ML20086G188

From kanterella
Jump to navigation Jump to search
Forwards ISI Rept for Activities Performed at Plant from 931210 to 950429,including Fifth Refueling Outage
ML20086G188
Person / Time
Site: Clinton 
Issue date: 07/10/1995
From: Phares R
ILLINOIS POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20086G197 List:
References
L30-95(07-10)LP, L30-95(7-10)LP, NUDOCS 9507140162
Download: ML20086G188 (1)


Text

.....

=

lihnois Power Company Cisnton Power Station i

P.O. Box 678 Chnion. IL 61727 Tel 217 935-8881 U-602465 R

L30 95(07 -10 )LP 1 A.120 July 10, 1995 Docket No. 50-461 Document Control Desk Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Clinton Power Station Inservice Inspection Summary Report t

Dear Sir:

In accordance with ASME Section XI, Article IWA-6000, Illinois Power Company (IP)

[

submits the enclosed Inservice Inspection Summary Report. This summary report addresses the Inservice Inspection activities performed at Clinton Power Station from December 10,1993 to April 29,1995 including the fifth refueling outage.

E Sincerely yours, Db Ar Richard F. Phares s

Director, Licensing AJP/kdk Enclosure i

cc:

NRC Clinton Licensing Project Manager NRC Resident Oflice, V-690 Regional Administrator, Region III, USNRC Illinois Department of Nuclear Safety

!.3 I i 3 3

'I I

9507140162 950710 PDR ADOCK 05000461 Q

PDR

-,. _