ML20086J065

From kanterella
Jump to navigation Jump to search
AO 75-6:on 740121,RSCS 30% Rated Power Interlock PS-3-3-250A Failed.Caused by Minor Leakage from Bourbon Tube Resulting in Buildup of Moisture in Switch Case.Switch Assembly Replaced,Calibr & Checked
ML20086J065
Person / Time
Site: Peach Bottom 
Issue date: 01/31/1975
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Anthony Giambusso
Office of Nuclear Reactor Regulation
Shared Package
ML20086J066 List:
References
AO-75-6, NUDOCS 8401230087
Download: ML20086J065 (2)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _

O

.=

m D

7-v

. PHILADELPHIA ELECTRIC COMPANY S ~-

S 2301 MARKET STREET

[-.

- [

~~'

p p 3 tr.

t:J PHILADELPHIA. PA.19101

[

/

b i2is 841-4ooo x

MY January 31, 1975 Mr. A. Giambusso Director, Division of Reactor Licensing Office of Nuclear Reactor Regulations U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Dear Mr. Giambusso

Subject:

Abnormal Occurrence The following occurrence was reported to Mr. Tom Shedlowsky, N'.R.C. Region 1 Office of Inspection and Enforcement on January 22, 1975 Written notification was made to Mr. James P. O'Reilly, Region 1 Of fice nf Inenact na aad Eaforca eat en J=ne=ry 22, 8975 In eccerdenca with i

Section 6.7.2.A of the Technical Specifications, Appendix A of DPR-56 for Unit 3 Peach Bottom Atomic Power Station, the following report is being subm.tted to the Directorate of Reactor Licensing as an Abnormal l

Occurrence:

Reference:

License Number DPR-56 Technical Specification

Reference:

3 3 8 3.a Report No.:

50-278-75-6 Report Date:

January 31, 1975 Occurrence Date: January 21, 1975 Facility:

Peach Bottom Atomic Power Station R.D. 1, Delta, Pennsylvania 17314 j

Identification of Occurrence:

Failure of PS-3-3-250A, RSCS 3DX rated power interlock.

Conditions Prior to Occurrence:

Unit 3 shutdwn.

5o -2l3 *f y

8401230087 750131 PDR ADOCK 05000278 S

PDR

.1180, COPY SElff REGION a

V Mr. A. Giambusso e

January 31~,1975 Page 2 Description of-Occurrence:

During a routine instrunent surveillance test, PS-3-3-250A was found to have suffered corrosion damage which rendered it inoper ab le.

The corrosion resulted from a buildup of mois ture in the switch housing.

Designation of Apparent Cause of Occurrence:

Minor leakage from the bourdon tube resulting in a building of mois ture in the switch case.

Analysis of Occurrence:

Because either the PS-250A or PS-250B switch serves independently to arm the RSCS below 30% rated power, the failure of only one of these switches has minimal safety implications.

Corrective Action:

The entire switch assembly was replaced in kind, calibrated, and checked in accordance with the applicabic surveillance test.

Failure Data:

None previous.

Very truly yours,

,,f [ /

% 'J

- a

/

.f) I jfD th,M, h,'

M. J. C oon e~y l'

/

Ass' t Gen' t Superintendent j

Generation Division cc:

Mr. J. P. O'Reilly Director Office of Inspection and Enforcement l

Region 1 United States Nuclear Regulatory Coanission 631 Park Avenue King of Prussia, PA 19406 l

6 L