REACTOR OPERATOR REOUALIFICATION PROGRAM EOR THEjDAHO STATE UNIVERSITY REACTOP, Idaho State, University College of Engineering P.O. Box 8060
- Pocatello, Idaho 83209 I >
S 9508110104 950714 "**
<<.,. t 4-II Purpose -
This document sets forth the requirements for the Reactor Operator and Senior Reactor Operator Requalification Program for idaho State University's (ISU) AGN-201 Nuclear Reactor (Docket #50-284) in accordance with Title 10 of the Federal Code of Regulations Part 55.59 (10CFR55.59). The purpose of the requalification training program is to ensure that all operations personnel maintain proficiency at a level equal to or greater than that required for initial licensing.
II. Schedule A complete requalification training program shall be offered biennially. The program consists oflectures, on the job training, and written, oral, and console evaluations. The classr(x>m retraining includes eight different lectures to be offered at least once during the biennium. 'Ihe evaluations shall be conducted annually. Each operator shall be required to perform licensed functions for at least four hours during each quarter, The performance of licensed functions entails:
- 1) Performance of corrective maintenance.
- 2) Performance of preventive maintenance or surveillaum.
- 3) Radiological work under tL reactor license.
- 4) Making preparations to the facility to perform an experiment with the a reactor.
s 5) Securing from an experiment with the reactor.
.d 6) Reactor console mn time.
- 7) Administering reactor console exams to senior reactor and reactor operators.
1 Each operator licensee shall complete the program hiennially The licensee shall enter i the requalification program on the date the Nuclear Regulatory Commission issues a new {
license. The licensee shall continue in the requalifiertion program until either the l expiration date of the current license or the date at which the current license is l terminated.
)
111. Lecture .
l The program shall include coverage of the following eight topics which shall be offered I at least once during the requalification training period:
Iepic - Reference 'I H, A. Nuclear Reactor Theory Standard Nuclear Engineering Text
} B, Radiation Comre! and Safety 10CFR Parts 20 and 30, ISU W Radiation Safety Manual C. Governing Regulations 10CFR Parts 19, 50, 55, and ^/0 g D. Reactor Design Reactor Facility Study Material s E. Reactor Control and Safety Systems Reactor Facility Study Material .
d P.ev L Til A Pkt I
I$
- gJ.'
h 'i . l s
- ;III. Lecture '(Continued)-
" Topic Reference Q F; Reactor Operating Characteristics Reactor Facility Study Material.
i G. All Reactor Facility Procedures, Operating . Procedures, Emergency Plan,- ,
N Plans, Policies, and Rules Physical Security Plan,' Maintenance and >
Surveillance Procedures, etc.
4 H. Technical Specifications and Technical Specifications and License License Conditions Conditions
- g. Each lecture shall include a brief review of the last Reactor Safety Committee Meeting Minutes .
v.ith an emphasis on approved changes to'the reactor facility procedures. All of the maintenance and surveillance procedure entries since the last lecture shall also be reviewed. The frequent updates shall ensure that the operators are current on all reactor facility activities. ' Any operator. .
may be assigned to present a lecture. !
IV. On the Job Training A. Each operator shall perform licensed functions for at least four hours per quarter :
to satisfy 10CFR55.53(e). :
B. Each operator shall demonstrate familiarity with the following activities at least '
once during the biennial period;
- 1. prestart checks,
- 2. startup, and ;
- 3. termination. <
I This training shall be evaluated by any licensed operator.
C. As a minimum, to demonstrate proficiency at manipulating the reactor facility' .j controls, each operator will perform at least one complete Operating Procedure d #1 (0.P. #1) Stanup and Shutdown per quarter, provided that reuctor operation :
i is possible. Senior reactor operators may not take credit for their required O.P. ,
97 #1 Startup and Shutdown per quaner by directing another operator in reactor- !
facility manipulations. Operators may not take credit for their one required O.P.'
- 1 Stanup and Shutdown per quarter by directing an operator for the purposes of reinstatement.
Rry. 2 TB 4 Pur2 s .
c . _
W V. Evaluations The ability of the operator to perform licensed functions shall be determined through evaluations which shall be conducted annually. These evaluations shall include written and console examinations. These examinations may be administered in any order, at any time during the year, and on different dates.
