_
ps nc%
y-t UNITiED STATES g
g NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20565 4001 49.....,o GPU NUCLEAR CORPORATION 8HQ JERSEY CENTRAL POWER & LIGHT COMPANY DOCKET NO. 50-219 OYSTER CREEK NUCLEAR GENERATING STATION AMENDMENT TO FACILITY OPERATING LICEWSE Amendment No.180 License No. DPR-16 l
I 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by GPU Nuclear Corporation, et al.
I (the licensee) dated February 28, 1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as !
amended (the Act), and the Commission's rules and regulations set I
forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
I 9505000174 950501 DR ADOCK 05 29
. 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-16 is hereby amended to read as follows:
(2)
Technical Specifications The technical Specifications contained in Appendices A and B, as revised through Amendment No.180, are hereby incorporated in the license. GPU Nuclear Corporation shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION P bi Phillip F. McKee, Director Project Directorate I-3 Division of Reactor Project - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: May 1, 1995 i
l
t ATTACHMENT TO LICENSE AMENDMENT NO. 180 FACILITY OPERATING LICENSE NO. DPR-16 DOCKET NO. 50-219 i
Replace the following page of the Appendix A, Technical Specifications, with the attached page as indicated. The revised page is identified by amendment number and contains vertical lines indicating the areas of change.
i f
Remove Insert 6-4 6-4 i
I f
e i
I w
6.5.1.2 Proposed chang 33 to ths Appendix
- A" Tcchnical Specifications shall be reviewed by a knowledgeable individual (s)/ group other tlan the individual (s)/ group who prepared the change.
6.5.1.3 Proposed modifications, that affect nuclear safety, to facility l
structures, systems and components shall be designed by an individual /organisation knowledgeable in the areas affected by the proposed i
modification. Each such modification shall be reviewed by an individual / group l
other than the individual / group which designed the modification but may be from the same division as the individual who designed the modification.
6.5.1.4 Proposed tests and experiments that affect nuclear safety shall be reviewed by a knowledgeable individual (s)/ group other than the preparer but who
-may be from the same division as the individual who prepared the tests and experiments.
6.5.1.5 Investigation of all violations of the Technical specifications including the preparation and forwarding of reports covering evaluation and recosusendations to prevent recurrence, shall be reviewed by a knowledgeable individual (s)/ group other than the individual / group which performed the investigation.
6.5.1.6 Events requiring 24-hour written notification to the Commission shall be reviewed by an individual / group other than the individual / group which prepared the report.
6.5.1.7 special reviews, investigations or analyses and reports thereon as requested by the Vice President & Director Oyster Creek shall be performed by a knowledgeable individual (s)/ group.
l 6.5.1.8 The security Plan and implementing procedures shall be reviewed by a knowledgeable individual (s)/ group other than the individual (s)/ group which t i
prepared them.
6.5.1.9 The Emergency Plan and implementing procedures shall be reviewed by a knowledgeable individual (s)/ group other than the individual (s)/ group which prepared them.
6.5.1.10 Review of every unplanned onsite release of radioactive material to the environs including the preparation and forwarding of reports covering evaluation shall be performed by a knowledgeable individual (s)/ group.
Recommendations and disposition of the corrective action to prevent recurrence shall be sent to the Vice President 6 Director Oyster Creek.
6.5.1.11 Major changes to radwaste systems shall be reviewed by a knowledgeable individual (s)/ group other than the individual (s)/ group which prepared them.
6.5.1.12 Individuals responsible for reviews performed in accordance with 6.5.1.1 through 6.5.1.4 shall include a determination of whether or not additional cross-disciplinary review is necessary.
If deemed necessary, such review shall be performed by the appropriate personnel.
Individuals responsible for reviews considered under 6.5.1.1, 6.5.1.3, and 6.5.1.4 shall render determinations in writing with regard to whether or not 6.5.1.1, 6.5.1.3, and 6.5.1.4 constitute an unreviewed safety question.
p4, 1/,
4, 180 h
OYSTER CREEK 6-4 Amendment No.:
i