TENNESSEE"VANL.bY AUTHORITY

- CHATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II N!O 2 -

eb ary 27,1984 BLRD-50-438/84-12 BLRD-50 '339/84-11

.U.S. Nuclear Regulatory Commission

. Region ::II -

Attn:

W. James P. O'Reilly, Regional. Administrator

'_101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear.Mr. O'Reilly:

BELLEFCNTE NUCLEAR PLANT UNITS 1 AND 2 - HALOGENS IN CARBOLINE 305. PAINT ON SUPPORTS WHICH ARE AGAINST STAINLESS STEEL PIPE - BLRD-50-438/84-12, BLRD-50-439/84 FIRST INTERIM REPORT The ' aubject deficiency was initially reported to NRC-0IE Inspector P. E. Fredrickson on January 31, 1984 in accordance with 10 CFR 50.55(e) as NCR BLN BLP.8401. Enclosed is our first interim report. We expect to

.' submit :our next mport by August 22, 1984.

If you have any questions, please get in touch with R. H. Shell at FTS 858-2474.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, nager Nuclear Licensing w

Enclosure oc:

W. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center-(Enclosure)~

Institute of Nuclear Power Operations 1100 ' Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 I

l

.i 840309d163 840227 PDR ADOCK 05000438 OITICIAL CobY r

S-PDR h37 V

1983-TVA 5OTH ANNIVERSARY

~

An Equal Opportunity Employer-

... - a

]

ENCLO3URE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 HALOGENS IN CARBOLINE 305 PAINT ON SUPPORTS WHICH ARE AGAINST STAINLESS STEEL PIPE

^

BLRD-50-438/84-12, BLRD-50-439/84-11 NCR BLN ELP 8401 10 CFR 50.55(e)

FIRST INTERIM REPORT Description of Deficiency

c. ---

Carbon steel pipe supports top coated with carboline 305 paint, a halogen- _

containing substance, are in contact with stainless steel piping. The deficiency was identified at Bellefonte Nuclear Plant per Program Information Notice 83-8, " Stainless Steel Pipe in Contact with Halogenated Protective Coatings," which documents the possibility of stress corrosion cracking of such piping at temperatums exceeding 140oF. The deficiency resulted from the failure to provide guiMIines in General Construction Specification G-29M restricting halogen-containing paint from contacting stainless steel piping.

Interim Progress TVA's Division of Construction (CONST) will be instructed to mmove the carboline. 305 paint from the carbon steel surfaces at the points where it comes in contact with the stainless steel pipe and system operating temperatures exctaed 140oF.

~

TVA will provide a final report upon determination of the action required to prevent mourrence.