A. Written Examinations The written examination shall be administered as a closed took exam in a controlled area. The operators shall reference only retained knowledge and shall have only paper, pencils, erasers, and calculators to complete the exam. The content of the examinations shall satisfy the requirements of 10CFR55.41 and may include requirements of 10CFR55.43. The Reactor Supervisor (RS) and the Reactor Administrator (RA) shall be responsible to prepare, administer, and grade the written examination. Therefore, the RS and the RA are exempt from the written examination.
B. Console Examinations Each operator shall demonstrate familiarity with the following operator activities during the console examination:
l l
l 1. prestart check, l
- 2. startup,
- 3. operation at power, and
- 4. termination.
The console examinations are required only during those years in which reactor operation is possible. Console examinations may be evaluated by any senior reactor operator. Every licensee shall participate in the console examination.
C. Grading The criteria for grading the assignment of pass / fail are established as follows:
- 1. Written Examination. The licensee shall be assigned a rating of either SATISFACTORY or UNSATISFACTORY. In order to obtain a rating i of SATISFACTORY, the licensee shall attain a minimum score of 70%
in each section of the examination. If the licensee fails to attain a rating of SATISFACTORY, the licensee shall be removed from his/her licensed duties and enroll in an accelerated training program in the deficient area.
wtm Ps;e )
w s c , & - - -
q yu [. _
y hfe%
LV.. j Evaluiations (Continued) i m .
%~
- 12. Console Examination. The licensee shall be assigned a rating of eithern SATISFACTORY or UNSATISFACTORY.. In order to attain a rating of-
. SATISFACTORY, the licensee should demonstrate an understanding of the ~
-.g operation .of all apparatus and mechanisms. This is evaluated through the
~ '
T case and' smoothness the operator performs the prestart checks, startup,' l power operation, and termination. If the licensee fails to attain a rating . ,
of SATISFACTORY, the' licensee shall be removed from his/her licensed. j duties and enrolled in an accelerated training program'in the deficient area.
n.- :
VI. Operator Reinstatement j
~'
i An operator may be removed from active status by failing to actively. perform the -
functions of an operator during any calendar quarter or by failing to attain a satisfadory - y g grade on an evaluation exam. The calendar quarters are as follows: January through -!
y March, April through June, July through September, and October through December.
10CFR55.53(f) outlines the requirements for operator reinstatement. j y
I If an operator has not actively performed the functions of an operator during a caldndar j quarter, he/she'shall satisfactorily demonstrate his/her competence before ' resuming-his/her licensed functions. - This is accomplished by performing at least six hours of ed licensed functions, including at _least one O.P #1 Startup and Shutdown, under the 1
direction of a licensed operator._ .Upon completion of this activity, the operator shall be ,
certified for operation by the Reactor Supervisar. ,
If an operator has failed to attain a satisfactory grade on any evaluation, he/she'shall _ ;
demonstrate his/her competence before resuming his/her duties. This is accomplished
,1 through participation in additional training in the area of deficiency. ' Upon completion: ;
of the training, the operator shall be certified for operation by the Reactor Supervisor j after successfully completing another evaluation in the area of deficiency. j i
~ Vll. Records .l Operator Requalification tracking shall be maintained through a number of logs and- l forms. Lecture attendance shat! be maintained on the Requalification/ Training Lecture ed Each operator will reevrd their performance of licensed functions' upon
. Forms. -i s
g completion on the Individual Operator Licensed Function Tracking Form. The annual- j written examination key shall be kept as part of the Operator .Requalification records.
j ,
I A record shall be maintained for each licensee and shall contain a current copy of the - j licensee's reactor operator license, copies of all written examinations administered to the j licensee during the requalification period, the medical examination form' from the: '
t J
( licensee's last , medical exam,J and the licensee's Requalification . Program: Progress Checklist.
j
-4 -j Mev. 2,115A ' ;- j rap 4 o i-1 -
d
( '
- l
, . \
i VII. Records (Continued)
]
l The checklist shall contain the record of attended lectures, on thejob training, written and console examination evaluations, a record of operator reinstatement, medical examination g completion date, and medical examination due date. Additional forms may be kept in the ,
s licensee's record to provide supporting documentation and may include license E applications and renewal.
l 1
I 1
I l
l i
l 4
l l
1 F
P.n L TTI% .
