASBD-NDT training', qualification C.

~ and certi.fication program and ASBD-NDT Training, qualification, s'

~

w.-

and Certification Procedure ASBD-NDT-1101, which scoces the re-y quirenIents o,f ASNT recoaxw.nded practice number SNT-TC-la Qune 4975 Edition).

I l

~,

j m

e NDT Level III Examiner Date

/

y a'

g s.v y

Manager ASBD-NDT Date m'%

i g

NDT-F-105 EXHIBIT V

)

PRINTS TO

=aec ev nopert smith aceao**

ASBD sww on' ASBD-NDT 1101

~ ~~~ ~ ~ ~ S ewe ne cl e ay -- **"'

26

.ws

/g

/

p Loca?. css coat om Sutti - - * =

  • 88' #0-FF(,C) wp [$.801 l

C001 '08"' "O' PRusTED we 93A 3,

e I

. ~

-r..

.,- :- ~ ^.. :--

.----9"'..*:-*--