Pcs!
g
.,~
IDAIIO STATE U'NIVERSITY NUCLEAR EW11NEERING LABORATORY REQUALIFICATION PROGRAM PROGRESS CHECKLIST Operator License No.
License Effective Date: _/_/___ License Expiration Date:_/_/___
Training period (2 years): Beginning: _/_/_ Ending: _/_/_
Lecture Procram Dalc Instructor
- 1. Nuclear Reactor Theory __f_/_
- 2. Radiation Control and Safety _/_/_
- 3. Governing Regulations _/_/_
- 4. Reactor Design _/_/__.
- 5. Reactor Control and Safety _/_/_
Systems
- 6. Reactor Operating _/_/_
Characteristics
- 7. All Reactor Facility Procedures, _/_/_
Plans, Policies, and Rules
- 8. Technical Specifications _/_/_
and License Conditions _/_/_.
On the Job Training LICENSED FUNCTIONS Date Hours Date Hours Date Hours Total Qtr. 1 .__/ _/_ __/.__/_ _/__J_
/ / _._/_/_ __/_/.__
2 _j_/_ __/_/_ _/_/_
_/_/_ _/_/_ _.j_/_
3 __./ _ / _ _/_/_ _/_/_
_/__/_ _f_/__ __/_/_
4 _/_/__ . _/_/_ _/_/_
, _.)_/_.. _/_/_ _J_/__
- 5 _/_/_ __/_/_ _/_/_
y -
_/_/__ )_/_ _/_/_
6 _/_/__. _/__J_ _/__/_ '
I / _/__J_ _)_/_
7 _/__/_ _/.__/_ _/_/_
__f_/__ _/_/_ _/ _/__
8 _/_/_ ._/_/_ __/_/_
/ / // / /
i 1
R.w. 2, 7 9 %
- u !
r w +
8 np, f.c n
!5s e .
. p .'4r~
s ,
N
/.Qn the Job Trainine (cont.)
7 Prestart Check completed: ._/_/_ Examiner:
Startup completed: _/_/_ Examiner:
Termination' completed: _/.__/_ Examiner:
Evaluations (satisfactory / unsatisfactory)
Written - Year One Date Administered _/_/_ Evaluation
. Year Two Date Administered _f_/_ Evaluation
~ Console Year One Date Examiner Evaluation
- 1. Prestart Check _/_/._ _
- 2. Reactor Startup / /
- 3. Power Operation ._/_/_
- 4. Termination ' _/_/_
Console Year Two Date Examiner Evaluation g _ l. Prestart Check _/_/_
.s .2. Reactor Startup ._/_/_
4 -'3. Power Operation _/_/_
- 4. Termination _/_/_
Onerator Reinstatement .
.. Failure to complete calendar quarter licensed functions requires certification for operation by the Reactor
. Supervisor. This is accomplished by serving 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> of supervised licensed functions and performing'one O.P.
- 1 Startup and Shutdown.
~ Quarter Date Rx. Supervisor i ' Quarter Date Rx. Supervisor
. Quarter Date Rx. Supervisor'- l An ' unsatisfactory grade in the evaluations require certification for operation by the Reactor Supervisor. This .
is accomplished through additional training.
Topic - Date Rx. Supervisor Topic Date' Rx. Supervisor Topic Date Rx. Supervisor .1
' Medical Examination Completion Date: _/_/_
Medical Examination Due Date: _/_/_.
Rrr. 2..TB 4 '
Psy 2 '
.; ;, _ ,;l . *
{1
+
1REQUALIFICATION/ TRAINING LECTURE FOR.M Topic Instructor - Date
- Names of lecture attendees Maintenance and Surveillance Log entries covered in training session:
Log Entry Date Log Entry Date i
Updated Procedures covered in training session:
Procedure Approval Date Procedure Approval Date 4
==
.)
1 1
5 L-I.
Ret 2,IDg t
ni.i - . - . - - .. -_ . . .
- x ...m..- -
- c%
h lif A *
- - .
- ?
n Q y! ,
{y, (:'s ).3 -
x .; .,
llNDIVIDUAL OPERATOR LICENSED FUNCTION
. TRACKING FORM
" Operator Name:
Dalc - Duration of Functions (hrs) Licensed Functions Performed W
emuus 4
414 taut' Rev 2. TB %